Next Article in Journal
The Role of Compensatory Adaptations and Individual Variability in Exercise Prescription
Previous Article in Journal
The Effect of Jet Lag on Postural Stability
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

An Extensive Evaluation of Different Knee Stability Assessment Measures: A Systematic Review

1
School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, Edgbaston Campus, Birmingham, West Midlands B15 2TT, UK
2
The Royal Orthopaedic Hospital, the Woodlands, Bristol Rd South, Birmingham, West Midlands B31 2AP, UK
3
Physiotherapy Department, Kuwait Petroleum Company Hospital, Ahmedi 2097, Kuwait
*
Author to whom correspondence should be addressed.
J. Funct. Morphol. Kinesiol. 2016, 1(2), 209-229; https://doi.org/10.3390/jfmk1020209
Submission received: 31 March 2016 / Revised: 31 March 2016 / Accepted: 19 April 2016 / Published: 25 April 2016

Abstract

:
Re-injury to a recently rehabilitated or operated knee is a common occurrence that can result in significant loss of function. Knee stability measures have been used to diagnose and assess knee stability before and after rehabilitation interventions. Here, we systematically review the literature and evaluate the different anterior-posterior and rotational knee stability measures currently in use. A computer-assisted literature search of the Medline, CINAHL, EMBASE, PubMed and Cochrane databases was conducted using keywords related to knee stability measures. In a second step, we conducted a manual search of the references cited in these articles to capture any studies that may have been missed in the searched databases. The literature search strategy identified a total of 574 potential studies. After revisiting the titles and abstracts, 34 full-text articles met the inclusion criteria and were included in this review. Most articles compared knee stability measures, whilst other studies assessed their sensitivity and specificity. Several techniques and devices used to measure knee stability are reported in the literature. However, there are only a limited number of quality studies where these techniques and/or devices have been evaluated. Further development and investigation with high quality study designs is necessary to robustly evaluate the existing devices/techniques.

1. Introduction

Knee stability is critical for many sports, and decreased stability is strongly associated with risk of injury [1,2]. The “giving way” phenomenon associate with knee joint instability has been shown to result from injury to mechanical constraints and associated neuromuscular impairment [3]. At present, an objective and universally-accepted measure of knee joint stability does not exist. It is therefore difficult to sufficiently quantify when an injured knee has recovered and when an individual may safely return to sport.
Despite a large number of preventative rehabilitation protocols proposed to reduce knee injuries [4,5], the incidence of knee injury remains high, with one study suggesting it accounts for nearly a quarter of all injuries sustained in professional football [6]. For example, Prodromos et al. [7] reviewed the incidence rates of Anterior Cruciate Ligament (ACL) injury, which is the most common knee stabilizer that is injured. They noted that collegiate soccer players had an incidence of 0.32, basketball players 0.29 and recreational alpine skiers 0.63 per 1000 exposures.
A key element to reduce recurrent knee injuries following treatment is the integration of subjective examination techniques, objective instrumented devices and imaging techniques for diagnosis and guidance in return-to-play [8,9]. Several studies [10,11,12,13] have investigated the usefulness of different knee stability measures to diagnose knee injuries and to provide additional information on return-to-play or return-to-work decisions. Although the diagnostic accuracy of knee stability measures has previously been evaluated, as yet, a gold standard measure has not been synthesized.
Surgery for the correction of knee instability has increased over the last two decades. Nevertheless, return to competitive sport has been reported as low as 55% [14]. This inconsistency together with the high cost of such surgeries [15] highlights the need for better clinical pre- and post-surgical measures of knee instability. The use of better clinical assessments is likely to improve surgical case selection and post-surgical rehabilitation. Previous reviews suggested that further research is needed to truly understand the clinical relevance inherent in new device designs [9,16]. Therefore, the objective of this study was to conduct an extensive systematic review of the literature to describe and evaluate knee stability measures used for diagnosis and assessment for return-to-play after instability-related knee injury/surgery.

2. Materials and Methods

2.1. Search Strategy

Medline, CINAHL, EMBASE, PubMed and Cochrane databases were searched electronically for English-language studies published up to December 2015. All databases were searched using the Index Medicus Medical Subject Headings (MeSH), such as “anterior cruciate ligament” and “arthrometry” (see Table 1 for the full search details). A manual search was also performed to check reference list of each of the included articles in order to capture articles that might not have been listed on the databases. Differences of opinion were resolved through discussion with the third author (MB). This review used the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for the search and reporting phases of the study.

2.2. Inclusion and Exclusion Criteria

Articles examining knee stability measures were eligible if they met all of the following criteria: (1) full-text published articles in peer-reviewed journal and articles in press (grey literature); (2) assessed anterior-posterior and rotational knee stability; and (3) written in English. Studies were excluded from the review if they: (1) recruited participants with systematic disease; (2) used non-human subjects; (3) assessed cadavers.

2.3. Data Extraction

One reviewer independently extracted the data and information regarding the examined knee stability measure, study population, age, sensitivity and specificity (JA). Any possible disagreement was resolved during a scheduled meeting. Both quantitative data and qualitative data were extracted from the included studies. The quantitative outcome measures extracted from each study were: (1) “test sensitivity”, which was defined as the percentage of people who test positive for a specific pathology among a group of people who have the pathology; (2) “test validity”, which was defined as the percentage of people who test negative for a specific pathology among a group of people who do not have the pathology. The qualitative data were the applicability of the measures.

Risk of bias/Quality Assessment

Two authors independently assessed the quality of the articles that met the inclusion criteria (JA + CA). Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool [17]. QUADAS is a validated clinometric tool used to assess the overall quality of diagnostic accuracy studies through individual quality component questions. Any possible disagreement was planned to be resolved during a scheduled meeting. Based on similar published reviews, any study with a QUADAS score ≥10 was stratified as “high quality/low risk of bias”, and any study scoring <10 was considered “low quality/high risk of bias” [18].

2.4. Synthesis of Results

It was not appropriate to combine studies for meta-analysis due to the heterogeneity of the included studies and the variable reference standard. Therefore, the results were tabulated for semi-quantitative comparison of the sensitivity and specificity variables. The qualitative data were descriptively discussed.

3. Results

3.1. Selection of Studies

The systematic literature search strategy through the selected databases identified a total of 571 potential abstracts. Three additional abstracts were handpicked through manual search. Duplicate entries were removed from the two databases, leaving 105 abstracts to be assessed for eligibility. After revisiting the titles, abstracts and full text articles, 34 full-text articles met the criteria for inclusion in this review (Figure 1). This review included a total of 2133 participants investigating eight different knee stability measures. The sample size of the studies ranged from five to 401 participants.

3.2. Quality Scores

Table 2 provides the overall risk of bias score. Fourteen studies demonstrated “high quality/low risk of bias” and 20 demonstrated low quality/high risk of bias.

3.3. Pooled Results from the Individual Knee Stability Measures

3.3.1. Quantitative Data

Fifteen studies investigated the KT-1000 arthrometer; three studies investigated the Lachman test; nine studies investigated the pivot shift test; seven studies investigated the anterior drawer test; three studies investigated a navigation system; five studies investigated the Genucom arthrometer; five studies investigated the rolimeter; two studies investigated Telos radiography; and five studies investigated the ACL-hamstring reflex arc. Table 3 reports which tests each study investigated and the sensitivity and specificity of each test, as well as the sample size and age of the study participants.

3.3.2. Qualitative Data

Lachman Test

The Lachman test is used widely in clinical setting as it is fast and easy to perform for assessing the instability of the knee [47]. The test is performed with the patient supine and the knee relaxed at 20° to 30° of flexion. The examiner places one hand on the distal end of the thigh and the other hand behind the proximal end of the tibia. The tibia is then translated anteriorly on the femur, and the endpoint is assessed as firm (intact ACL) or soft (injured ACL). An injured ACL should be graded either I < 2 mm, II 2 to 5 mm, III > 5 mm.
The literature lacks consensus on the usefulness of the Lachman test as a measure of anterior knee stability. Its reliability and validity range from 87% to 97% and 91% to 97%, respectively [12,28,48]. One of the disadvantages of the Lachman test is the difficulty for examiners with smaller hands to perform it properly. It is restricted to examiners with larger hands to properly perform it [49,50], as it needs a firm griping of the femur to displace the tibia anteriorly. As a result, conducting the test in a prone position has been proposed and yielded a positive alternative to the Lachman test [51]. Moreover, Muller et al. [52] examined the proficiency in performing the prone Lachman test as opposed to the classic Lachman. They showed that prone Lachman yielded 78% of positive predictive value while the classic Lachman 28%. The prone Lachman test uses gravity to pull down the femur, which will let the examiner grip and displace the tibia in both hands [53]. Consequently, the size of the knee may be an important factor in deciding which knee instability measure should be used to assess knee stability.

Pivot Shift Test

Galway, Beaupre and MacIntosh [54] initially described the pivot shift test as an examination tool of functional knee instability. This is performed with the patient supine with the examiner standing lateral to the patient holding the knee and ankle in 20° of internal rotation, with the patient`s hip flexed to 30°. A valgus force is applied to the proximal tibia, to create impingement of the plateau on the femur. The knee is then flexed and assessed for a clunk due to the reduction of the displaced tibia on the femur, which normally occurs between 20° and 30°. The motion is then graded as: 0 = no clunk, I = glide, II = clunk and III = gross clunk with locking. A false negative may be obtained in patients with Iliotibial Band (ITB) pathology, medial collateral ligament injury, a bucket handle meniscus tear or a flexion contracture. A false positive pivot shift may be present in a patient with increased laxity. Comparison with the uninjured knee should always be undertaken.
There is a controversy in the literature on the usefulness of the pivot shift test. The controversy surrounds the various techniques used by clinicians when performing the pivot shift test. Variations exist particularly in the degree of knee flexion, hip flexion and tibial internal rotation [31]. It is difficult to assess the effect on the test outcome of associated injuries to the knee and the limited range of motion in knees with injured meniscus [55]. Similarly, the subjectivity on the amount of the applied valgus force whilst doing the test leads to difficulties in replicating the test for confirmation [33]. The specificity of the pivot shift test has been shown to be dependent on whether or not the patient is anaesthetized [56]. It ranges from 32% without to 85% with anaesthesia; this result was confirmed by Kuroda et al. [34], who theorised that muscular resistance can suppress the pivot shift manoeuver.

Anterior Drawer Test

The anterior drawer test specifically assesses the anterior stability of the knee [57]. Several studies reported that clinicians use it widely in both clinics and operation theatres [16,38,54,58,59,60]. It is performed in a supine position, with the knee at 90° flexion and the hip at 45° flexion. The examiner sits on the patient’s tested foot and with one or both hands grasping the proximal end of the leg aligning the thumb(s) with the anterior joint line. The tibia is then pulled anteriorly, and an assessment is made of the relative translation of the tibia on the femur. The tibia should displace within a similar range to the sound knee. If an excessive displacement occurs in the injured knee compared to the sound knee and a soft endpoint is felt, it is assumed that there is an ACL injury yet to be confirmed with an objective knee instability measure.
The anterior drawer test has an agreement in the literature regarding its usefulness [38,59]. Mitsou et al. [38] highlighted the difficulty in performing the anterior drawer test at the acute stage following a suspected ACL injury. In addition, they reported specificity ranged from 78% to 99% when patients were examined under general anaesthesia. On the other hand, Scholten et al. [59] concluded that such a test is of unproven value. It has been shown that failure to quantify the amount of displacement of the tibia on the femur and inability to use it in the acute stage of injury were weaknesses of this test.

The Rolimeter

The rolimeter (Aircast Europa, Neubeuern, Germany) is a portable knee arthrometer used to measure anterior-posterior displacement of the tibia on the femur while performing the Lachman test [21]. It is performed whilst the patient is positioned supine with 30° flexion of the tested knee. Next, a proximal convex pad is placed over the patella and a distal pad placed over the tibia with a strap. The two pads are connected a few inches above the limb by a steel bar. A feeler should be placed over the tibial tubercle; the Lachman test is performed after the device has been zeroed. To that end, the anteroposterior displacement of the tibia on the femur is measured in increments of 2 mm by the marks on the feeler. A difference of 4 mm or greater, in comparison with the uninjured knee, is suggestive of an ACL injury [60].
Rolimeter provides an economic, exact and simple device for quantifying anterior knee joint instability [21]. Among 20 healthy participants and 18 patient with chronic ACL injury, Ganko et al. [27] assessed the reliability of the rolimeter as opposed to the KT-1000. In the mean knee displacement, both devices showed strong correlation (r = 0.73, p < 0.001) for the injured knees, while there was no significant correlation in their uninjured knees (r = 0.32, p > 0.10). Hence, they concluded that, with experienced examiners, the rolimeter is a valid method to assess anterior knee instability. However, its specificity as a standalone measure of knee stability (84.3) was questioned when compared to its results alongside clinical examination (92.4) [40]. This was justified based on the fact that the rolimeter does only measure the anterior-posterior stability rather than the rotational stability of the knee [27]. The use of the rolimeter as a standalone measure can give false negative results with the notion that knee stability is maintained by both anterior-posterior and rotational mechanical stability [61].

The Genucom Knee Analysis System

The Genucom knee analysis system (FARO Medical Technologies Inc., Montreal, QC, Canada) is a computerized device developed in the1980s to objectively measure knee stability in different planes (e.g., sagittal and frontal planes) [60]. The participant’s tested knee is positioned in 20° flexion and the thigh secured with restraints. An electro-goniometer is attached to the thigh, with anatomical markers placed on the medial and lateral femoral condyle, patella and tibial crest. The markers are digitized, and then, the relative displacement of the knee is recorded in addition to the distance between the markers [30].
The Genucom knee analysis system is the only objective instrument to provide a multiplanar measure of knee stability, but it is more complicated and time consuming to use compared to other measures [30,67]. Furthermore, it has poor sensitivity, and its cost-effectiveness has been questioned [42]. As a result, it has fallen out of common use.

The KT-1000/KT-2000 Arthrometer

The KT-1000 knee ligament arthrometer (MEDmetric Corp, San Diego, CA, USA) is the most commonly-used arthrometer in both a clinical and research setting [32]. It is an objective device that measures anterior-posterior translation of the tibia on the femur in millimetres [68]. The patient should remain in a supine position on the examination bed with the tested knee supported at 30° of flexion using a goniometer. The thigh strap, thigh support platform and foot support should be placed on and attached to the patient. The KT-1000 arthrometer is secured over the participant’s leg in the ideal position with reference to the knee joint line. The Lachman and anterior drawer tests can then be performed with the KT-1000.
Its reliability has been tested in several studies (Table 3). The side-to-side difference is the recommended measure to use for assessment of anterior knee stability [69]. The experience of the examiners plays an important role in the result of the test [19,70]. The KT-2000 has the same method of use as the KT-1000 with the added feature of graphic documentation via an X-Y plotter. It produces data regarding the amount of knee displacement and the magnitude of the applied force.
Despite the large number of KT-1000/2000 studies in the literature, there is no consensus on its sensitivity and specificity in measuring anterior-posterior knee laxity. Its sensitivity ranged from 0.50 [23] to 0.97 [16], and its specificity ranged from 0.70 [42] to 0.93 [16]. The wide range in the sensitivity and specificity was justified based on the quality of the conducted studies, the experience of the examiner and the amount of force being utilized in each test [44]. Regardless of the controversy regarding the sensitivity and specificity of the KT-1000 arthrometer, it is commonly used in research rather than in a clinical setting [8]. However, the majority of the available literature supports the KT-1000 arthrometer as being at least equal to other available knee stability measures [16,23,29,42].

The Telos Stress Radiography Device

The Telos stress radiograph (Telos GmbH, Laubscher, Holstein, Switzerland) is a device that can measure knee stability by utilizing stress forces with high quality radiographic images [24]. It was originally described by Staubli and Jacob [71]. The test involves the application of an anterior stress to the injured knee; the subsequent displacement is the measured on a lateral X-ray. The displacement is described relative to the opposite “normal” side.
The two included articles in this review that investigated the usefulness of the Telos as a measure of knee stability showed that its sensitivity ranged from 0.72 [70] to 0.88 [40], and it had a specificity of 0.82 [40]. Similarly, Jardin et al. [70] compared the KT-1000 to Telos after anterior cruciate ligament reconstruction. They recommended Telos instead of KT-1000 to assess knee stability after ACL reconstruction. The widespread range in the sensitivity and specificity was vindicated based on the variation in the quality of the X-rays obtained, the experience of the radiographer and the experience of the radiologist in reading such radiographs [71,72]. Nevertheless, imaging techniques (e.g., Telos) are an established tool to confirm the diagnosis of suspected knee instability, to assess the ACL reconstruction outcome and to rule out injuries to other soft tissue structures [40,70].

ACL-Hamstring Stretch Reflex

This is designed to measure the onset latency of biceps femoris muscle. Hence, it is not designed per se as a test of knee stabilisation. It uses electromyography (EMG) to record muscle activity produced by a stretch reflex elicited by the application of anterior-posterior translation of the knee joint. The latency of the biceps femoris stretch reflex is then calculated and used as an indicator of knee stability and neuromuscular function [22].
It has been evaluated in several studies to assess muscle fatigue, knee stability [73] and knee proprioception [74]. It is used in operative theatres through a direct pull of the ACL to differentiate short and long latencies [75]. The reflex has been investigated intra-operatively by direct traction under arthroscopic visualization and in a research setting by instrumenting a laboratory-based rig [11]; thus, its clinical usefulness is doubtful. Three studies by Schoene et al. [11], Friemert et al. [26] and Melnyk et al. [73] revealed that the ACL-hamstring reflex measurement could be elicited, specifically for injured ACLs. Previous work by Friemert et al. [26] has shown that a prolonged reflex was present in patients with a ruptured ACL. The longer reflexes corresponded with patients who had instability symptoms even though mechanical testing with the KT-1000 showed no difference. On the other hand, Melnyk and Gollhofer [73] concluded that it was hamstring muscle fatigue during submaximal isometric exercises that was the reason behind the longer latencies of the hamstring stretch reflex and not the existing ACL injury. Despite the argument in the literature on its usefulness for detecting the aforementioned variables, the authors suggested that this technique has room for improvement in terms of its applicability in a clinical setting to guide rehabilitation protocols [3,11,74].

4. Discussion

This present paper systematically reviewed a broad spectrum of knee measures designed to assess anterior and rotational stability. Similar to others used in the hip [76], ankle [77] and hamstring injuries [78], the existing tests for knee stability assessment are deficient in relation to diagnosis, surgical outcome assessment and clinical decisions on return-to-play following injury or surgery.
The subjective tests demonstrated variability in sensitivity and specificity of each test (Table 3), thus questioning their clinical usefulness as stand-alone measures. As with any subjective test, comparing the outcome of tests is difficult due to the subjective nature of the grading system. On the other hand, objective tests can be quantitatively compared to each other in terms of their sensitivity and specificity. For example, the sensitivity and specificity of the Genucom knee analysis system have been reported to be low, at 60% and 65%, respectively [42].On the other hand, the KT-1000 sensitivity at maximum manual force is 93%, and it has a specificity of approximately 93% [16]. Despite the existing studies on the use of the hamstring-stretch reflex [26,73,74,75], the literature lacks evidence on whether the reflex latency can be a valid objective clinical knee stability measure.
Mitsou and Valiiianatos et al. [38] showed that the anterior drawer test is reliable when used for chronic knee cases. On the contrary, a review by Van Eck et al. [16] suggests that the anterior drawer test is less sensitive (0.74) than the KT-1000 arthrometer (0.93). The literature disagreement is based on the difference of knee conditions being examined and the quality of the studies conducted. However, the anterior drawer test has been used in a clinical setting and in-the-field as a quick and early assessment technique of ACL injury.
The specificity of the pivot shift test ranged from 32% without to 85% with anaesthesia. Muller et al. (2015) [52] reported an ICC for intra-tester reliability ranging from 0.913 to 0.999 (95% CI range: 0.319 to 1.000) and ICC for inter-tester reliability of 0.949 (95% CI: 0.542 to 1.000) for iPad software (The PIVOT software, iOS, programming language Objective-C) designed specifically for quantifying the pivot shift test. Nevertheless, Hoshino et al. (2013) [56] did quantify the pivot shift test using an iPad tablet (Apple Inc., Cupertino, CA, USA). They concluded that pivot shift measurements using an iPad did provide quantification of rotational stability for ACL-deficient knees. However, the limitation of their study was the use of subjective clinical grading as a reference standard to the quantified iPad results. This produced bias in the notion that the same tester performed the subjective grading and the quantitative measurements. The quantification of the pivot shift test using the iPad technique needs to be investigated further to assess its robustness on a larger and cross-sectional population. Due to the intra-examiner variation in the technique being used for the assessment of knee stability, subjective tests need to be tough and applied in a standardized fashion. These differences make comparisons between the reported results in the literature difficult because of the inability to accurately and systematically compare two different techniques [79]. Hence, a better evaluation of each test needs to be conducted.
In spite of the accuracy of the navigation system when compared to a robotic testing system (ICC was 0.9976) [65], its use is limited to surgical procedures; it is expensive and requires surgical experience, thus limiting its use in clinical practice. Unlike the navigation and Genucom knee analysis systems, the rolimeter has superiority as a lightweight device and can be used in clinical, surgical and in-the-field settings. The inability to quantify the magnitude of the pulling force and the difficulty of assessing the functional instability of ACL reconstructed knees are disadvantages of this device [32]. Consequently, using the rolimeter adjacent to physical examination and imaging techniques would be preferable.
Telos stress radiography has the advantage of measuring knee stability in a number of planes (sagittal, frontal and horizontal) [40]; unlike other devices, which only measure the laxity in one direction (anterior-posterior) or two directions (anterior-posterior and rotational movement) [8]. The Telos system is unable to measure rotational instability and also has the disadvantage of radiation exposure when participants/patients are being tested; thus, it should be used judiciously.
There are a number of reasons for the poor clinical usefulness of the reviewed knee stability measures and the challenges in reviewing them. Firstly is the different pathomechanics between injured knees [79,80], as well as inter-individual variations in patient outcome during rehabilitation programs [80]. Secondly, the majority of the knee stability measures for anterior and rotational instability were highly sensitive, but had lower specificity (Table 3). Consequently, a positive test means little in the diagnosis of rotational instability, since the same test will also be positive in anterior instability. Thirdly, there is a risk that lower quality studies fail to fully discriminate the true usefulness of the various knee stability measures. Fourthly, limitations in experiment design affect the interpretability and generalizability of these measures.
The quality assessment of the studies included in this review indicates that many of the studies in this area lack scientific rigour. The median QUADAS score was nine, and 20 of the 34 studies reviewed had a score of less than 10. The studies we reviewed were typically underpowered; they failed to report important study details (see the QUADAS scoring details in Table 2) or failed to compare to a reference standard (see Question 5 in Table 2). Only twelve of the 34 studies used a reference standard, whilst most studies had a sample size greater than 30 participants (range: five to 401), nearly half of the studies had a low effect size (d < 0.3), with five studies reporting a medium effect (0.3 < d < 0.8) and only three studies reporting a large effect size (d ≥ 0.8). As a result, it is difficult to draw strong conclusions from much of the reported data. In almost half of the reviewed studies (n = 15), the selection criteria of their samples were not clearly described (see Question 2 in Table 2), and some studies did not adequately describe participant withdrawals (see Question 14 in Table 2). In two studies, the sex of the recruited sample was not described [40,43], and several studies [35,44,46,63] recruited a mixture of males and females without accounting for the known increased knee instability of females compared to males [81].
The use of a reference standard in the testing diagnostic apparatus is critical for an understanding of accuracy and reproducibility [17]. Whilst only twelve studies in the present review used a reference standard, eight studies did not use a reference standard, and the remaining thirteen studies did not clarify if a reference standard was used or not (see Question 5 in Table 2). Of the studies that used a reference standard, two studies used the KT-2000 arthrometer [27,28]; one study used both the genucom and the KT-2000 [20]; five studies used knee arthroscopy [19,22,36,40,42]; two studies used both physical examination and arthroscopy [23,41]; and two studies used Magnetic Resonance Imagery (MRI) [9,35]. Although knee arthroscopy was used in five studies, such a procedure is not cost effective [82]. Additionally, the ability to assess and diagnose patients in a clinic with simpler diagnostic tests allows rehabilitation to proceed rapidly and economically. Unlike the KT-2000 arthrometer, the magnetic resonance scan is not a knee stability measure. The MRI only shows the integrity of the knee structures in a static position [83], rather than measuring the displacement of the tibia relative to the femur. These results highlight the lack of a robust gold standard knee stability measure. Hence, the lack of an accepted reference standard leads to biased estimates of the tested instruments and reconstruction techniques.

5. Conclusions

We have reviewed a broad spectrum of knee stability measures designed to detect anterior-posterior and rotational knee instability. Whilst there is a wide variety in diagnostic accuracy, many of the studies lack scientific rigour. Despite the importance of such measures, there is no consensus in the literature on a single gold standard measure of knee instability. As a result, there is a need for high-quality randomized control trials, which are sufficiently powered, in order to move closer to a gold standard knee stability measure. In the meantime, clinicians must consider the limited capacity of the reviewed knee stability measures in making a definite clinical decision on the severity of an injury and/or return-to-play.

Acknowledgments

Jawad F. Abulhasan is funded by a scholarship obtained from the Cultural office at Kuwait Embassy in London. No other financial assistance was received for this project.

Author Contributions

Jawad F. Abulhasan wrote the manuscript and responded to all of the feedback and comments from the co-authors. Jawad F. Abulhasan and Cameron M. Anley individually performed the literature search. Jawad F. Abulhasan and Mohammad M. Bakhsh individually performed the quality assessment of each included study. Cameron M. Anley and Martyn D. Snow revisited the manuscript for comments and feedback. Michael J. Grey supervised the work and provided feedback and comments on every draft of the manuscript.

Conflicts of Interest

The authors have neither conflicts of interest nor commercial interests related to the content of this review. The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results.

Abbreviations

The following abbreviations are used in this manuscript:
ACLAnterior Cruciate Ligament
MBMohamed Bakhsh
PRISMAPreferred Reporting Items for Systematic Reviews and Meta-Analyses
JAJawad Abulhasan
CACameron Anley
QUADASQuality Assessment of Diagnostic Accuracy Studies
MmMillimetre
ITBIliotibial Band
ICCIntra-class Correlation Coefficient
EMGElectromyography
CIConfidence Interval
MRIMagnetic Resonance Image
MGMichael Grey
MMFManual Muscle Force
APAnterior-Posterior

References

  1. McCall, A.; Carling, C.; Davison, M.; Nedelec, M.; Le Gall, F.; Berthoin, S.; Dupont, G. Injury risk factors, screening tests and preventative strategies: A systematic review of the evidence that underpins the perceptions and practices of 44 football (soccer) teams from various premier leagues. Br. J. Sports Med. 2015, 49, 583–589. [Google Scholar] [CrossRef] [PubMed]
  2. Ter Stege, M.H.; Dallinga, J.M.; Benjaminse, A.; Lemmink, K.A. Effect of interventions on potential, modifiable risk factors for knee injury in team ball sports: A systematic review. Sports Med. 2014, 44, 1403–1426. [Google Scholar] [CrossRef] [PubMed]
  3. Melnyk, M.; Faist, M.; Gothner, M.; Claes, L.; Friemert, B. Changes in stretch reflex excitability are related to “giving way” symptoms in patients with anterior cruciate ligament rupture. J. Neurophysiol. 2007, 97, 474–480. [Google Scholar] [CrossRef] [PubMed]
  4. Gilchrist, J.; Mandelbaum, B.R.; Melancon, H.; Ryan, G.W.; Silvers, H.J.; Griffin, L.Y.; Watanabe, D.S.; Dick, R.W.; Dvorak, J. A randomized controlled trial to prevent noncontact anterior cruciate ligament injury in female collegiate soccer players. Am. J. Sports Med. 2008, 36, 1476–1483. [Google Scholar] [CrossRef] [PubMed]
  5. Mandelbaum, B.R.; Silvers, H.J.; Watanabe, D.S.; Knarr, J.F.; Thomas, S.D.; Griffin, L.Y.; Kirkendall, D.T.; Garrett, W. Effectiveness of a neuromuscular and proprioceptive training program in preventing anterior cruciate ligament injuries in female athletes: 2-Year follow-up. Am. J. Sports Med. 2005, 33, 1003–1010. [Google Scholar] [CrossRef] [PubMed]
  6. Ekstrand, J.; Hägglund, M.; Waldén, M. Injury incidence and injury patterns in professional football: The uefa injury study. Br. J. Sports Med. 2011, 45, 553–558. [Google Scholar] [CrossRef] [PubMed]
  7. Prodromos, C.C.; Han, Y.; Rogowski, J.; Joyce, B.; Shi, K. A meta-analysis of the incidence of anterior cruciate ligament tears as a function of gender, sport, and a knee injury–reduction regimen. Arthroscopy 2007, 23, 1320–1325. [Google Scholar] [CrossRef] [PubMed]
  8. Pugh, L.; Mascarenhas, R.; Arneja, S.; Chin, P.Y.; Leith, J.M. Current concepts in instrumented knee-laxity testing. Am. J. Sports Med. 2009, 37, 199–210. [Google Scholar] [CrossRef] [PubMed]
  9. Leblanc, M.-C.; Kowalczuk, M.; Andruszkiewicz, N.; Simunovic, N.; Farrokhyar, F.; Turnbull, T.; Debski, R.; Ayeni, O. Diagnostic accuracy of physical examination for anterior knee instability: A systematic review. Knee Surg. Sports Traumatol. Arthrosc. 2015, 23, 2805–2813. [Google Scholar] [CrossRef] [PubMed]
  10. Barcellona, M.; Christopher, T.; Matthew, C.M. Bench testing of a knee joint arthrometer. Orthopedics 2013, 36, e1000–e1006. [Google Scholar] [CrossRef] [PubMed]
  11. Schoene, M.; Spengler, C.; Fahrbacher, B.; Hartmann, J.; Melnyk, M.; Friemert, B. The reliability of a method for measuring the anterior cruciate ligament-hamstring reflex: An objective assessment of functional knee instability. Knee Surg. Sports Traumatol. Arthrosc. 2009, 17, 1107–1116. [Google Scholar] [CrossRef] [PubMed]
  12. Wiertsema, S.H.; van Hooff, H.J.A.; Migchelsen, L.A.A.; Steultjens, M.P.M. Reliability of the KT1000 arthrometer and the lachman test in patients with an acl rupture. Knee 2008, 15, 107–110. [Google Scholar] [CrossRef] [PubMed]
  13. Kostov, H. Reliability assessment of arthroscopic findings versus MRI in ACL injuries of the knee. Acta Inform. Medica 2014, 22, 111–114. [Google Scholar] [CrossRef] [PubMed]
  14. Ardern, C.L.; Taylor, N.F.; Feller, J.A.; Webster, K.E. Fifty-five per cent return to competitive sport following anterior cruciate ligament reconstruction surgery: An updated systematic review and meta-analysis including aspects of physical functioning and contextual factors. Br. J. Sports 2014, 48, 1543–1552. [Google Scholar] [CrossRef] [PubMed]
  15. Saltzman, B.M.; Cvetanovich, G.L.; Nwachukwu, B.U.; Mall, N.A.; Bush-Joseph, C.A.; Bach, B.R. Economic analyses in anterior cruciate ligament reconstruction: A qualitative and systematic review. Am. J. Sports Med. 2015. [Google Scholar] [CrossRef] [PubMed]
  16. Van Eck, C.F.; Loopik, M.; van den Bekerom, M.P.; Fu, F.H.; Kerkhoffs, G.M. Methods to diagnose acute anterior cruciate ligament rupture: A meta-analysis of instrumented knee laxity tests. Knee Surg. Sports Traumatol. Arthrosc. 2013, 21, 1989–1997. [Google Scholar] [CrossRef] [PubMed]
  17. Whiting, P.; Rutjes, A.; Reitsma, J.; Bossuyt, P.; Kleijnen, J. The development of quadas: A tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med. Res. Methodol. 2003, 3. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  18. Hegedus, E.J.; Goode, A.; Campbell, S.; Morin, A.; Tamaddoni, M.; Moorman, C.T.; Cook, C. Physical examination tests of the shoulder: A systematic review with meta-analysis of individual tests. Br. J. Sports Med. 2008, 42, 80–92. [Google Scholar] [CrossRef] [PubMed]
  19. Anderson, A.F.; Lipscomb, A.B. Preoperative instrumented testing of anterior and posterior knee laxity. Am. J. Sports Med. 1989, 17, 387–392. [Google Scholar] [CrossRef] [PubMed]
  20. Anderson, A.F.; Snyder, R.B.; Federspiel, C.F.; Lipscomb, A.B. Instrumented evaluation of knee laxity: A comparison of five arthrometers. Am. J. Sports Med. 1992, 20, 135–140. [Google Scholar] [CrossRef] [PubMed]
  21. Balasch, H.; Schiller, M.; Friebel, H.; Hoffmann, F. Evaluation of anterior knee joint instability with the Rolimeter A test in comparison with manual assessment and measuring with the KT-1000 arthrometer. Knee Surg. Sports Traumatol. Arthrosc. 1999, 7, 204–208. [Google Scholar] [CrossRef] [PubMed]
  22. Beard, D.; Kyberd, P.; Fergusson, C.; Dodd, C. Proprioception after rupture of the anterior cruciate ligament. An objective indication of the need for surgery? J. Bone Jt. Surg. Br. Vol. 1993, 75, 311–315. [Google Scholar]
  23. Bach, B.R., Jr.; Warren, R.; Flynn, W.; Kroll, M.; Wickiewiecz, T. Arthrometric evaluation of knees that have a torn anterior cruciate ligament. J. Bone Jt. Surg. Am. 1990, 72, 1299–1306. [Google Scholar]
  24. Fleming, B.C.; Brattbakk, B.; Peura, G.D.; Badger, G.J.; Beynnon, B.D. Measurement of anterior–posterior knee laxity: A comparison of three techniques. J. Orthop. Res. 2002, 20, 421–426. [Google Scholar] [CrossRef]
  25. Forster, I.; Warren-Smith, C.; Tew, M. Is the KT1000 knee ligament arthrometer reliable? J. Bone Jt. Surg. Br. Vol. 1989, 71, 843–847. [Google Scholar]
  26. Friemert, B.; Bumann-Melnyk, M.; Faist, M.; Schwarz, W.; Gerngross, H.; Claes, L. Differentiation of hamstring short latency versus medium latency responses after tibia translation. Exp. Brain Res. 2005, 160, 1–9. [Google Scholar] [CrossRef] [PubMed]
  27. Ganko, A.; Engebretsen, L.; Ozer, H. The rolimeter: A new arthrometer compared with the KT-1000. Knee Surg. Sports Traumatol. Arthrosc. 2000, 8, 36–39. [Google Scholar] [CrossRef] [PubMed]
  28. Graham, G.P.; Johnson, S.; Dent, C.M.; Fairclough, J.A. Comparison of clinical tests and the KT1000 in the diagnosis of anterior cruciate ligament rupture. Br. J. Sports Med. 1991, 25, 96–97. [Google Scholar] [CrossRef] [PubMed]
  29. Hanten, W.P.; Pace, M.B. Reliability of measuring anterior laxity of the knee joint using a knee ligament arthrometer. Phys. Ther. 1987, 67, 357–359. [Google Scholar] [PubMed]
  30. Highgenboten, C.L.; Jackson, A.; Meske, N.B. Genucom, KT-1000, and stryker knee laxity measuring device comparisons device reproducibility and interdevice comparison in asymptomatic subjects. Am. J. Sports Med. 1989, 17, 743–746. [Google Scholar] [CrossRef] [PubMed]
  31. Hoshino, Y.; Araujo, P.; Ahlden, M.; Moore, C.G.; Kuroda, R.; Zaffagnini, S.; Karlsson, J.; Fu, F.H.; Musahl, V. Standardized pivot shift test improves measurement accuracy. Knee Surg. Sports Traumatol. Arthrosc. 2012, 20, 732–736. [Google Scholar] [CrossRef] [PubMed]
  32. Küpper, J.; Loitz-Ramage, B.; Corr, D.; Hart, D.; Ronsky, J. Measuring knee joint laxity: A review of applicable models and the need for new approaches to minimize variability. Clin. Biomech. 2007, 22, 1–13. [Google Scholar] [CrossRef] [PubMed]
  33. Kuroda, R.; Hoshino, Y.; Nagamune, K.; Kubo, S.; Nishimoto, K.; Araki, D.; Yamaguchi, M.; Yoshiya, S.; Kurosaka, M. Intraoperative measurement of pivot shift by electromagnetic sensors. Oper. Tech. Orthop. 2008, 18, 190–195. [Google Scholar] [CrossRef]
  34. Kuroda, R.; Hoshino, Y.; Araki, D.; Nishizawa, Y.; Nagamune, K.; Matsumoto, T.; Kubo, S.; Matsushita, T.; Kurosaka, M. Quantitative measurement of the pivot shift, reliability, and clinical applications. Knee Surg. Sports Traumatol. Arthrosc. 2012, 20, 686–691. [Google Scholar] [CrossRef] [PubMed]
  35. Liu, S.; Osti, L.; Henry, M.; Bocchi, L. The diagnosis of acute complete tears of the anterior cruciate ligament. Comparison of mri, arthrometry and clinical examination. J. Bone Jt. Surg. Br. Vol. 1995, 77, 586–588. [Google Scholar]
  36. Lopomo, N.; Zaffagnini, S.; Bignozzi, S.; Visani, A.; Marcacci, M. Pivot-shift test: Analysis and quantification of knee laxity parameters using a navigation system. J. Orthop. Res. 2010, 28, 164–169. [Google Scholar] [CrossRef] [PubMed]
  37. Lopomo, N.; Zaffagnini, S.; Amis, A.A. Quantifying the pivot shift test: A systematic review. Knee Surg. Sports Traumatol. Arthrosc. 2013, 21, 767–783. [Google Scholar] [CrossRef] [PubMed]
  38. Mitsou, A.; Vallianatos, P. Clinical diagnosis of ruptures of the anterior cruciate ligament: A comparison between the lachman test and the anterior drawer sign. Injury 1988, 19, 427–428. [Google Scholar] [CrossRef]
  39. Mulligan, E.P.; Harwell, J.L.; Robertson, W.J. Reliability and diagnostic accuracy of the lachman test performed in a prone position. J. Orthop. Sports Phys. Ther. 2011, 41, 749–757. [Google Scholar] [CrossRef] [PubMed]
  40. Panisset, J.C.; Ntagiopoulos, P.G.; Saggin, P.R.; Dejour, D. A comparison of Telos™ stress radiography versus Rolimeter™ in the diagnosis of different patterns of anterior cruciate ligament tears. Orthop. Traumatol. Surg. Res. 2012, 98, 751–758. [Google Scholar] [CrossRef] [PubMed]
  41. Sernert, N.; Kartus, J.; Köhler, K.; Ejerhed, L.; Karlsson, J. Evaluation of the reproducibility of the KT-1000 arthrometer. Scand. J. Med. Sci. Sports 2001, 11, 120–125. [Google Scholar] [CrossRef] [PubMed]
  42. Steiner, M.E.; Brown, C.; Zarins, B.; Brownstein, B.; Koval, P.; Stone, P. Measurement of anterior-posterior displacement of the knee. J. Bone Jt. Surg. 1990, 72, 1307–1315. [Google Scholar]
  43. Tsuda, E.; Okamura, Y.; Otsuka, H.; Komatsu, T.; Tokuya, S. Direct evidence of the anterior cruciate ligament-hamstring reflex arc in humans. Am. J. Sports Med. 2001, 29, 83–87. [Google Scholar] [PubMed]
  44. Wroble, R.R.; van Ginkel, L.A.; Grood, E.S.; Noyes, F.R.; Shaffer, B.L. Repeatability of the KT-1000 arthrometer in a normal population. Am. J. Sports Med. 1990, 18, 396–399. [Google Scholar] [CrossRef] [PubMed]
  45. Monaco, E.; Labianca, L.; Maestri, B.; de Carli, A.; Conteduca, F.; Ferretti, A. Instrumented measurements of knee laxity: KT-1000 versus navigation. Knee Surg. Sports Traumatol. Arthrosc. 2009, 17, 617–621. [Google Scholar] [CrossRef] [PubMed]
  46. Kopf, S.; Kauert, R.; Halfpaap, J.; Jung, T.; Becker, R. A new quantitative method for pivot shift grading. Knee Surg. Sports Traumatol. Arthrosc. 2012, 20, 718–723. [Google Scholar] [CrossRef] [PubMed]
  47. Gurtler, R.A.; Stine, R.; Torg, J.S. Lachman test evaluated: Quantification of a clinical observation. Clin. Orthop. Relat. Res. 1987, 216, 141–150. [Google Scholar] [CrossRef] [PubMed]
  48. Torg, J.S.; Conrad, W.; Kalen, V. Clinical I diagnosis of anterior cruciate ligament instability in the athlete. Am. J. Sports Med. 1976, 4, 84–93. [Google Scholar] [CrossRef] [PubMed]
  49. Rebman, L.W. Suggestions from the field: Lachman’s test—An alternative method. J. Orthop. Sports Phys. Ther. 1988, 9, 381–382. [Google Scholar] [CrossRef]
  50. Draper, D.O.; Schulthies, S. A test for eliminating false positive anterior cruciate ligament injury diagnoses. J. Athl. Train. 1993, 28, 355–357. [Google Scholar] [PubMed]
  51. Dussik, K. Über die möglichkeit, hochfrequente mechanische schwingungen ALS diagnostisches hilfsmittel zu verwerten. Zeitschrift Für Die Gesamte Neurologie Und Psychiatrie 1942, 174, 153–168. [Google Scholar] [CrossRef]
  52. Muller, B.; Hofbauer, M.; Rahnemai-Azar, A.A.; Wolf, M.; Araki, D.; Hoshino, Y.; Araujo, P.; Debski, R.E.; Irrgang, J.J.; Fu, F.H. Development of computer tablet software for clinical quantification of lateral knee compartment translation during the pivot shift test. Comput. Methods Biomech. Biomed. Eng. 2015, 19, 217–228. [Google Scholar] [CrossRef] [PubMed]
  53. Floyd, R.T.; Peery, D.S.; Andrews, J.R. Advantages of the prone lachman versus the traditional lachman. Orthopedics 2008, 31. [Google Scholar] [CrossRef]
  54. Galway, H.B.A.; Maclntosh, D.L. Pivot-shift: A clinical sign of symptomatic anterior cruciate defeciency. J. Bone Jt. Surg. Br. Vol. 1972, 54-B, 763–764. [Google Scholar]
  55. Kong, K.C.; Hamlet, M.R.; Peckham, T.; Mowbray, M.A.S. Displaced bucket handle tears of the medial meniscus masking anterior cruciate deficiency. Arch. Orthop. Trauma Surg. 1994, 114, 51–52. [Google Scholar] [CrossRef] [PubMed]
  56. Hoshino, Y.; Araujo, P.; Ahldén, M.; Samuelsson, K.; Muller, B.; Hofbauer, M.; Wolf, M.R.; Irrgang, J.J.; Fu, F.H.; Musahl, V. Quantitative evaluation of the pivot shift by image analysis using the ipad. Knee Surg. Sports Traumatol. Arthrosc. 2013, 21, 975–980. [Google Scholar] [CrossRef] [PubMed]
  57. Jonsson, T.; Althoff, B.; Peterson, L.; Renström, P. Clinical diagnosis of ruptures of the anterior cruciate ligament: A comparative study of the lachman test and the anterior drawer sign. Am. J. Sports Med. 1982, 10, 100–102. [Google Scholar] [CrossRef] [PubMed]
  58. Colombet, P.; Jenny, J.; Menetrey, J.; Plaweski, S.; Zaffagnini, S. Current concept in rotational laxity control and evaluation in ACL reconstruction. Orthop. Traumatol. Surg. Res. 2012, 98, S201–S210. [Google Scholar] [CrossRef] [PubMed]
  59. Scholten, R.; Opstelten, W.; van der Plas, C.G.; Bijl, D.; Deville, W.; Bouter, L.M. Accuracy of physical diagnostic tests for assessing ruptures of the anterior cruciate ligament: A meta-analysis. J. Fam. Pract. 2003, 52, 689–696. [Google Scholar] [PubMed]
  60. Cannon, W.D. Use of arthrometers to assess knee laxity and outcomes. Sports Med. Arthrosc. 2002, 10, 191–200. [Google Scholar] [CrossRef]
  61. Hirschmann, M.; Müller, W. Complex function of the knee joint: The current understanding of the knee. Knee Surg. Sports Traumatol. Arthrosc. 2015, 23, 2780–2788. [Google Scholar] [CrossRef] [PubMed]
  62. Klos, T.V.; Habets, R.J.; Banks, A.Z.; Banks, S.A.; Devilee, R.J.; Cook, F.F. Computer assistance in arthroscopic anterior cruciate ligament reconstruction. Clin. Orthop. Relat. Res. 1998, 354, 65–69. [Google Scholar] [CrossRef] [PubMed]
  63. Lopomo, N.; Bignozzi, S.; Martelli, S.; Zaffagnini, S.; Iacono, F.; Visani, A.; Marcacci, M. Reliability of a navigation system for intra-operative evaluation of antero-posterior knee joint laxity. Comput. Biol. Med. 2009, 39, 280–285. [Google Scholar] [CrossRef] [PubMed]
  64. Colombet, P.; Robinson, J.; Christel, P.; Franceschi, J.-P.; Djian, P. Using navigation to measure rotation kinematics during ACL reconstruction. Clin. Orthop. Relat. Res. 2007, 454, 59–65. [Google Scholar] [CrossRef] [PubMed]
  65. Pearle, A.D.; Solomon, D.J.; Wanich, T.; Moreau-Gaudry, A.; Granchi, C.C.; Wickiewicz, T.L.; Warren, R.F. Reliability of navigated knee stability examination a cadaveric evaluation. Am. J. Sports Med. 2007, 35, 1315–1320. [Google Scholar] [CrossRef] [PubMed]
  66. Degenhart, M. Computer-navigated ACL reconstruction with the orthopilot. Surg. Technol. Int. 2004, 12, 245–251. [Google Scholar] [PubMed]
  67. Mcquade, K.J.; Sidles, J.A.; Larson, R.V. Reliability of the genucom knee analysis system. A pilot study. Clin. Orthop. Relat. Res. 1989, 245, 216–219. [Google Scholar] [PubMed]
  68. Daniel, D.M.; Malcom, L.L.; Losse, G.; Stone, M.L.; Sachs, R.; Burks, R. Instrumented measurement of anterior laxity of the knee. J. Bone Jt. Surg. Am. 1985, 67, 720–726. [Google Scholar]
  69. Isberg, J.; Faxèn, E.; Brandsson, S.; Eriksson, B.; Kärrholm, J.; Karlsson, J. KT-1000 records smaller side-to-side differences than radiostereometric analysis before and after an ACL reconstruction. Knee Surg. Sports Traumatol. Arthrosc. 2006, 14, 529–535. [Google Scholar] [CrossRef] [PubMed]
  70. Jardin, C.; Chantelot, C.; Migaud, H.; Gougeon, F.; Debroucker, M.; Duquennoy, A. Reliability of the KT-1000 arthrometer in measuring anterior laxity of the knee: Comparative analysis with telos of 48 reconstructions of the anterior cruciate ligament and intra-and interobserver reproducibility. Rev. Chir. Orthop. Répar. Appar. Mot. 1999, 85, 698–707. [Google Scholar]
  71. Stäubli, H.-U.; Jakob, R.P. Anterior knee motion analysis measurement and simultaneous radiography. Am. J. Sports Med. 1991, 19, 172–177. [Google Scholar] [CrossRef] [PubMed]
  72. Wright, A.A.; Hegedus, E.J.; Lenchik, L.; Kuhn, K.J.; Santiago, L.; Smoliga, J.M. Diagnostic accuracy of various imaging modalities for suspected lower extremity stress fractures: A systematic review with evidence-based recommendations for clinical practice. Am. J. Sports Med. 2015. [Google Scholar] [CrossRef] [PubMed]
  73. Melnyk, M.; Gollhofer, A. Submaximal fatigue of the hamstrings impairs specific reflex components and knee stability. Knee Surg. Sports Traumatol. Arthrosc. 2007, 15, 525–532. [Google Scholar] [CrossRef] [PubMed]
  74. Jennings, A.; Seedhom, B. Proprioception in the knee and reflex hamstring contraction latency. J. Bone Jt. Surg. Br. Vol. 1994, 76, 491–494. [Google Scholar]
  75. Friemert, B.; Faist, M.; Spengler, C.; Gerngross, H.; Claes, L.; Melnyk, M. Intraoperative direct mechanical stimulation of the anterior cruciate ligament elicits short- and medium-latency hamstring reflexes. J. Neurophysiol. 2005, 94, 3996–4001. [Google Scholar] [CrossRef] [PubMed]
  76. Reiman, M.P.; Goode, A.P.; Hegedus, E.J.; Cook, C.E.; Wright, A.A. Diagnostic accuracy of clinical tests of the hip: A systematic review with meta-analysis. Br. J. Sports Med. 2012. [Google Scholar] [CrossRef] [PubMed]
  77. Rosen, A.; Ko, J.; Brown, C. Diagnostic accuracy of instrumented and manual talar tilt tests in chronic ankle instability populations. Scand. J. Med. Sci. Sports 2015, 25, e214–e221. [Google Scholar] [CrossRef] [PubMed]
  78. Reiman, M.P.; Loudon, J.K.; Goode, A.P. Diagnostic accuracy of clinical tests for assessment of hamstring injury: A systematic review. J. Orthop. Sports Phys. Ther. 2013, 43, 222–231. [Google Scholar] [CrossRef] [PubMed]
  79. Musahl, V.; Hoshino, Y.; Ahlden, M.; Araujo, P.; Irrgang, J.; Zaffagnini, S.; Karlsson, J.; Fu, F. The pivot shift: A global user guide. Knee Surg. Sports Traumatol. Arthrosc. 2012, 20, 724–731. [Google Scholar] [CrossRef] [PubMed]
  80. Rozzi, S.L.; Lephart, S.M.; Gear, W.S.; Fu, F.H. Knee joint laxity and neuromuscular characteristics of male and female soccer and basketball players. Am. J. Sports Med. 1999, 27, 312–319. [Google Scholar] [PubMed]
  81. Waldén, M.; Hägglund, M.; Werner, J.; Ekstrand, J. The epidemiology of anterior cruciate ligament injury in football (soccer): A review of the literature from a gender-related perspective. Knee Surg. Sports Traumatol. Arthrosc. 2011, 19, 3–10. [Google Scholar] [CrossRef] [PubMed]
  82. Marsh, J.D.; Birmingham, T.B.; Giffin, J.R.; Isaranuwatchai, W.; Hoch, J.S.; Feagan, B.G.; Litchfield, R.; Willits, K.; Fowler, P. Cost-effectiveness analysis of arthroscopic surgery compared with non-operative management for osteoarthritis of the knee. BMJ Open 2016, 6. [Google Scholar] [CrossRef] [PubMed]
  83. Grobbelaar, N.; Bouffard, J.A. Sonography of the knee, a pictorial review. Semin. Ultrasound CT MR 2000, 21, 231–274. [Google Scholar] [CrossRef]
Figure 1. Flow diagram of the search strategy and the study selection.
Figure 1. Flow diagram of the search strategy and the study selection.
Jfmk 01 00209 g001
Table 1. Search terms used in the databases Medline, CINHAL, EMBASE, PubMed and Cochrane from 1900 to 2015.
Table 1. Search terms used in the databases Medline, CINHAL, EMBASE, PubMed and Cochrane from 1900 to 2015.
Medline, CINHAL, EMBASE, PubMed and Cochrane
“Knee laxity”
KT-1000
KT-2000
ACL and stability
“Laxity testing” and knee
“Physical examination” and knee
“Instrumented devices” and knee
“Stability testing” and knee
Instability and knee
Imaging and knee
Lachman
Genucome
Rolimeter
“Pivot shift”
“Anterior drawer”
Table 2. Quality Assessment of Diagnostic Accuracy Studies (QUADAS) quality assessment scores of the included studies.
Table 2. Quality Assessment of Diagnostic Accuracy Studies (QUADAS) quality assessment scores of the included studies.
Authors1234567891011121314Total
Anderson and Lipscomp [19]YYYYYNYNYUYYYN10
Anderson et al. [20]YYYNYNYYNNYYYN9
Balasch et al. [21]YYYYUNYYYUYYNN9
Beard et al. [22]YYYYYYYYNN/AYYNN10
Bach et al. [23]YYYNYYYYNNYYNU9
Fleming et al. [24]YYYYNYYYYNUYNN9
Forster, Warren-Smith and Tew [25]YYYUUNYYYYYUNU8
Friemert et al. [26]YYYYNYYYYUUYYY11
Ganko, Engebretsen and Ozer [27]YYYYYNYYYUUYNU9
Graham et al. [28]YUYYYYNNNUUYYU7
Hanten and Pace [29]YYYUUYYYYNUYNU8
Highgenboten, Jackson and Meske [30]YYYUUYYNNUUYNU6
Hoshino et al. [31]YNYUUYYYNUYUUU6
Kupper et al. [32]YNYUUUUYNYUYUU5
Kuroda et al. [33]NNYUUYUYUUYYUU5
Kuroda et al. [34]YNYUUYUYUUYYUU6
Liu et al. [35]YNYYYYYNNYYYNY10
Lopomo et al. [36]YYYYYYYYYYYYUU12
Lopomo, Zaffagnini and Amis [37]YYYYNYYYYUYUYU10
Melnyk and Gollhofer [3]YYYYNYYYYYYYUU11
Mitsou and Vallianatos [38]YYNNNUUYUNNNNN3
Mulligan, Harwell and Robertson [39]YYYYUUYYUYYYYY11
Panisset et al., 2012 [40]YYYYYYYYYYYYUU12
Pugh et al. [8]YNYUUUUYNYYYUU6
Schoene et al. [11]YYYUUYYYYYUYYU10
Sernert et al. [41]YYYYYYYYYYUYYU12
Steiner et al. [42]YYYYYYYYYYUYUU11
Tsuda et al. [43]YYYUUYYUYYYYUU9
Wroble et al. [44]YNYYNNUNNNYYUU5
Barcellona et al. [10]YNYYNYYNNUUYNN6
Van Eck et al. [16]YYYYUYYYUYYYYY12
Monaco et al. [45]YUYYNYYYNYUYUU8
Kopf et al. [46]YNYUNUNYNUUYYU5
Leblanc et al. [9]YYYUYYYYYNUYYY11
Y = Yes; N = No; U = Unclear; N/A = Not Applicable; grey highlight = high quality studies;1 = was the spectrum of participants representative of the patients who will receive the test in practice;2 = were selection criteria clearly described;3 = was the reference standard likely to classify the target condition correctly;4 = was the period between the performance of the reference standard and the index test short enough to be reasonably sure that the target condition did not change between the two tests;5 = did the whole sample or a random selection of the sample receive verification using the reference standard;6 = did participants receive the same reference standard regardless of the index test result;7 = was the reference standard independent of the index test (that is, the index test did not form part of the reference standard);8 = was the execution of the index test described in sufficient detail to permit its replication;9 = was the execution of the reference standard described in sufficient detail to permit its replication;10 = were the index test results interpreted without knowledge of the results of the reference standard;11 = were the reference standard results interpreted without knowledge of the results of the index test;12 = were the same clinical data available when the test results were interpreted as would be available when the test is used in practice;13 = were uninterpretable, indeterminate or intermediate test results reported;14 = were withdrawals from the study explained.
Table 3. Summary of articles reporting on the accuracy of different anterior-posterior and rotational knee laxity measures.
Table 3. Summary of articles reporting on the accuracy of different anterior-posterior and rotational knee laxity measures.
AuthorsDevices/Technique StudiedSample SizeAge, MeanSensitivity/Specificity, p < 0.05ConclusionQUADAS Quality ScoreEffect Size
Anderson and Lipscomp [19]KT-1000, Lachman test, anterior drawer, pivot shift5019.8N/AClinical examination by an experienced examiner is the most accurate method to determine ACL integrity; however, instrumented testing was beneficial10N/A
Anderson et al. [20]KT-1000, Genucom, Acufex, Dyonics dynamic cruciate tester10026N/AThis study establishes that anterior knee laxity measurements cannot be generalized from one device to another in both normal and ACL-injured participants90.2
Bach et al. [23]KT-1000401Not mentionedAt manual maximum force (MMF), sensitivity = 79%, specificity = 77%; at 89 Newton, sensitivity = 75%, specificity = 83%KT-1000 is a helpful knee laxity measure adjunct to a careful history and physical examination of ACL-injured patients90.0
Balasch et al. [21]Rolimeter6033.6N/ARolimeter provides an economic, exact and simple operating device for quantifying anterior knee joint instability9N/A
Barcellona et al. [10]KT-20003 KT-ArthrometersN/AN/AKT-2000 knee joint arthrometers overestimates anterior displacement with a predictable relative systematic error6N/A
Beard et al. [22]Reflex Hamstring Contraction Latency (RHCL)3024.8N/AThe reflex hamstring contraction latency is a measure of proprioception and can be used to provide objective data for the management of patients with ACL deficiency101.46
Van Eck et al. [16]KT-1000, Genucom, anterior drawerReview articleN/ASensitivity of KT-1000 = 0.93, anterior drawer = 0.74; Genucom = 0,76; specificity of KT-1000 = 0.93 , anterior drawer = 0.82; Genucom = 0.76The KT arthrometer performed with maximum manual force has the highest sensitivity, specificity and accuracy for diagnosing ACL rupture12N/A
Fleming et al. [24]KT-1000, planer stress radiography, RSA1534N/AKT-1000 and RSA document temporal changes in anterior-posterior knee laxity following ACL reconstruction that were not documented by planer stress radiography90.42
Forster, Warren-Smith and Tew [25]KT-10001030N/AThe KT-1000 was not capable of overcoming result variation and providing reliable and reproducible measurement of laxity of the ACL80.8
Friemert et al. [26]Reflex Hamstring Contraction Latency (RHCL)1324.6 ± 5.5N/AShort and medium latency responses of the hamstring stretch reflex exist after an ACL stimulation during isometric hamstring contraction110.15
Ganko, Engebretsen and Ozer [27]Rolimeter3827.4Sensitivity = 89%, specificity = 95%The rolimeter, when compared to the KT-1000, provides a valid measure of anterior knee laxity90.6
Graham et al. [28]Lachman test, anterior drawer, KT-100021Not mentionedN/AAnterior drawer and the Lachman test were found to be the most accurate indicators of ACL deficiency; the KT-1000 was found to be totally inaccurate7N/A
Hanten and Pace [29]KT-10004318.5N/AOur results indicated relatively high reliability of KT-1000 and clinician can use such tool to get objective and reliable AP knee laxity measurements8N/A
Highgenboten, Jackson and Meske [30]Genucom, KT-1000, Stryker30Not mentionedN/AAll devices can provide reproducible quantitative measurements of knee laxity; however, due to differences in device sensitivities and design, numerical results from one device cannot be generalized to another device60.6
Hoshino et al. [31]Quantitative pivot shift test5Not mentionedN/AThe sudden shift of the lateral compartment of the knee joint was successfully detected by the newly-developed image analysis measurement method60
Kupper et al. [32]KT-1000, Genucom, Stryker, rolimeterReview articleN/AN/AThe development of theoretical models that accurately represent knee joint laxity in combination with more precise and repeatable clinical assessment of ACL injuries should lead to an improved understanding of joint laxity and the factors associated with acute injury and genetic pathologies that affect joint stability5N/A
Kuroda et al. [33]Pivot shift test3021.2N/AThe new non-invasive measurement system enables monitoring instantaneous 3D position displacement of the knee by using an electromagnetic sensor; these measurements can be used for quantified evaluation of dynamic instability demonstrated by the pivot shift test5N/A
Kuroda et al. [34]Quantitative pivot shift testReview articleN/AN/AAccumulative biomechanical and clinical evidence have shown the usefulness of quantitative assessment of the pivot shift test6N/A
Liu et al. [35]MRI, KT-1000, Lachman test, anterior drawer, pivot shift3826KT-1000 sensitivity = 97%, Lachman test sensitivity = 95%, MRI sensitivity = 97%; specificity for all measure was not mentionedNo significant differences between the results of the Lachman test and the KT-1000, but these were significantly better than MRI and anterior drawer; it has been shown that inexpensive tests can allow treatment to proceed rapidly and in the most economical manner without the routine use of MRI10N/A
Lopomo et al. [36]Pivot shift test1833The PS test was reliable in identifying the surgical reconstruction. Correlation analysis showed good coefficients both for pre- (r = 0.7; p < 0.05) and post-operative (r = 0.9; p < 0.05) valuesThe new quantification method of the pivot shift test could be helpful in characterizing patient-specific knee laxity, thus quantifying the clinical relevance of the test12N/A
Lopomo, Zaffagnini and Amis [37]Quantitative pivot shift testReview articleN/AN/ASeveral methodologies have been identified to quantify the pivot shift test; clinicians are still lacking the “gold standard’’ method of the quantitative pivot shift test11N/A
Melnyk and Gollhofer [3]Submaximal fatigue exercises of hamstring1525 ± 2.6N/ASubmaximal hamstring fatigue is associated with a mechanical loss of knee stability; this instability might explain at least in part a higher risk of ACL injury111
Mitsou and Vallianatos [38]Lachman test, anterior drawer144Not mentionedNot mentionedThe diagnostic accuracy of the Lachman test in recent ruptures when the patient is examined without general anaesthetic is superior to that of the anterior drawer test, while in chronic cases with third-degree instability, the two tests are equally reliable3N/A
Mulligan, Harwell and Robertson [39]Lachman test5234Sensitivity = 70%, specificity = 97%The prone Lachman test is a reliable technique that can be used to confirm the presence of an ACL tear11N/A
Panisset et al. [40]Telos, rolimeter, clinical examination17730.2 ± 11.7Sensitivity of Telos combined with CE = 88%, sensitivity of rolimeter combined with CE = 72.7; specificity of Telos combined with CE = 94.6%, specificity of rolimeter combined with CE = 92.4The combination of clinical examination with telos was more accurate than with rolimeter120.49
Pugh et al. [8]KT-1000, rolimeter, Telos, Genucom, Acufex, Dyonics dynamics cruciate tester, UCLA, VermontReview articleN/AN/AThe KT-1000 knee arthrometer and the rolimeter provide the best results when testing anterior laxity at the knee, whereas the Telos device is superior for the assessment of posterior laxity6N/A
Schoene et al. [11]Reflex Hamstring Contraction Latency (RHCL)3420N/AThe study has demonstrated that the investigated method of measuring the ACL-hamstring reflex is both reliable and reproducible100.7
Sernert et al. [41]KT-10004029Control group; sensitivity = 50%, specificity = 70% ; experimental group; sensitivity = 60%, specificity = 70%The reproducibility of the KT-1000 measurements of anterior knee laxity between two experienced examiners was considered as fair120.1
Steiner et al. [42]KT-1000, Stryker, Genucom, Acufex2825Sensitivity of Acufex = 90%, KT-1000 = 80%; Stryker = 85%; Genucom = 60%; specificity of Acufex = 85%, KT-1000 = 70%. Stryker = 70%, Genucom = 65%We recommend the use of Acufex, KT-1000 and Stryker, as they had more reproducible measurements than Genucom, as it tended to report greater differences in displacement between the right and left knees of normal participants110.2
Tsuda et al. [43]Reflex Hamstring Contraction Latency (RHCL)930N/AACL-hamstring reflex arc exists after an isometric hamstring contraction9N/A
Wroble et al. [44]KT-1000626N/AKT-1000 standard evaluation should report paired differences rather than individual knee measurements and should be supplemented by clinical examination5N/A
Monaco et al. [45]KT-1000, navigation system3029 (range 19 to 39)N/AThis study validates the accuracy of the KT-1000 to exactly calculate anterior-posterior (AP) translation of the tibia, in comparison with the more accurate measurements obtained using a navigation system80.13
Kopf et al. [46]Pivot shift test2027.8 (range 23.2 to 32.4)N/AQuantification of the pivot shift test is practicable when inertial sensors are used5N/A
Leblanc et al. [9]Lachamn, pivot shift, anterior drawer and MRIReview articleLachman, all ruptures type 89%, complete rupture 96%, partial rupture 68%; pivot shift, all rupture types 79%, complete rupture 86%, practical rupture 67%; no data for other measuresDecreased sensitivity of Lachman and pivot shift tests for partial ACL rupture cases and for awake patients raised suspicions regarding the accuracy of these tests for the diagnosis of ACL insufficiency11N/A
MMT = Manual Muscle Testing; STSD = Side-To-Side-Difference; MMF = manual maximum force; CE = Clinical Examination; PS = Pivot Shift; RSA = Roentgen Stereophotogrammetric Analysis; AP = anterior-posterior; MRI = Magnetic Resonance Image; N/A = Not Applicable; grey highlight = high quality studies.

Share and Cite

MDPI and ACS Style

Abulhasan, J.F.; Snow, M.D.; Anley, C.M.; Bakhsh, M.M.; Grey, M.J. An Extensive Evaluation of Different Knee Stability Assessment Measures: A Systematic Review. J. Funct. Morphol. Kinesiol. 2016, 1, 209-229. https://doi.org/10.3390/jfmk1020209

AMA Style

Abulhasan JF, Snow MD, Anley CM, Bakhsh MM, Grey MJ. An Extensive Evaluation of Different Knee Stability Assessment Measures: A Systematic Review. Journal of Functional Morphology and Kinesiology. 2016; 1(2):209-229. https://doi.org/10.3390/jfmk1020209

Chicago/Turabian Style

Abulhasan, Jawad F., Martyn D. Snow, Cameron M. Anley, Mohammad M. Bakhsh, and Michael J. Grey. 2016. "An Extensive Evaluation of Different Knee Stability Assessment Measures: A Systematic Review" Journal of Functional Morphology and Kinesiology 1, no. 2: 209-229. https://doi.org/10.3390/jfmk1020209

Article Metrics

Back to TopTop