Abstract

There is a growing demand for newborn sickle cell disease screening globally. Historically techniques have relied on the separation of intact haemoglobin tetramers using electrophoretic or liquid chromatography techniques. These techniques also identify haemoglobin variants of no clinical significance. Specific electrospray ionization-mass spectrometry-mass spectrometry techniques to analyse targeted peptides formed after digestion of the haemoglobin with trypsin were reported in 2005. Since this time the method has been further developed and adopted in several European countries. It is estimated that more than one million babies have been screened with no false-negative cases reported. This review reports on the current use of the technique and reviews the related publications. View Full-Text
Keywords: screening; sickle cell disease; newborn; mass spectrometry screening; sickle cell disease; newborn; mass spectrometry
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0).
SciFeed

Share & Cite This Article

MDPI and ACS Style

Daniel, Y.; Turner, C. Newborn Sickle Cell Disease Screening Using Electrospray Tandem Mass Spectrometry. Int. J. Neonatal Screen. 2018, 4, 35.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Int. J. Neonatal Screen. EISSN 2409-515X Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top