Relationships of Radiation Dose Indices with Body Size Indices in Adult Body Computed Tomography

1
Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara 252-0374, Japan
2
Department of Radiology, Kitasato University Hospital, Sagamihara 252-0375, Japan
*
Author to whom correspondence should be addressed.
Tomography 2023, 9(4), 1381-1392; https://doi.org/10.3390/tomography9040110
Submission received: 11 June 2023 / Revised: 8 July 2023 / Accepted: 12 July 2023 / Published: 14 July 2023
(This article belongs to the Section Artificial Intelligence in Medical Imaging)

Abstract

We investigated the relationships between radiation dose indices and body size indices in adult body computed tomography (CT). A total of 3200 CT scans of the thoracic, abdominal, abdominopelvic, or thoraco-abdominopelvic regions performed using one of four CT scanners were analyzed. Volume CT dose index (CTDIvol) and dose length product (DLP) were compared with various body size indices derived from CT images (water-equivalent diameter, WED; effective diameter, ED) and physical measurements (weight, weight/height, body mass index, and body surface area). CTDIvol showed excellent positive linear correlations with WED and ED. CTDIvol also showed high linear correlations with physical measurement-based indices, whereas the correlation coefficients were lower than for WED and ED. Among the physical measurement-based indices, weight/height showed the strongest correlations, followed by weight. Compared to CTDIvol, the correlation coefficients with DLP tended to be lower for WED, ED, and weight/height and higher for weight. The standard CTDIvol values at 60 kg and dose increase ratios with increasing weight, estimated using the regression equations, differed among scanners. Radiation dose indices closely correlated with body size indices such as WED, ED, weight/height, and weight. The relationships between dose and body size differed among scanners, indicating the significance of dose management considering body size.
Keywords: computed tomography; radiation dose; body size; optimization computed tomography; radiation dose; body size; optimization

Share and Cite

MDPI and ACS Style

Inoue, Y.; Itoh, H.; Nagahara, K.; Hata, H.; Mitsui, K. Relationships of Radiation Dose Indices with Body Size Indices in Adult Body Computed Tomography. Tomography 2023, 9, 1381-1392. https://doi.org/10.3390/tomography9040110

AMA Style

Inoue Y, Itoh H, Nagahara K, Hata H, Mitsui K. Relationships of Radiation Dose Indices with Body Size Indices in Adult Body Computed Tomography. Tomography. 2023; 9(4):1381-1392. https://doi.org/10.3390/tomography9040110

Chicago/Turabian Style

Inoue, Yusuke, Hiroyasu Itoh, Kazunori Nagahara, Hirofumi Hata, and Kohei Mitsui. 2023. "Relationships of Radiation Dose Indices with Body Size Indices in Adult Body Computed Tomography" Tomography 9, no. 4: 1381-1392. https://doi.org/10.3390/tomography9040110

APA Style

Inoue, Y., Itoh, H., Nagahara, K., Hata, H., & Mitsui, K. (2023). Relationships of Radiation Dose Indices with Body Size Indices in Adult Body Computed Tomography. Tomography, 9(4), 1381-1392. https://doi.org/10.3390/tomography9040110

Article Metrics

Back to TopTop