A Question of Dose? Ultra-Low Dose Chest CT on Photon-Counting CT in People with Cystic Fibrosis
Simple Summary
Abstract
1. Introduction
2. Materials and Methods
2.1. Study Population and Ethics Statement
2.2. CT Protocols and Image Acquisition
2.3. Quantitative Image Quality Analysis
2.4. Qualitative Image Quality Analysis
2.5. Radiation Dose
2.6. Statistical Analysis
3. Results
3.1. Study Population
3.2. Quantitative Image Quality Analysis
3.3. Qualitative Image Quality Analysis
3.4. Radiation Dose
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
Abbreviations
| CT | Computed tomography |
| CF | Cystic fibrosis |
| EID-CT | Energy-integrating detector CT |
| IQR | Interquartile range |
| LD-HR | Low-dose high-resolution |
| PCCT | Photon-counting CT |
| PwCF | People diagnosed with cystic fibrosis |
| ULD-HR | ultra-low-dose high-resolution |
References
- Joyce, S.; Carey, B.W.; Moore, N.; Mullane, D.; Moore, M.; McEntee, M.F.; Plant, B.J.; Maher, M.M.; O’Connor, O.J. Computed tomography in cystic fibrosis lung disease: A focus on radiation exposure. Pediatr. Radiol. 2021, 51, 544–553. [Google Scholar] [CrossRef]
- Johannesson, M.; Askling, J.; Montgomery, S.M.; Ekbom, A.; Bahmanyar, S. Cancer risk among patients with cystic fibrosis and their first-degree relatives. Int. J. Cancer 2009, 125, 2953–2956. [Google Scholar] [CrossRef]
- O’Connell, O.J.; McWilliams, S.; McGarrigle, A.; O’Connor, O.J.; Shanahan, F.; Mullane, D.; Eustace, J.; Maher, M.M.; Plant, B.J. Radiologic imaging in cystic fibrosis: Cumulative effective dose and changing trends over 2 decades. Chest 2012, 141, 1575–1583. [Google Scholar] [CrossRef] [PubMed]
- Castellani, C.; Duff, A.J.; Bell, S.C.; Heijerman, H.G.; Munck, A.; Ratjen, F.; Sermet-Gaudelus, I.; Southern, K.W.; Barben, J.; Flume, P.A.; et al. ECFS best practice guidelines: The 2018 revision. J. Cyst. Fibros. 2018, 17, 153–178. [Google Scholar] [CrossRef] [PubMed]
- Fayon, M.; Hill, K.; Waldron, M.; Messore, B.; Riberi, L.; Svedberg, M.; Lammertyn, E.; Fustik, S.; Gramegna, A.; Stahl, M.; et al. Guidance for chest-CT in children and adults with cystic fibrosis: A European perspective. Respir. Med. 2025, 241, 108076. [Google Scholar] [CrossRef]
- Ciet, P.; Bertolo, S.; Ros, M.; Casciaro, R.; Cipolli, M.; Colagrande, S.; Costa, S.; Galici, V.; Gramegna, A.; Lanza, C.; et al. State-of-the-art review of lung imaging in cystic fibrosis with recommendations for pulmonologists and radiologists from the “iMAging managEment of cySTic fibROsis” (MAESTRO) consortium. Eur. Respir. Rev. 2022, 31, 210173. [Google Scholar] [CrossRef]
- Grasemann, H.; Ratjen, F. Cystic Fibrosis. N. Engl. J. Med. 2023, 389, 1693–1707. [Google Scholar] [CrossRef]
- Ong, T.; Ramsey, B.W. Cystic fibrosis: A review. JAMA 2023, 329, 1859–1871. [Google Scholar] [CrossRef]
- Kapouni, N.; Moustaki, M.; Douros, K.; Loukou, I. Efficacy and safety of elexacaftor-tezacaftor-ivacaftor in the treatment of cystic fibrosis: A systematic review. Children 2023, 10, 554. [Google Scholar] [CrossRef]
- Turcios, N.L. Cystic fibrosis lung disease: An overview. Respir. Care 2020, 65, 233–251. [Google Scholar] [CrossRef]
- Sheahan, K.P.; O’Mahony, A.T.; Morrissy, D.; Ibrahim, H.; Crowley, C.; Waldron, M.G.; Sokol-Randell, D.; McMahon, A.; Maher, M.M.; O’Connor, O.J.; et al. Replacing plain radiograph with ultra-low dose CT thorax in cystic fibrosis (CF) in the era of CFTR modulation and its impact on cumulative effective dose. J. Cyst. Fibros. 2023, 22, 715–721. [Google Scholar] [CrossRef] [PubMed]
- Woeltjen, M.M.; Niehoff, J.H.; Michael, A.E.; Horstmeier, S.; Moenninghoff, C.; Borggrefe, J.; Kroeger, J.R. Low-dose high-resolution photon-counting CT of the lung: Radiation dose and image quality in the clinical routine. Diagnostics 2022, 12, 1441. [Google Scholar] [CrossRef]
- Frings, M.; Welsner, M.; Mousa, C.; Zensen, S.; Salhöfer, L.; Meetschen, M.; Beck, N.; Bos, D.; Westhölter, D.; Wienker, J.; et al. Low-dose high-resolution chest CT in adults with cystic fibrosis: Intraindividual comparison between photon-counting energy-integrating detector CT. Eur. Radiol. Exp. 2024, 8, 105. [Google Scholar] [CrossRef]
- Dettmer, S.; Werncke, T.; Mitkovska, V.N.; Brod, T.; Joean, O.; Vogel-Claussen, J.; Wacker, F.; Welte, T.; Rademacher, J. Photon counting computed tomography with the radiation dose of a chest X-ray: Feasibility and diagnostic yield. Respiration 2024, 103, 88–94. [Google Scholar] [CrossRef]
- Ronan, N.J.; Einarsson, G.G.; Twomey, M.; Mooney, D.; Mullane, D.; NiChroinin, M.; O’Callaghan, G.; Shanahan, F.; Murphy, D.M.; O’Connor, O.J.; et al. CORK Study in Cystic Fibrosis. Chest 2018, 153, 395–403. [Google Scholar] [CrossRef]
- Cook, T.S.; Zimmerman, S.; Maidment, A.D.; Kim, W.; Boonn, W.W. Automated extraction of radiation dose information for CT examinations. J. Am. Coll. Radiol. 2010, 7, 871–877. [Google Scholar] [CrossRef]
- A Stewart, F.; Akleyev, A.V.; Hauer-Jensen, M.; Hendry, J.H.; Kleiman, N.J.; Macvittie, T.J.; Aleman, B.M.; Edgar, A.B.; Mabuchi, K.; Muirhead, C.R.; et al. ICRP PUBLICATION 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs—Threshold doses for tissue reactions in a radiation protection context. Ann. ICRP 2012, 41, 1–322. [Google Scholar] [CrossRef]
- Dammann, F.; Momino-Traserra, E.; Remy, C.; Pereira, P.L.; Baumann, I.; Koitschev, A.; Claussen, C.D. Strahlenexposition bei der Spiral-CT der Nasennebenhöhlen. Rofo-Fortschritte Geb. Rontgenstrahlen Bildgeb. Verfahr. 2000, 172, 232–237. [Google Scholar] [CrossRef]
- Kawasaki, T.; Saito, A.; Yamazaki, H.; Ichikawa, H. Preface, Executive Summary and Glossary. Ann. ICRP 2007, 37, 9–34. [Google Scholar] [CrossRef]
- Landis, J.R.; Koch, G.G. The measurement of observer agreement for categorical data. Biometrics 1977, 33, 159. [Google Scholar] [CrossRef]
- Tækker, M.; Kristjánsdóttir, B.; Graumann, O.; Laursen, C.B.; Pietersen, P.I. Diagnostic accuracy of low-dose and ultra-low-dose CT in detection of chest pathology: A systematic review. Clin. Imaging 2021, 74, 139–148. [Google Scholar] [CrossRef]
- Suliman, I.I.; Khouqeer, G.A.; Ahmed, N.A.; Abuzaid, M.M.; Sulieman, A. Low-dose chest CT protocols for imaging COVID-19 pneumonia: Technique parameters and radiation dose. Life 2023, 13, 992. [Google Scholar] [CrossRef] [PubMed]
- Greffier, J.; Hoballah, A.; Sadate, A.; de Oliveira, F.; Claret, P.-G.; de Forges, H.; Loubet, P.; Mauboussin, J.-M.; Hamard, A.; Beregi, J.-P.; et al. Ultra-low-dose chest CT performance for the detection of viral pneumonia patterns during the COVID-19 outbreak period: A monocentric experience. Quant. Imaging Med. Surg. 2021, 11, 3190–3199. [Google Scholar] [CrossRef] [PubMed]
- Wassipaul, C.; Janata-Schwatczek, K.; Domanovits, H.; Tamandl, D.; Prosch, H.; Scharitzer, M.; Polanec, S.; Schernthaner, R.E.; Mang, T.; Asenbaum, U.; et al. Ultra-low-dose CT vs. chest X-ray in non-traumatic emergency department patients—A prospective randomised crossover cohort trial. eClinicalMedicine 2023, 65, 102267. [Google Scholar] [CrossRef]
- Mettler, F.A., Jr.; Huda, W.; Yoshizumi, T.T.; Mahesh, M. Effective doses in radiology and diagnostic nuclear medicine: A catalog. Radiology 2008, 248, 254–263. [Google Scholar] [CrossRef]
- Schegerer, A.; Loose, R.; Heuser, L.J.; Brix, G. Diagnostic reference levels for diagnostic and interventional X-ray procedures in Germany: Update and handling. Rofo-Fortschritte Geb. Rontgenstrahlen Bildgeb. Verfahr. 2019, 191, 739–751. [Google Scholar] [CrossRef]
- Dehdab, R.; Brendel, J.M.; Streich, S.; Ladurner, R.; Stenzl, B.; Mueck, J.; Gassenmaier, S.; Krumm, P.; Werner, S.; Herrmann, J.; et al. Evaluation of a deep learning denoising algorithm for dose reduction in whole-body photon-counting CT imaging: A cadaveric study. Acad. Radiol. 2025, 32, 3519–3531. [Google Scholar] [CrossRef]



| Characteristics | LD-HR | ULD-HR | p-Value |
|---|---|---|---|
| Age, years | 35.89 ± 12.48 | 33.19 ± 10.66 | 0.422 |
| Female sex, n (%) | 10 (27.78) | 20 (55.56) | 0.279 |
| Male sex, n (%) | 26 (72.22) | 16 (44.44) | |
| BMI | 21.83 ± 2.99 | 23.08 ± 4.66 | 0.236 |
| Region of Interest (Hounsfield Units) | |SNR| | ||||
|---|---|---|---|---|---|
| LD-HR | ULD-HR | LD-HR | ULD-HR | p-value (SNR) | |
| Lung | −910.72 ± 137.97 | −905.61 ± 158.86 | 6.75 ± 1.21 | 5.88 ± 1.18 | <0.001 |
| Autochthonous back muscles | 47.08 ± 157.64 | 48.92 ± 169.50 | 0.30 ± 0.09 | 0.30 ± 0.08 | 0.322 |
| Air outside the patient | −1019.50 ± 99.33 | −1024.00 ± 114.92 | 10.58 ± 2.03 | 9.30 ± 2.05 | 0.012 |
| 95% CI | Inter-Rater Reliability | ||||||
| LD-HR | ULD-HR | p-value | LD-HR | ULD-HR | LD-HR | ULD-HR | |
| Image Quality | 4 [1] | 4 [0] | <0.001 | [4.34–4.53] | [3.85–3.96] | 0.85 [0.66–1.04] | 0.67 [0.48–0.86] |
| Image Sharpness | 4 [1] | 4 [1] | <0.001 | [4.33–4.52] | [3.48–3.67] | 0.89 [0.70–1.07] | 0.83 [0.65–1.02] |
| Image Noise | 4 [0] | 3 [0] | <0.001 | [3.79–3.93] | [3.11–3.27] | 0.77 [0.58–0.96] | 0.73 [0.55–0.91] |
| Assessability of bronchi, bronchial wall thickening and bronchiolitis | 4 [1] | 4 [0] | <0.001 | [4.35–4.55] | [3.73–3.90] | 0.82 [0.63–1.00] | 0.74 [0.56–0.91] |
| LD-HR | ULD-HR | ||||||
| M.F. | H.T. | M.O. | M.F. | H.T. | M.O. | ||
| Image Quality | 4 [1] | 4 [1] | 4 [1] | 4 [0] | 4 [0] | 4 [0] | |
| Image Sharpness | 4 [1] | 4 [1] | 4 [1] | 3.5 [1] | 4 [1] | 4 [1] | |
| Image Noise | 4 [0] | 4 [0] | 4 [0] | 3 [0.5] | 3 [0] | 3 [0] | |
| Assessability of bronchi, bronchial wall thickening and bronchiolitis | 4 [1] | 4 [1] | 4 [1] | 4 [0] | 4 [0] | 4 [0] | |
| LD-HR | ULD-HR | Difference | Percentage Difference | p-Value | |
|---|---|---|---|---|---|
| CTDIvol (mGy) | 0.78 [0.19] | 0.26 [0.10] | 0.52 | 67% | <0.001 |
| DLP (mGy × cm) | 26.37 [7.81] | 8.43 [3.93] | 17.94 | 68% | <0.001 |
| Effective Dose (mSv) | 0.55 [0.08] | 0.19 [0.04] | 0.36 | 65% | <0.001 |
| Tube current (mAs) | 133.65 [35.91] | 45.95 [18.25] | 87.70 | 66% | <0.001 |
| Organ Dose (mSv) | |||||
| Lung (mSv) | 1.22 [0.20] | 0.40 [0.07] | 0.82 | 67% | <0.001 |
| Heart (mSv) | 1.14 [0.24] | 0.37 [0.07] | 0.77 | 67% | <0.001 |
| Skin (mSv) | 0.39 [0.10] | 0.14 [0.06] | 0.24 | 63% | <0.001 |
| Bones (mSv) | 0.83 [0.18] | 0.28 [0.07] | 0.55 | 66% | <0.001 |
| Esophagus (mSv) | 0.73 [0.13] | 0.25 [0.05] | 0.49 | 66% | <0.001 |
| Thymus (mSv) | 1.31 [0.27] | 0.42 [0.09] | 0.90 | 68% | <0.001 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Opitz, M.; Welsner, M.; Tazeoglu, H.I.; Stehling, F.; Sutharsan, S.; Westhölter, D.; Büscher, E.; Taube, C.; Guberina, N.; Bos, D.; et al. A Question of Dose? Ultra-Low Dose Chest CT on Photon-Counting CT in People with Cystic Fibrosis. Tomography 2025, 11, 134. https://doi.org/10.3390/tomography11120134
Opitz M, Welsner M, Tazeoglu HI, Stehling F, Sutharsan S, Westhölter D, Büscher E, Taube C, Guberina N, Bos D, et al. A Question of Dose? Ultra-Low Dose Chest CT on Photon-Counting CT in People with Cystic Fibrosis. Tomography. 2025; 11(12):134. https://doi.org/10.3390/tomography11120134
Chicago/Turabian StyleOpitz, Marcel, Matthias Welsner, Halil I. Tazeoglu, Florian Stehling, Sivagurunathan Sutharsan, Dirk Westhölter, Erik Büscher, Christian Taube, Nika Guberina, Denise Bos, and et al. 2025. "A Question of Dose? Ultra-Low Dose Chest CT on Photon-Counting CT in People with Cystic Fibrosis" Tomography 11, no. 12: 134. https://doi.org/10.3390/tomography11120134
APA StyleOpitz, M., Welsner, M., Tazeoglu, H. I., Stehling, F., Sutharsan, S., Westhölter, D., Büscher, E., Taube, C., Guberina, N., Bos, D., Drews, M., Rosok, D., Zensen, S., Haubold, J., Umutlu, L., Forsting, M., & Frings, M. (2025). A Question of Dose? Ultra-Low Dose Chest CT on Photon-Counting CT in People with Cystic Fibrosis. Tomography, 11(12), 134. https://doi.org/10.3390/tomography11120134

