Next Article in Journal
Visible Exocytosis of the Non-Photic Signal Neuropeptide Y to the Suprachiasmatic Nucleus in Fasted Transgenic Mice Throughout Their Circadian Rhythms
Next Article in Special Issue
Virtual Therapy Planning of Aortic Valve Replacement for Preventing Patient-Prosthesis Mismatch
Previous Article in Journal
Semantic-Attention Enhanced DSC-Transformer for Lymph Node Ultrasound Classification and Remote Diagnostics
Previous Article in Special Issue
The Association Between the Hemodynamics in Anomalous Origins of Coronary Arteries and Atherosclerosis: A Preliminary Case Study Based on Computational Fluid Dynamics
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Nitric Oxide Distribution Correlates with Intraluminal Thrombus in Abdominal Aortic Aneurysm: A Computational Study

1
Department of Vascular Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
2
State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100005, China
3
Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Key Laboratory of Innovation and Transformation of Advanced Medical Devices, Ministry of Industry and Information Technology, National Medical Innovation Platform for Industry-Education Integration in Advanced Medical Devices (Interdiscipline of Medicine and Engineering), School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
*
Authors to whom correspondence should be addressed.
These authors contributed equally to this work.
Bioengineering 2025, 12(2), 191; https://doi.org/10.3390/bioengineering12020191
Submission received: 18 January 2025 / Revised: 12 February 2025 / Accepted: 14 February 2025 / Published: 17 February 2025
(This article belongs to the Special Issue Computational Biofluid Dynamics)

Abstract

Intraluminal thrombus (ILT) in the abdominal aortic aneurysm (AAA) is associated with disease progression and complications. This study investigates the relationship between nitric oxide (NO) concentration and ILT in AAA patients using patient-specific computational fluid dynamics (CFD) models. Four AAA patients with ILT were enrolled. Patient-specific models of the aorta and branch arteries were constructed followed by CFD simulations. NO concentration was modeled based on endothelial shear stress response and its transport within the arterial lumen and wall. Hemodynamic parameters, including wall shear stress (WSS) and its derivatives, were analyzed alongside NO distribution. ILT accumulation was primarily located in the infrarenal abdominal aorta. Regions of decreased NO concentration correlated with ILT accumulated areas, whereas regions with decreased TAWSS and increased OSI were less consistent with ILT accumulation. A negative correlation was observed between the thrombus area and NO concentration, with p values of less than 0.001 for four patients. The time-average area NO concentration values of lumen area with ILT were lower than those of non-ILT sections. Spatially, NO was unevenly distributed, with thicker thrombus in regions of lower NO concentration. NO distribution could serve as a better potential personalized marker for thrombosis prediction in AAA compared to WSS-derived parameters.
Keywords: abdominal aortic aneurysm; intraluminal thrombus; nitric oxide; computational fluid dynamics abdominal aortic aneurysm; intraluminal thrombus; nitric oxide; computational fluid dynamics

Share and Cite

MDPI and ACS Style

Li, S.; Yang, S.; Sun, X.; Ma, T.; Zheng, Y.; Liu, X. Nitric Oxide Distribution Correlates with Intraluminal Thrombus in Abdominal Aortic Aneurysm: A Computational Study. Bioengineering 2025, 12, 191. https://doi.org/10.3390/bioengineering12020191

AMA Style

Li S, Yang S, Sun X, Ma T, Zheng Y, Liu X. Nitric Oxide Distribution Correlates with Intraluminal Thrombus in Abdominal Aortic Aneurysm: A Computational Study. Bioengineering. 2025; 12(2):191. https://doi.org/10.3390/bioengineering12020191

Chicago/Turabian Style

Li, Siting, Shiyi Yang, Xiaoning Sun, Tianxiang Ma, Yuehong Zheng, and Xiao Liu. 2025. "Nitric Oxide Distribution Correlates with Intraluminal Thrombus in Abdominal Aortic Aneurysm: A Computational Study" Bioengineering 12, no. 2: 191. https://doi.org/10.3390/bioengineering12020191

APA Style

Li, S., Yang, S., Sun, X., Ma, T., Zheng, Y., & Liu, X. (2025). Nitric Oxide Distribution Correlates with Intraluminal Thrombus in Abdominal Aortic Aneurysm: A Computational Study. Bioengineering, 12(2), 191. https://doi.org/10.3390/bioengineering12020191

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop