Next Article in Journal
Permeability Evolution of Intact and Fractured Coal during Progressive Deformation Subjected to True Triaxial Stresses
Previous Article in Journal
Optimal Dispatch of the Source-Grid-Load-Storage under a High Penetration of Photovoltaic Access to the Distribution Network
Previous Article in Special Issue
Review on Waste-to-Energy Approaches toward a Circular Economy in Developed and Developing Countries
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Reliability Evaluation of DC/DC Converter in Direct Current Collection System of Wind Farm Considering the Influence of Control Strategy

College of Electrical Engineering, Xinjiang University, Urumqi 830017, China
*
Author to whom correspondence should be addressed.
Processes 2023, 11(10), 2825; https://doi.org/10.3390/pr11102825
Submission received: 18 August 2023 / Revised: 20 September 2023 / Accepted: 23 September 2023 / Published: 25 September 2023
(This article belongs to the Special Issue The Role of Renewable Energy Systems in the Modern Societies)

Abstract

The DC collection system of wind farms can effectively solve the problems of harmonic resonance and reactive power transmission in large-scale wind power AC collection systems, and has broad development prospects. The DC/DC converter is critical equipment in the wind farm DC collection system, and its reliability is related to the entire collection system’s safe and stable operation. The reliability of DC/DC converters is affected by factors such as system operating conditions and control strategies. Based on this, a reliability evaluation model for boost full-bridge isolated (BFBIC) DC/DC converters is proposed from the device level to the submodule level and then to the equipment level, incorporating operating conditions and control strategies into reliability analysis. Firstly, in device-level reliability modeling, the impact of DC/DC converter operating conditions and control strategies on insulated gate bipolar transistor (IGBT) module losses and junction temperature fluctuations are considered. Secondly, fault tree analysis (FTA) is used to establish the reliability model of the BFBIC submodule and DC/DC converter. In the end, we verify the effectiveness of the proposed model through a numerical example, and provide solid data support for analyzing the reliability of the wind farm DC collection system.
Keywords: reliability; renewable energy sources; wind farms reliability; renewable energy sources; wind farms

Share and Cite

MDPI and ACS Style

Liu, J.; Fan, Y.; Hou, J.; Bai, X. Reliability Evaluation of DC/DC Converter in Direct Current Collection System of Wind Farm Considering the Influence of Control Strategy. Processes 2023, 11, 2825. https://doi.org/10.3390/pr11102825

AMA Style

Liu J, Fan Y, Hou J, Bai X. Reliability Evaluation of DC/DC Converter in Direct Current Collection System of Wind Farm Considering the Influence of Control Strategy. Processes. 2023; 11(10):2825. https://doi.org/10.3390/pr11102825

Chicago/Turabian Style

Liu, Junyi, Yanfang Fan, Junjie Hou, and Xueyan Bai. 2023. "Reliability Evaluation of DC/DC Converter in Direct Current Collection System of Wind Farm Considering the Influence of Control Strategy" Processes 11, no. 10: 2825. https://doi.org/10.3390/pr11102825

APA Style

Liu, J., Fan, Y., Hou, J., & Bai, X. (2023). Reliability Evaluation of DC/DC Converter in Direct Current Collection System of Wind Farm Considering the Influence of Control Strategy. Processes, 11(10), 2825. https://doi.org/10.3390/pr11102825

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop