Editorial

Chemical Sensors for Heavy Metals/Toxin Detection

Department of Chemical Science and Technologies, University “Tor Vergata”, via della Ricercha Scientifica 1, 00133 Rome, Italy
Chemosensors 2020, 8(1), 14; https://doi.org/10.3390/chemosensors8010014
Submission received: 20 February 2020 / Accepted: 21 February 2020 / Published: 22 February 2020
(This article belongs to the Special Issue Chemical Sensors for Heavy Metals/Toxin Detection)

1. Introduction

Nowadays, the huge release of pollutants into the environment has become a significant problem in many countries and entire regions. The growing industrial impact and incorrect preservation of wastes are among the main factors causing toxins and multimetal contamination. The high content of these pollutants in soil, air, and drinking water cause their consecutive accumulation in humans and this phenomenon has been connected to the insurgence of allergies, tumors, and other pathologies. This emphasizes the necessity of a careful detection and frequent analysis of heavy metals and toxins content in order to protect humans and the environment against risks caused by them. For this reason, the present Special Issue is focused on the novel achievements in analytical procedures, in terms of the development of chemical sensors and the application of related analytical methods for heavy metals and toxins assessment.

2. The Special Issue

The Special Issue contains the collection of nine original contributions: one communication, three research papers, and five reviews all dedicated to the development and application of chemical sensors for heavy metals and/or toxins detection. The contribution of Hakonen and Strömberg [1] proposes a low-cost method based on dye/ionophore/Pb2+ ions co-extraction from water phase with a further probe decolorization (and fluorescence decline) for highly sensitive in-situ lead measurements at sub-ppb levels. The review of Evtugyn and Hianik [2] describes the modern electrochemical biosensors based on immunological reactions and aptamers for the determination of mycotoxins, the most common contaminants negatively influencing human health. The contribution from the group of Prof. Riul, Jr. [3] represents a comprehensive review on the application of Electronic Tongue multisensory systems for the detection of heavy metals and toxins in water, soil, and food. Recently developed low molecular weight probes (LMFP) for fluorescence sensing of the Zn2+, Cd2+, and Hg2+ metals upon their coordination are carefully reviewed in the contribution of Prof. Wallace group [4]. The main benefits and drawbacks, as far as the future perspective of LMFP development are discussed. The review of Kuchmenko and Lvova [5] provides a selection of the last two decades publications on applications of the piezoelectric quartz resonators-based sensors and multisensory arrays for environmental monitoring and foodstuff analysis; the particular case study dedicated to the Quartz Crystal Microbalance (QCM) sensors array implementation for heavy metal ions activity evaluation in water vapors is reported. In the review of Tan, Ibsen and Tjin [6], recent efforts on optical fiber refractometer-based metal ion sensors development are reported along with the different technologies and methods involved, and notable advancements in this area are discussed.
Finally, three research articles are devoted to the development of novel sensing materials for potentiometric and optical sensors for heavy metals detection. The study of potentiometric cross-sensitive sensors with polyvinyl-chloride plasticized membranes based on modified ligands originally developed for liquid extraction is reported in the research article of Khaydukova and colleagues [7]. The possibility to vary sensitivity and selectivity patterns of sensors was shown in respect to a particular application, and for rare earth cations detection in particular. Prof. S. Kumar together with colleagues [8] reports on the selective colorimetric and fluorescence probe for Hg2+ ions detection using a benzothiazolinic spiropyran dye. The presence of mercuric ions in water was assessed through the dye disaggregation mechanism and displayed both naked eye visible color change (pink to colorless) and fluorescence response; experimental results were supported with DFT studies. The paper by Prof. Belobrov et al. [9] describes the disposable microfluidic luminescent biosensor based on enzyme inhibition for rapid assessment of heavy metals in waters with a selectivity comparable to commercial luminometers.
Of course, this research collection does not cover the whole range of advancements in the field; however, it contains new methods and ideas for metallic pollutants and toxins detection, and this will hopefully inspire further interest of scientific community to this topic and new research efforts in this area.

Conflicts of Interest

The author declares no conflict of interest.

References

  1. Hakonen, A.; Strömberg, N. Fluorescence and Naked-Eye Detection of Pb2+ in Drinking Water Using a Low-Cost Ionophore Based Sensing Scheme. Chemosensors 2018, 6, 51. [Google Scholar] [CrossRef] [Green Version]
  2. Evtugyn, G.; Hianik, T. Electrochemical Immuno- and Aptasensors for Mycotoxin Determination. Chemosensors 2019, 7, 10. [Google Scholar] [CrossRef] [Green Version]
  3. Shimizu, F.M.; Braunger, M.L.; Riul, A., Jr. Heavy Metal/Toxins Detection Using Electronic Tongues. Chemosensors 2019, 7, 36. [Google Scholar] [CrossRef] [Green Version]
  4. Johnson, A.D.; Curtis, R.M.; Wallace, K.J. Low Molecular Weight Fluorescent Probes (LMFPs) to Detect the Group 12 Metal Triad. Chemosensors 2019, 7, 22. [Google Scholar] [CrossRef] [Green Version]
  5. Kuchmenko, T.A.; Lvova, L.B. A Perspective on Recent Advances in Piezoelectric Chemical Sensors for Environmental Monitoring and Foodstuffs Analysis. Chemosensors 2019, 7, 39. [Google Scholar] [CrossRef] [Green Version]
  6. Tan, R.X.; Ibsen, M.; Tjin, S.C. Optical Fiber Refractometer Based Metal Ion Sensors. Chemosensors 2019, 7, 63. [Google Scholar] [CrossRef] [Green Version]
  7. Khaydukova, M.; Militsyn, D.; Karnaukh, M.; Grüner, B.; Selucký, P.; Babain, V.; Wilden, A.; Kirsanov, D.; Legin, A. Modified Diamide and Phosphine Oxide Extracting Compounds as Membrane Components for Cross-Sensitive Chemical Sensors. Chemosensors 2019, 7, 41. [Google Scholar] [CrossRef] [Green Version]
  8. Kumar, A.; Kumar, A.; Sahoo, P.R.; Kumar, S. Colorimetric and Fluorescence-Based Detection of Mercuric Ion Using a Benzothiazolinic Spiropyran. Chemosensors 2019, 7, 35. [Google Scholar] [CrossRef] [Green Version]
  9. Lukyanenko, K.A.; Denisov, I.A.; Sorokin, V.V.; Yakimov, A.S.; Esimbekova, E.N.; Belobrov, P.I. Handheld Enzymatic Luminescent Biosensor for Rapid Detection of Heavy Metals in Water Samples. Chemosensors 2019, 7, 16. [Google Scholar] [CrossRef] [Green Version]

Share and Cite

MDPI and ACS Style

Lvova, L. Chemical Sensors for Heavy Metals/Toxin Detection. Chemosensors 2020, 8, 14. https://doi.org/10.3390/chemosensors8010014

AMA Style

Lvova L. Chemical Sensors for Heavy Metals/Toxin Detection. Chemosensors. 2020; 8(1):14. https://doi.org/10.3390/chemosensors8010014

Chicago/Turabian Style

Lvova, Larisa. 2020. "Chemical Sensors for Heavy Metals/Toxin Detection" Chemosensors 8, no. 1: 14. https://doi.org/10.3390/chemosensors8010014

APA Style

Lvova, L. (2020). Chemical Sensors for Heavy Metals/Toxin Detection. Chemosensors, 8(1), 14. https://doi.org/10.3390/chemosensors8010014

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop