Next Article in Journal
Quantitative Detection of the Influenza a Virus by an EGOFET-Based Portable Device
Next Article in Special Issue
Semiconductor Heterojunction-AgNPs Mediated Surface-Enhanced Raman Spectroscopy (SERS) Sensor for Portable Miniaturized Detection Platform
Previous Article in Journal
Highly Polarized SERS Based on Random Working Domains Composed of Nanorod Arrays for Self-Referenced Detection
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Remote Measurements of Tear Electrolyte Concentrations on Both Sides of an Inserted Contact Lens

by
Joseph R. Lakowicz
1,*,
Ramachandram Badugu
1,
Kundan Sivashanmugan
1 and
Albert Reece
1,2
1
Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, Baltimore, MD 21201, USA
2
Department of Obstetrics, Gynecology and Reproductive Sciences, University of Maryland School of Medicine, 655 W. Baltimore St., Baltimore, MD 21201, USA
*
Author to whom correspondence should be addressed.
Chemosensors 2023, 11(8), 463; https://doi.org/10.3390/chemosensors11080463
Submission received: 20 June 2023 / Revised: 2 August 2023 / Accepted: 11 August 2023 / Published: 17 August 2023

Abstract

In this paper, a method is described to perform ion concentration measurements on both sides of an inserted contact lens, without physical contact with the eye or the contact lens. The outer surface of an eye is covered with a tear film that has multiple layers. The central aqueous layer contains electrolytes and proteins. When a contact lens is inserted, it becomes localized in the central layer, which creates two layers known as the pre-lens tear film (PLTF) and the post-lens tear film (PoLTF). The PoLTF is in direct contact with the sensitive corneal epithelial cells which control electrolyte concentrations in tears. It is difficult to measure the overall electrolyte concentration in tears because of the small 7 μL volume of bulk tears. No methods are known, and no method has been proposed, to selectively measure the concentrations of electrolytes in the smaller volumes of the PLTF and the PoLTF. In this paper, we demonstrate the ability to localize fluorophores on each side of a contact lens without probe mixing or diffusion across the lens. We measured the concentration of sodium in the region of the PoLTF using a sodium-sensitive fluorophore positioned on the inner surface of a contact lens. The fluorescence measurements do not require physical contact and are mostly independent of eye motion and fluorophore concentration. The method is generic and can be combined with ion-sensitive fluorophores for the other electrolytes in tears. Instrumentation for non-contact measurements is likely to be inexpensive with modern opto-electronic devices. We expect these lenses to be used for measurements of other ions in the PLTF and the PoLTF, and thus become useful for both research and in the diagnosis of infections, keratitis and biomarkers for diseases.
Keywords: contact lens; ion concentration; tear film; sodium-sensitive fluorophore; fluorescence sensing; tear composition; electrolytes in tears contact lens; ion concentration; tear film; sodium-sensitive fluorophore; fluorescence sensing; tear composition; electrolytes in tears
Graphical Abstract

Share and Cite

MDPI and ACS Style

Lakowicz, J.R.; Badugu, R.; Sivashanmugan, K.; Reece, A. Remote Measurements of Tear Electrolyte Concentrations on Both Sides of an Inserted Contact Lens. Chemosensors 2023, 11, 463. https://doi.org/10.3390/chemosensors11080463

AMA Style

Lakowicz JR, Badugu R, Sivashanmugan K, Reece A. Remote Measurements of Tear Electrolyte Concentrations on Both Sides of an Inserted Contact Lens. Chemosensors. 2023; 11(8):463. https://doi.org/10.3390/chemosensors11080463

Chicago/Turabian Style

Lakowicz, Joseph R., Ramachandram Badugu, Kundan Sivashanmugan, and Albert Reece. 2023. "Remote Measurements of Tear Electrolyte Concentrations on Both Sides of an Inserted Contact Lens" Chemosensors 11, no. 8: 463. https://doi.org/10.3390/chemosensors11080463

APA Style

Lakowicz, J. R., Badugu, R., Sivashanmugan, K., & Reece, A. (2023). Remote Measurements of Tear Electrolyte Concentrations on Both Sides of an Inserted Contact Lens. Chemosensors, 11(8), 463. https://doi.org/10.3390/chemosensors11080463

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop