Analysis of the Stranding Effect on the Surface Voltage Gradient of Transmission Line Conductors with Round Strands
Abstract
1. Introduction
2. Isolated Single Conductors
3. Conductor Bundles in Three-Phase Lines
4. The Surface Irregularity Factor
5. The FEA Model
6. Results
7. Conclusions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Khan, M.A.; Ghassemi, M. Corona Loss Calculation for Unconventional High Surge Impedance Loading Transmission Lines. In Proceedings of the 2023 North American Power Symposium (NAPS), Asheville, NC, USA, 15–17 October 2023. [Google Scholar] [CrossRef]
- Group, I.R.N. A Survey of Methods for Calculating Transmission Line Conductor Surface Voltage Gradients: IEEE Corona and Field Effects Subcommittee Report. IEEE Trans. Power Appar. Syst. 1979, 6, 1996–2014. [Google Scholar] [CrossRef]
- Thanassoulis, P.; Comsa, R.P. Calculation of Maximum Voltage Gradients, Part I: Bundle Conductors. IEEE Trans. Power Appar. Syst. 1971, PAS-90, 145–150. [Google Scholar] [CrossRef]
- Li, Q.; Rowland, S.M.; Shuttleworth, R. Calculating the Surface Potential Gradient of Overhead Line Conductors. IEEE Trans. Power Deliv. 2015, 30, 43–52. [Google Scholar] [CrossRef]
- Kurniawan, I.; Suwarno; Pischler, O.; Schichler, U. Audible Noise Calculation for Different Overhead Transmission Lines. In Proceedings of the 2018 53rd International Universities Power Engineering Conference (UPEC), Glasgow, UK, 4–7 September 2018. [Google Scholar] [CrossRef]
- Iyer, K.S.; Pillai, K.P.P. Analysis of Irregularity Factor of Stranded Conductors. Proc. Inst. Electr. Eng. 1968, 115, 364. [Google Scholar] [CrossRef]
- Carroll, J.B.B.; Bailey, B.M.M. Progress Report on BPA HV DC Test Line Radio Noise and Corona Loss. IEEE Trans. Power Appar. Syst. 1967, PAS-86, 1141–1145. [Google Scholar] [CrossRef]
- IEEE Std 605-2023; IEEE Guide for Bus Design in Air Insulated Substations. IEEE: New York, NY, USA, 2023.
- Glover, J.D.; Overbye, T.; Sarma, M.S. Power System Analysis and Design, 6th ed.; Cengage Learning: Boston, MA, USA, 2011. [Google Scholar]
- USDA(.gov). Design Manual for High Voltage Transmission Lines; USDA: Washington, DC, USA, 2015.
- Electric Power Research Institute. Transmission Line Reference Book 345 KV and Above; Electric Power Research Institute (EPRI): Palo Alto, CA, USA, 2014. [Google Scholar]
- Cigré Green Books. Overhead Lines; Papailiou, K.O., Ed.; Cigré Green Books: Malters, Switzerland, 2017. [Google Scholar]
- Siemens. Power Engineering Guide; Siemens AG: Erlangen, Germany, 2017. [Google Scholar]
- ABB Switchgear Manual 2006; ABB: Auburn Hills, MI, USA, 2006; p. 876.
- Kiessling, F. Overhead Power Lines: Planning, Design, Construction; Springer: Berlin/Heidelberg, Germany, 2003. [Google Scholar]
- UNE UNE EN 50182:2002; Conductors for Overhead Lines—Round Wire Concentric Lay Stranded Conductors. British Standards Institution: London, UK, 2002; pp. 1–73.
- Riba, J.-R.; Bogarra, S.; Gómez-Pau, Á.; Moreno-Eguilaz, M. Uprating of Transmission Lines by Means of HTLS Conductors for a Sustainable Growth: Challenges, Opportunities, and Research Needs. Renew. Sustain. Energy Rev. 2020, 134, 110334. [Google Scholar] [CrossRef]
- Deri, A.; Fodor, G. Influence of Geometric Parameters on the Corona Loss of 220 and 400 KV Overhead Transmission Lines. Period. Polytech. Electr. Eng. 1970, 14, 43–52. [Google Scholar]
- Bajramovic, Z.; Carsimamovic, S.; Veledar, M.; Hadzic, S.; Carsimamovic, A. Temporary Power Frequency Overvoltage in 220 KV and 400 KV Transmission Network. In Proceedings of the CIGRE C4 Colloquium on Power Quality and Lightning, Sarajevo, Bosnia and Herzegovina, 13–16 May 2012; Cigré: Sarajevo, Bosnia and Herzegovina, 2012; pp. 13–16. [Google Scholar]
- Yamazaki, K.; Olsen, R.G. Application of a Corona Onset Criterion to Calculation of Corona Onset Voltage of Stranded Conductors. IEEE Trans. Dielectr. Electr. Insul. 2004, 11, 674–680. [Google Scholar] [CrossRef]
- Peek, F.W. The Law of Corona and the Dielectric Strength of Air-II. Proc. Am. Inst. Electr. Eng. 1911, XXXI, 1051–1092. [Google Scholar] [CrossRef]
- Peek, F.W. Dielectric Phenomena in High-Voltage Engineering; McGraw-Hill Book Company, Inc.: New York, NY, USA, 1929. [Google Scholar]
- Whitehead, J.B. The Electric Strength of Air.-II. Trans. Am. Inst. Electr. Eng. 1911, 30, 1857–1887. [Google Scholar] [CrossRef]
- Stone, L.N. EHV Single and Twin Bundle Conductors–Influence of Conductor Diameter and Strand Diameter on Radio Influence Voltage and Corona Initiation Voltage. Trans. Am. Inst. Electr. Eng. Part III Power Appar. Syst. 1959, 78, 1434–1438. [Google Scholar] [CrossRef]
- Adams, G.E.E. Voltage Gradients on High-Voltage Lines. Electr. Eng. 1955, 74, 198. [Google Scholar] [CrossRef]
- Guo, D.; Li, X.; Xu, J.; Geng, Z.; Zhang, K. Dynamic Characteristics of Electric Field Distribution at SF6-Insulator Interface in DC-GIL under Polarity Reversal. Chin. J. Electr. Eng. 2025, 11, 18–28. [Google Scholar] [CrossRef]
- ANSI/NEMA ANSI/NEMA CC 1-2018; Electric Power Connection for Substations. ANSI: Washington, DC, USA, 2024; p. 45.
- Abi-Samra, N. Power Grid Resiliency for Adverse Conditions; Artech House: Norwood, MA, USA, 2017. [Google Scholar]
- Larsson, A. A Special-Case Surface Voltage Gradient Formula. IEEE Trans. Power Deliv. 1996, 11, 1771–1775. [Google Scholar] [CrossRef]
- Massaro, F. Alternating Current (AC) Resistance of Helically Stranded Conductors; Cigré: Paris, France, 2008; Volume 35, pp. 1–59. [Google Scholar]
- Riba, J.-R. The Role of AC Resistance of Bare Stranded Conductors for Developing Dynamic Line Rating Approaches. Appl. Sci. 2024, 14, 8982. [Google Scholar] [CrossRef]
- Kumar, A. Corona Effect on Transmission Lines. Int. J. Electr. Electron. Eng. Res. 2013, 3, 133–136. [Google Scholar]
- Riba, J.R. On the Accuracy of the Surface Voltage Gradient Calculation on Round Conductors Using Standard Formulas. Electr. Power Syst. Res. 2025, 247, 111794. [Google Scholar] [CrossRef]
- Xiao, F.; Zhang, B.; Deng, Y. Experimental Study on Impulse Corona Characteristics of HVDC Conductors with Space Charges. IEEE Trans. Power Deliv. 2021, 36, 1705–1713. [Google Scholar] [CrossRef]
- ABB. Electrical Transmission and Distribution Reference Book; ABB: Raleigh, NC, USA, 1997. [Google Scholar]
- Cigré. B2/B4/C1.17 Impacts of HVDC Lines on the Economics of HVDC Projects; Cigré: Paris, France, 2009. [Google Scholar]
- EPRI. EPRI AC Transmission Line Reference Book: 200 KV and Above; Electric Power Research Institute: Palo Alto, CA, USA, 2014. [Google Scholar]
- Lucas, J.R. High Voltage Engineering; University of Moratuwa: Moratuwa, Sri Lanka, 2001; p. 204. [Google Scholar]






| Conductor Configuration | Number of Wires n [-] | Wire Diameter d [mm] | Conductor Diameter D [mm] | Designation | ||
|---|---|---|---|---|---|---|
| Steel | Al | Steel | Al | |||
| #1a | 1 | 6 | 2.36 | 2.36 | 7.08 | 26-AL1/4-ST1A |
| #1b | 1 | 6 | 3.00 | 3.00 | 9.00 | 42-AL1/7-ST1A |
| #2a | 1/6 | 12 | 2.92 | 2.92 | 14.60 | 80-AL1/476-ST1A |
| #2b | 1/6 | 12 | 3.20 | 3.20 | 16.00 | 96-AL1/56-ST1A |
| #3a | 1/6 | 12/18 | 3.00 | 3.00 | 21.00 | 212-AL1/49-ST1A |
| #3b | 1/6 | 12/18 | 3.35 | 3.35 | 23.45 | 264-AL1/63-ST1A |
| #4a | 1/6 | 8/14/20 | 2.32 | 4.14 | 31.80 | 565-AL1/30-ST1A |
| #4b | 1/6 | 12/18/24 | 3.00 | 3.86 | 32.20 | 562-AL1/49-ST1A |
| Line Configuration | n [-] | h [m] | D [m] | s [cm] |
|---|---|---|---|---|
| #a | 1 | 11.18 | 7.92 | - |
| #b | 2 | 13.61 | 8.31 | 45.72 |
| #c | 3 | 14.43 | 12.19 | 45.72 |
| #d | 4 | 20.83 | 13.72 | 45.72 |
| #e | 8 | 21.34 | 15.24 | 45.72 |
| Conductor Condition | m | Reference |
|---|---|---|
| Smooth round conductor | 1 | [1,36,37,38] |
| Newly installed stranded conductors (clean, good condition) | 0.75–0.85 | Cigré, EPRI [1,28,36,37] |
| Stranded conductors with minor notches and scratches | 0.60–0.80 | Cigré, EPRI [1,36,37] |
| Stranded conductors with local visual corona | 0.72 | [38] |
| Stranded conductors with obvious visual corona | 0.82 | [38] |
| Stranded conductors (general) | 0.78 | [15] |
| Clean stranded bus conductors | 0.60–0.85 | IEEE [8] |
| Contaminated stranded bus conductors (snow, water droplets, ice, etc.) | 0.30–0.60 | IEEE [8] |
| Conductor | Stranded Conductor | Smooth Conductor | Stranded vs. Smooth m = Emax,smooth/Emax,stranded | |||||
|---|---|---|---|---|---|---|---|---|
| h [m] | Eaverage | Emax | Eaverage/Emax | Eaverage | Emax | Eaverage/Emax | ||
| #1a | 5 | 0.270 | 0.497 | 0.543 | 0.354 | 0.356 | 0.994 | 0.716 |
| #1b | 5 | 0.239 | 0.404 | 0.592 | 0.288 | 0.288 | 1.000 | 0.713 |
| #2a | 5 | 0.133 | 0.266 | 0.500 | 0.189 | 0.190 | 0.995 | 0.714 |
| #2b | 5 | 0.111 | 0.246 | 0.451 | 0.175 | 0.175 | 1.000 | 0.711 |
| #3a | 5 | 0.099 | 0.197 | 0.503 | 0.139 | 0.139 | 1.000 | 0.706 |
| #3b | 5 | 0.090 | 0.179 | 0.503 | 0.126 | 0.126 | 1.000 | 0.704 |
| #4a | 5 | 0.063 | 0.137 | 0.460 | 0.0974 | 0.0977 | 0.997 | 0.713 |
| #4b | 5 | 0.074 | 0.132 | 0.561 | 0.0964 | 0.0967 | 0.997 | 0.733 |
| Conductor | Stranded Conductor | Smooth Conductor | Stranded vs. Smooth m | |||||
| h [m] | Eaverage | Emax | Eaverage/Emax | Eaverage | Emax | Eaverage/Emax | ||
| #1a | 10 | 0.247 | 0.455 | 0.543 | 0.325 | 0.326 | 0.997 | 0.716 |
| #1b | 10 | 0.219 | 0.370 | 0.592 | 0.262 | 0.263 | 0.997 | 0.711 |
| #2a | 10 | 0.121 | 0.242 | 0.500 | 0.172 | 0.172 | 1.000 | 0.711 |
| #2b | 10 | 0.101 | 0.223 | 0.453 | 0.159 | 0.159 | 1.000 | 0.713 |
| #3a | 10 | 0.090 | 0.178 | 0.506 | 0.125 | 0.125 | 1.000 | 0.702 |
| #3b | 10 | 0.081 | 0.161 | 0.503 | 0.114 | 0.114 | 1.000 | 0.708 |
| #4a | 10 | 0.057 | 0.123 | 0.463 | 0.088 | 0.088 | 1.000 | 0.715 |
| #4b | 10 | 0.066 | 0.118 | 0.559 | 0.087 | 0.087 | 1.000 | 0.737 |
| Conductor | Stranded Conductor | Smooth Conductor | Stranded vs. Smooth m | |||||
| h [m] | Eaverage | Emax | Eaverage/Emax | Eaverage | Emax | Eaverage/Emax | ||
| #1a | 20 | 0.226 | 0.415 | 0.544 | 0.296 | 0.297 | 0.997 | 0.716 |
| #1b | 20 | 0.199 | 0.336 | 0.592 | 0.239 | 0.239 | 1.000 | 0.711 |
| #2a | 20 | 0.111 | 0.220 | 0.505 | 0.156 | 0.156 | 1.000 | 0.709 |
| #2b | 20 | 0.091 | 0.202 | 0.450 | 0.144 | 0.144 | 1.000 | 0.713 |
| #3a | 20 | 0.081 | 0.160 | 0.506 | 0.113 | 0.113 | 1.000 | 0.706 |
| #3b | 20 | 0.073 | 0.145 | 0.503 | 0.102 | 0.102 | 1.000 | 0.703 |
| #4a | 20 | 0.051 | 0.111 | 0.459 | 0.078 | 0.078 | 1.000 | 0.703 |
| #4b | 20 | 0.059 | 0.106 | 0.557 | 0.078 | 0.078 | 1.000 | 0.736 |
| Line | Stranded Conductor Center Phase | Smooth Conductor Center Phase | Stranded vs. Smooth Center Phase Emax,stranded/Emax,smooth | |||||
|---|---|---|---|---|---|---|---|---|
| h [m] | Eaverage | Emax | Eaverage/Emax | Eaverage | Emax | Eaverage/Emax | ||
| #a | 11.18 | 0.283 | 0.520 | 0.544 | 0.371 | 0.372 | 0.997 | 0.715 |
| #b | 13.61 | 0.207 | 0.386 | 0.536 | 0.271 | 0.276 | 0.982 | 0.715 |
| #c | 14.43 | 0.146 | 0.281 | 0.520 | 0.192 | 0.203 | 0.946 | 0.722 |
| #d | 20.83 | 0.124 | 0.235 | 0.528 | 0.161 | 0.166 | 0.970 | 0.706 |
| #e | 21.34 | 0.082 | 0.150 | 0.547 | 0.102 | 0.106 | 0.962 | 0.707 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Riba, J.-R. Analysis of the Stranding Effect on the Surface Voltage Gradient of Transmission Line Conductors with Round Strands. Technologies 2026, 14, 255. https://doi.org/10.3390/technologies14050255
Riba J-R. Analysis of the Stranding Effect on the Surface Voltage Gradient of Transmission Line Conductors with Round Strands. Technologies. 2026; 14(5):255. https://doi.org/10.3390/technologies14050255
Chicago/Turabian StyleRiba, Jordi-Roger. 2026. "Analysis of the Stranding Effect on the Surface Voltage Gradient of Transmission Line Conductors with Round Strands" Technologies 14, no. 5: 255. https://doi.org/10.3390/technologies14050255
APA StyleRiba, J.-R. (2026). Analysis of the Stranding Effect on the Surface Voltage Gradient of Transmission Line Conductors with Round Strands. Technologies, 14(5), 255. https://doi.org/10.3390/technologies14050255