Next Article in Journal
A Three-Level Service Quality Index System for Wind Turbine Groups Based on Fuzzy Comprehensive Evaluation
Next Article in Special Issue
Formal Verification of Code Conversion: A Comprehensive Survey
Previous Article in Journal
Breaking Barriers: The Design and Development of an Assistive Technology Web App for Older Latinos with Disabilities in Daily Activities
Previous Article in Special Issue
Revolutionary Integration of Artificial Intelligence with Meta-Optics-Focus on Metalenses for Imaging
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Influence of Insulin Pen Needle Geometry on Pain Perception and Patient’s Acceptability: A Review

by
Francesca De Tommasi
1,2,* and
Sergio Silvestri
1
1
Unit of Measurement and Biomedical Instrumentation, Departmental Faculty of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy
2
Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128 Rome, Italy
*
Author to whom correspondence should be addressed.
Technologies 2024, 12(11), 233; https://doi.org/10.3390/technologies12110233
Submission received: 25 July 2024 / Revised: 25 October 2024 / Accepted: 5 November 2024 / Published: 19 November 2024
(This article belongs to the Collection Review Papers Collection for Advanced Technologies)

Abstract

Diabetes is one of the most common diseases worldwide, with an increasing number of people affected. Insulin therapy is still the major treatment for both Type 1 and Type 2 diabetes and has evolved from bulky syringes to modern insulin pens introduced in 1985. An insulin pen consists of three major parts: a cartridge, a single-use pen needle (PN), and a precision dosing mechanism. Initially, PNs were long and thick, causing great discomfort and concern. Thanks to advances in design, shorter and thinner needles have appeared on the market, improving patient acceptability and pain perception. Studies highlight the influence of PN geometry and other characteristics on injection-related pain, including length, diameter, bevel design, and hub. Despite a lack of specific international regulations for PN geometry, scientific publications have focused on exploring different PNs’ characteristics to optimize patient comfort and reduce pain. To guide the selection of suitable PNs, this review provides a round-up of literature research findings on the impact of PN geometry on pain perception and patient acceptability. Specifically, it provides an overview of the PN manufacturing process, current international regulations, and the state-of-the-art research on PN geometry affecting pain perception.
Keywords: diabetes; injection-related pain; insulin therapy; pen needles diabetes; injection-related pain; insulin therapy; pen needles

Share and Cite

MDPI and ACS Style

De Tommasi, F.; Silvestri, S. Influence of Insulin Pen Needle Geometry on Pain Perception and Patient’s Acceptability: A Review. Technologies 2024, 12, 233. https://doi.org/10.3390/technologies12110233

AMA Style

De Tommasi F, Silvestri S. Influence of Insulin Pen Needle Geometry on Pain Perception and Patient’s Acceptability: A Review. Technologies. 2024; 12(11):233. https://doi.org/10.3390/technologies12110233

Chicago/Turabian Style

De Tommasi, Francesca, and Sergio Silvestri. 2024. "Influence of Insulin Pen Needle Geometry on Pain Perception and Patient’s Acceptability: A Review" Technologies 12, no. 11: 233. https://doi.org/10.3390/technologies12110233

APA Style

De Tommasi, F., & Silvestri, S. (2024). Influence of Insulin Pen Needle Geometry on Pain Perception and Patient’s Acceptability: A Review. Technologies, 12(11), 233. https://doi.org/10.3390/technologies12110233

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop