Next Article in Journal
Implementation of a Prediction Model in a Smart System for Enhancing Comfort in Dwellings
Previous Article in Journal
Facial Wrinkle Detection with Multiscale Spatial Feature Fusion Based on Image Enhancement and ASFF-SEUnet
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A Novel Contactless Blood Pressure Measurement System and Algorithm Based on Vision Intelligence

1
Department of Computer Engineering, Keimyung University, Daegu 42601, Republic of Korea
2
Department of Biomedical Engineering, Keimyung University, Daegu 42601, Republic of Korea
*
Author to whom correspondence should be addressed.
Electronics 2023, 12(24), 4898; https://doi.org/10.3390/electronics12244898
Submission received: 9 November 2023 / Revised: 3 December 2023 / Accepted: 4 December 2023 / Published: 5 December 2023
(This article belongs to the Section Computer Science & Engineering)

Abstract

The measurement of vital signs such as blood pressure plays a key role in human health. Usually, we encounter some problems when we check them in the traditional way; for example, it is impossible to check continuously, and measuring vital signs requires direct contact with the patient, which can be uncomfortable for certain individuals. In this research, we present a vision-based system for estimating blood pressure using pulse transit time (PTT) and the Eulerian video magnification (EVM) technique to amplify tiny color variations caused by blood flow to calculate arterial pulse waves traveling between two arterial sites. Calculating the PTT by processing the video signal for each subject, an oscillometer BP device was used to evaluate the performance between measurements in different conditions, including rest, exercise, and during recovery. Mean systolic BP was 115 mmHg at rest, 137 mmHg during high-intensity exercise, and 114 mmHg during recovery, respectively. The average value of diastolic blood pressure did not change significantly before, during, and after exercise. When we compared the systolic and diastolic blood pressure with ground-truth results, our system showed an accuracy of 91% for systolic blood pressure and 90% for diastolic blood pressure.
Keywords: pulse transit time (PTT); blood pressure monitoring; video processing; non-invasive; signal processing pulse transit time (PTT); blood pressure monitoring; video processing; non-invasive; signal processing

Share and Cite

MDPI and ACS Style

Khomidov, M.; Lee, D.; Lee, J.-H. A Novel Contactless Blood Pressure Measurement System and Algorithm Based on Vision Intelligence. Electronics 2023, 12, 4898. https://doi.org/10.3390/electronics12244898

AMA Style

Khomidov M, Lee D, Lee J-H. A Novel Contactless Blood Pressure Measurement System and Algorithm Based on Vision Intelligence. Electronics. 2023; 12(24):4898. https://doi.org/10.3390/electronics12244898

Chicago/Turabian Style

Khomidov, Mavlonbek, Deokwoo Lee, and Jong-Ha Lee. 2023. "A Novel Contactless Blood Pressure Measurement System and Algorithm Based on Vision Intelligence" Electronics 12, no. 24: 4898. https://doi.org/10.3390/electronics12244898

APA Style

Khomidov, M., Lee, D., & Lee, J.-H. (2023). A Novel Contactless Blood Pressure Measurement System and Algorithm Based on Vision Intelligence. Electronics, 12(24), 4898. https://doi.org/10.3390/electronics12244898

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop