Next Article in Journal
Molybdenum Can Regulate the Expression of Molybdase Genes, Affect Molybdase Activity and Metabolites, and Promote the Cell Wall Bio-Synthesis of Tobacco Leaves
Previous Article in Journal
Morphology and Immunoexpression of Selenoproteins in Term Placenta of Alpaca (Vicugna pacos) from the Peruvian Andes
Previous Article in Special Issue
Aging Increases Enterocyte Damage during a 3-Hour Exposure to Very Hot and Dry Heat: A Preliminary Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Kuklane et al. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology 2022, 11, 1813

1
Team Fire Service Science, Netherlands Academy of Crisis Management and Fire Service Science, Netherlands Institute for Public Safety, Zilverstraat 91, 2718 RP Zoetermeer, The Netherlands
2
Division of Ergonomics and Aerosol Technology, Department of Design Sciences, Lund University, Box 118, 22100 Lund, Sweden
3
Team COLS, Netherlands Institute for Public Safety, Zilverstraat 91, 2718 RP Zoetermeer, The Netherlands
*
Author to whom correspondence should be addressed.
Biology 2025, 14(1), 65; https://doi.org/10.3390/biology14010065
Submission received: 12 December 2024 / Accepted: 30 December 2024 / Published: 14 January 2025
(This article belongs to the Special Issue Effects of Environmental Factors on Human Health and Performance)

Error in Appendix A, Table A1

The original publication contained an erroneous data line in Appendix A, “Table A1. Clothing ensembles’ local and regional clothing insulation values (IT,i, IT,z,i, m2K/W)” [1]. The data line for ensemble C4 was mistakenly the same as for the air layer (AL). The error occurred due to uncorrected linking to the individual test files. Complete Table A1 with correct data for ensemble C4 is presented below. The authors apologize for any inconvenience caused and state that the scientific conclusions are unaffected as the annex was only intended as supplementary material with local insulation data.
Table A1. Clothing ensembles’ local and regional clothing insulation values (IT,i, IT,z,i, m2K/W).
Table A1. Clothing ensembles’ local and regional clothing insulation values (IT,i, IT,z,i, m2K/W).
CodeHeadChestBackAbdomenButtocksTorsoUpper ArmsLower ArmsArmsHandsThighsCalvesLegsFeetHead, Hands and Feet Excluded
AL0.1060.1130.0970.0950.0760.0970.1190.1050.1130.1010.0970.0820.0900.1080.097
C10.1010.2790.2510.3040.2670.2630.2110.1040.1560.1010.2300.1740.2010.2640.207
C1A0.0980.4130.3880.4690.4720.4190.3600.2320.3020.1000.2550.1860.2220.2680.294
C1B0.1050.4510.4050.5200.4980.4480.3680.2440.3120.1030.2600.1910.2270.2700.305
C20.1010.2380.2140.3290.2850.2460.2780.2050.2470.1170.2460.1790.2140.2670.233
C2A0.0990.3870.3470.5310.4380.3970.3850.2780.3370.1100.2540.1750.2150.2660.292
C2B0.0980.3890.3570.5260.4550.4040.3940.2870.3450.1220.2530.1740.2140.2730.294
C2C0.1010.4560.4250.6390.5740.4800.4110.2950.3600.1120.2450.2080.2280.2850.321
C2D0.1550.4680.3420.5970.5000.4310.4350.3380.3910.1230.2480.2060.2280.2820.317
C2E0.2110.4610.3400.5970.4960.4270.4390.3380.3940.1240.2480.2050.2280.2840.316
C2F0.1660.5810.5080.6800.6800.5770.6020.4840.5500.1210.2420.2090.2260.2740.361
C2G0.1570.6260.5540.7420.7020.6230.6240.4890.5600.1360.2450.2060.2270.2840.370
C30.1010.2800.2480.4430.4530.3020.3290.2610.2990.1550.2410.1800.2110.2750.259
C3A0.1430.2690.2320.4270.4110.2860.3140.2380.2800.1520.2310.2020.2180.2680.255
C3B0.1450.4140.3780.6010.5980.4420.4100.2970.3580.1230.2490.2190.2350.2720.319
C40.2760.7060.6090.7640.6010.6600.5260.4140.4800.2590.6180.4340.5280.3540.560
C50.2070.6700.5340.5850.5290.5810.5510.3890.4800.2620.5450.4390.4970.3410.523
C60.2070.7300.5290.7930.7640.6570.5780.4190.5060.2590.6020.4210.5140.3450.560
C6A0.2810.6440.5420.7300.6220.6140.5220.3920.4660.2640.6130.4250.5210.3480.539
C6B0.3150.6540.5200.7220.6080.6030.5200.4020.4700.2800.6310.4320.5330.3520.542
C6C0.2720.6420.5490.7200.5790.6070.5000.4130.4620.2580.5970.4180.5100.3420.531
C70.2070.8120.6230.8420.7830.7350.5350.4190.4850.2550.6130.4260.5210.3500.578
C80.1980.6260.4540.7170.7340.5760.4710.3870.4370.2500.5850.4240.5070.3440.513
C90.1550.5450.4110.7770.7720.5370.4010.3490.3790.1550.5650.4260.4990.3400.478
C9A0.1530.6640.4470.7960.7340.5900.4790.3900.4410.1470.5860.4330.5140.3510.521
C9B0.1540.6380.4360.7270.7770.5740.4680.3880.4350.2470.5900.4260.5110.3480.513

Reference

  1. Kuklane, K.; Eggeling, J.; Kemmeren, M.; Heus, R. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology 2022, 11, 1813. [Google Scholar] [CrossRef] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Kuklane, K.; Eggeling, J.; Kemmeren, M.; Heus, R. Correction: Kuklane et al. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology 2022, 11, 1813. Biology 2025, 14, 65. https://doi.org/10.3390/biology14010065

AMA Style

Kuklane K, Eggeling J, Kemmeren M, Heus R. Correction: Kuklane et al. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology 2022, 11, 1813. Biology. 2025; 14(1):65. https://doi.org/10.3390/biology14010065

Chicago/Turabian Style

Kuklane, Kalev, Jakob Eggeling, Maurice Kemmeren, and Ronald Heus. 2025. "Correction: Kuklane et al. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology 2022, 11, 1813" Biology 14, no. 1: 65. https://doi.org/10.3390/biology14010065

APA Style

Kuklane, K., Eggeling, J., Kemmeren, M., & Heus, R. (2025). Correction: Kuklane et al. A Database of Static Thermal Insulation and Evaporative Resistance Values of Dutch Firefighter Clothing Items and Ensembles. Biology 2022, 11, 1813. Biology, 14(1), 65. https://doi.org/10.3390/biology14010065

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop