Next Article in Journal
Experimental Study of the Influence of Deposition of Multilayer CrN/CrCN PVD Coating on Austenitic Steel on Resistance to Cavitation Erosion
Previous Article in Journal
A Comprehensive Numerical Study on Friction Reduction and Wear Resistance by Surface Coating on Cam/Tappet Pairs under Different Conditions
Previous Article in Special Issue
In Vitro Activity Assays of Sputtered HAp Coatings with SiC Addition in Various Simulated Biological Fluids
Open AccessArticle

Comparison of the Clinical Results of Identically Designed Total Knee Prostheses with Different Surface Roughnesses

Department of Orthopaedic Surgery, School of Medicine, Inha University, Incheon 22332, Korea
*
Author to whom correspondence should be addressed.
Coatings 2020, 10(5), 486; https://doi.org/10.3390/coatings10050486
Received: 1 May 2020 / Revised: 13 May 2020 / Accepted: 14 May 2020 / Published: 19 May 2020
(This article belongs to the Special Issue Surface Modification of Medical Implants)
The purpose of this study was to investigate the effects of the undersurface roughness of total knee prosthesis on clinical outcomes. We compared the clinical and radiological outcomes and prosthesis survivals in patients who underwent total knee arthroplasty using prosthesis with identical designs but different surface roughness (average surface roughnesses (Ra), 5.0 μm vs. 11.6 μm). The results showed that the knee prostheses with a more roughened undersurface (Ra = 11.6 μm) produced significantly better functional results and enhanced prosthesis survival. The difference in surface roughness was associated with incidence of osteolysis and loosening at the tibial baseplate, but not at the femoral component. Overall, our results provided significant evidence that the use of roughened undersurface of tibial baseplate would be a way to prevent aseptic loosening. View Full-Text
Keywords: knee; osteoarthritis; total knee arthroplasty; surface roughness; loosening; implant-cement interface knee; osteoarthritis; total knee arthroplasty; surface roughness; loosening; implant-cement interface
Show Figures

Figure 1

MDPI and ACS Style

Ko, S.H.; Moon, K.H. Comparison of the Clinical Results of Identically Designed Total Knee Prostheses with Different Surface Roughnesses. Coatings 2020, 10, 486.

Show more citation formats Show less citations formats
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.