Lipid Layer Thickness in Soft Contact Lens Wearers With and Without Lenses In Situ—A Systematic Review and Meta-Analysis
Abstract
1. Introduction
2. Materials and Methods
2.1. Study Selection
Study Group
2.2. Statistical Analysis
3. Results
3.1. Risk-of-Bias Assessment
3.2. Trim-and-Fill Method
4. Discussion
4.1. Perspectives on Contact Lens Development, Surface Modifications, and Complementary Therapies
4.2. Limitations of the Study
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Bron, A.J.; Tiffany, J.M.; Gouveia, S.M.; Yokoi, N.; Voon, L.W. Functional aspects of the tear film lipid layer. Exp. Eye Res. 2004, 78, 347–360. [Google Scholar] [CrossRef]
- Montés-Micó, R. Role of the tear film in the optical quality of the human eye. J. Cataract. Refract. Surg. 2007, 33, 1631–1635. [Google Scholar] [CrossRef]
- Bron, A.J.; de Paiva, C.S.; Chauhan, S.K.; Bonini, S.; Gabison, E.E.; Jain, S.; Knop, E.; Markoulli, M.; Ogawa, Y.; Perez, V.; et al. TFOS DEWS II pathophysiology report. Ocul. Surf. 2017, 15, 438–510. [Google Scholar] [CrossRef]
- Wolffsohn, J.S.; Lingham, G.; Downie, L.E.; Huntjens, B.; Inomata, T.; Jivraj, S.; Kobia-Acquah, E.; Muntz, A.; Mohamed-Noriega, K.; Plainis, S.; et al. TFOS Lifestyle: Impact of the digital environment on the ocular surface. Ocul. Surf. 2023, 28, 213–252. [Google Scholar] [CrossRef]
- Craig, J.P.; Nelson, J.D.; Azar, D.T.; Belmonte, C.; Bron, A.J.; Chauhan, S.K.; de Paiva, C.S.; Gomes, J.A.P.; Hammitt, K.M.; Jones, L.; et al. TFOS DEWS II Report Executive Summary. Ocul. Surf. 2017, 15, 802–812. [Google Scholar] [CrossRef] [PubMed]
- Craig, J.P.; Tomlinson, A. Importance of the lipid layer in human tear film stability and evaporation. Optom. Vis. Sci. 1997, 74, 8–13. [Google Scholar] [CrossRef]
- King-Smith, P.E.; Hinel, E.A.; Nichols, J.J. Application of a novel interferometric method to investigate the relation between lipid layer thickness and tear film thinning. Investig. Ophthalmol. Vis. Sci. 2010, 51, 2418–2423. [Google Scholar] [CrossRef]
- Patel, S.; Mittal, R.; Kumar, N.; Galor, A. The environment and dry eye—Manifestations, mechanisms, and more. Front. Toxicol. 2023, 5, 1173683. [Google Scholar] [CrossRef] [PubMed]
- Dietrich, J.; Garreis, F.; Paulsen, F. Pathophysiology of Meibomian Glands–An Overview. Ocul. Immunol. Inflamm. 2021, 29, 803–810. [Google Scholar] [CrossRef]
- Guillon, J.P. Non-invasive tearscope plus routine for contact lens fitting. Contact Lens Anterior Eye 1998, 21, S31–S40. [Google Scholar] [CrossRef]
- Best, N.; Drury, L.; Wolffsohn, J.S. Clinical evaluation of the Oculus Keratograph. Contact Lens Anterior Eye 2012, 35, 171–174. [Google Scholar] [CrossRef]
- Sánchez-González, M.C.; Capote-Puente, R.; García-Romera, M.C.; De-Hita-Cantalejo, C.; Bautista-Llamas, M.J.; Silva-Viguera, C.; Sánchez-González, J.M. Dry eye disease and tear film assessment through a novel non-invasive ocular surface analyzer: The OSA protocol. Front. Med. 2022, 9, 938484. [Google Scholar] [CrossRef]
- Esam, S.; Singh, S.; Konda, N.; Gandhi, R.; Vemuganti, G.K. Tear Film Lipid Layer Thickness: Measurement Techniques, Normative Values and Alteration in Ocular Surface Diseases. Curr. Eye Res. 2025, 1–15. [Google Scholar] [CrossRef]
- Finis, D.; Pischel, N.; Schrader, S.; Geerling, G. Evaluation of lipid layer thickness measurement of the tear film as a diagnostic tool for Meibomian gland dysfunction. Cornea 2013, 32, 1549–1553. [Google Scholar] [CrossRef]
- Lee, J.M.; Jeon, Y.J.; Kim, K.Y.; Hwang, K.Y.; Kwon, Y.A.; Koh, K. Ocular surface analysis: A comparison between the LipiView® II and IDRA®. Eur. J. Ophthalmol. 2021, 31, 2300–2306. [Google Scholar] [CrossRef] [PubMed]
- Rinert, J.; Branger, G.; Bachmann, L.M.; Pfaeffli, O.; Iselin, K.; Kaufmann, C.; Thiel, M.A.; Baenninger, P.B. Accuracy of a New Noninvasive Automatic Ocular Surface Analyzer for the Diagnosis of Dry Eye Disease-Two-Gate Design Using Healthy Controls. Cornea 2023, 42, 416–422. [Google Scholar] [CrossRef] [PubMed]
- Alves, M.; Asbell, P.; Dogru, M.; Giannaccare, G.; Grau, A.; Gregory, D.; Kim, D.H.; Marini, M.C.; Ngo, W.; Nowinska, A.; et al. TFOS Lifestyle Report: Impact of environmental conditions on the ocular surface. Ocul. Surf. 2023, 29, 1–52. [Google Scholar] [CrossRef] [PubMed]
- Gomes, J.A.P.; Azar, D.T.; Baudouin, C.; Bitton, E.; Chen, W.; Hafezi, F.; Hamrah, P.; Hogg, R.E.; Horwath-Winter, J.; Kontadakis, G.A.; et al. TFOS Lifestyle: Impact of elective medications and procedures on the ocular surface. Ocul. Surf. 2023, 29, 331–385. [Google Scholar] [CrossRef]
- Stapleton, F.; Abad, J.C.; Barabino, S.; Burnett, A.; Iyer, G.; Lekhanont, K.; Li, T.; Liu, Y.; Navas, A.; Obinwanne, C.J.; et al. TFOS Lifestyle: Impact of societal challenges on the ocular surface. Ocul. Surf. 2023, 28, 165–199. [Google Scholar] [CrossRef]
- Galor, A.; Britten-Jones, A.C.; Feng, Y.; Ferrari, G.; Goldblum, D.; Gupta, P.K.; Merayo-Lloves, J.; Na, K.S.; Naroo, S.A.; Nichols, K.K.; et al. TFOS Lifestyle: Impact of lifestyle challenges on the ocular surface. Ocul. Surf. 2023, 28, 262–303. [Google Scholar] [CrossRef]
- Giannaccare, G.; Vigo, L.; Pellegrini, M.; Sebastiani, S.; Carones, F. Ocular Surface Workup with Automated Noninvasive Measurements for the Diagnosis of Meibomian Gland Dysfunction. Cornea 2018, 37, 740–745. [Google Scholar] [CrossRef]
- Craig, J.P.; Willcox, M.D.P.; Argüeso, P.; Maissa, C.; Stahl, U.; Tomlinson, A.; Wang, J.; Yokoi, N.; Stapleton, F. The TFOS International Workshop on Contact Lens Discomfort: Report of the Contact Lens Interactions with the Tear Film Subcommittee. Investig. Ophthalmol. Vis. Sci. 2013, 54, TFOS123–TFOS156. [Google Scholar] [CrossRef]
- Stapleton, F.; Bakkar, M.; Carnt, N.; Chalmers, R.; Vijay, A.K.; Marasini, S.; Ng, A.; Tan, J.; Wagner, H.; Woods, C.; et al. BCLA CLEAR-Contact lens complications. Contact Lens Anterior Eye 2021, 44, 330–367. [Google Scholar] [CrossRef]
- Varikooty, J.; Keir, N.; Simpson, T. Estimating tear film spread and stability through tear hydrodynamics. Optom. Vis. Sci. 2012, 89, E1119–E1124. [Google Scholar] [CrossRef]
- Yokoi, N.; Yamada, H.; Mizukusa, Y.; Bron, A.J.; Tiffany, J.M.; Kato, T.; Kinoshita, S. Rheology of Tear Film Lipid Layer Spread in Normal and Aqueous Tear–Deficient Dry Eyes. Investig. Ophthalmol. Vis. Sci. 2008, 49, 5319–5324. [Google Scholar] [CrossRef]
- Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ 2021, 372, n71. [Google Scholar] [CrossRef]
- Page, M.J.; Moher, D.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. PRISMA 2020 explanation and elaboration: Updated guidance and exemplars for reporting systematic reviews. BMJ 2021, 372, n160. [Google Scholar] [CrossRef]
- Kumar, M.; Masoudi, S.; Vijay, A.K.; Naduvilath, T.J.; Dumpati, S.; Raj, A.; Willcox, M. Repeatability of lipid layer thickness using LipiView® following removal of contact lenses and its relationship to comfort. Ophthalmic Physiol. Opt. 2025, 45, 383–390. [Google Scholar] [CrossRef]
- Valencia-Nieto, L.; la Rosa, A.L.-D.; López-Miguel, A.; González-García, M.J. The relationship between the eyelid status and contact lens discomfort. Contact Lens Anterior Eye 2025, 48, 102439. [Google Scholar] [CrossRef]
- Valencia-Nieto, L.; la Rosa, A.L.-D.; López-Miguel, A.; González-García, M.J. Clinical characterisation of contact lens discomfort progression. Contact Lens Anterior Eye 2024, 47, 102096. [Google Scholar] [CrossRef]
- Novo-Diez, A.; Valencia-Nieto, L.; Pérez-Charro, S.; la Rosa, A.L.-D.; López-Miguel, A.; González-García, M.J. Characterization of the Pre-lens Tear Film in Hydrogel and Silicone Hydrogel Contact Lens Wear. J. Ophthalmic Vis. Res. 2025, 20, 1–7. [Google Scholar] [CrossRef]
- Kim, Y.H.; Graham, A.D.; Li, W.; Dursch, T.J.; Peng, C.C.; Radke, C.J.; Lin, M.C. Tear-film evaporation flux and its relationship to tear properties in symptomatic and asymptomatic soft-contact-lens wearers. Contact Lens Anterior Eye 2023, 46, 101850. [Google Scholar] [CrossRef]
- Tichenor, A.A.; Cox, S.M.; Ziemanski, J.F.; Ngo, W.; Karpecki, P.M.; Nichols, K.K.; Nichols, J.J. Effect of the Bruder moist heat eye compress on contact lens discomfort in contact lens wearers: An open-label randomized clinical trial. Contact Lens Anterior Eye 2019, 42, 625–632. [Google Scholar] [CrossRef]
- Park, K.S.; Lee, B.J.; Ang, M.J.; Eslani, M.; Shacterman, S.; Jun, J.; Gomez, M.L.; Kikkawa, D.O.; Afshari, N.A. Investigating Mask-Associated Dry Eye and Contributing Factors in Healthcare Providers. Clin. Ophthalmol. 2025, 19, 1443–1454. [Google Scholar] [CrossRef]
- Dutta, D.; Kim, J.; Sarkes, M.; Nath, S.; Markoulli, M. The repeatability of subjective and objective tear ferning assessment and its association with lipid layer thickness, non-invasive tear break-up time and comfort. Contact Lens Anterior Eye 2019, 42, 420–427. [Google Scholar] [CrossRef]
- Yokoi, N.; Eftimov, P.; Georgiev, G.A.; Yokoi, N.; Eftimov, P.; Georgiev, G.A. Dynamic Aspects of Pre-Soft Contact Lens Tear Film and Their Relation to Dry Eye: Basic Science and Clinical Relevance. Life 2023, 13, 859. [Google Scholar] [CrossRef]
- Mann, A.M.; Wolffsohn, J.S.; Young, G.; Tighe, B.J. The contact lens-tear film interface: Investigating the tear envelope. Contact Lens Anterior Eye 2025, 48, 102319. [Google Scholar] [CrossRef]
- Ramasubramanian, D.; Hernández-Verdejo, J.L.; López-Alonso, J.M. Influence of Contact Lens Parameters on Tear Film Dynamics. Bull. Math. Biol. 2025, 87, 45. [Google Scholar] [CrossRef]
- Rueff, E.M.; Tichenor, A.A.; Ngo, W.; Pucker, A.D. A review of meibomian gland structure, function, and contact lens wear. Contact Lens Anterior Eye 2022, 45, 101560. [Google Scholar] [CrossRef]
- Acera, A.; Ibarrondo, O.; Mateo-Orobia, A.J.; Pereiro, X.; Abad-García, B.; López-Plandolit, S.; Ruzafa, N.; Romero, M.; Blasco-Martínez, A.; Rodríguez, F.D.; et al. Identification of tear lipid biomarkers in women with dry eye disease and the impact of intense pulsed light therapy: A case-control study. BMC Ophthalmol. 2025, 25, 496. [Google Scholar] [CrossRef]







| Ref. # | Age Mean ± SD Range | Number of Subjects | Eye | CL Type | Duration of CL Wear | LLT Mean ± SD [nm] | Study Design | Device |
|---|---|---|---|---|---|---|---|---|
| Kumar et al., 2025 [28] | 25.4 ± 6.1 16 F 4 M | 20 | random | Clariti 1 day (CooperVision) somofilcon A Precision 1 (Alcon) verofilcon | experienced CL users +30 days in the study (min. 5 d/week 6 h/day) | baseline: 54.7 ± 14.7 95% CI: 50.1–59.2 somofilcon: 53.3 ± 15.9 95% CI: 45.1–61.5 verofilcon: 52.7 ± 14.5 95% CI: 45.3–60.3 | Prospective | LipiView II |
| Valencia-Nieto et al., 2025 [29] | 33.1 ± 11.9 87 F 50 M | 137 | random | soft CLs | min. 1 year | 75.2 ± 15.8 min-max: 36.0–100.0 | cross-sectional, observational study | LipiView II |
| Kim et al., 2023 [32] | SYM 23.5 ± 3.8 ASYM 22.7 ± 3.8 range 18–34 36 F 6 M * | 42 (21 SYM, 21 ASYM) | right | soft CLs comfilcon A (CooperVision) | SYM: 8.2 ± 3.9 yrs ASYM: 7.7 ± 3.9 yrs | SYM (visits 2–3, no-lens) 58.02 ± 16.53 ASYM (visits 2–3, no-lens) 57.76 ± 15.3 SYM (visits 4–5, no-lens) 74.95 ± 15.10 ASYM (visits 4–5, no-lens) 70.12 ± 15.17 | LipiView | |
| Valencia-Nieto et al., 2024 [30] | 34.4 ± 12.6 97/92 F † 53/50 M | 150/142 | random | soft CLs | days/weeks: 5.2 ± 2.1 hours/day: 9.0 ± 3.7 | Step 0: 75.8 ± 14.5 Step 1: 73.2 ± 16.3 Step 2: 72.5 ± 18.5 | prospective, cross-sectional study | LipiView II |
| Tichenor et al., 2019 [33] | Group 1: 32 ± 8 16 F 1 M Group 2: 32 ± 12 17 F Group 3: 36 ± 11 17 F | 51 | right | soft CLs | Group 1: 16.0 ± 6.9 yrs Group 2: 14.5 ± 7.9 yrs Group 3: 13.6 ± 8.8 yrs | Group 1: 57.1 ± 19.2 Group 2: 57.9 ± 21.4 Group 3: 60.3 ± 23.9 | single-center, randomized, open-label, unmasked clinical trial | LipiView II |
| Novo-Diez et al., 2025 [31] | 23.3 ± 3.9 18 F 6 M | 24 | random | omafilcon A (hydrogel) stenofilcon A Si-Hy (CooperVision) | 8.5 ± 5.3 yrs 5.4 ± 1.9 days/week 8.5 ± 3.1 h/day | baseline: 75.9 ± 14.2 hydrogel: 64.9 ± 15.5 Si-Hy: 75.8 ± 14.0 | randomized crossover, double-masked study | LipiView II |
| Variable | Measurement/Category | Observed Effect on LLT | Interpretation |
|---|---|---|---|
| Lens wear | Presence vs. absence of contact lenses | Mean LLT slightly higher with lenses but CI overlap indicates no consistent effect | Lens presence alone does not reliably alter LLT, mechanical/lipid interactions may be subtle |
| Lens material and surface | Soft CLs, silicone hydrogel, surface coatings, water-gradient technology | Advanced surface treatments may improve lipid spreading, not necessarily mean LLT | Influences tear film uniformity, interblink stability, and comfort |
| Duration of wear | Hours/day (≥6 h), days/week (≥5) | No consistent correlation detected, small sample sizes limit conclusions | Longer wear may affect lipid deposition, but data insufficient |
| Symptom status | Symptomatic vs. asymptomatic CL wearers | Symptomatic wearers tended to have lower LLT | Supports relationship between reduced LLT and CL discomfort/tear instability |
| Age | Mean 24–34 years | No trend detected | Narrow age range, unable to assess age-related differences |
| Sex | Female vs. male | Not consistently reported | Possible influence via meibomian gland function, insufficient data |
| Measurement protocol | Eye selection (right eye/random), device (LipiView, LipiView II), baseline vs. follow-up | Small variations across studies, pooled sensitivity analysis showed stable mean LLT | Differences in protocols introduce heterogeneity but do not materially affect pooled estimates |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Sobol, M.; Pniewski, J. Lipid Layer Thickness in Soft Contact Lens Wearers With and Without Lenses In Situ—A Systematic Review and Meta-Analysis. J. Clin. Med. 2026, 15, 1110. https://doi.org/10.3390/jcm15031110
Sobol M, Pniewski J. Lipid Layer Thickness in Soft Contact Lens Wearers With and Without Lenses In Situ—A Systematic Review and Meta-Analysis. Journal of Clinical Medicine. 2026; 15(3):1110. https://doi.org/10.3390/jcm15031110
Chicago/Turabian StyleSobol, Maria, and Jacek Pniewski. 2026. "Lipid Layer Thickness in Soft Contact Lens Wearers With and Without Lenses In Situ—A Systematic Review and Meta-Analysis" Journal of Clinical Medicine 15, no. 3: 1110. https://doi.org/10.3390/jcm15031110
APA StyleSobol, M., & Pniewski, J. (2026). Lipid Layer Thickness in Soft Contact Lens Wearers With and Without Lenses In Situ—A Systematic Review and Meta-Analysis. Journal of Clinical Medicine, 15(3), 1110. https://doi.org/10.3390/jcm15031110

