Pattern-Matched Powered Gait Orthosis Training in Patients with Neurological Gait Impairment: A Multicenter Prospective Pilot Study of Hip and Knee–Ankle–Foot Orthoses
Abstract
1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Participants
2.3. Devices
2.3.1. Hip Orthosis (HO)
2.3.2. Knee–Ankle–Foot Orthosis (KAFO)
2.4. Intervention
2.5. Outcome Measures
2.5.1. Primary Outcomes: Walking Performance
2.5.2. Secondary Outcomes: Balance and Functional Mobility
2.6. Statistical Analysis
3. Results
3.1. Participant Characteristics
3.2. Primary Outcomes: Changes in Walking Performance
3.2.1. KAFO Group
3.2.2. HO Group
3.3. Comparison of Without-Device and With-Device Conditions
3.4. Secondary Outcomes: Changes in Balance and Functional Mobility
3.5. Safety and Adverse Events
4. Discussion
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Feigin, V.L.; Forouzanfar, M.H.; Krishnamurthi, R.; Mensah, G.A.; Connor, M.; Bennett, D.A.; Moran, A.E.; Sacco, R.L.; Anderson, L.; Truelsen, T.; et al. Global and regional burden of stroke during 1990–2010: Findings from the Global Burden of Disease Study 2010. Lancet 2014, 383, 245–254. [Google Scholar] [CrossRef]
- Dobkin, B.H. Rehabilitation after stroke. N. Engl. J. Med. 2005, 352, 1677–1684. [Google Scholar] [CrossRef] [PubMed]
- Kwakkel, G.; Wagenaar, R.C.; Kollen, B.J.; Lankhorst, G.J. Predicting disability in stroke: A critical review of the literature. Age Ageing 1996, 25, 479–489. [Google Scholar] [CrossRef]
- Belda-Lois, J.M.; Horno, S.M.-D.; Bermejo-Bosch, I.; Moreno, J.C.; Pons, J.L.; Farina, D.; Iosa, M.; Molinari, M.; Tamburella, F.; Ramos-Murguialday, A.; et al. Rehabilitation of gait after stroke: A review towards a top-down approach. J. Neuroeng. Rehabil. 2011, 8, 66. [Google Scholar] [CrossRef]
- Hidler, J.; Nichols, D.; Pelliccio, M.; Brady, K. Advances in the understanding and treatment of stroke impairment using robotic devices. Top. Stroke Rehabil. 2005, 12, 22–35. [Google Scholar] [CrossRef]
- Krebs, H.I.; Hogan, N. Robotic therapy: The tipping point. Am. J. Phys. Med. Rehabil. 2012, 91, S290–S297. [Google Scholar] [CrossRef] [PubMed][Green Version]
- Mehrholz, J.; Thomas, S.; Kugler, J.; Pohl, M.; Elsner, B. Electromechanical-assisted training for walking after stroke. Cochrane Database Syst. Rev. 2020, 10, CD006185. [Google Scholar] [CrossRef] [PubMed]
- Leow, X.R.G.; Ng, S.L.A.; Lau, Y. Overground robotic exoskeleton training for patients with stroke on walking-related outcomes: A systematic review and meta-analysis of randomized controlled trials. Arch. Phys. Med. Rehabil. 2023, 104, 1698–1710. [Google Scholar] [CrossRef]
- Rodríguez-Fernández, A.; Lobo-Prat, J.; Font-Llagunes, J.M. Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments. J. Neuroeng. Rehabil. 2021, 18, 22. [Google Scholar] [CrossRef]
- Schwartz, I.; Meiner, Z. Robotic-assisted gait training in neurological patients: Who may benefit the most? Ann. Biomed. Eng. 2015, 43, 1260–1269. [Google Scholar] [CrossRef]
- Louie, D.R.; Eng, J.J. Powered robotic exoskeletons in post-stroke rehabilitation of gait: A scoping review. J. Neuroeng. Rehabil. 2016, 13, 53. [Google Scholar] [CrossRef]
- Lajeunesse, V.; Vincent, C.; Routhier, F.; Careau, E.; Michaud, F. Exoskeletons’ design and usefulness evidence according to a systematic review of lower limb exoskeletons used for functional mobility by people with spinal cord injury. Disabil. Rehabil. Assist. Technol. 2016, 11, 535–547. [Google Scholar] [CrossRef]
- Cumplido-Trasmonte, C.; Molina-Rueda, F.; Puyuelo-Quintana, G.; Plaza-Flores, A.; Hernández-Melero, M.; Barquín-Santos, E.; Destarac-Eguizabal, M.A.; García-Armada, E. Satisfaction analysis of overground gait exoskeletons in people with neurological pathology. A systematic review. J. Neuroeng. Rehabil. 2023, 20, 47. [Google Scholar] [CrossRef]
- Young, A.J.; Ferris, D.P. State of the art and future directions for lower limb robotic exoskeletons. IEEE Trans. Neural Syst. Rehabil. Eng. 2017, 25, 171–182. [Google Scholar] [CrossRef]
- Contreras-Vidal, J.L.; Bhagat, N.A.; Brantley, J.; Cruz-Garza, J.G.; He, Y.; Manley, Q.; Nakagome, S.; Nathan, K.; Tan, S.H.; Zhu, F.; et al. Powered exoskeletons for bipedal locomotion after spinal cord injury. J. Neural Eng. 2016, 13, 031001. [Google Scholar] [CrossRef] [PubMed]
- Awad, L.N.; Bae, J.; O’donnell, K.; De Rossi, S.M.M.; Hendron, K.; Sloot, L.H.; Kudzia, P.; Allen, S.; Holt, K.G.; Ellis, T.D.; et al. A soft robotic exosuit improves walking in patients after stroke. Sci. Transl. Med. 2017, 9, eaai9084. [Google Scholar] [CrossRef]
- Lee, H.J.; Lee, S.H.; Seo, K.; Lee, M.; Chang, W.H.; Choi, B.O.; Ryu, G.H.; Kim, Y.H. Training for walking efficiency with a wearable hip-assist robot in patients with stroke: A pilot randomized controlled trial. Stroke 2019, 50, 3545–3552. [Google Scholar] [CrossRef] [PubMed]
- Morone, G.; Bragoni, M.; Iosa, M.; De Angelis, D.; Venturiero, V.; Coiro, P.; Pratesi, L.; Paolucci, S. Who may benefit from robotic-assisted gait training? A randomized clinical trial in patients with subacute stroke. Neurorehabil. Neural Repair 2011, 25, 636–644. [Google Scholar] [CrossRef]
- Buesing, C.; Fisch, G.; O’Donnell, M.; Shahidi, I.; Thomas, L.; Mummidisetty, C.K.; Williams, K.J.; Takahashi, H.; Rymer, W.Z.; Jayaraman, A. Effects of a wearable exoskeleton stride management assist system (SMA) on spatiotemporal gait characteristics in individuals after stroke: A randomized controlled trial. J. Neuroeng. Rehabil. 2015, 12, 69. [Google Scholar] [CrossRef] [PubMed]
- Ganguly, K.; Byl, N.N.; Abrams, G.M. Neurorehabilitation: Motor recovery after stroke as an example. Ann. Neurol. 2013, 74, 373–381. [Google Scholar] [CrossRef]
- Ting, L.H.; Chiel, H.J.; Trumbower, R.D.; Allen, J.L.; McKay, J.L.; Hackney, M.E.; Kesar, T.M. Neuromechanical principles underlying movement modularity and their implications for rehabilitation. Neuron 2015, 86, 38–54. [Google Scholar] [CrossRef]
- Yun, Y.J.; Kim, B.K.; Cho, H.; Choi, H.J.; Shin, D.; Jang, H.; Kim, M.J. Clinical usability and functional outcomes of a lightweight robotic orthosis (HKAFO) in chronic stroke patients with hemiplegic gait: A pilot study. J. Neuroeng. Rehabil. 2025, 22, 249. [Google Scholar] [CrossRef]
- ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. ATS statement: Guidelines for the six-minute walk test. Am. J. Respir. Crit. Care Med. 2002, 166, 111–117. [Google Scholar] [CrossRef]
- Bohannon, R.W. Comfortable and maximum walking speed of adults aged 20–79 years: Reference values and determinants. Age Ageing 1997, 26, 15–19. [Google Scholar] [CrossRef]
- Berg, K.O.; Wood-Dauphinee, S.L.; Williams, J.I.; Maki, B. Measuring balance in the elderly: Validation of an instrument. Can. J. Public Health 1992, 83, S7–S11. [Google Scholar] [PubMed]
- Blum, L.; Korner-Bitensky, N. Usefulness of the Berg Balance Scale in stroke rehabilitation: A systematic review. Phys. Ther. 2008, 88, 559–566. [Google Scholar] [CrossRef] [PubMed]
- Podsiadlo, D.; Richardson, S. The timed ‘Up & Go’: A test of basic functional mobility for frail elderly persons. J. Am. Geriatr. Soc. 1991, 39, 142–148. [Google Scholar] [CrossRef]
- Ng, S.S.; Hui-Chan, C.W. The Timed Up & Go Test: Its reliability and association with lower-limb impairments and locomotor capacities in people with chronic stroke. Arch. Phys. Med. Rehabil. 2005, 86, 1641–1647. [Google Scholar] [CrossRef]
- Jonsdottir, J.; Cattaneo, D. Reliability and validity of the Dynamic Gait Index in persons with chronic stroke. Arch. Phys. Med. Rehabil. 2007, 88, 1410–1415. [Google Scholar] [CrossRef]
- Hsu, T.H.; Tsai, C.L.; Chi, J.Y.; Hsu, C.Y.; Lin, Y.N. Effect of wearable exoskeleton on post-stroke gait: A systematic review and meta-analysis. Ann. Phys. Rehabil. Med. 2023, 66, 101674. [Google Scholar] [CrossRef] [PubMed]
- Perera, S.; Mody, S.H.; Woodman, R.C.; Studenski, S.A. Meaningful change and responsiveness in common physical performance measures in older adults. J. Am. Geriatr. Soc. 2006, 54, 743–749. [Google Scholar] [CrossRef] [PubMed]
- Romero, S.; Bishop, M.D.; Velozo, C.A.; Light, K. Minimum detectable change of the Berg Balance Scale and Dynamic Gait Index in older persons at risk for falling. J. Geriatr. Phys. Ther. 2011, 34, 131–137. [Google Scholar] [CrossRef]
- Molteni, F.; Guanziroli, E.; Goffredo, M.; Calabrò, R.S.; Pournajaf, S.; Gaffuri, M.; Gasperini, G.; Filoni, S.; Baratta, S.; Galafate, D.; et al. Gait recovery with an overground powered exoskeleton: A randomized controlled trial on subacute stroke subjects. Brain Sci. 2021, 11, 104. [Google Scholar] [CrossRef] [PubMed]
- Chang, W.H.; Kim, T.-W.; Kim, H.S.; Hanapiah, F.A.; Lee, J.W.; Han, S.-H.; Jia, C.W.; Kim, D.H.; Kim, D.Y. Efficacy of wearable exoskeleton for gait recovery in patients with stroke: A multicenter randomized controlled trial. Stroke 2026, 57, 577–586. [Google Scholar] [CrossRef]
- Murayama, M. Effectiveness of a knee-ankle-foot orthosis with a knee extension aid in gait training for stroke patients. Jpn. J. Compr. Rehabil. Sci. 2021, 12, 32–37. [Google Scholar] [CrossRef] [PubMed]
- Hornby, T.G.; Reisman, D.S.; Ward, I.G.; Scheets, P.L.; Miller, A.; Haddad, D.; Fox, E.J.; Fritz, N.E.; Hawkins, K.; Henderson, C.E.; et al. Clinical Practice Guideline to Improve Locomotor Function Following Chronic Stroke, Incomplete Spinal Cord Injury, and Brain Injury. J. Neurol. Phys. Ther. 2020, 44, 49–100. [Google Scholar] [CrossRef]
- Metani, A.; Popović-Maneski, L.; Seguin, P.; Di Marco, J. NeuroSkin®: AI-driven wearable functional electrical stimulation for post-stroke gait recovery—A multicenter feasibility study. Sensors 2025, 25, 5614. [Google Scholar] [CrossRef]
- Babić, N.; Fernandes De Sousa, B.; Levy, J.; Touzard, F.; Blancho, S.; Séguin, P.; Metani, A.; Descollonges, M. Feasibility of AI-driven multichannel FES-assisted gait and cycling training in chronic neurological disorders: A case series. J. Neuroeng. Rehabil. 2026, 23, 144. [Google Scholar] [CrossRef]


| Variable | HO (n = 39) | KAFO (n = 36) |
|---|---|---|
| Age, years | 65.4 ± 9.2 | 60.3 ± 12.3 |
| Sex, male/female | 19/20 | 29/7 |
| BMI, kg/m2 | 24.7 ± 3.2 | 25.4 ± 3.4 |
| FAC score | 3.0 [2–4] | 2.5 [2–4] |
| Diagnosis, n (%) | ||
| Stroke | 22 (56.4) | 32 (88.9) |
| Traumatic brain injury | 2 (5.1) | 1 (2.8) |
| Other neurological (e.g., cerebral palsy, spinal cord injury, Parkinson’s disease) | 15 (38.5) | 3 (8.3) |
| Baseline outcomes, median [IQR] | ||
| BBS, score | 50.0 [41.0–53.0] | 43.5 [36.0–47.8] |
| TUG, s | 12.6 [10.0–18.5] | 17.9 [14.3–27.8] |
| DGI, score | 19.0 [12.0–23.0] | 16.0 [13.3–21.8] |
| 6MWT (WO), m | 300.0 [242.9–413.6] | 205.5 [142.5–274.5] |
| 10MWT speed (WO), m/s | 1.25 [0.79–1.51] | 0.67 [0.49–0.84] |
| MMT, median [IQR] | ||
| Hip flexion | 4 [3–4] | 4 [3–4.33] |
| Hip extension | 3.33 [3–4] | 3.33 [3–4] |
| Knee flexion | 3.33 [3–4] | 3.67 [3–4.33] |
| Knee extension | 4 [4–5] | 4 [3.33–5] |
| Ankle dorsiflexion | 4 [2–4.83] | 4 [3–4.33] |
| Ankle plantarflexion | 4 [2.08–4.83] | 4 [3–4.33] |
| Outcome | Condition | n | Pre-Training Median [IQR] | Post-Training Median [IQR] | p-Value | r |
|---|---|---|---|---|---|---|
| KAFO group | ||||||
| 6MWT (m) | WO | 31 | 205.5 [142.5–274.5] | 227.7 [168.4–323.6] | <0.001 | 0.668 |
| WITH | 31 | 237.1 [191.1–280.7] | 233.0 [160.6–308.6] | 0.001 | 0.601 | |
| 10MWT speed (m/s) | WO | 31 | 0.67 [0.49–0.84] | 0.76 [0.51–1.05] | 0.007 | 0.483 |
| WITH | 31 | 0.63 [0.40–0.74] | 0.72 [0.51–0.91] | <0.001 | 0.806 | |
| 10MWT time (s) | WO | 31 | 7.44 [5.93–10.27] | 6.57 [4.76–9.73] | 0.035 | 0.378 |
| WITH | 31 | 7.88 [6.74–12.35] | 6.95 [5.46–9.75] | <0.001 | 0.676 | |
| HO group | ||||||
| 6MWT (m) | WO | 39 | 300.0 [242.9–413.6] | 331.5 [269.5–422.7] | 0.001 | 0.511 |
| WITH | 39 | 275.0 [198.6–333.8] | 304.2 [245.1–362.4] | <0.001 | 0.679 | |
| 10MWT speed (m/s) | WO | 39 | 1.25 [0.79–1.51] | 1.36 [0.96–1.60] | <0.001 | 0.559 |
| WITH | 39 | 1.00 [0.70–1.24] | 1.19 [0.98–1.41] | <0.001 | 0.835 | |
| 10MWT time (s) | WO | 39 | 4.01 [3.32–6.31] | 3.68 [3.13–5.19] | <0.001 | 0.619 |
| WITH | 39 | 4.97 [4.05–7.09] | 4.20 [3.55–5.10] | <0.001 | 0.836 | |
| Outcome | n | Without Device (WO) Median [IQR] | With Device (WITH) Median [IQR] | p-Value |
|---|---|---|---|---|
| KAFO group—Baseline | ||||
| 6MWT (m) | 31 | 205.5 [142.5–274.5] | 237.1 [191.1–280.7] | 0.003 |
| 10MWT speed (m/s) | 31 | 0.67 [0.49–0.84] | 0.63 [0.40–0.74] | <0.001 |
| 10MWT time (s) | 31 | 7.44 [5.93–10.27] | 7.88 [6.74–12.35] | <0.001 |
| KAFO group—Post-training | ||||
| 6MWT (m) | 31 | 227.7 [168.4–323.6] | 233.0 [160.6–308.6] | 0.022 |
| 10MWT speed (m/s) | 31 | 0.76 [0.51–1.05] | 0.72 [0.51–0.91] | 0.011 |
| 10MWT time (s) | 31 | 6.57 [4.76–9.73] | 6.95 [5.46–9.75] | 0.116 |
| HO group—Baseline | ||||
| 6MWT (m) | 39 | 300.0 [242.9–413.6] | 275.0 [198.6–333.8] | <0.001 |
| 10MWT speed (m/s) | 39 | 1.25 [0.79–1.51] | 1.00 [0.70–1.24] | <0.001 |
| 10MWT time (s) | 39 | 4.01 [3.32–6.31] | 4.97 [4.05–7.09] | <0.001 |
| HO group—Post-training | ||||
| 6MWT (m) | 39 | 331.5 [269.5–422.7] | 304.2 [245.1–362.4] | <0.001 |
| 10MWT speed (m/s) | 39 | 1.36 [0.96–1.60] | 1.19 [0.98–1.41] | <0.001 |
| 10MWT time (s) | 39 | 3.68 [3.13–5.19] | 4.20 [3.55–5.10] | 0.002 |
| Outcome | n | Pre-Training Median [IQR] | Post-Training Median [IQR] | Δ Median | p-Value | r |
|---|---|---|---|---|---|---|
| KAFO group | ||||||
| BBS (score) | 31 | 43.5 [36.0–47.8] | 49.0 [46.0–53.0] | +5.5 | 0.0005 | 0.625 |
| TUG (s) | 31 | 17.9 [14.3–27.8] | 12.8 [9.7–14.5] | −5.1 | <0.001 | 0.679 |
| DGI (score) | 31 | 16.0 [13.3–21.8] | 22.0 [16.0–23.0] | +6.0 | 0.002 | 0.567 |
| HO group | ||||||
| BBS (score) | 39 | 50.0 [41.0–53.0] | 51.0 [40.0–53.0] | +1.0 | <0.001 | 0.633 |
| TUG (s) | 39 | 12.6 [10.0–18.5] | 13.4 [8.8–15.7] | +0.8 | <0.001 | 0.685 |
| DGI (score) | 39 | 19.0 [12.0–23.0] | 17.0 [13.0–23.0] | −2.0 | <0.001 | 0.633 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Yun, Y.J.; Moon, C.; Kim, K.-H.; Kim, T.-H.; Kim, B.-K.; Choi, H.; Shin, D.; Jang, H.; Jang, S.H.; Kim, M.J. Pattern-Matched Powered Gait Orthosis Training in Patients with Neurological Gait Impairment: A Multicenter Prospective Pilot Study of Hip and Knee–Ankle–Foot Orthoses. J. Clin. Med. 2026, 15, 3580. https://doi.org/10.3390/jcm15103580
Yun YJ, Moon C, Kim K-H, Kim T-H, Kim B-K, Choi H, Shin D, Jang H, Jang SH, Kim MJ. Pattern-Matched Powered Gait Orthosis Training in Patients with Neurological Gait Impairment: A Multicenter Prospective Pilot Study of Hip and Knee–Ankle–Foot Orthoses. Journal of Clinical Medicine. 2026; 15(10):3580. https://doi.org/10.3390/jcm15103580
Chicago/Turabian StyleYun, Yeo Joon, Changwon Moon, Ki-Hoon Kim, Tae-Hoon Kim, Bo-Kyoung Kim, HyukJae Choi, Dongbin Shin, Hyeyoun Jang, Seong Ho Jang, and Mi Jung Kim. 2026. "Pattern-Matched Powered Gait Orthosis Training in Patients with Neurological Gait Impairment: A Multicenter Prospective Pilot Study of Hip and Knee–Ankle–Foot Orthoses" Journal of Clinical Medicine 15, no. 10: 3580. https://doi.org/10.3390/jcm15103580
APA StyleYun, Y. J., Moon, C., Kim, K.-H., Kim, T.-H., Kim, B.-K., Choi, H., Shin, D., Jang, H., Jang, S. H., & Kim, M. J. (2026). Pattern-Matched Powered Gait Orthosis Training in Patients with Neurological Gait Impairment: A Multicenter Prospective Pilot Study of Hip and Knee–Ankle–Foot Orthoses. Journal of Clinical Medicine, 15(10), 3580. https://doi.org/10.3390/jcm15103580