Coronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications
Abstract
1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Study Participants
2.3. Coronary CTA Acquisition, Reconstruction, and Measurements
2.4. Sampling Technique
2.5. Statistical Analysis
3. Results
4. Discussion
- (1)
- There was excellent overall concordance between calcium scores using the 4 reconstruction methods studied.
- (2)
- Calcium scores from VNC were lower than those from TNC.
- (3)
- Correct classification of calcium risk category for true non-contrast 3 × 1.5 mm was very high, and for virtual non-contrast cases was moderate to high.
- (4)
- Slice interval (overlap) did not appear to play a significant role in misclassification.
4.1. Formatting of Mathematical Components
4.2. Prior Studies on CAC Scoring Using Spectral CT and PCD-CT
4.3. Current Study
4.4. Limitations
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
Abbreviations
CACS | coronary artery calcium score |
CAD | coronary artery disease |
CT | computed tomography |
TNC | true non-contrast |
VNC | virtual non-contrast |
CTA | CT angiography |
References
- Langenbach, I.L.; Wienemann, H.; Klein, K.; Scholtz, J.E.; Pennig, L.; Langzam, E.; Pahn, G.; Holz, J.A.; Maintz, D.; Naehle, C.P.; et al. Coronary calcium scoring using virtual non-contrast reconstructions on a dual-layer spectral CT system: Feasibility in the clinical practice. Eur. J. Radiol. 2023, 159, 110681. [Google Scholar] [CrossRef]
- Gassert, F.G.; Schacky, C.E.; Müller-Leisse, C.; Gassert, F.T.; Pahn, G.; Laugwitz, K.-L.; Makowski, M.R.; Nadjiri, J. Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: Comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective. Eur. Radiol. 2021, 31, 6193–6199. [Google Scholar] [CrossRef] [PubMed]
- Agatston, A.S.; Janowitz, W.R.; Hildner, F.J.; Zusmer, N.R.; Viamonte, M.; Detrano, R. Quantification of coronary artery calcium using ultrafast computed tomography. J. Am. Coll. Cardiol. 1990, 15, 827–832. [Google Scholar] [CrossRef] [PubMed]
- Greenland, P.; Blaha, M.J.; Budoff, M.J.; Erbel, R.; Watson, K.E. Coronary Calcium Score and Cardiovascular Risk. J. Am. Coll. Cardiol. 2018, 72, 434–447. [Google Scholar] [CrossRef]
- Shreya, D.; Zamora, D.I.; Patel, G.S.; Grossmann, I.; Rodriguez, K.; Soni, M.; Joshi, P.K.; Patel, S.C.; Sange, I. Coronary Artery Calcium Score—A Reliable Indicator of Coronary Artery Disease? Cureus 2021, 13, e20149. [Google Scholar] [CrossRef] [PubMed]
- Kim, S.Y.; Suh, Y.J.; Lee, H.-J.; Kim, H.; Seo, H.; Park, H.J.; Yang, D.H. Influence of computed tomography slice thickness on deep learning-based, automatic coronary artery calcium scoring software performance. Quant. Imaging Med. Surg. 2023, 13, 4257–4267. [Google Scholar] [CrossRef]
- Flohr, T.; Schmidt, B.; Ulzheimer, S.; Alkadhi, H. Cardiac imaging with photon counting CT. Br. J. Radiol. 2023, 96, 20230407. [Google Scholar] [CrossRef]
- Cohen, J.F.; Korevaar, D.A.; Altman, D.G.; Bruns, D.E.; Gatsonis, C.A.; Hooft, L.; Irwig, L.; Levine, D.; Reitsma, J.B.; de Vet, H.C.; et al. STARD 2015 guidelines for reporting diagnostic accuracy studies: Explanation and elaboration. BMJ Open 2016, 6, e012799. [Google Scholar] [CrossRef]
- Hecht, H.S.; Cronin, P.; Blaha, M.J.; Budoff, M.J.; Kazerooni, E.A.; Narula, J.; Yankelevitz, D.; Abbara, S. 2016 SCCT/STR guidelines for coronary artery calcium scoring of noncontrast noncardiac chest CT scans: A report of the Society of Cardiovascular Computed Tomography and Society of Thoracic Radiology. J. Cardiovasc. Comput. Tomogr. 2017, 11, 74–84. [Google Scholar] [CrossRef]
- Blaha, M.J.; Mortensen, M.B.; Kianoush, S.; Tota-Maharaj, R.; Cainzos-Achirica, M. Coronary Artery Calcium Scoring: Is It Time for a Change in Methodology? JACC Cardiovasc. Imaging 2017, 10, 923–937. [Google Scholar] [CrossRef]
- Raunig, D.L.; McShane, L.M.; Pennello, G.; Gatsonis, C.; Carson, P.L.; Voyvodic, J.T.; Wahl, R.L.; Kurland, B.F.; Schwarz, A.J.; Gonen, M.; et al. Quantitative imaging biomarkers: A review of statistical methods for technical performance assessment. Stat. Methods Med. Res. 2015, 24, 27–67. [Google Scholar] [CrossRef]
- Rinehart, S.; Raible, S.J.; Ng, N.; Mullen, S.; Huey, W.; Rogers, C.; Pursnani, A. Utility of Artificial Intelligence Plaque Quantification: Results of the DECODE Study. J. Soc. Cardiovasc. Angiogr. Interv. 2024, 3, 101296. [Google Scholar] [CrossRef] [PubMed]
- Dunham, A. A Randomized Comparison of Stage-Based Care Versus Risk Factor-Based Care for Prevention of Cardiovascular Events (TRANSFORM). Identifier: NCT06112418. Available online: https://clinicaltrials.gov/study/NCT06112418 (accessed on 20 March 2025).
- Yang, P.; Zhao, R.; Deng, W.; An, S.; Li, Y.; Sheng, M.; Chen, X.; Qian, Y.; Yu, Y.; Mu, D.; et al. Feasibility and accuracy of coronary artery calcium score on virtual non-contrast images derived from a dual-layer spectral detector CT: A retrospective multicenter study. Front. Cardiovasc. Med. 2023, 10, 1114058. [Google Scholar] [CrossRef]
- Nadjiri, J.; Kaissis, G.; Meurer, F.; Weis, F.; Laugwitz, K.-L.; Straeter, A.S.; Muenzel, D.; Noël, P.B.; Rummeny, E.J.; Rasper, M. Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data. PLoS ONE 2018, 13, e0208588. [Google Scholar] [CrossRef] [PubMed]
- Song, I.; Yi, J.G.; Park, J.H.; Kim, S.M.; Lee, K.S.; Chung, M.J. Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring. Korean J. Radiol. 2016, 17, 321–329. [Google Scholar] [CrossRef] [PubMed]
- Symons, R.; Sandfort, V.; Mallek, M.; Ulzheimer, S.; Pourmorteza, A. Coronary artery calcium scoring with photon-counting CT: First in vivo human experience. Int. J. Cardiovasc. Imaging 2019, 35, 733–739. [Google Scholar] [CrossRef]
- Mergen, V.; Ghouse, S.; Sartoretti, T.; Manka, R.; Euler, A.; Kasel, A.M.; Alkadhi, H.; Eberhard, M. Cardiac Virtual Noncontrast Images for Calcium Quantification with Photon-counting Detector CT. Radiol. Cardiothorac. Imaging 2023, 5, e220307. [Google Scholar] [CrossRef]
- Braun, F.M.; Risch, F.; Decker, J.A.; Woźnicki, P.; Bette, S.; Becker, J.; Rippel, K.; Scheurig-Münkler, C.; Kröncke, T.J.; Schwarz, F. Image Characteristics of Virtual Non-Contrast Series Derived from Photon-Counting Detector Coronary CT Angiography-Prerequisites for and Feasibility of Calcium Quantification. Diagnostics 2023, 13, 3402. [Google Scholar] [CrossRef]
- Emrich, T.; Aquino, G.; Schoepf, U.J.; Braun, F.M.; Risch, F.; Bette, S.J.; Woznicki, P.; Decker, J.A.; O’Doherty, J.; Brandt, V.; et al. Coronary Computed Tomography Angiography-Based Calcium Scoring: In vitro and in vivo validation of a novel virtual noniodine reconstruction algorithm on a clinical, first-generation dual-source photon counting-detector system. Investig. Radiol. 2022, 57, 536–543. [Google Scholar] [CrossRef]
- Sharma, S.P.; van der Bie, J.; van Straten, M.; Hirsch, A.; Bos, D.; Dijkshoorn, M.L.; Booij, R.; Budde, R.P.J. Coronary calcium scoring on virtual non-contrast and virtual non-iodine reconstructions compared to true non-contrast images using photon-counting computed tomography. Eur. Radiol. 2024, 34, 3699–3707. [Google Scholar] [CrossRef]
- Gulati, M.; Levy, P.D.; Mukherjee, D.; Amsterdam, E.; Bhatt, D.L.; Birtcher, K.K.; Blankstein, R.; Boyd, J.; Bullock-Palmer, R.P.; Conejo, T.; et al. 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 2021, 144, e368–e454. [Google Scholar] [CrossRef] [PubMed]
- Reeves, R.A.; Halpern, E.J.; Rao, V.M. Cardiac Imaging Trends from 2010 to 2019 in the Medicare Population. Radiol. Cardiothorac. Imaging 2021, 3, e210156. [Google Scholar] [CrossRef] [PubMed]
- Goldfarb, J.W.; Weber, J. Trends in Cardiovascular MRI and CT in the U.S. Medicare Population from 2012 to 2017. Radiol. Cardiothorac. Imaging 2021, 3, e200112. [Google Scholar] [CrossRef] [PubMed]
- MedAxiom. 2023 Report: Cardiovascular Provider Compensation & Production Survey; MedAxiom: Orlando, FL, USA, 2023. [Google Scholar]
- Collet, C.; Sonck, J.; Leipsic, J.; Monizzi, G.; Buytaert, D.; Kitslaar, P.; Andreini, D.; De Bruyne, B. Implementing Coronary Computed Tomography Angiography in the Catheterization Laboratory. JACC Cardiovasc. Imaging 2021, 14, 1846–1855. [Google Scholar] [CrossRef]
- Sakai, K.; Shin, D.; Singh, M.; Malik, S.; Dakroub, A.; Sami, Z.; Weber, J.; Cao, J.J.; Parikh, R.; Chen, L.; et al. Diagnostic Performance and Clinical Impact of Photon-Counting Detector Computed Tomography in Coronary Artery Disease. J. Am. Coll. Cardiol. 2025, 85, 339–348. [Google Scholar] [CrossRef]
Reconstruction Comparison | Mean 1 | Mean 2 | Mean Diff | Inter-Class Correlation (95% Confidence Interval) |
---|---|---|---|---|
TNC 3 × 3 vs. TNC 3 × 1.5 mm | 300 ± 399 | 299 ± 392 | 0.8 ± 25 | 0.998 (0.997 to 0.999) |
TNC 3 × 3 vs. VNC 3 × 3 mm | 300 ± 399 | 276 ± 359 | 23.4 ± 95 | 0.967 (0.95 to 0.978) |
TNC 3 × 3 vs. VNC 3 × 1.5 mm | 300 ± 399 | 279 ± 362 | 20.3 ± 93 | 0.969 (0.953 to 0.979) |
Reconstruction Method | β0 * | SE of β0 | βreconstruction | SE of βreconstruction | βreconstruction p-Value | R2 |
---|---|---|---|---|---|---|
TNC 3 × 1.5 mm | −3.79369 | 3.54552 | 1.01497 | 0.00718 | <0.0001 | 0.996 |
VNC 3 × 3 mm | 0.08412 | 13.37829 | 1.08184 | 0.02945 | <0.0001 | 0.948 |
VNC 3 × 1.5 mm | −1.58745 | 13.15751 | 1.07538 | 0.02871 | <0.0001 | 0.950 |
Specificity | Sensitivity | |
---|---|---|
TNC 3 × 1.5 | ||
1 to 99 | 0.95 | 1 |
100 to 299 | 0.98 | 0.86 |
300+ | 0.98 | 0.96 |
VNC 3 × 3 | ||
1 to 99 | 0.88 | 0.87 |
100 to 299 | 0.91 | 0.67 |
300+ | 0.95 | 0.96 |
VNC 3 × 1.5 | ||
1 to 99 | 0.88 | 0.9 |
100 to 299 | 0.93 | 0.67 |
300+ | 0.95 | 0.96 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Kaldas, M.; Weber, J.; Parikh, R.; Pipitone, K.; Chau, K.; Shin, D.; Volleberg, R.; Ali, Z.; Khalique, O.K. Coronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications. J. Clin. Med. 2025, 14, 2875. https://doi.org/10.3390/jcm14092875
Kaldas M, Weber J, Parikh R, Pipitone K, Chau K, Shin D, Volleberg R, Ali Z, Khalique OK. Coronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications. Journal of Clinical Medicine. 2025; 14(9):2875. https://doi.org/10.3390/jcm14092875
Chicago/Turabian StyleKaldas, Marco, Jonathan Weber, Roosha Parikh, Karli Pipitone, Karen Chau, Doosup Shin, Rick Volleberg, Ziad Ali, and Omar K. Khalique. 2025. "Coronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications" Journal of Clinical Medicine 14, no. 9: 2875. https://doi.org/10.3390/jcm14092875
APA StyleKaldas, M., Weber, J., Parikh, R., Pipitone, K., Chau, K., Shin, D., Volleberg, R., Ali, Z., & Khalique, O. K. (2025). Coronary Calcium Scoring Using True and Virtual Non-Contrast Reconstructions on Photon-Counting CT with Differing Slice Increment: Impact on Calcium Severity Classifications. Journal of Clinical Medicine, 14(9), 2875. https://doi.org/10.3390/jcm14092875