Variability of Renal Ultrasound Measurements: How Physician Experience and Patient Position Affect Measurement Accuracy?
Abstract
1. Introduction
2. Materials and Methods
2.1. Participants
2.2. Ultrasound Equipment and Settings
2.3. Examiners and Measurement Protocol
2.4. Examination and Data Collection
2.5. Statistical Analysis
3. Results
3.1. Examiner Experience and Measurement Variability
3.2. Influence of Patient Positioning
4. Discussion
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Conflicts of Interest
Abbreviations
US | Ultrasonography |
ICC | Interclass Correlation Coefficient |
LD | Lateral decubitus |
YLL | Years of life lost |
CKD | Chronic kidney disease |
PAD | Percentage Absolute Difference |
References
- Hricak, H.; Lieto, R.P. Sonographic determination of renal volume. Radiology 1983, 148, 311–312. [Google Scholar] [CrossRef] [PubMed]
- Emamian, S.A.; Nielsen, M.B.; Pedersen, J.F.; Ytte, L. Kidney Dimensions at Sonography: Correlation with Age, Sex, and Habitus in 665 Adult Volunteers. J. Pak. Med. Assoc 2000, 50, 12–16. [Google Scholar] [CrossRef] [PubMed]
- Benjamin, A.; Chen, M.; Li, Q.; Chen, L.; Carrascal, C.A.; Xie, H.; Samir, A.E.; Anthony, B.W. Renal Volume Estimation Using Freehand Ultrasound Scans: An Ex Vivo Demonstration. Ultrasound Med. Biol. 2020, 46, 1769–1782. [Google Scholar] [CrossRef] [PubMed]
- Bakker, J.; Olree, M.; Kaatee, R.; de Lange, E.E.; Moons, K.G.; Beutler, J.J.; Beek, F.J. Renal Volume Measurements: Accuracy and Repeatability of US Compared with That of MR Imaging1. Radiol. Soc. N. Am. 1999, 211, 623–628. [Google Scholar] [CrossRef]
- Huang, Y.; Zheng, Y.; Zhang, C.; Zhong, S. Ultrasound Assessment of the Relevance of Liver, Spleen, and Kidney Dimensions with Body Parameters in Adolescents. Comput. Math. Methods Med. 2022, 2022, 9150803. [Google Scholar] [CrossRef]
- Egberongbe, A.A.; Adetiloye, V.A.; Adeyinka, A.O.; Afolabi, O.T.; Akintomide, A.O.; Ayoola, O.O. Evaluation of renal volume by ultrasonography in patients with essential hypertension in Ile-Ife, south western Nigeria. Libyan J. Med. 2010, 5, 1–7. [Google Scholar] [CrossRef]
- Braconnier, P.; Piskunowicz, M.; Vakilzadeh, N.; ME, M.; Zürcher, E.; Burnier, M.; Pruijm, M. How reliable is renal ultrasound to measure renal length and volume in patients with chronic kidney disease compared with magnetic resonance imaging? Acta Radiol. 2020, 61, 117–127. [Google Scholar] [CrossRef]
- Harhay, A.; Tummalapalli, S.; Ortiz, A.; Fogo, A.; Fliser, D.; Roy-Chaudhury, P.; Fontana, M.; Nangaku, M.; Wanner, C.; Malik, C.; et al. Chronic kidney disease and the global public health agenda: An international consensus. Nat. Rev. Nephrol. 2024, 20, 473–485. [Google Scholar] [CrossRef]
- Jha, V.; Al-Ghamdi, S.; Garcia Sanchez, J. Global economic burden associated with chronic kidney disease: A pragmatic review of medical costs for the Inside CKD research programme. Adv. Ther. 2023, 40, 4405. [Google Scholar] [CrossRef]
- Sanusi, A.A.; Arogundade, F.A.; Famurewa, O.C.; Akintomide, A.O.; Soyinka, F.O.; Ojo, O.E.; Akinsola, A. Relationship of ultrasonographically determined kidney volume with measured GFR, calculated creatinine clearance and other parameters in chronic kidney disease (CKD). Nephrol. Dial. Transplant. 2009, 24, 1690–1694. [Google Scholar] [CrossRef]
- Beland, M.D.; Walle, N.L.; Machan, J.T.; Cronan, J.J. Renal cortical thickness measured at ultrasound: Is it better than renal length as an indicator of renal function in chronic kidney disease? AJR Am. J. Roentgenol. 2010, 195, W146–W149. [Google Scholar] [CrossRef] [PubMed]
- Hoi, S.; Takata, T.; Sugihara, T.; Ida, A.; Ogawa, M.; Mae, Y.; Fukuda, S.; Munemura, C.; Isomoto, H. Predictive value of cortical thickness measured by ultrasonography for renal impairment: A longitudinal study in chronic kidney disease. J. Clin. Med. 2018, 7, 527. [Google Scholar] [CrossRef] [PubMed]
- Świętoń, D.; Bernard, W.; Grzywińska, M.; Czarniak, P.; Durawa, A.; Kaszubowski, M.; Piskunowicz, M.; Szurowska, E. A Comparability of Renal Length and Volume Measurements in MRI and Ultrasound in Children. Front. Pediatr. 2021, 9, 778079. [Google Scholar] [CrossRef] [PubMed]
- Larson, D.B.; Meyers, M.L.; O’Hara, S.M. Reliability of renal length measurements made with ultrasound compared with measurements from helical CT multiplanar reformat images. AJR Am. J. Roentgenol. 2011, 196, W592–W597. [Google Scholar] [CrossRef]
- Michel, S.C.; Forster, I.; Seifert, B.; Willi, U.V.; Huisman, T.A. Renal dimensions measured by ultrasonography in children: Variations as a function of the imaging plane and patient position. Eur. Radiol. 2004, 14, 1508–1512. [Google Scholar] [CrossRef]
- De Sanctis, J.T.; Connolly, S.A.; Bramson, R.T. Effect of patient position on sonographically measured renal length in neonates, infants, and children. AJR Am. J. Roentgenol. 1998, 170, 1381–1383. [Google Scholar] [CrossRef]
- Carrico, C.W.T.; Zerin, J.M. Sonographic measurement of renal length in children: Does the position of the patient matter? Pediatr. Radiol. 1996, 26, 553–555. [Google Scholar] [CrossRef]
- Tolsgaard, M.G.; Todsen, T.; Sorensen, J.L.; Ringsted, C.; Lorentzen, T.; Ottesen, B.; Tabor, A. International Multispecialty Consensus on How to Evaluate Ultrasound Competence: A Delphi Consensus Survey. PLoS ONE 2013, 8, e57687. [Google Scholar] [CrossRef]
- Ablett, M.J.; Coulthard, A.; Lee, R.E.; Richardson, D.L.; Bellas, T.; Owen, J.P.; Keir, M.J.; Butler, T.J. How reliable are ultrasound measurements of renal length in adults? Br. J. Radiol. Oxf. Acad. 1995, 68, 1087–1089. [Google Scholar] [CrossRef]
- Jang, Y.H.; Kang, M.H.; Kang, W.Y. Comparative Analysis of Maximum Renal Longitudinal Length with Positional Changes on Ultrasound with Multiplanar Reconstructed MR Image in Korean Adults. J. Korean Soc. Radiol. 2016, 75, 30–36. [Google Scholar] [CrossRef]
- Kouba, E.; Newman, B.; Dairiki Shortliffe, L.M. Analysis of Kidney Ultrasound Dimensions by Body Habitus and Position. J. Urol. 2016, 196, 943–949. [Google Scholar] [CrossRef]
Kidney | Descriptive Statistics | |||||||
---|---|---|---|---|---|---|---|---|
Measure | Side | Position | Examiner 1 | Examiner 2 | Examiner 3 | |||
Mean | SD | Mean | SD | Mean | SD | |||
Length | Right | Supine | 108.5 | 6.827 | 107.2 | 8.37 | 107.2 | 6.83 |
Prone | 109.3 | 6.104 | 108.2 | 6.54 | 105.6 | 7.21 | ||
Lateral decubitus | 110.4 | 6.431 | 108.9 | 8.54 | 106.9 | 9.70 | ||
Left | Supine | 109.2 | 5.930 | 109.1 | 8.45 | 107.1 | 8.39 | |
Prone | 109.7 | 7.358 | 108.2 | 8.87 | 106.7 | 8.82 | ||
Lateral decubitus | 110.6 | 6.199 | 109.3 | 9.59 | 106.4 | 7.56 | ||
Volume | Right | Supine | 128.8 | 34.048 | 125.5 | 30.20 | 130.1 | 33.44 |
Prone | 122.1 | 24.127 | 111.4 | 22.05 | 113.1 | 23.17 | ||
Lateral decubitus | 144.0 | 34.566 | 132.1 | 39.90 | 116.2 | 27.35 | ||
Left | Supine | 135.8 | 27.656 | 137.7 | 36.13 | 129.8 | 22.79 | |
Prone | 126.3 | 22.939 | 120.1 | 25.53 | 120.5 | 24.45 | ||
Lateral decubitus | 156.324 | 40.183 | 145.0 | 37.29 | 132.3 | 30.87 |
Kidney | Absolute Compatibility | Cohesion | ||||||
---|---|---|---|---|---|---|---|---|
Measure | Side | Position | ICC(2.3) | CI (95%) | p-Value | ICC(2.3) | CI (95%) | p-Value |
Length | Right | Supine | 0.67 | 0.45–0.80 | <0.001 | 0.66 | 0.45–0.80 | <0.001 |
Prone | 0.70 | 0.51–0.82 | <0.001 | 0.73 | 0.55–0.84 | <0.001 | ||
Lateral decubitus | 0.71 | 0.53–0.83 | <0.001 | 0.72 | 0.55–0.84 | <0.001 | ||
Left | Supine | 0.75 | 0.59–0.85 | <0.001 | 0.76 | 0.60–0.86 | <0.001 | |
Prone | 0.79 | 0.66–0.88 | <0.001 | 0.80 | 0.67–0.88 | <0.001 | ||
Lateral decubitus | 0.65 | 0.44–0.79 | <0.001 | 0.67 | 0.47–0.81 | <0.001 | ||
Volume | Right | Supine | 0.65 | 0.46–0.80 | <0.001 | 0.65 | 0.46–0.80 | <0.001 |
Prone | 0.66 | 0.50–0.82 | <0.001 | 0.68 | 0.53–0.83 | <0.001 | ||
Lateral decubitus | 0.60 | 0.32–0.75 | <0.001 | 0.65 | 0.38–0.77 | <0.001 | ||
Left | Supine | 0.71 | 0.23–0.72 | <0.001 | 0.71 | 0.24–0.72 | <0.001 | |
Prone | 0.75 | 0.66–0.87 | <0.001 | 0.76 | 0.66–0.88 | <0.001 | ||
Lateral decubitus | 0.66 | 0.40–0.78 | <0.001 | 0.70 | 0.47–0.81 | <0.001 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Świętoń, D.; Hryniewicz, G.; Grzywińska, M.; Kaszubowski, M.; Kosiak, W.; Czarniak, P.; Świętoń, J.; Storoniak, H.; Piskunowicz, M. Variability of Renal Ultrasound Measurements: How Physician Experience and Patient Position Affect Measurement Accuracy? J. Clin. Med. 2025, 14, 5840. https://doi.org/10.3390/jcm14165840
Świętoń D, Hryniewicz G, Grzywińska M, Kaszubowski M, Kosiak W, Czarniak P, Świętoń J, Storoniak H, Piskunowicz M. Variability of Renal Ultrasound Measurements: How Physician Experience and Patient Position Affect Measurement Accuracy? Journal of Clinical Medicine. 2025; 14(16):5840. https://doi.org/10.3390/jcm14165840
Chicago/Turabian StyleŚwiętoń, Dominik, Gabriela Hryniewicz, Małgorzata Grzywińska, Mariusz Kaszubowski, Wojciech Kosiak, Piotr Czarniak, Joanna Świętoń, Hanna Storoniak, and Maciej Piskunowicz. 2025. "Variability of Renal Ultrasound Measurements: How Physician Experience and Patient Position Affect Measurement Accuracy?" Journal of Clinical Medicine 14, no. 16: 5840. https://doi.org/10.3390/jcm14165840
APA StyleŚwiętoń, D., Hryniewicz, G., Grzywińska, M., Kaszubowski, M., Kosiak, W., Czarniak, P., Świętoń, J., Storoniak, H., & Piskunowicz, M. (2025). Variability of Renal Ultrasound Measurements: How Physician Experience and Patient Position Affect Measurement Accuracy? Journal of Clinical Medicine, 14(16), 5840. https://doi.org/10.3390/jcm14165840