Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis
Abstract
1. Introduction
2. Materials and Methods
2.1. Patient Assessment
2.2. Statistical Analysis
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
Abbreviations
FBUT | Fluorescein break-up time |
NIBUT | Non-invasive break-up time |
TBUT | Tear break-up time |
s | Seconds |
SD | Standard deviation |
IQR | Inter-quartile range |
DED | Dry eye disease |
AS-OCT | Anterior segment optical coherence tomographer |
Z | Wilcoxon signed-rank |
Z | Mann–Whitney U |
ρ | Spearman’s correlation coefficient |
References
- Vidal-Rohr, M.; Craig, J.P.; Davies, L.N.; Wolffsohn, J.S. The epidemiology of dry eye disease in the UK: The Aston dry eye study. Contact Lens Anterior Eye 2023, 46, 101837. [Google Scholar] [CrossRef] [PubMed]
- Wolffsohn, J.S.; Arita, R.; Chalmers, R.; Djalilian, A.; Dogru, M.; Dumbleton, K.; Gupta, P.K.; Karpecki, P.; Lazreg, S.; Pult, H.; et al. TFOS DEWS II Diagnostic Methodology report. Ocul. Surf. 2017, 15, 539–574. [Google Scholar] [CrossRef] [PubMed]
- Craig, J.P.; Nichols, K.K.; Akpek, E.K.; Caffery, B.; Dua, H.S.; Joo, C.-K.; Liu, Z.; Nelson, J.D.; Nichols, J.J.; Tsubota, K.; et al. TFOS DEWS II Definition and Classification Report. Ocul. Surf. 2017, 15, 276–283. [Google Scholar] [CrossRef] [PubMed]
- Paugh, J.R.; Tse, J.; Nguyen, T.; Sasai, A.; Chen, E.; De Jesus, M.T.; Kwan, J.; Nguyen, A.L.; Farid, M.; Garg, S.; et al. Efficacy of the Fluorescein Tear Breakup Time (TBUT) Test in Dry Eye. Cornea 2020, 39, 92. [Google Scholar] [CrossRef]
- Elliott, D.B. Clinical Procedures in Primary Eye Care, 4th ed.; Elsevier Health Sciences: Amsterdam, The Netherlands, 2013; Available online: https://ebookcentral.proquest.com/lib/coop/reader.action?c=RVBVQg&docID=1430753&ppg=331 (accessed on 24 July 2025).
- Norn, M.S. Desiccation of the precorneal film. Acta Ophthalmol. 1969, 47, 865–880. [Google Scholar] [CrossRef]
- Mooi, J.K.; Wang, M.T.M.; Lim, J.; Müller, A.; Craig, J.P. Minimising instilled volume reduces the impact of fluorescein on clinical measurements of tear film stability. Contact Lens Anterior Eye 2017, 40, 170–174. [Google Scholar] [CrossRef]
- Acet, Y.; Dağ, Y. Changes caused by fluorescein in the tear film evaluated with hybrid break-up time test as a new method—Part Two: Its effect on breakup locations and other quantitative values. Photodiagn. Photodyn. Ther. 2023, 43, 103651. [Google Scholar] [CrossRef]
- Mengher, L.S.; Bron, A.J.; Tonge, S.R.; Gilbert, D.J. Effect of fluorescein instillation on the pre-corneal tear film stability. Curr. Eye Res. 1985, 4, 9–12. [Google Scholar] [CrossRef]
- Lan, W.; Lin, L.; Yang, X.; Yu, M. Automatic noninvasive tear breakup time (TBUT) and conventional fluorescent TBUT. Optom. Vis. Sci. 2014, 91, 1412–1418. [Google Scholar] [CrossRef]
- Cho, P.; Douthwaite, W. The Relation between Invasive and Noninvasive Tear Break-Up Time. Optom. Vis. Sci. 1995, 72, 17–22. [Google Scholar] [CrossRef]
- Johnson, M.E.; Murphy, P.J. The effect of instilled fluorescein solution volume on the values and repeatability of TBUT measurements. Cornea 2005, 24, 811–817. [Google Scholar] [CrossRef]
- Lemp, M.A.; Hamill, J.R. Factors Affecting Tear Film Breakup in Normal Eyes. Arch. Ophthalmol. 1973, 89, 103–105. [Google Scholar] [CrossRef] [PubMed]
- Szczesna-Iskander, D.H.; Llorens-Quintana, C. Agreement between invasive and noninvasive measurement of tear film breakup time. Sci. Rep. 2024, 14, 3852. [Google Scholar] [CrossRef] [PubMed]
- Donaldson, K.; Fernández-Vega-Cueto, L.; Davidson, R.; Dhaliwal, D.; Hamilton, R.; Jackson, M.; Patterson, L.; Stonecipher, K.; ASCRS Refractive–Cataract Surgery Subcommittee. Perioperative assessment for refractive cataract surgery. J. Cataract Refract. Surg. 2018, 44, 642–653. [Google Scholar] [CrossRef] [PubMed]
- Karpecki, P.M.; Prokopich, C.L.; Racine, L.; Bitton, E.; Caffery, B.; Harasymowycz, P.; Michaud, L.; Pegado, V.D.; Dufour, J.-S.; Neumann, P.; et al. Dry Eye Diseases and Ocular Surgery: Practical Guidelines for Canadian Eye Care Practitioners. Can. J. Optom. 2017, 79, 19–33. [Google Scholar] [CrossRef]
- Starr, C.E.; Gupta, P.K.; Farid, M.; Beckman, K.A.; Chan, C.C.; Yeu, E.; Gomes, J.A.; Ayers, B.D.; Berdahl, J.P.; Holland, E.J.; et al. An algorithm for the preoperative diagnosis and treatment of ocular surface disorders. J. Cataract Refract. Surg. 2019, 45, 669–684. [Google Scholar] [CrossRef]
- Armstrong, R.A.; Eperjesi, F. Data Methods in Optometry Part 2 Is there a Difference Between Two Samples. Part 2 Optom. Today 2001, 2001, 27–31. [Google Scholar]
- Bland, J.M.; Altman, D.G. Measuring agreement in method comparison studies. Stat. Methods Med. Res. 1999, 8, 135–160. [Google Scholar] [CrossRef]
- Giavarina, D. Understanding Bland Altman analysis. Biochem. Med. 2015, 25, 141–151. [Google Scholar] [CrossRef]
- Frey, M.E.; Petersen, H.C.; Gerke, O. Nonparametric Limits of Agreement for Small to Moderate Sample Sizes: A Simulation Study. Stats 2020, 3, 343–355. [Google Scholar] [CrossRef]
- McLintock, C.; Uprety, S.; McKelvie, J. Corneal astigmatism agreement between a swept-source ocular coherence tomography and Scheimpflug–Placido based optical biometers. Int. Ophthalmol. 2025, 45, 83. [Google Scholar] [CrossRef]
- Twomey, P.J. How to use difference plots in quantitative method comparison studies. Ann. Clin. Biochem. 2006, 43, 124–129. [Google Scholar] [CrossRef] [PubMed]
- Prajapati, B.; Dunne, M.; Armstrong, R. Sample size estimation and statistical power analyses. Optom. Today 2010, 16, 10–18. Available online: https://www.researchgate.net/publication/265399772_Sample_size_estimation_and_statistical_power_analyses (accessed on 24 July 2025).
- Nichols, J.J.; Nichols, K.K.; Puent, B.; Saracino, M.; Mitchell, G.L. Evaluation of Tear Film Interference Patterns and Measures of Tear Break-Up Time. Optom. Vis. Sci. 2002, 79, 363–369. [Google Scholar] [CrossRef]
- Riazi, A.; Firouzi, N.; Salehi, R. Evaluating the Performance of Anterior Segment Optical Coherence Tomography MS-39 in Evaluating Tear Film and Comparing the Results With Tear Break-up Time Results by Slit Lamp. Funct. Disabil. J. 2022, 5, 56. [Google Scholar] [CrossRef]
- Jiang, Y.; Ye, H.; Xu, J.; Lu, Y. Noninvasive Keratograph assessment of tear film break-up time and location in patients with age-related cataracts and dry eye syndrome. J. Int. Med. Res. 2014, 42, 494–502. [Google Scholar] [CrossRef] [PubMed]
- Amaechi, O.; Osunwoke, C. The relation between invasive and non-invasive tear break-up time in young adults. J. Niger. Optom. Assoc. 2004, 11, 29–32. Available online: https://www.ajol.info/index.php/jnoa/article/view/64443 (accessed on 6 February 2025). [CrossRef]
- Hong, J.; Sun, X.; Wei, A.; Cui, X.; Li, Y.; Qian, T.; Wang, W.; Xu, J. Assessment of tear film stability in dry eye with a newly developed keratograph. Cornea 2013, 32, 716–721. [Google Scholar] [CrossRef]
- Bhandari, V.; Reddy, J.K.; Relekar, K.; Ingawale, A.; Shah, N. Non-invasive assessment of tear film stability with a novel corneal topographer in Indian subjects. Int. Ophthalmol. 2016, 36, 781–790. [Google Scholar] [CrossRef]
- Hong, J.; Liu, Z.; Hua, J.; Wei, A.; Xue, F.; Yang, Y.; Sun, X.; Xu, J. Evaluation of age-related changes in noninvasive tear breakup time. Optom. Vis. Sci. 2014, 91, 150–155. [Google Scholar] [CrossRef]
- Itokawa, T.; Suzuki, T.; Koh, S.; Hori, Y. Evaluating the Differences between Fluorescein Tear Break-up Time and Noninvasive Measurement Techniques. Eye Contact Lens 2023, 49, 104–109. [Google Scholar] [CrossRef]
- Zeri, F.; Rizzo, G.C.; Ponzini, E.; Tavazzi, S. Comparing automated and manual assessments of tear break-up time using different non-invasive devices and a fluorescein procedure. Sci. Rep. 2024, 14, 2516. [Google Scholar] [CrossRef] [PubMed]
- Kim, J.; Kim, J.Y.; Seo, K.Y.; Kim Tim Chin, H.S.; Jung, J.W. Location and pattern of non-invasive keratographic tear film break-up according to dry eye disease subtypes. Acta Ophthalmol. 2019, 97, e1089–e1097. [Google Scholar] [CrossRef] [PubMed]
- Wang, M.T.M.; Craig, J.P. Comparative Evaluation of Clinical Methods of Tear Film Stability Assessment: A Randomized Crossover Trial. JAMA Ophthalmol. 2018, 136, 291–294. [Google Scholar] [CrossRef] [PubMed]
- Cox, S.M.; Nichols, K.K.; Nichols, J.J.; Nichols, J.; Vis, O.; Author, S. Agreement between Automated and Traditional Measures of Tear Film Breakup. Optom. Vis. Sci. 2015, 92, e257. [Google Scholar] [CrossRef]
- Van Santvliet, L.; Ludwig, A. Determinants of eye drop size. Surv. Ophthalmol. 2004, 49, 197–213. [Google Scholar] [CrossRef]
- Downie, L.E. Automated Tear Film Surface Quality Breakup Time as a Novel Clinical Marker for Tear Hyperosmolarity in Dry Eye Disease. Investig. Ophthalmol. Vis. Sci. 2015, 56, 7260–7268. [Google Scholar] [CrossRef]
- Gumus, K.; Crockett, C.H.; Rao, K.; Yeu, E.; Weikert, M.P.; Shirayama, M.; Hada, S.; Pflugfelder, S.C. Noninvasive Assessment of Tear Stability with the Tear Stability Analysis System in Tear Dysfunction Patients. Investig. Ophthalmol. Vis. Sci. 2011, 52, 456. [Google Scholar] [CrossRef]
- Lim, J.; Wang, M.T.M.; Craig, J.P. Evaluating the diagnostic ability of two automated non-invasive tear film stability measurement techniques. Contact Lens Anterior Eye 2021, 44, 101362. [Google Scholar] [CrossRef]
- Sullivan, B.D.; Crews, L.A.; Sönmez, B.; de la Paz, M.F.; Comert, E.; Charoenrook, V.; de Araujo, A.L.; Pepose, J.S.; Berg, M.S.; Kosheleff, V.P.; et al. Clinical utility of objective tests for dry eye disease: Variability over time and implications for clinical trials and disease management. Cornea 2012, 31, 1000–1008. [Google Scholar] [CrossRef]
- Abdelfattah, N.S.; Dastiridou, A.; Sadda, S.V.R.; Lee, O.L. Noninvasive imaging of tear film dynamics in eyes with ocular surface disease. Cornea 2015, 34, S48–S52. [Google Scholar] [CrossRef]
- Cho, P.; Brown, B.; Lau, C. Effect of Fluorescein on the Tear Stability of Hong Kong-Chinese. Optom. Vis. Sci. 1996, 73, 1–7. [Google Scholar] [CrossRef]
- Mostafa, Y.M.S.E.; Saif, M.Y.S.; Saeed, M.A.; ElSaadany, S.A.M. The Effect of Age and Gender on Tear Film Breakup Time. Egypt. J. Med. Res. 2021, 2, 137–148. [Google Scholar] [CrossRef]
- Guillon, M.; Maïssa, C. Tear film evaporation—Effect of age and gender. Cont. Lens Anterior Eye 2010, 33, 171–175. [Google Scholar] [CrossRef] [PubMed]
- Stapleton, F.; Alves, M.; Bunya, V.Y.; Jalbert, I.; Lekhanont, K.; Malet, F.; Na, K.-S.; Schaumberg, D.; Uchino, M.; Vehof, J.; et al. TFOS DEWS II Epidemiology Report. Ocul. Surf. 2017, 15, 334–365. [Google Scholar] [CrossRef] [PubMed]
- Singh, S.; Srivastav, S.; Mohamed, A.; Basu, S. Non-invasive Tear Film Assessment in Normal Population: Effect of Age, Sex, and Interparametric Relationship. Front. Med. 2022, 9, 894184. [Google Scholar] [CrossRef]
- Wang, M.T.; Muntz, A.; Lim, J.; Kim, J.S.; Lacerda, L.; Arora, A.; Craig, J.P. Ageing and the natural history of dry eye disease: A prospective registry-based cross-sectional study. Ocul. Surf. 2020, 18, 736–741. [Google Scholar] [CrossRef]
- Sullivan, D.A.; Rocha, E.M.; Aragona, P.; Clayton, J.A.; Ding, J.; Golebiowski, B.; Hampel, U.; McDermott, A.M.; Schaumberg, D.A.; Srinivasan, S.; et al. TFOS DEWS II Sex, Gender, and Hormones Report. Ocul. Surf. 2017, 15, 284–333. [Google Scholar] [CrossRef]
- Abelson, M.B.; Ousler, G.W.; Nally, L.A.; Welch, D.; Krenzer, K. Alternative Reference Values for Tear Film Break up Time in Normal and Dry Eye Populations. Adv. Exp. Med. Biol. 2002, 506, 1121–1125. [Google Scholar]
First NIBUT | FBUT | Average NIBUT | |
---|---|---|---|
Right | 12.5 s (7.0–18.0) | 7 s (5–8) | 14.0 s (6.9–18.0) |
Left | 14.2 s (9.4–18.0) | 6 s (5–8) | 14.6 s (10.1–18.0) |
Median Difference (NIBUT-FBUT) | Wilcoxon Signed-Rank (Z) Difference Versus Median | Spearman’s Correlation Coefficient (ρ) Difference Versus Median | Median (NIBUT and FBUT) | |
---|---|---|---|---|
Right First NIBUT | 6 s (1.5–11.0) | Z = −14.099 p < 0.001 | ρ = 0.821 | 9.4 s (6.1–13.5) |
p < 0.001 | ||||
Right Average NIBUT | 7 s (3.9–11.0) | Z = −13.235 p < 0.001 | ρ = 0.761 | 10.3 s (7.4–13.5) |
p < 0.001 | ||||
Left First NIBUT | 7 s (1.7–11.0) | Z = −13.678 p < 0.001 | ρ = 0.789 | 10 s (6.25–13.1) |
p < 0.001 | ||||
Left Average NIBUT | 8.1 s (4.4–11.0) | Z = −12.692 p < 0.001 | ρ = 0.713 | 10.5 s (7.8–13.4) |
p < 0.001 |
Age | Sex | |
---|---|---|
Right First NIBUT | ρ = −0.104 * N = 366 p = 0.046 | Z = −5.585 * |
N = 366 | ||
p < 0.001 | ||
r = −0.292 | ||
Right Average NIBUT | ρ = −0.068 N = 366 p = 0.197 | Z = −4.924 * |
N = 366 | ||
p < 0.001 | ||
r = −0.257 | ||
Left First NIBUT | ρ = −0.02 N = 367 p = 0.971 | Z = −5.759 * |
N = 363 | ||
p < 0.001 | ||
r = −0.302 | ||
Left Average NIBUT | ρ = 0.04 N = 367 p = 0.935 | Z = −4.750 * |
N = 363 | ||
p < 0.001 | ||
r = −0.249 | ||
Right FBUT | ρ = −0.219 * N = 356 p < 0.001 | Z = −6.633 * |
N = 349 | ||
p < 0.001 | ||
r = −0.355 | ||
Left FBUT | ρ = −0.257 * N = 358 p < 0.001 | Z = −6.968 * |
N = 351 | ||
p < 0.001 | ||
r = −0.372 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Cairns, R.; McNeely, R.N.; Dunne, M.C.M.; Gil-Cazorla, R.; Naroo, S.A.; Moore, J.E. Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis. J. Clin. Med. 2025, 14, 5794. https://doi.org/10.3390/jcm14165794
Cairns R, McNeely RN, Dunne MCM, Gil-Cazorla R, Naroo SA, Moore JE. Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis. Journal of Clinical Medicine. 2025; 14(16):5794. https://doi.org/10.3390/jcm14165794
Chicago/Turabian StyleCairns, Rebecca, Richard N. McNeely, Mark C. M. Dunne, Raquel Gil-Cazorla, Shehzad A. Naroo, and Jonathan E. Moore. 2025. "Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis" Journal of Clinical Medicine 14, no. 16: 5794. https://doi.org/10.3390/jcm14165794
APA StyleCairns, R., McNeely, R. N., Dunne, M. C. M., Gil-Cazorla, R., Naroo, S. A., & Moore, J. E. (2025). Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis. Journal of Clinical Medicine, 14(16), 5794. https://doi.org/10.3390/jcm14165794