Article

Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis

by
Rebecca Cairns
1,2,
Richard N. McNeely
1,
Mark C. M. Dunne
2,
Raquel Gil-Cazorla
2,*,
Shehzad A. Naroo
2 and
Jonathan E. Moore
1,2,3,4
1
Cathedral Eye Clinic, Belfast BT1 2LS, UK
2
Optometry & Vision Science Research Group (OVSRG), College of Health and Life Sciences, Aston University, Birmingham B4 7ET, UK
3
Biomedical Sciences Research Institute, University of Ulster, Coleraine BT52 1SA, UK
4
Clinical College of Ophthalmology, Tianjin Medical University, Tianjin 301700, China
*
Author to whom correspondence should be addressed.
J. Clin. Med. 2025, 14(16), 5794; https://doi.org/10.3390/jcm14165794
Submission received: 16 May 2025 / Revised: 25 July 2025 / Accepted: 7 August 2025 / Published: 15 August 2025

Abstract

Objectives: Fluorescein break-up time (FBUT) is commonly used to assess tear film stability. However, the instillation of fluorescein destabilises the tear film, impacting validity and clinical applicability, while the subjective nature and variation in volume and concentration reduces repeatability. Non-invasive break-up time (NIBUT) offers an alternative method with less potential bias. Normal tear break-up time is conventionally accepted as 10 seconds (s); however, FBUT is expected to be lower than NIBUT. This study was designed to compare FBUT and NIBUT values in a pre-operative refractive surgery population, where diagnosis of dry eye disease may alter the risk–benefits ratio and contraindicate surgical procedure(s). Improved understanding of the relationship between these two methods will aid appropriate pre-operative patient counselling and consent. Methods: Data from consecutive participants presenting to a private ophthalmology clinic, for initial refractive surgery pre-operative assessment, were analysed. NIBUT and FBUT were performed. Paired and unpaired comparisons were made using the Wilcoxon signed-rank and Mann–Whitney U tests, respectively, and relationships with demographics were explored using Spearman’s rank correlation coefficient. Results: Median and interquartile range (IQR) for the first NIBUT was 12.5 s (7.0–18.0 s) and 14.2 s (9.4–18.0 s) for the right and left eyes, respectively. Median and IQR for the average NIBUT was 14.0 s (6.9–18.0 s) and 14.6 s (10.1–18.0 s) for the right and left eyes, respectively. Median and IQR for FBUT was 7 s (5–8 s) and 6 s (5–8 s) for the right and left eyes, respectively. There was a statistically significant difference between NIBUT and FBUT (p < 0.001). Conclusions: The findings suggest that the commonly used diagnostic threshold of 10 s cannot be uniformly applied to both FBUT and NIBUT, as FBUT systematically underestimates tear stability.
Keywords: fluorescein break-up time (FBUT); non-invasive break-up time (NIBUT); dry eye disease (DED) fluorescein break-up time (FBUT); non-invasive break-up time (NIBUT); dry eye disease (DED)

Share and Cite

MDPI and ACS Style

Cairns, R.; McNeely, R.N.; Dunne, M.C.M.; Gil-Cazorla, R.; Naroo, S.A.; Moore, J.E. Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis. J. Clin. Med. 2025, 14, 5794. https://doi.org/10.3390/jcm14165794

AMA Style

Cairns R, McNeely RN, Dunne MCM, Gil-Cazorla R, Naroo SA, Moore JE. Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis. Journal of Clinical Medicine. 2025; 14(16):5794. https://doi.org/10.3390/jcm14165794

Chicago/Turabian Style

Cairns, Rebecca, Richard N. McNeely, Mark C. M. Dunne, Raquel Gil-Cazorla, Shehzad A. Naroo, and Jonathan E. Moore. 2025. "Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis" Journal of Clinical Medicine 14, no. 16: 5794. https://doi.org/10.3390/jcm14165794

APA Style

Cairns, R., McNeely, R. N., Dunne, M. C. M., Gil-Cazorla, R., Naroo, S. A., & Moore, J. E. (2025). Comparing Non-Invasive and Fluorescein Tear Break-Up Time in a Pre-Operative Refractive Surgery Population: Implications for Clinical Diagnosis. Journal of Clinical Medicine, 14(16), 5794. https://doi.org/10.3390/jcm14165794

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop