Next Article in Journal
Effective Behavioural Dynamic Coupling through Echo State Networks
Previous Article in Journal
Alopecia Totalis Treated with 1064 nm Picosecond Nd:YAG Laser: A Case Report
 
 
Article
Peer-Review Record

High-Precision Light Spot Position Detection in Low SNR Condition Based on Quadrant Detector

Appl. Sci. 2019, 9(7), 1299; https://doi.org/10.3390/app9071299
by Jiawei Yu 1,2,3, Qing Li 1,2,3,4, Hongwei Li 1,2,3,4, Qiang Wang 1,2, Guozhong Zhou 1,2, Dong He 1,2, Shaoxiong Xu 1,2, Yunxia Xia 1,2 and Yongmei Huang 1,2,3,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Appl. Sci. 2019, 9(7), 1299; https://doi.org/10.3390/app9071299
Submission received: 24 January 2019 / Revised: 12 March 2019 / Accepted: 20 March 2019 / Published: 28 March 2019
(This article belongs to the Section Electrical, Electronics and Communications Engineering)

Round 1

Reviewer 1 Report

Minor changes and corrections are needed. Also, minor clarification is needed.

Comments for author File: Comments.pdf

Author Response

Thank for your suggestions, I have modified  my paper as you say.

Author Response File: Author Response.docx

Reviewer 2 Report

The title:

High-precision Light Spot Position Detection in Low SNR Condition Based on Quadrant Detector


The manuscript should be corrected:

 

·         figure 4 is too small, it is necessary to show important elements of the experimental platform on a better scale

·         lack description of calculation programs - software

·         the "KHz" sign must written as "kHz"

·         figure 6, 7, 8 - description in chinese must be changed into english

·         line 182 - ", After" ???

·         title of "table 1" must go on next page

·         Table 1 - why "mm" are in Bold

·         lack error analysis in chapter 5

·         sentences in the chapter Conclusion are too long

·         too poor references review in Introduction and list of references - only 13

·         quoted references are incomplete - lack numbers of pages, issues, etc.

 

 Conclusion: this manuscript require the correction and after that should be presented in Appl. Sci.

 

Regards


Author Response

Thanks for your suggestion, I have modified my paper as you say.

Author Response File: Author Response.docx

Round 2

Reviewer 2 Report

Analysing the presented publication "High-precision Light Spot Position Detection in Low SNR Condition Based on Quadrant Detector " and the responses to received reviews, I think, it has been significantly improved and this version of the manuscript may be submitted for publication in the Applied Sciences.

Regards


Back to TopTop