Next Article in Journal
A Survey on Learning-Based Model Predictive Control: Toward Path Tracking Control of Mobile Platforms
Next Article in Special Issue
Experimental Study on the Effect of Pile-End Soil on the Pile Load Transfer Law
Previous Article in Journal
Designing the Controller-Based Urban Traffic Evaluation and Prediction Using Model Predictive Approach
Previous Article in Special Issue
A Method for Determining the Safe Thickness of Concrete Retaining Walls Based on Slab Structure Theory
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Analysis of Horizontal Earth Pressure Acting on Box Culverts through Centrifuge Model Test

1
Department of Civil and Environmental Engineering, Incheon National University, 119, Academy-ro, Yeonsu-Gu, Incheon 22012, Korea
2
Department of Artificial Intelligence, Hannam University, 70, Hannam-ro, Daedeok-gu, Daejeon 34430, Korea
*
Author to whom correspondence should be addressed.
Appl. Sci. 2022, 12(4), 1993; https://doi.org/10.3390/app12041993
Submission received: 11 January 2022 / Revised: 7 February 2022 / Accepted: 11 February 2022 / Published: 14 February 2022
(This article belongs to the Special Issue Advances in Geotechnologies in Infrastructure Engineering)

Abstract

Underground space is being utilized due to the saturation of surface ground. The box culvert, as a representative infrastructure that has moved underground, is installed to protect such fixtures as electricity and gas. Because buried box culverts are necessarily affected by soil, it is important to study the earth pressure according to soil type. Herein, the horizontal earth pressure of the buried box culvert was analyzed. Accordingly, a precisely simulated centrifuge model test was performed. Additionally, the coefficient of earth pressure was analyzed. The results had significant variability because, in the existing theory, the horizontal earth pressure acting on the side of the box culvert was only calculated using the coefficient of earth pressure and the friction angle of the soil. Therefore, a correction factor was deemed necessary for calculating the horizontal earth pressure acting on the side of the box culvert.
Keywords: box culvert; horizontal earth pressure; centrifuge model test; variability analysis box culvert; horizontal earth pressure; centrifuge model test; variability analysis

Share and Cite

MDPI and ACS Style

Lee, K.; Kim, J.; Woo, S.I. Analysis of Horizontal Earth Pressure Acting on Box Culverts through Centrifuge Model Test. Appl. Sci. 2022, 12, 1993. https://doi.org/10.3390/app12041993

AMA Style

Lee K, Kim J, Woo SI. Analysis of Horizontal Earth Pressure Acting on Box Culverts through Centrifuge Model Test. Applied Sciences. 2022; 12(4):1993. https://doi.org/10.3390/app12041993

Chicago/Turabian Style

Lee, Kicheol, Joonyoung Kim, and Sang Inn Woo. 2022. "Analysis of Horizontal Earth Pressure Acting on Box Culverts through Centrifuge Model Test" Applied Sciences 12, no. 4: 1993. https://doi.org/10.3390/app12041993

APA Style

Lee, K., Kim, J., & Woo, S. I. (2022). Analysis of Horizontal Earth Pressure Acting on Box Culverts through Centrifuge Model Test. Applied Sciences, 12(4), 1993. https://doi.org/10.3390/app12041993

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop