Article

Optimal Design of a Coaxial Magnetic Gear Considering Thermal Demagnetization and Structural Robustness for Torque Density Enhancement

1
Department of Electronics and Information System Engineering, Sangmyung University, Cheonan 31066, Republic of Korea
2
Department of Human Intelligence and Robot Engineering, Sangmyung University, Cheonan 31066, Republic of Korea
*
Author to whom correspondence should be addressed.
Actuators 2026, 15(1), 59; https://doi.org/10.3390/act15010059
Submission received: 29 November 2025 / Revised: 12 January 2026 / Accepted: 13 January 2026 / Published: 16 January 2026

Abstract

This study presents an optimal design combined with comprehensive multiphysics validation to enhance the torque density of a coaxial magnetic gear (CMG) incorporating an overhang structure. Four high non-integer gear-ratio CMG configurations exceeding 1:10 were designed using different pole-pair combinations, and three-dimensional finite element method (3D FEM) was employed to accurately capture axial leakage flux and overhang-induced three-dimensional effects. Eight key geometric design variables were selected within non-saturating limits, and 150 sampling points were generated using an Optimal Latin Hypercube Design (OLHD). Multiple surrogate models were constructed and evaluated using the root-mean-square error (RMSE), and the Kriging model was selected for multi-objective optimization using a genetic algorithm. The optimized CMG with a 1:10.66 gear ratio achieved a 130.76% increase in average torque (65.75 Nm) and a 162.51% improvement in torque density (117.14 Nm/L) compared with the initial design. Harmonic analysis revealed a strengthened fundamental component and a reduction in total harmonic distortion, indicating improved waveform quality. To ensure the feasibility of the optimized design, comprehensive multiphysics analyses—including electromagnetic–thermal coupled simulation, high-temperature demagnetization analysis, and structural stress evaluation—were conducted. The results confirm that the proposed CMG design maintains adequate thermal stability, magnetic integrity, and mechanical robustness under rated operating conditions. These findings demonstrate that the proposed optimal design approach provides a reliable and effective means of enhancing the torque density of high gear-ratio CMGs, offering practical design guidance for electric mobility, robotics, and renewable energy applications.

1. Introduction

Magnetic gears transmit mechanical power through magnetic-field modulation, enabling non-contact torque transmission and providing inherent overload protection due to the physical separation between the input and output shafts [1,2]. Compared with conventional mechanical gears, magnetic gears offer several advantages, including reduced noise and vibration, elimination of lubrication requirements, and the absence of friction-induced wear. These features make magnetic gears well suited for long-life and maintenance-efficient operation [3,4].
Growing environmental concerns—such as fossil-fuel depletion, air pollution, and climate change—have led many regions to adopt increasingly stringent emission regulations, including Euro VII and Bharat Stage VI standards [5]. As a result, demand for electric vehicles (EVs) and renewable-energy systems has continued to increase, driving strong interest in high-efficiency and maintenance-free power-transmission technologies [6,7]. Owing to these advantages, magnetic gears have been actively investigated for a wide range of applications, including electric mobility, wind and marine energy systems, robotics, and other high-reliability systems [8,9,10].
Although magnetic gears were first introduced in the 1940s, their practical adoption remained limited for several decades due to inherently low torque density [11]. A major breakthrough was achieved in 2001 when Atallah et al. proposed the CMG, which employs concentric inner and outer rotors coupled through a ferromagnetic modulator [12]. This configuration significantly improved torque density, reaching approximately 100 kNm/m3, and stimulated extensive subsequent research on CMGs. Recent studies have focused on pole-pair selection, modulation-pole geometry, gear-ratio optimization, and flux-modulation enhancement to further improve torque characteristics [13,14,15,16,17]. In addition, previous research has demonstrated that incorporating an overhang structure and optimizing the pole-pair combination can effectively enhance the torque performance of CMGs [18].
Despite these advances, increasing the gear ratio of a single-stage CMG generally leads to a reduction in torque density. This degradation is primarily caused by increased permanent-magnet usage, enhanced leakage flux, and structural constraints associated with high gear-ratio configurations [19,20,21]. Although multi-stage magnetic gear arrangements can achieve higher gear ratios, they inevitably introduce additional system complexity, increased volume, and higher manufacturing cost. Consequently, the development of high-gear-ratio single-stage CMGs that maintain permanent-magnet usage while achieving improved torque density remains an important and challenging research problem.
Design optimization plays a critical role in addressing these limitations. The performance of CMGs is highly sensitive to geometric parameters, making the appropriate selection and optimization of design variables essential for maximizing torque density [22,23]. To efficiently explore high-dimensional design spaces, Design of Experiments (DOE) techniques are widely employed. Among them, Latin Hypercube Design (LHD) provides uniform sampling within individual variable ranges [24,25], but often suffers from insufficient uniformity in multidimensional spaces [26]. Optimal Latin Hypercube Design (OLHD) overcomes this limitation by maximizing the minimum distance between sampling points, thereby achieving superior space-filling characteristics and enabling the construction of accurate surrogate models for design optimization [27,28].
Accurate performance prediction of CMGs typically relies on the finite element method (FEM). Although two-dimensional (2D) FEM offers relatively low computational cost and fast evaluation, it cannot adequately capture axial leakage flux and overhang-induced three-dimensional (3D) effects, which leads to reduced accuracy in torque prediction for CMGs with complex geometries [29]. In contrast, three-dimensional FEM enables a more faithful representation of these phenomena and has therefore been widely adopted for high-accuracy electromagnetic evaluation of CMGs [30,31,32,33].
In addition to electromagnetic performance, operational losses inevitably generate heat within the CMG, resulting in temperature rise during operation. Elevated temperatures can degrade the magnetic properties of permanent magnets and influence overall torque performance and reliability [34,35,36]. Accordingly, electromagnetic–thermal coupled analysis is required to accurately assess temperature-dependent behavior under realistic operating conditions. Furthermore, structural analysis is necessary to verify mechanical robustness, particularly for CMGs employing overhang structures, where permanent magnets and rotor components may be subjected to increased mechanical stress during operation [37,38].
Based on these considerations, this study aims to improve the torque density of a CMG through optimal design while explicitly considering an overhang structure, and to verify the resulting performance through comprehensive multiphysics analysis. Compared with previous studies on coaxial magnetic gears that mainly focus on integer gear ratios, simplified rotor–stator geometries, or electromagnetic performance alone, this study addresses a more challenging design problem involving high non-integer gear ratios exceeding 1:10 and an overhang structure. Previous works have shown that multi-objective and surrogate-based optimization techniques can effectively enhance torque density in various magnetic gear topologies, such as flux-focusing Halbach designs [9]. However, the combined application of optimal design and comprehensive multiphysics validation to high non-integer gear-ratio CMGs has not yet been sufficiently investigated.
The main contribution of this study is to systematically elucidate the torque-density enhancement mechanisms of CMGs operating at high non-integer gear ratios by integrating surrogate-assisted optimal design with comprehensive multiphysics validation. To achieve this objective, four pole-pair combinations corresponding to gear ratios exceeding 1:10 were designed and evaluated using 3D FEM. OLHD was employed to generate sampling points for surrogate-model construction, and multiple regression techniques were compared using the root-mean-square error (RMSE) to identify the most accurate surrogate model. A genetic algorithm was then applied to determine the optimal set of design variables. The optimized configuration was validated through electromagnetic analysis, harmonic evaluation, electromagnetic–thermal coupled simulation, demagnetization analysis, and structural analysis. The results demonstrate significant improvements in torque density and confirm the reliability of the optimized CMG design.
Although experimental validation using a physical prototype is not included in this study, the proposed CMG with an overhang structure exhibits substantial geometric complexity and pronounced three-dimensional flux leakage, which limit the applicability of simplified magnetic equivalent circuit (MEC) models. Therefore, three-dimensional FEM combined with comprehensive multiphysics analysis was adopted to reliably evaluate the sensitivity of torque characteristics to discrete gear-ratio variations and to assess the physical feasibility of the optimized design.
The remainder of this paper is organized as follows.
Section 2 describes the initial CMG design, including the four pole-pair combinations, and presents the preliminary electromagnetic analysis.
Section 3 outlines the optimal design procedure, including sampling strategies, sensitivity analysis, surrogate modeling, and the genetic algorithm–based optimization process.
Section 4 presents the multiphysics validation results, including electromagnetic, thermal, demagnetization, and structural analyses.
Section 5 discusses the results and provides a comparative discussion of the proposed CMG design in relation to previously published studies.
Section 6 concludes the paper and outlines future research directions.

2. Magnetic Gear

2.1. Initial Design

Previous study has demonstrated that incorporating an overhang structure and selecting appropriate pole-pair combinations can enhance the torque characteristics of CMGs [18]. Building upon these reported findings, the present work extends an earlier CMG design with a gear ratio of 1:4.2 to investigate a higher gear-ratio CMG targeting a ratio of approximately 1:10.2. Accordingly, the initial geometric design parameters were adopted from the previously validated model, while the pole-pair configuration and gear ratio were adjusted to explore torque amplification behavior at higher gear ratios.
Because the torque performance of CMGs is strongly influenced by pole-pair selection, several pole-pair combinations were examined to identify configurations that can yield relatively high torque density. Although prior studies have generally reported that torque density tends to decrease as the gear ratio increases, this study seeks to mitigate this tendency through systematic optimal design, with the aim of achieving improved torque density even at high gear ratios.
The geometry and corresponding rotor configuration of the initial CMG model are shown in Figure 1, while the detailed dimensions and model specifications of the design variables, adopted from a previously validated study, are summarized in Table 1. The CMG consists of three primary components: (1) Rotor 1, which receives the input torque; (2) Rotor 2, which delivers the amplified output torque; and (3) Rotor 3, a stationary ferromagnetic modulator that provides structural support and facilitates magnetic flux modulation. All baseline dimensions and electromagnetic specifications were adopted from the previously validated CMG model to maintain consistency and ensure fair comparative evaluation.
In the design of CMGs, numerous studies have focused on increasing torque density while simultaneously reducing torque ripple. Among the parameters influencing these characteristics, the gear ratio plays a critical role in determining both the achievable torque density and the magnitude of torque ripple. When an integer gear ratio is employed, CMGs tend to exhibit reduced torque density and increased torque ripple due to the periodic alignment of interacting spatial harmonics. In contrast, non-integer gear ratios disrupt this harmonic alignment, which can lead to enhanced torque density and reduced torque ripple. For this reason, non-integer gear ratios are generally preferred in CMG designs that require high torque performance with minimized ripple.
When Rotor 3 is fixed, as assumed in this study, the pole-pair number of Rotor 3 and the number of modulation pole pieces can be determined using Equations (1) and (2), respectively. The pole-pair number of Rotor 3, denoted as P 3 , is calculated as:
P 3 | w 3 = 0 = { ( G i 1 ) P 1 + 1   f o r   G 1 P 1   o d d   ( G i 1 ) P 1 + 2   f o r   G 1 P 1   e v e n
The number of ferromagnetic modulation pole pieces, denoted as Q 2 , is determined by the sum of the pole-pair numbers of Rotors 1 and 3 and can be expressed as:
Q 2 = P 1 + P 3
In Equations (1) and (2), P 1 denotes the pole-pair number of Rotor 1, and P 3 represents that of Rotor 3. The parameter G i is the target gear ratio specified for the CMG design, while Q 2 corresponds to the number of ferromagnetic modulation pole pieces. The angular velocities of Rotors 1 and 2 are denoted by ω 1 and ω 2 , respectively. Rotor 3 is assumed to be stationary, and thus its angular velocity is given by ω 3 = 0 .
Under this condition, the resulting gear ratio of the CMG can be expressed as:
G | w 3 = 0 = W 1 W 2 = Q 2 P 1
and by substituting Equations (1) and (2) into this relationship, the final expression for the CMG ratio is obtained, as given in Equation (3).

2.2. High Gear Ratio

The torque characteristics of a CMG are strongly influenced by the selected gear ratio. To investigate high gear-ratio configurations near the target value of G i = 10 , four pole-pair combinations were defined according to Equations (1)–(3), including the initial 1:10.2 model.
All four CMG models share identical geometric dimensions and baseline design parameters listed in Table 1, and differ only in their pole-pair combinations. The corresponding values of P 1 , Q 2 and P 3 for each configuration are summarized in Table 2, and the geometric layouts of the four CMG models are illustrated in Figure 2.

2.3. Initial Analysis

To evaluate the electromagnetic performance of the four CMG configurations defined in Section 2.2, three-dimensional FEM simulations were performed using ANSYS Maxwell (v2025 R2). To ensure sufficient numerical accuracy, each CMG model was discretized into approximately 300,000 finite elements. The rated rotational speed of Rotor 1 was set to 1000 rpm, while the rated rotational speed of Rotor 2 was determined from the corresponding gear ratio using Equation (4). Rotor 3 was assumed to be stationary throughout the analysis.
Under the condition ω 3 = 0 , the rated rotational speed of Rotor 2 can be expressed as:
S 2 | w 3 = 0 =   S 1 Q 2 / P 1
where S 1 and S 2 denote the rated rotational speeds of Rotors 1 and 2, respectively.
Initial electromagnetic analyses were conducted for all four CMG models, which share identical geometric parameters except for their pole-pair combinations. The resulting average torque, model volume, and torque density obtained from the 3D FEM simulations are summarized in Table 3. All four models were designed with the same permanent-magnet volume to ensure a fair and consistent comparison. Because all angular parameters were defined in electrical degrees, appropriate conversions to mechanical degrees were applied according to the pole-pair configuration of each model.
Among the four configurations, the 1:10.2 gear-ratio model exhibited the lowest torque performance, producing an average torque of 28.49 Nm, a torque ripple factor of 6.63%, and a torque density of 30.65 Nm/L.

3. CMG Optimization

To enhance the torque density of the CMG, an optimal design procedure was established to determine the optimal values of key design variables within a constrained design space. The four CMG configurations developed in Section 2—including the initial model and three additional pole-pair combinations—were each subjected to the same optimal design procedure to enable a consistent and comparative assessment. The overall optimal design process employed in this study is illustrated in Figure 3.
The optimal design process begins with the initial CMG design, followed by the selection of appropriate design variables and the specification of their feasible ranges. Sampling points within these ranges were generated using OLHD, a DOE technique that provides superior space-filling properties. Each sampling point was evaluated using three-dimensional FEM to obtain electromagnetic performance data, while a design sensitivity analysis was conducted in parallel to quantify the influence of each design variable on key output characteristics. Based on these analyses, the objective function and design constraints for the optimal design problem were defined.
To reduce the computational burden associated with repeated FEM simulations, surrogate models were constructed using the sampled FEM data to approximate the input–output behavior of the CMG. Among the surrogate candidates, the model demonstrating the highest prediction accuracy was selected. This surrogate model was then employed to determine the optimal design solution that satisfies both the objective function and the imposed constraints. The resulting optimal design variables were subsequently applied to construct the optimized CMG model.
Finally, comprehensive multiphysics validation—including electromagnetic, thermal, and structural analyses—was performed to verify the reliability and feasibility of the optimized design. If the validation results did not satisfy the prescribed performance criteria, the optimal design loop was repeated until convergence was achieved. Once all criteria were met, the optimal design procedure was concluded.
Selecting appropriate design variables is essential, as these parameters strongly influence both the electromagnetic and mechanical behavior of the CMG. In this study, eight adjustable design variables were selected with the objective of maximizing torque density while maintaining sufficient average output torque.
The eight design variables considered in this optimal design are illustrated in Figure 4 and defined as follows:
X1: overhang length, X2: pole piece length, X3: PM electrical degree, X4: arc angle of the outer pole piece, and X5: arc angle of the inner pole piece, X6: outer radius, X7: air gap, X8: hole position of the rotor 1.
First, CMGs inherently exhibit significant axial flux leakage. Previous studies have shown that incorporating an overhang structure can mitigate axial leakage and increase output torque. Accordingly, the overhang length was selected as one of the optimal design variables.
Second, the geometry of the modulation pole pieces plays a critical role in determining the torque characteristics of a CMG. In addition, the air-gap length around Rotor 2 directly influences magnetic coupling and torque production. Therefore, the pole-piece length, pole-piece arc angles, and air-gap length were included as optimal design variables.
Third, the arc angle of the permanent magnet (PM) affects torque performance. However, increasing PM volume to enhance torque also increases mass and material cost. To maintain constant PM usage while improving electromagnetic characteristics, the electrical arc angle of the PM was selected as an optimal design variable.
Fourth, CMGs typically incorporate openings in the rotor or housing for mounting or mechanical protection. These openings modify the magnetic flux paths and can influence torque generation. Consequently, the hole position on Rotor 1 was included as an optimal design variable to evaluate its impact on electromagnetic behavior.
Finally, maximizing torque density requires minimizing unnecessary volume. Reducing the outer radius decreases the overall size of the CMG and directly enhances torque density. Thus, the outer radius was also selected as an optimal design variable.
For effective optimal design, appropriate ranges must be defined for all design variables to prevent magnetic saturation under the intended operating conditions. The initial values and allowable ranges for the eight design variables considered in this study are summarized in Table 4.
Specifically, the overhang length X 1 was varied from 0 to 30 mm, while the pole-piece length X 2 was defined within the range of 4–12 mm. The PM arc angle X 3 , the outer pole-piece arc angle X 4 , and the inner pole-piece arc angle X 5 were all specified in electrical degrees and allowed to vary from 100° to 180°. The outer radius X 6 was constrained to the range of 70–90 mm, and the air-gap length X 7 was set between 0.5 and 1.0 mm. Finally, the hole position of Rotor 1, represented by X 8 , was defined within the range of 17–33.5 mm.

3.1. Sampling and Design Sensitivity Analysis

To maximize the torque density of the CMG, the optimal design process was carried out using the eight design variables identified in the previous subsection. Conducting an optimal design solely through repeated FEM simulations is computationally demanding and becomes impractical for high-dimensional design problems. Therefore, reducing computational cost while maintaining predictive reliability is essential in optimal design [39]. To address this challenge, surrogate modeling techniques were employed due to their high computational efficiency and suitability for engineering design applications.
Sampling points for surrogate-model construction were generated using OLHD, a DOE method that maximizes the minimum distance between sampling points and provides excellent space-filling characteristics within the design domain. The number of sampling points required for surrogate-model construction was estimated using the empirical guideline given in Equation (5), which has been widely adopted in response surface–based surrogate modeling studies [40]. In this equation, n E X P denotes the number of required minimum sampling points, and n D V represents the number of design variables. In this study n D V is 8.
n E X P     1.5 × ( n D V + 1 ) × ( n D V + 2 ) 2
Using Equation (5), the minimum required number of sampling points for eight design variables was calculated to be 67.5. To enhance the accuracy and robustness of the surrogate models, a substantially larger number of sampling points was employed in this study. Specifically, 150 OLHD points—more than twice the minimum requirement—were used for surrogate-model construction. Using the 150 generated sampling points, all four CMG models were evaluated using 3D FEM to obtain the corresponding electromagnetic performance datasets. The sampling results are summarized in Table 5. Among the four candidates, the CMG model with a gear ratio of 1:10.66 exhibited the highest average torque of 42.23 Nm and the highest torque density of 72.53 Nm/L. These results indicate that, within the investigated design space, higher gear ratios tend to yield improved torque performance. Accordingly, the 1:10.66 CMG model, which showed the most favorable sampled performance, was selected as the primary target for the subsequent optimal design procedure.
Using the sampled data, a Design Sensitivity Analysis (DSA) was conducted to quantify the influence of each design variable on the output characteristics of the CMG. The DSA results for the four CMG configurations are presented in Figure 5.
Among all design variables, X 6 (outer radius) exhibited the highest sensitivity, accounting for more than 40% of the total influence in all four CMG models. This result indicates that the outer radius has a dominant effect on the overall CMG volume and, consequently, on torque density.
In addition, for the target CMG model selected for the subsequent optimal design, the variables X 1 (overhang length) and X 2 (pole-piece length) contributed approximately 4.8% and 10.9%, respectively, to the variation in average torque. These findings confirm that both variables play an important role in determining CMG performance and should therefore be treated as key parameters in the optimal design process.

3.2. Optimal Design

Using the 150 sampling points generated in the previous subsection, the optimal design procedure was carried out by constructing surrogate models based on the sampled FEM data. Five surrogate modeling techniques were employed to approximate the relationships between the design variables and the corresponding performance outputs: Kriging (KRG), multilayer perceptron (MLP), ensemble of decision trees (EDT), polynomial regression (PRG), and radial basis function regression (RBF).
Because surrogate models are introduced to significantly reduce computational cost compared with direct FEM-based evaluations, their prediction accuracy directly affects the reliability of the optimal design results. Therefore, a quantitative assessment of surrogate model accuracy is essential prior to their use in the optimal design stage.
The prediction accuracy of the surrogate models was evaluated using the root-mean-square error (RMSE), defined in Equation (6) [41,42]. A total of 150 design points were generated using the OLHD method. Among these, 90% of the data (135 points) were used for surrogate model training, while the remaining 10% (15 points) were randomly selected as independent test points for validation. RMSE quantifies the average deviation between predicted and actual values by computing the square root of the mean squared difference. In Equation (6), n denotes the number of test points, y ( X i ) represents the actual FEM results, and y ^ ( X i ) denotes the corresponding predictions obtained from the surrogate model.
R M S E = 1 n i = 1 n [ y ( X i ) y ^ ( X i ) ] 2
A lower RMSE value indicates better predictive performance. Accordingly, the surrogate model yielding the lowest RMSE was selected as the most suitable model for use in the subsequent optimal design procedure. RMSE values were evaluated for three key performance metrics—average torque, torque ripple, and CMG volume—to ensure that the selected surrogate model provided consistent accuracy across all critical outputs. The RMSE results obtained for each surrogate model and each pole-pair configuration are summarized in Table 6. Because the RMSE values are reported in the physical units of the corresponding performance metrics, they should be interpreted with respect to each individual metric rather than through direct numerical comparison across different performance variables.
In this study, the Kriging model was adopted as the surrogate model for the optimal design procedure based on a comparative evaluation of multiple surrogate modeling approaches. The Kriging model employs an interpolation-based framework and provides not only the predicted mean response but also the predictive variance, enabling explicit quantification of model uncertainty. Owing to its high data efficiency and strong capability to capture nonlinear responses with a limited number of training samples, Kriging has been widely applied in FEM-based optimal design problems [42].
Furthermore, the variance-minimization property of Kriging makes it particularly suitable for the present CMG optimization problem, in which pronounced nonlinear behavior and numerical noise are observed due to complex magnetic interactions and 3D FEM discretization effects [43].
Although the objective function in this study assigns equal weights to average torque and volume to enhance torque density, the selection of the surrogate model was guided by the distinct characteristics of the corresponding response variables. Average torque exhibits pronounced nonlinearity and high sensitivity to the design variables, whereas the volume is primarily governed by geometric parameters and shows a comparatively smooth and near-linear response. As indicated by the RMSE results summarized in Table 6, the Kriging model achieved the lowest prediction error for the average torque response, which represents the more nonlinear and optimal-design-sensitive objective in this study. For problems involving complex and nonlinear input–output relationships, surrogate models with flexible covariance structures, such as the Kriging model, have been shown to outperform simpler polynomial-based approaches in terms of predictive accuracy and robustness [44].
The objective function and design constraints used for the optimal design are defined in Equations (7) and (8). Because the primary goal of this study is to enhance the torque density of the CMG, the optimal design problem was formulated to maximize the average torque while simultaneously minimizing the model volume. Owing to the multi-objective nature of the problem, equal weighting factors were assigned to the two objectives, as both directly contribute to improving torque density. The design constraints were derived from the initial 3D FEM results listed in Table 3 to ensure that the resulting optimized design remains within an acceptable torque-characteristic range while achieving improved performance.
Specifically, for the selected CMG model with a gear ratio of 1:10.66, the optimal design was required to exceed the initial average torque of 42.164 Nm while constraining the torque ripple to be lower than 2.072 Nm.
O b j e c t i v e   F u n c t i o n = { Maximize   Average   Torque × 0.5 Minimize   Volume × 0.5
C o n s t r a i n t s = { Average   Torque > 42.164   Nm Torque   Ripple < 2.072   Nm
To enable a fair comparison of optimal design performance, all four CMG models were subjected to the same optimal design conditions. The initial values of the design variables for each model were derived from their respective baseline configurations. Using the objective function and design constraints defined in Equations (7) and (8), a genetic algorithm (GA) was employed to identify the optimal set of design variables.
GA is well suited for multi-objective optimal design problems encountered in electrical machine applications, as it efficiently explores high-dimensional design spaces while accommodating nonlinear constraints. When combined with surrogate modeling, GA substantially reduces the computational burden associated with repeated FEM evaluations and facilitates the identification of reliable optimal solutions [45].
For each of the four CMG configurations, the GA was executed for 500 iterations to ensure convergence toward a near-global optimum. The convergence behavior of the design variables during the optimal design process is illustrated in Figure 6.
The optimal design solutions obtained using the GA-based procedure are summarized in Table 7. Consistent with the results of the design sensitivity analysis, the outer radius X 6 , which exhibited the highest sensitivity, converged to 70 mm for all four CMG models. This reduction from the initial value reflects the volume-minimization objective and confirms that decreasing the outer radius is essential for improving torque density.
All four CMG models satisfied the imposed design constraints on average torque and torque ripple. Among the evaluated configurations, the CMG model with a gear ratio of 1:10.66, which was selected as the target for optimal design, showed the best overall performance. In particular, the optimized 1:10.66 model achieved an average torque of 65.09 Nm, a torque ripple of 2.07 Nm, and a volume of 897,503.09 mm3, corresponding to the highest torque output among the four optimally designed CMG models.
The magnetic flux density distributions of the initial and optimized CMG models are shown in Figure 7 and Figure 8, respectively. The overall flux distributions are presented in the isometric views in Figure 7a and Figure 8a. The top views in Figure 7b and Figure 8b emphasize the radial flux paths and clearly illustrate the dimensional differences between the two designs. As shown in these figures, the outer radius X 6 was reduced by 20 mm in the optimized design compared with the initial model. This reduction removes unnecessary iron volume in Rotor 3 and results in a significant decrease in the overall CMG volume.
The front views in Figure 7c and Figure 8c reveal the axial flux leakage, which cannot be accurately evaluated using 2D FEM. The 3D FEM results indicate a noticeable reduction in axial flux leakage in the optimized model. In addition, the electrical arc angle of the permanent magnets differs by approximately 6° between the initial and optimized designs, leading to a more concentrated magnetic flux distribution in the optimized structure.
Compared with the initial model, the optimized design exhibits a more compact and concentrated flux distribution within the core region. Localized peak flux-density values are observed near geometric discontinuities; however, these are a natural consequence of flux concentration and localized field intensification associated with volume reduction and torque-density enhancement, rather than indicators of physically unrealistic magnetic saturation.
To ensure physically meaningful evaluation, the magnetic flux density distributions were visualized by limiting the color scale to the range of 0–2.5 T during 3D FEM post-processing. This range corresponds to the physically relevant saturation level of the employed ferromagnetic core material. As a result, localized peak values exceeding this range may appear near sharp edges or geometric discontinuities. It should be noted, however, that such localized peaks do not represent effective magnetic loading, but are instead recognized as numerical singularities inherent to finite-element discretization. Since performance evaluation relies on spatially distributed flux-density levels within the bulk core region, these non-representative local peaks were excluded from the magnetic flux density assessment.

4. Multiphysics Validation

To ensure the reliability and technical validity of the optimal design, comprehensive multiphysics validation was performed on the CMG model constructed using the optimal design variables. During operation, electromagnetic energy-conversion devices inevitably generate losses, such as core loss and copper loss, which lead to temperature rise. Elevated temperatures can degrade the magnetic properties of permanent magnets and ferromagnetic materials, thereby affecting overall performance. Consequently, thermal analysis in conjunction with electromagnetic analysis is essential for accurate performance validation.
To account for temperature-dependent magnetic degradation, an electromagnetic–thermal coupled analysis was conducted. In addition, a demagnetization analysis was performed to evaluate the robustness of the permanent magnets under elevated temperature. Finally, structural analysis was carried out to verify the mechanical integrity of the CMG under operating torque conditions.
In this study, the optimized CMG design was evaluated using the following procedures:
(1)
comparative three-dimensional FEM electromagnetic analysis;
(2)
fast Fourier transform (FFT) analysis of the air-gap flux density;
(3)
electromagnetic–thermal coupled analysis;
(4)
demagnetization analysis; and
(5)
structural analysis.
These combined analyses provide comprehensive multiphysics validation for the optimized CMG design. The use of three-dimensional multiphysics FEM effectively compensates for the absence of an experimental prototype by capturing complex three-dimensional phenomena. In particular, this approach accounts for nonlinear interactions among electromagnetic losses, temperature-induced magnetic degradation, and structural responses, which are critical for validating the feasibility of the proposed overhang structure.

4.1. Electromagnetic Analysis

The first stage of the multiphysics validation focused on evaluating the electromagnetic performance of the optimized designs. Using the optimal design variables, three-dimensional FEM simulations were performed for all four CMG configurations to allow direct comparison. Rotor 1 was operated at a fixed rated speed of 1000 rpm, while the rated speeds of the remaining rotors were determined using Equation (4). To ensure sufficient numerical accuracy, each CMG model was discretized into approximately 300,000 finite elements.
The electromagnetic validation results for the four optimized configurations are summarized in Table 8. All models exhibited substantial improvements in torque density compared with the initial FEM results presented in Table 3.
Among the four configurations, the optimized CMG model with a gear ratio of 1:10.66 exhibited the highest overall performance. The average torque increased to 65.75 Nm, representing an improvement of approximately 55% compared with the initial design. In addition, the torque ripple factor decreased to 4.57%, corresponding to a reduction of about 0.34%. Most notably, the torque density increased to 117.14 Nm/L, which represents a significant enhancement of approximately 162.51% relative to the initial design. These results confirm that reducing the outer radius X 6 , identified as the most volume-sensitive design variable, effectively decreased the CMG volume and played a dominant role in improving torque density.
To further compare the torque characteristics of the initial and optimal models, electromagnetic simulations were conducted under identical operating conditions. The resulting torque–time waveforms are shown in Figure 9. The initial model produced an average torque of 28.49 Nm, whereas the optimal model achieved a substantially higher average torque of 65.75 Nm, corresponding to an improvement of approximately 130.76%.
Design sensitivity analysis revealed that overhang length X 1 is the most influential variable affecting the average torque. Increasing the overhang length reduced axial leakage flux, leading to a significant enhancement in torque output compared with the initial design. Furthermore, the torque ripple factor was reduced by approximately 2.06%, confirming that the optimized CMG design provides not only higher torque output but also improved torque stability.
To evaluate the effect of the optimal design on the harmonic characteristics of the CMG, the frequency components of the air-gap magnetic flux density were analyzed for both the initial and optimized models using total harmonic distortion (THD). The comparison results are presented in Figure 10. Figure 10a shows the air-gap magnetic flux density waveforms, while Figure 10b presents the corresponding FFT spectra expressed in absolute amplitudes.
As observed in Figure 10a, the optimized model exhibits a higher peak flux density than the initial model. This increase in absolute amplitude is a natural physical consequence of the flux-concentration strategy adopted in the optimal design process to maximize torque density. Accordingly, priority was given to enhancing the fundamental harmonic component, which plays the dominant role in torque production, as confirmed in Figure 10b.
The FFT results indicate that the fundamental component accounts for 53.08% of the total spectrum in the initial model and 54.57% in the optimized model. In terms of absolute amplitude, the fundamental component increased by 49.78% after applying the optimal design. Although the absolute amplitudes of some harmonic components also increased, the growth rate of the fundamental component was significantly higher. Specifically, while the fundamental component increased by 49.78%, the 3rd- and 5th-order harmonics increased by 29.39% and 20.79%, respectively, whereas the 7th- and 9th-order harmonics decreased in magnitude.
Consequently, when the harmonic content is evaluated relative to the fundamental component, the total harmonic distortion (THD)—defined as the ratio of the combined harmonic components to the fundamental component—decreased from 43.05% in the initial model to 38.63% in the optimized model, corresponding to a reduction of 4.42%. These results confirm that the optimized CMG design exhibits a more dominant fundamental component and reduced magnetic flux distortion.
Overall, despite the increase in the absolute amplitudes of certain harmonic components, the harmonic analysis demonstrates an improvement in waveform quality. This indicates that the optimized CMG design effectively concentrates the increased magnetic energy into the fundamental component, thereby achieving enhanced torque density.

4.2. Electromagnetic–Thermal Coupling Analysis

During operation, the temperature of the CMG increases due to electromagnetic losses, including eddy current losses and magnetic core losses generated in the conductive structural components. Since the CMG does not incorporate armature windings, copper loss was not considered in this analysis. The resulting temperature rise may degrade the magnetic properties of the permanent magnets and ferromagnetic materials, thereby affecting the overall performance of the device. Accordingly, it is necessary to evaluate not only the electromagnetic characteristics but also the thermal behavior of the CMG. In this study, electromagnetic and thermal analyses were integrated through a coupled simulation framework. The loss components considered include hysteresis loss and classical eddy current loss in the ferromagnetic materials, which were calculated using a FEM-based loss model. To represent realistic thermal conditions and ensure structural consistency, the cap and housing structures required for practical CMG fabrication were applied to both the initial and optimized models. The geometries of the two models used for the electromagnetic–thermal coupled analysis are shown in Figure 11.
To evaluate both the electromagnetic and thermal characteristics of the structurally reinforced CMG, an electromagnetic–thermal coupled analysis was performed using a two-way coupling approach between ANSYS Maxwell and Icepak (v2025 R2). In this framework, the electromagnetic losses calculated in Maxwell were transferred to Icepak to perform thermal analysis. The resulting temperature distribution obtained from Icepak was then fed back into Maxwell, where temperature-dependent material properties were updated iteratively [46,47]. Through this two-way coupling process, the mutual interactions between the electromagnetic fields and thermal behavior were fully captured, enabling accurate prediction of both heat distribution and magnetic flux characteristics.
The electromagnetic analysis results of the two CMG models, obtained from three-dimensional FEM, are summarized in Table 9. For the initial model, the inclusion of the cap and housing resulted in a reduction in average torque and an increase in the ripple factor compared with the configuration without these structures. In contrast, for the optimized model, the average torque increased after the cap and housing were added, showing an improvement of approximately 0.31 Nm. Torque density was not evaluated in this comparison because the inclusion of the cap and housing increases the overall CMG volume, making torque-density comparison inappropriate in this context.
In this study, multiphysics simulations were performed in which the electromagnetic losses calculated using ANSYS Maxwell were transferred to Icepak to conduct a 600 s electromagnetic–thermal coupled analysis. This analysis investigates the temperature evolution of the CMG in the absence of active cooling. Figure 12 and Figure 13 present the transient temperature distributions of the initial and optimized CMG models at the end of the simulation ( t = 600 s). The simulation duration was intentionally selected to capture the transient thermal response under rated operating conditions, rather than the steady-state temperature distribution.
In each figure, subfigure (a) presents a front view with a semi-transparent rendering of the CMG geometry to visualize the internal temperature distribution. Subfigure (b) shows the corresponding thermal field alone from the same viewing direction, with the CMG geometry removed for clarity. Subfigure (c) provides an isometric view illustrating both the temperature distribution and the three-dimensional CMG structure.
In electrical machinery, the thermal time constant is typically much longer than the electromagnetic time scale and reaching steady-state thermal equilibrium therefore requires a significantly longer simulation time. For this reason, finite-duration transient thermal analysis is widely adopted to evaluate temperature evolution and to compare the thermal behavior of different designs in a computationally efficient manner [48,49]. Accordingly, the 10 min analysis period employed in this study is sufficient to capture the dominant temperature-rise characteristics of the CMG.
As the initial condition for the thermal analysis, an ambient temperature of 20 °C was applied to both models. For the initial model, the maximum temperature rise observed during the 10 min simulation was 0.82 °C. Under the same operating and boundary conditions, the optimized model exhibited a higher maximum temperature increase of 1.57 °C compared to the initial model. These results indicate that, under the considered operating conditions, both models experience only minor temperature elevation, and no significant thermal issues are expected.
To further illustrate the transient thermal behavior of the CMG, the time evolution of the maximum temperature rise over the 10 min simulation interval is compared for the initial and optimized models. The corresponding temperature evolution curves are presented in Figure 14. Plotting both curves on the same axis highlights differences in thermal response and enables direct visual comparison of the transient thermal trends.
In the optimized model, a higher temperature rise is observed compared to the initial model due to volume reduction, increased torque density, and magnetic flux concentration. Nevertheless, the maximum temperature reached at the end of the simulation (21.57 °C) remains well below the thermal degradation limits of the employed materials. Specifically, the maximum operating temperature of the permanent magnet used in this study (Arnold N35UH) is approximately 180 °C, while the allowable temperature limit of commonly used Class F insulation is 155 °C. These results confirm that the observed temperature rise remains within a sufficiently safe operating range.
Moreover, the stable thermal response provides physical cross-validation of the electromagnetic analysis. If unrealistically high magnetic saturation had occurred, a sharp increase in iron losses would have resulted in a rapid and excessive temperature rise. However, the absence of such thermal behavior indicates that the magnetic flux density within the core remains within a physically realistic range. Consequently, the coupled electromagnetic–thermal analysis confirms the electromagnetic and thermal reliability of the optimized CMG design.
Based on the electromagnetic–thermal coupled analysis, no noticeable thermal issues were observed under nominal operating conditions. Nevertheless, to conservatively assess the long-term reliability and thermal robustness of the permanent magnets, an additional demagnetization analysis was conducted under a more severe condition in which the CMG was exposed to a fixed temperature of 150 °C. The resulting demagnetization characteristics are presented in Figure 15.
The demagnetization factor was calculated using Equation (9), where a value closer to 100% indicates a higher degree of demagnetization:
D e m a g _ C o e f   [ % ] =   1 ( B r 1 B r 0 ) × 100
Here, B r 0 denotes the initial remanent flux density, and B r 1 represents the remanent flux density retained by the magnet after exposure to the specified thermal condition.
As shown in Figure 15, the maximum demagnetization factor was 3.125%, which lies within an acceptable range when compared with previously reported results obtained under similar temperature conditions [36]. These results indicate that the proposed optimal CMG design, which employs a permanent-magnet protrusion to reduce leakage flux, maintains sufficient magnetic integrity and limits performance degradation even under elevated thermal conditions. This confirms the thermal stability and reliability of the optimized CMG design.

4.3. Structural Analysis

A structural analysis was performed to verify the mechanical robustness of the optimally designed CMG, whose geometry was modified to enhance torque density. Under external loads, the CMG may experience deformation, resulting in internal stress that can degrade performance or reduce operational durability. If the induced stress exceeds the material yield strength, permanent structural damage may occur. Therefore, it is essential to ensure that the stress levels remain below the yield limits of the constituent materials under rated operating conditions [50]. Because the proposed CMG employs an overhang structure in which the permanent magnets protrude beyond the core surface, this geometry may be more susceptible to mechanical deformation. For this reason, a detailed structural evaluation was conducted.
The structural analysis results for the optimized CMG model are presented in Figure 16 and Figure 17. Figure 16 shows the von Mises stress distribution in the permanent magnet region, while Figure 17 illustrates the corresponding stress distribution in the ferromagnetic core. The analysis was performed under the rated operating condition of 1000 rpm for Rotor 1. The permanent magnets were modeled using NdFeB (Arnold N35UH), which has a yield strength corresponding to a von Mises stress of 85 MPa. The computed von Mises stress in the permanent magnets remained well below this limit, confirming structural stability. Similarly, the core was modeled using JFE Steel 20JNEH1500, which has a yield strength corresponding to a von Mises stress of 374 MPa. The von Mises stress in the core also remained far below the yield threshold.
Quantitatively, the maximum von Mises stresses observed in the permanent magnets and the core were 0.0961 MPa and 0.0972 MPa, respectively. Both values are several orders of magnitude lower than the corresponding material yield strengths, demonstrating that the optimized CMG model maintains sufficient structural integrity under the specified operating conditions. These results analytically confirm that, although the permanent magnets protrude from the core due to the overhang structure, the CMG retains adequate mechanical robustness.

5. Discussion

Overall, the proposed optimal design significantly enhances the torque density of the CMG while maintaining thermal and mechanical robustness. To place the optimized performance in a broader context, the present CMG design is compared qualitatively and quantitatively with representative magnetic gear optimization studies reported in the literature. It should be noted that direct numerical comparisons are inherently limited because the reference designs were developed under different operating conditions, material properties, and geometric constraints. Nevertheless, meaningful insights can be obtained by examining relative performance trends.
For example, surrogate-based multi-objective optimal design of flux-focusing Halbach coaxial magnetic gears reported in [9] achieved a high volumetric torque density (VTD) of 411 Nm/L. In addition, parametric optimal design of axial magnetic gears with Halbach arrays in [51] improved the torque density from 78.1 Nm/L to 93.3 Nm/L, corresponding to a 19% increase.
In this context, the proposed high non-integer gear-ratio CMG with an overhang structure achieves a torque density of 117.14 Nm/L, which is approximately 23.84 Nm/L higher than the optimized result reported in [51]. Although the absolute VTD reported in [9] is higher owing to the specific flux-focusing topology, the proposed CMG design demonstrates a substantially larger relative improvement. Specifically, the torque density increased by 162.51% compared with the initial design, which significantly exceeds the improvement rates reported in [9] and [51]. This result highlights that the overhang-based CMG configuration provides an effective and robust platform for achieving substantial torque-density enhancement, despite the increased analytical complexity associated with three-dimensional multiphysics behavior.
A quantitative comparison of torque density and improvement rates between the proposed optimal design and the reference studies is summarized in Table 10.

6. Conclusions

This study presented a comprehensive multiphysics analytical validation to demonstrate torque-density enhancement through an optimal design approach applied to a challenging CMG configuration involving high non-integer gear ratios and an overhang structure. Four high gear-ratio CMG models were designed using different pole-pair combinations, and 3D FEM was employed to accurately capture axial leakage flux and overhang-induced 3D effects. 8 key design variables were sampled using OLHD, and the Kriging model was selected as the most accurate surrogate model based on RMSE evaluation. Using this surrogate model in conjunction with a genetic algorithm, optimal design solutions satisfying all prescribed performance constraints were obtained.
The optimized CMG model with a gear ratio of 1:10.66 exhibited substantial performance improvements, including a 130.76% increase in average torque and a 162.51% enhancement in torque density compared with the initial design. Harmonic analysis confirmed a reduction in total harmonic distortion, electromagnetic–thermal coupled analysis indicated negligible temperature rise under rated operating conditions, high-temperature demagnetization analysis demonstrated acceptable magnetic stability, and structural analysis verified that the induced stresses remained far below the material yield limits.
Future work will focus on prototype fabrication and experimental validation to further confirm the effectiveness of the proposed optimal design. Additionally, harmonic characteristics, geometric refinement and skewing strategies will be investigated to further reduce torque ripple. With continued development, CMGs are expected to serve as efficient and environmentally friendly power-transmission technologies for applications such as electric vehicles, robotics, and renewable energy systems.

Author Contributions

Conceptualization, T.-K.J.; methodology, T.-K.J.; validation, S.-W.B.; investigation, T.-K.J.; writing—original draft preparation, T.-K.J.; writing—review and editing, S.-W.B.; supervision, S.-W.B.; project administration, S.-W.B.; funding acquisition, S.-W.B. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the 2025 and 2026 Research Grants from Sangmyung University.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The original contributions presented in the study are included in the article, and further inquiries can be directed to the corresponding author.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Gardner, M.C.; Praslicka, B.; Johnson, M.; Toliyat, H.A. Optimization of Coaxial Magnetic Gear Design and Magnet Material Grade at Different Temperatures and Gear Ratios. IEEE Trans. Energy Convers. 2021, 36, 2493–2501. [Google Scholar] [CrossRef]
  2. Filippini, M.; Alotto, P. Coaxial Magnetic Gear Design and Optimization. IEEE Trans. Ind. Electron. 2017, 64, 9934–9942. [Google Scholar] [CrossRef]
  3. Uppalapati, K.K.; Bomela, W.B.; Bird, J.Z.; Calvin, M.D.; Wright, J.D. Experimental Evaluation of Low-Speed Flux-Focusing Magnetic Gearboxes. IEEE Trans. Ind. Appl. 2014, 50, 3637–3643. [Google Scholar] [CrossRef]
  4. Uppalapati, K.K.; Calvin, M.D.; Wright, J.D.; Pitchard, J.; Williams, W.B.; Bird, J.Z. A Magnetic Gearbox With an Active Region Torque Density of 239 N·m/L. IEEE Trans. Ind. Appl. 2018, 54, 1331–1338. [Google Scholar] [CrossRef]
  5. Sathiyan, S.P.; Pratap, C.B.; Stonier, A.A.; Peter, G.; Sherine, A.; Praghash, K.; Ganji, V. Comprehensive Assessment of Electric Vehicle Development, Deployment, and Policy Initiatives to Reduce GHG Emissions: Opportunities and Challenges. IEEE Access 2022, 10, 53614–53639. [Google Scholar] [CrossRef]
  6. Cabello, J.R.; Bullejos, D.; Rodríguez-Prieto, A. Analytical Modelling of Arc Flash Consequences in High-Power Systems with Energy Storage for Electric Vehicle Charging. World Electr. Veh. J. 2025, 16, 425–450. [Google Scholar] [CrossRef]
  7. Shoaei, A.; Wang, Q. A Comprehensive Review of Concentric Magnetic Gears. IEEE Trans. Trans. Electr. 2024, 10, 5581–5598. [Google Scholar] [CrossRef]
  8. Li, K.; Modaresahmadi, S.; Williams, W.B.; Bird, J.Z.; Wright, J.D.; Barnett, D. Electromagnetic analysis and experimental testing of a flux focusing wind turbine magnetic gearbox. IEEE Trans. Energy Convers. 2019, 34, 1512–1521. [Google Scholar] [CrossRef]
  9. Shoaei, A.; Farshbaf-Roomi, F.; Wang, Q. Surrogate-Based Multi-Objective Optimization of Flux-Focusing Halbach Coaxial Magnetic Gear. Energies 2024, 17, 608–625. [Google Scholar] [CrossRef]
  10. Dunlap, C.; Van Neste, C.W. Magnetic Gear Wireless Power Transfer System: Prototype and Electric Vehicle Charging. Energies 2025, 18, 532–549. [Google Scholar] [CrossRef]
  11. Pop, C.V.; Fodorean, D.; Popa, D.C. Structural Analysis of an In-Wheel Motor with Integrated Magnetic Gear Designed for Automotive Applications. Sustainability 2022, 14, 12007–12029. [Google Scholar] [CrossRef]
  12. Atallah, K.; Howe, D. A Novel High-Performance Magnetic Gear. IEEE Trans. Magn. 2001, 37, 2844–2846. [Google Scholar] [CrossRef]
  13. Atallah, K.; Calverley, S.D.; Howe, D. Design, analysis and realisation of a high-performance magnetic gear. IEE Proc. Elect. Power Appl. 2004, 151, 135–143. [Google Scholar] [CrossRef]
  14. Lovato, S.; Barosco, G.; Ortombina, L.; Torchio, R.; Alotto, P.; Repetto, M.; Massaro, M. Experimental Analysis of a Coaxial Magnetic Gear Prototype. Machines 2025, 13, 716–731. [Google Scholar] [CrossRef]
  15. Halim, M.F.M.A.; Sulaiman, E.; Aziz, R.; Othman, R.N.F.K.R.; Rahman, A.A. Torque Density Design Optimization of Rotating Pole Piece Concentric Magnetic Gear. Arab. J. Sci. Eng. 2022, 47, 2797–2806. [Google Scholar] [CrossRef]
  16. Praslicka, B.; Gardner, M.C.; Johnson, M.; Toliyat, H.A. Review and Analysis of Coaxial Magnetic Gear Pole Pair Count Selection Effects. IEEE J. Power Electron. 2021, 10, 1813–1822. [Google Scholar] [CrossRef]
  17. Gardner, M.C.; Johnson, M.; Toliyat, H.A. Comparison of Surface Permanent Magnet Axial and Radial Flux Coaxial Magnetic Gears. IEEE Trans. Energy Convers. 2018, 33, 2250–2259. [Google Scholar] [CrossRef]
  18. Ji, T.K.; Baek, S.W. Optimal Design of a Coaxial Magnetic Gear Pole Combination Considering an Overhang. Appl. Sci. 2025, 15, 9625–9643. [Google Scholar] [CrossRef]
  19. Park, E.J.; Kim, Y.J. Gear Ratio Combination Analysis and Optimization for High Torque Density of Dual Magnetic Gear. J. Magn. 2024, 29, 71–76. [Google Scholar] [CrossRef]
  20. Wong, H.Y.; Baninajar, H.; Dechant, B.W.; Southwick, P.; Bird, J.Z. Experimentally Testing a Halbach Rotor Coaxial Magnetic Gear With 279 Nm/L Torque Density. IEEE Trans. Energy Convers. 2023, 38, 507–518. [Google Scholar] [CrossRef]
  21. Gardner, M.C.; Johnson, M.; Toliyat, H.A. Analysis of High Gear Ratio Capabilities for Single-Stage, Series Multistage, and Compound Differential Coaxial Magnetic Gears. IEEE Trans. Energy Convers. 2019, 34, 665–672. [Google Scholar] [CrossRef]
  22. You, Y.M. Multi-Objective Optimal Design of Permanent Magnet Synchronous Motor for Electric Vehicle Based on Deep Learning. Appl. Sci. 2020, 10, 482–496. [Google Scholar] [CrossRef]
  23. Lee, J.G.; Lim, D.K. A Stepwise Optimal Design Applied to an Interior Permanent Magnet Synchronous Motor for Electric Vehicle Traction Applications. IEEE Access 2021, 9, 115090–115099. [Google Scholar] [CrossRef]
  24. Wang, Q.; Nakashima, T.; Lai, C.; Mutsuda, H.; Kanehira, T.; Konishi, Y.; Okuizumi, H. Modified Algorithms for Fast Construction of Optimal Latin-Hypercube Design. IEEE Access 2020, 8, 191644–191658. [Google Scholar] [CrossRef]
  25. Xu, Z.; Xia, D.; Yong, N.; Wang, J.; Lin, J.; Wang, F.; Xu, S.; Ge, D. Hybrid Particle Swarm Optimization for High-Dimensional Latin Hypercube Design Problem. Appl. Sci. 2023, 13, 7066–7080. [Google Scholar] [CrossRef]
  26. Zhang, J.; Xu, J.; Jia, K.; Yin, Y.; Wang, Z. Optimal Sliced Latin Hypercube Designs with Slices of Arbitrary Run Sizes. Mathematics 2019, 7, 854–869. [Google Scholar] [CrossRef]
  27. Pholdee, N.; Bureerat, S. An efficient optimum Latin hypercube sampling technique based on sequencing optimisation using simulated annealing. Int. J. Syst. Sci. 2015, 46, 1780–1789. [Google Scholar] [CrossRef]
  28. Li, Y.; Zhang, H.; Chen, X. An Improved High-Dimensional Kriging Surrogate Modeling Method through Principal Component Dimension Reduction. Mathematics 2021, 9, 1985–2002. [Google Scholar] [CrossRef]
  29. Khan, H.A.; Khan, F.; Ahmad, N.; Ro, J. Analysis and Design of Novel High Speed Permanent Magnet Machine Considering Magnet Eddy Current Loss. IEEE Access 2020, 8, 135675–135685. [Google Scholar] [CrossRef]
  30. Ji, T.K.; Baek, S.W. Optimal Design of Coaxial Magnetic Gear according to Pole Piece Shape. J. Korea Inst. Electron. Commun. Sci. 2024, 19, 1159–1166. [Google Scholar] [CrossRef]
  31. Gündoğar, U.Y.; Zorlu Partal, S. Design, 3D FEM Simulation and Prototyping of a Permanent Magnet Spherical Motor. Actuators 2021, 10, 305–322. [Google Scholar] [CrossRef]
  32. Yin, X.; Pfister, P.D.; Fang, Y. A Novel Magnetic Gear: Toward a Higher Torque Density. IEEE Trans. Magn. 2015, 51, 1–4. [Google Scholar] [CrossRef]
  33. Kim, T.S.; Yang, J.W.; Shin, K.H.; Jang, G.H.; Han, C.; Choi, J.Y. Analysis of Electromagnetic Characteristics of Outer Rotor Type BLDC Motor Based on Analytical Method and Optimal Design Using NSGA-II. Machines 2025, 13, 440–457. [Google Scholar] [CrossRef]
  34. Tzouganakis, P.; Gakos, V.; Papalexis, C.; Kalligeros, C.; Tsolakis, A.; Spitas, V. An Analytical Thermal Model for Coaxial Magnetic Gears Considering Eddy Current Losses. Modelling 2025, 6, 114–128. [Google Scholar] [CrossRef]
  35. Rao, D.; Bagianathan, M. Selection of Optimal Magnets for Traction Motors to Prevent Demagnetization. Machines 2021, 9, 124. [Google Scholar] [CrossRef]
  36. Wu, H.-L.; Long, Z.-M.; Song, K.-Q.; Li, C.-Q.; Cong, D.-L.; Shao, B.; Liu, X.-W.; Ma, Y.-L. The Effect of Temperature Cycling on the Magnetic Degradation and Microstructure of a Zn-Coated NdFeB Magnet. Coatings 2022, 12, 660–668. [Google Scholar] [CrossRef]
  37. Mai, Q.; Hu, Q.; Chen, X. Electromagnetic–Structural Coupling Analysis and Optimization of Bridge-Connected Modulators in Coaxial Magnetic Gears. Energies 2025, 18, 2069–2095. [Google Scholar] [CrossRef]
  38. Lee, J.I.; Shin, K.H.; Bang, T.K.; Ryu, D.W.; Kim, K.H.; Hong, K. Design and Analysis of the Coaxial Magnetic Gear Considering the Electromagnetic Performance and Mechanical Stress. IEEE Trans. Appl. Supercond. 2020, 30, 3700105. [Google Scholar] [CrossRef]
  39. Lim, D.K.; Woo, D.K.; Kim, I.W.; Ro, J.S.; Jung, H.K. Cogging Torque Minimization of a Dual-Type Axial-Flux Permanent Magnet Motor Using a Novel Optimization Algorithm. IEEE Trans. Man. 2013, 49, 5106–51111. [Google Scholar] [CrossRef]
  40. Jin, R.; Chen, W.; Simpson, T. Comparative studies of metamodelling techniques under multiple modelling criteria. Struct. Multidisc. Optim. 2001, 23, 1–13. [Google Scholar] [CrossRef]
  41. Wang, C.; Qiang, X.; Xu, M.; Wu, T. Recent Advances in Surrogate Modeling Methods for Uncertainty Quantification and Propagation. Symmetry 2022, 14, 1219–1242. [Google Scholar] [CrossRef]
  42. Yan, C.; Zhu, J.; Shen, X.; Fan, J.; Mi, D.; Qian, Z. Ensemble of Regression-Type and Interpolation-Type Metamodels. Energies 2020, 13, 654–673. [Google Scholar] [CrossRef]
  43. Zhu, C.; Yang, Z.; Wang, D.; Ding, W.; Li, Z.; Wang, Y.; Wang, Q.; Du, X. A dynamic-weighted kriging-ANN hybrid model for predicting mechanical properties of grouted sands with limited data. Discov. Appl. Sci. 2025, 7, 1066. [Google Scholar] [CrossRef]
  44. Baum, M.; Anders, D.; Reinicke, T. Optimizing injection molding simulations: Comparative performance of Kriging and RSM surrogate models for process efficiency. Discov. Mech. Eng. 2025, 4, 31. [Google Scholar] [CrossRef]
  45. Yu, Y.; Pan, Y.; Chen, Q.; Hu, Y.; Gao, J.; Zhao, Z.; Niu, S.; Zhou, S. Multi-Objective Optimization Strategy for Permanent Magnet Synchronous Motor Based on Combined Surrogate Model and Optimization Algorithm. Energies 2023, 16, 1630. [Google Scholar] [CrossRef]
  46. Jeon, K.; Park, M.; Park, J.; Choi, H.; Lee, K.-D.; Lee, J.-J.; Kim, C.-W. Analysis of Cooling Characteristics of Permanent Magnet Synchronous Motor with Different Water Jacket Design Using Electromagnetic–Thermal Fluid Coupled Analysis and Design of Experiment. Machines 2023, 11, 903. [Google Scholar] [CrossRef]
  47. Chao, T.; Fu, H.; Wang, Z.; Zhang, Z.; Qian, W.; Zhang, H.; Xu, S.; Cao, S.; He, D. Deformable surface design of vertical graphene thermal interface materials for efficient heat dissipation. Cell Rep. Phys. Sci. 2024, 5, 101978. [Google Scholar] [CrossRef]
  48. Sarkar, D.; Naskar, A.K. Computation of thermal condition in an induction motor during reactor starting. Inter. J. Electr. Power Energy Syst. 2013, 44, 938. [Google Scholar] [CrossRef]
  49. Szulborski, M.; Łapczyński, S.; Kolimas, Ł.; Zalewski, D. Transient Thermal Analysis of the Circuit Breaker Current Path with the Use of FEA Simulation. Energies 2021, 14, 2359. [Google Scholar] [CrossRef]
  50. Kleilat, I.; Benkara, K.E.K.; Friedrich, G.; Vivier, S.; Moubayed, N.; Dib, R. Comparison of Two Analytical Methods for Calculating the Maximum Mechanical Stress in the Rotor of High-Speed-Assisted Synchronous Reluctance Machines. IEEE Trans. Ind. Appl. 2021, 57, 1344–1353. [Google Scholar] [CrossRef]
  51. Hu, F.; Zhou, Y.; Cui, H.; Liu, X. Spectrum Analysis and Optimization of the Axial Magnetic Gear with Halbach Permanent Magnet Arrays. Energies 2019, 12, 2003. [Google Scholar] [CrossRef]
Figure 1. Structure of the initial CMG model.
Figure 1. Structure of the initial CMG model.
Actuators 15 00059 g001
Figure 2. CMG models for each pole-pair combination: (a) 1:10.2, (b) 1:10.4, (c) 1:10.5, and (d) 1:10.66.
Figure 2. CMG models for each pole-pair combination: (a) 1:10.2, (b) 1:10.4, (c) 1:10.5, and (d) 1:10.66.
Actuators 15 00059 g002
Figure 3. Optimal design process.
Figure 3. Optimal design process.
Actuators 15 00059 g003
Figure 4. Design variables of the CMG.
Figure 4. Design variables of the CMG.
Actuators 15 00059 g004
Figure 5. Result of design sensitivity analysis: (a) 1:10.2; (b) 1:10.4; (c) 1:10.5; (d) 1:10.66.
Figure 5. Result of design sensitivity analysis: (a) 1:10.2; (b) 1:10.4; (c) 1:10.5; (d) 1:10.66.
Actuators 15 00059 g005
Figure 6. Convergence profile of design variables: (a) 1:10.2; (b) 1:10.4; (c) 1:10.5; (d) 1:10.66.
Figure 6. Convergence profile of design variables: (a) 1:10.2; (b) 1:10.4; (c) 1:10.5; (d) 1:10.66.
Actuators 15 00059 g006
Figure 7. Magnetic flux density distribution of the initial CMG model: (a) isometric view; (b) top view; (c) front view.
Figure 7. Magnetic flux density distribution of the initial CMG model: (a) isometric view; (b) top view; (c) front view.
Actuators 15 00059 g007
Figure 8. Magnetic flux density distribution of the optimally designed CMG model: (a) isometric view; (b) top view; (c) front view.
Figure 8. Magnetic flux density distribution of the optimally designed CMG model: (a) isometric view; (b) top view; (c) front view.
Actuators 15 00059 g008
Figure 9. Comparison of torque characteristics between the initial and optimized CMG models.
Figure 9. Comparison of torque characteristics between the initial and optimized CMG models.
Actuators 15 00059 g009
Figure 10. Harmonic analysis of the air-gap magnetic flux density: (a) time-domain waveforms; (b) FFT analysis.
Figure 10. Harmonic analysis of the air-gap magnetic flux density: (a) time-domain waveforms; (b) FFT analysis.
Actuators 15 00059 g010
Figure 11. Geometries of the CMG models used for electromagnetic–thermal coupled analysis: (a) initial model, isometric view; (b) initial model, front view; (c) optimized model, isometric view; (d) optimized model, front view.
Figure 11. Geometries of the CMG models used for electromagnetic–thermal coupled analysis: (a) initial model, isometric view; (b) initial model, front view; (c) optimized model, isometric view; (d) optimized model, front view.
Actuators 15 00059 g011
Figure 12. Transient temperature distribution of the initial CMG model at t = 600 s (10 min): (a) front view; (b) front view without CMG geometry; (c) isometric view.
Figure 12. Transient temperature distribution of the initial CMG model at t = 600 s (10 min): (a) front view; (b) front view without CMG geometry; (c) isometric view.
Actuators 15 00059 g012
Figure 13. Transient temperature distribution of the optimized CMG model at t = 600 s (10 min): (a) front view; (b) front view without CMG geometry; (c) isometric view.
Figure 13. Transient temperature distribution of the optimized CMG model at t = 600 s (10 min): (a) front view; (b) front view without CMG geometry; (c) isometric view.
Actuators 15 00059 g013
Figure 14. Transient evolution of the maximum temperature rise over a 10 min simulation interval for the initial and optimized CMG models.
Figure 14. Transient evolution of the maximum temperature rise over a 10 min simulation interval for the initial and optimized CMG models.
Actuators 15 00059 g014
Figure 15. Demagnetization characteristics based on the demagnetization coefficient (at a 150 °C thermal condition).
Figure 15. Demagnetization characteristics based on the demagnetization coefficient (at a 150 °C thermal condition).
Actuators 15 00059 g015
Figure 16. Von Mises stress distribution of the CMG in the permanent magnet region.
Figure 16. Von Mises stress distribution of the CMG in the permanent magnet region.
Actuators 15 00059 g016
Figure 17. Von Mises stress distribution of the CMG in the ferromagnetic core region.
Figure 17. Von Mises stress distribution of the CMG in the ferromagnetic core region.
Actuators 15 00059 g017
Table 1. Dimensions and specifications of the CMG.
Table 1. Dimensions and specifications of the CMG.
ParameterValueUnit
Outer radius of Rotor 143.5mm
Outer radius of Rotor 253.6mm
Outer radius of Rotor 390mm
Inner radius12.5mm
Axial length40mm
Air gap1mm
Overhang length11.1mm
Pole piece length8.6mm
Input speed (Rotor 1)1000rpm
Permanent magnet materialN35UH-
Core material20JNEH1500-
Table 2. Pole-pair combinations and corresponding gear ratios.
Table 2. Pole-pair combinations and corresponding gear ratios.
P1Q2P3Gear Ratio
551461:10.2
552471:10.4
442381:10.5
332291 10.66
Table 3. Initial analysis results obtained from 3D FEM simulations.
Table 3. Initial analysis results obtained from 3D FEM simulations.
Gear RatioAverage Torque [Nm]Volume [mm3]Torque Density [Nm/L]
10.228.49929,487.2930.65
10.449.98915,086.0354.62
10.536.03945,059.6738.13
10.6642.16944,869.8744.62
Table 4. Range of design variables.
Table 4. Range of design variables.
ParameterInitialMinimumMaximumUnit
X111.1030mm
X28.6412mm
X3164100180degree
X4156100180degree
X5174100180degree
X6907090mm
X710.51mm
X825.341733.5mm
Table 5. Initial performance comparison of the four CMG models based on 3D FEM.
Table 5. Initial performance comparison of the four CMG models based on 3D FEM.
Gear RatioAverage Torque [Nm]Torque Density [Nm/L]
10.230.83736.117
10.431.77137.360
10.537.78344.459
10.6642.23172.531
Table 6. Metamodel performance evaluation (RMSE).
Table 6. Metamodel performance evaluation (RMSE).
Gear RatioAverage Torque [Nm]Torque Ripple [Nm]Volume [mm3]
10.2KRG (0.78)MLP (0.41)PRG (137.87)
PRG (0.97)EDT (0.42)KRG (1896.61)
RBF (1.21)KRG (0.47)RBF (7912.29)
MLP (1.51)PRG (0.48)EDT (13,043.16)
EDT (1.59)RBF (0.53)MLP (108,940.08)
10.4KRG (0.70)MLP (0.45)PRG (137.87)
PRG (0.89)EDT (0.47)KRG (1896.61)
RBF (1.02)KRG (0.48)RBF (7912.29)
MLP (1.68)PRG (0.52)EDT (13,043.16)
EDT (1.83)RBF (0.56)MLP (108,940.08)
10.5PRG (0.73)MLP (0.43)PRG (137.87)
KRG (0.82)KRG (0.46)KRG (1896.61)
RBF (1.06)PRG (0.47)RBF (7912.29)
MLP (1.84)EDT (0.48)EDT (13,043.16)
EDT (2.18)RBF (0.51)MLP (108,940.08)
10.66KRG (1.04)MLP (0.48)PRG (137.86)
PRG (1.17)EDT (0.60)KRG (1896.61)
RBF (1.69)KRG (0.62)RBF (7912.29)
MLP (2.46)PRG (0.66)EDT (11,701.29)
EDT (2.74)RBF (0.95)MLP (95,900.16)
Table 7. Result of design optimization.
Table 7. Result of design optimization.
Gear RatioX1 [mm]X2 [mm]X3 [degree]X4 [degree]X5 [degree]X6 [mm]X7 [mm]X8 [mm]
10.225.17.312171135120700.5320.61
10.4257.937170135120700.53120.8
10.53012180100177700.533.5
10.6626.111.413170123100700.55420.57
Table 8. Validation results of torque characteristics obtained from 3D FEM.
Table 8. Validation results of torque characteristics obtained from 3D FEM.
Gear RatioAverage Torque [Nm]Ripple Factor [%]Torque Density [Nm/L]
10.245.855.5578.59
10.449.128.4581.11
10.560.247.48102.29
10.6665.754.57117.14
Table 9. Torque comparison of the CMG models with cap and housing based on 3D FEM.
Table 9. Torque comparison of the CMG models with cap and housing based on 3D FEM.
ModelAverage Torque [Nm]Ripple Factor [%]
Initial21.868.33
Optimal66.065.35
Table 10. Comparison with previous optimization studies.
Table 10. Comparison with previous optimization studies.
ModelInitial Torque Density [Nm/L]Optimal Torque Density [Nm/L]Improvement
[%]
Proposed Model44.62117.14162.51
[9] Coaxial326.541125.88
[51] Axial78.193.319
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Ji, T.-K.; Baek, S.-W. Optimal Design of a Coaxial Magnetic Gear Considering Thermal Demagnetization and Structural Robustness for Torque Density Enhancement. Actuators 2026, 15, 59. https://doi.org/10.3390/act15010059

AMA Style

Ji T-K, Baek S-W. Optimal Design of a Coaxial Magnetic Gear Considering Thermal Demagnetization and Structural Robustness for Torque Density Enhancement. Actuators. 2026; 15(1):59. https://doi.org/10.3390/act15010059

Chicago/Turabian Style

Ji, Tae-Kyu, and Soo-Whang Baek. 2026. "Optimal Design of a Coaxial Magnetic Gear Considering Thermal Demagnetization and Structural Robustness for Torque Density Enhancement" Actuators 15, no. 1: 59. https://doi.org/10.3390/act15010059

APA Style

Ji, T.-K., & Baek, S.-W. (2026). Optimal Design of a Coaxial Magnetic Gear Considering Thermal Demagnetization and Structural Robustness for Torque Density Enhancement. Actuators, 15(1), 59. https://doi.org/10.3390/act15010059

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.