Bacterial Contaminants in Ambulances from a Tertiary Care Hospital as Potential Threats to Patients and Medical Staff in Al-Qassim Region, Saudi Arabia—Effect of Decontamination

1
Microbiology and Immunology Unit, Department of Pathology, College of Medicine, Jouf University, Sakaka City 72388, Aljouf, Saudi Arabia
2
Department of Medical Microbiology and Immunology, Faculty of Medicine, Mansoura University, Mansoura City 35516, Aldakahlia Governorate, Egypt
3
Radiology Department, Alqwarah General Hospital, Ministry of Health (MOH), Buraydah City 51452, Alqassim, Saudi Arabia
4
Infection Prevention and Control, College of Medicine, Jouf University, Sakaka City 72388, Aljouf, Saudi Arabia
5
Emergency Medical Services Department, Alqwarah General Hospital, Ministry of Health (MOH), Buraydah City 51452, Alqassim, Saudi Arabia
6
Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah City 51452, Alqassim, Saudi Arabia
7
Administration of Forensic Toxicology Services, Forensic Medical Services Center, Ministry of Health (MOH), Buraydah City 51452, Alqassim, Saudi Arabia
8
Infection Control Directorate at the Public Health Authority Office, Ministry of Health (MOH), Buraydah City 51452, Alqassim, Saudi Arabia
*
Author to whom correspondence should be addressed.
Pathogens 2025, 14(12), 1301; https://doi.org/10.3390/pathogens14121301
Submission received: 18 November 2025 / Revised: 10 December 2025 / Accepted: 16 December 2025 / Published: 18 December 2025

Abstract

Bacterial contaminants in ambulances could have a major impact on morbidities, mortalities, and healthcare resources, especially if these bacteria are antimicrobial-resistant. As far as we know, this is the first study in Al-Qassim region to evaluate the prevalence of bacterial contaminants in swab samples obtained from ambulances from Alqwarah General Hospital, Al-Qassim region, Saudi Arabia as an indicator for evaluation of the implemented infection control measures, and screen the antibiotics profiles of the isolates against the most regularly used antimicrobials. In total, 204 samples were collected from the ambulances following patient transport. To evaluate the effect of vehicle decontamination, 204 swabs were collected from the same sites of the ambulances immediately after cleaning and disinfection. The isolates were identified using standard bacteriological and biochemical methods, as recommended by the Clinical Laboratory Standard Institute (CLSI). The antibiotic susceptibility patterns were assessed using the Kirby–Bauer disc diffusion method. The prevalence of bacterial contamination in the samples collected following patient transport was 46.08%. In total, 83.33%, 75.00%, and 66.66% of the samples collected from DC shock apparatuses, ceilings, and emergency personnel seats, respectively, were contaminated. Furthermore, ceilings, DC shock apparatuses, emergency personnel seats, cervical collars, and monitors were found to harbor 10.8%, 9.8%, 7.8%, 6.8%, and 6.8% of the 102 bacterial isolates, respectively. Gram-positive organisms represented 96.1% of all bacterial isolates. Bacillus spp. was the most common isolate, accounting for 60.8% of all bacterial isolates. Although Pseudomonas aeruginosa and Proteus spp. isolates were sensitive to all the tested antimicrobials, many Gram-positive bacterial isolates were resistant to some antibiotics in variable frequencies. After 48 h of aerobic incubation (with or without 5–10% CO2) on nutrient, blood, chocolate, and MacConkey agar plates at 37 °C, no bacterial growth was detected in the samples collected immediately following cleaning and disinfection. This is the second Saudi study to evaluate the prevalence of bacterial contaminants in Saudi Arabian ambulances, and it could help health policy makers in improving the implemented infection prevention and control measures in Saudi Arabian ambulances. The samples taken after patient transport revealed bacterial contaminants with varying rates of antimicrobial resistance. Policies ensuring the optimal cleaning and disinfection of ambulances can minimize the potential of bacterial infection for high-risk patients, their relatives, and healthcare providers.

1. Introduction

The ambulances utilized by emergency medical care teams are workplaces for qualified medical and paramedical staff who oversee daily transportation for patients in life-threatening conditions from all walks of life with a variety of infections, diseases, and injuries. Millions of seriously ill and injured patients are transported to and from hospitals and other healthcare (HC) facilities by emergency medical services (EMS) personnel, who are frequently referred to as the “front lines” of the HC system. EMS providers frequently encounter a wide range of hazardous and erratic circumstances while carrying out their jobs, endangering both their own and their patients’ safety. EMS personnel are up to seven times more likely to suffer harm at work [1].
Numerous surfaces, including the patient-care compartments of ambulances, around the world have been found to harbor the organisms most frequently linked to healthcare-associated infections (HAIs). The complexity of addressing the accompanying infections makes organisms detected in ambulance environments problematic, especially if they are of a multidrug resistant (MDR) nature. Emergency care frequently involves people in life-threatening situations. When using ambulance services, vulnerable groups such as the old, young, immunocompromised, and seriously injured are frequently treated concurrently. Therefore, transport vehicles may be potential sources of transmission of microbes to high-risk patients, their relatives, and HC providers [2]. By encountering infected patients and their body fluids, as well as by visiting a variety of locations throughout their shifts (such as homes, workplaces, and hospitals), EMS providers are probably regularly exposed to biohazard threats from microorganisms [3].
According to the World Health Organization (WHO), millions of HAIs occur annually, affecting around 7% and up to 19% of patients in developed and developing countries, respectively [4]. According to the American Centers for Disease Control and Prevention (CDC), many bacteria, viruses, and/or fungi can cause HAIs, but special attention has been paid to the organisms that are highly contagious, exhibit high virulence, or are resistant to common antimicrobials. MDR bacteria are of particular concern because they can cause serious and challenging-to-treat HAIs [5]. Bacterial contaminants in ambulances could have a major impact on morbidities, mortalities, and HC resources, especially if these bacteria are MDR. Thus, ambulances may pose a risk of serious infection to patients, their relatives, HC providers, and paramedics [2,3].
Bacterial contamination of ambulances has been the subject of numerous studies worldwide [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25]. Bacillus species (spp.) have been reported in many countries, including the UK [6], the USA [7], Saudi Arabia [14], and Spain [19]. In the UK, micrococci have been detected among ambulances’ bacterial contaminants [6]. In the UK [6], the USA [7], South Korea [10,12], Iraq [13], Spain [19], Denmark [20], Egypt [21], Iran [23], and India [24], Gram-negative bacterial contaminants have been isolated. Staphylococci were detected in UK [6], USA [7,8,11,22], Germany [9,16], South Korea [10,12], Saudi Arabia [14], Thailand [15], Australia [17], Denmark [18,20], Spain [19], Egypt [21], Iran [23], India [24], and Poland [25].
The family Firmicutes contains the genus Bacillus, which is composed of aerobic, facultative anaerobic, Gram-positive spore-forming bacilli with low GC content. The amount of vegetation, mean annual temperature, soil moisture content, and pH all have an impact on the abundance of Bacillus spores in the soil. Numerous pathogenic and non-pathogenic Bacillus spp. are frequently found in soil [26]. Micrococci are spherical, Gram-positive, coagulase-negative, catalase-positive cocci that are frequently seen in tetrads and are members of the Micrococcaceae family. Micrococcus species are frequently found in the environment and can cause opportunistic infections in people with impaired immune systems [27]. Moraxella is an aerobic, oxidase-positive, Gram-negative diplococcus that is often considered a potentially pathogenic genus, particularly in immunocompromised people [28]. The prevalence of bacteria, including staphylococci, in ambulances highlights the importance of maintaining high hygiene and decontamination standards during regular prehospital work with patients [6].
Infection or colonization with MDR organisms found in ambulances increases the probability of complications. Given the frequency of organisms often linked to HAIs in the patient-care compartments of ambulances, it is obvious that the best decontamination compliance procedures are not always followed [2]. The contribution of EMS vehicles and equipment to the epidemiological transmission of HAIs both inside and outside the HC industry requires further research. As far as we are aware, there is just one study looking at the bacterial contamination of Saudi Arabian ambulances [14]. In this prospective, our study aims were to determine the prevalence of bacterial contaminants in the ambulances used at Alqwarah General Hospital in the Al-Qassim region of Saudi Arabia and to assess the isolates’ antibiotic profiles against the most-used antimicrobials as indicators for evaluating the effectiveness of the infection control strategies that were put in place.

2. Materials and Methods

2.1. Design of the Study

Bioethical approval (no. 607-46-010690) was obtained from the Qassim Region Research Ethics Committee (QREC; No. H-04-Q-001), Qassim, Saudi Arabia. According to the inclusion criteria, we included ambulances that were regularly used for transfer of patients, ambulances whose drivers were unaware of when sampling visits would be conducted, and ambulances whose drivers agreed to cooperate. We excluded ambulances that were out of service, ambulances whose drivers previously knew when sampling visits would be conducted, and ambulances whose driver refused to cooperate.
Swab samples were collected from different sites of two ambulances at Alqwarah General Hospital, Al-Qassim region, Saudi Arabia, in a cross-sectional study during April and May 2025. The privacy and confidentiality of those responsible for the ambulances were protected. Processing of the samples was performed in the microbiology laboratory of the Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah City 51452, Saudi Arabia, after obtaining the required permissions.

2.2. Collection and Transport of Samples

The required sample size for each of the two ambulances was estimated using the following formula: n = (Z2 × p(1 − p))/d2, where n = sample size, Z = Z-score corresponding to the desired confidence level (Z = 1.96 when confidence level = 95%), p = the estimated proportion of contamination (a conservative estimate was used: p = 0.5), and d = desired margin of error (we used a margin of error of 0.1) [29]. Thus, the estimated sample size for each ambulance was 96 swabs. In total, 204 samples were collected from different sites of two ambulances following patient transport (17 swabs were collected from each ambulance in six sampling visits).
We used sterile cotton-tipped swabs with amies transport media (GlobalRoll®, Hangzhou, China). The sampling sites were as follows: carrying handle of cart, sidebar of cart, DC shock apparatus, stethoscope, cervical collar, inside wall of vehicle, emergency personnel seats, portable ventilator, blood pressure cuff, monitor, door grip, oxygen humidifier glass, suction device, headboard of patient stretcher, and steering wheel. The sterile swabs, which had been moistened with the transport media, were rolled over all the selected surfaces.
To evaluate the effect of vehicle decontamination, 204 swabs were collected from the same sites of the ambulances immediately after cleaning and disinfection. Standard bleach (sodium hypochlorite solution, 10,000 parts per million; normal dilution, 1:10) was the main disinfectant that was used, especially for blood spills and external surfaces. Alcohol (70–95%) was used for external surfaces of certain pieces of equipment, including stethoscopes and pulse oximeters. For walls, floors, and furnishings, quaternary ammonium compounds or hydrogen peroxide was used.
Each sample was collected in a sterile bag and carried in an icebox to be processed according to the standard microbiological methods in the microbiology laboratory of the Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University after the required permissions were obtained.

2.3. Isolation and Identification of Bacteria

To avoid contamination, the samples were handled aseptically upon arrival. All media used in this study were prepared according to the manufacturer’s guidelines. The swabs were placed in tubes containing five milliliters of double-strength brain–heart infusion broth (Oxoid, Hampshire, UK) and incubated (with or without 5–10% CO2) aerobically at 37 °C for 24 h. After enrichment, the swabs were cultured on nutrient, blood, chocolate, and MacConkey agar plates (Oxoid, Hampshire, UK) and incubated (with or without 5–10% CO2) aerobically at 37 °C for an additional 48 h. To isolate pure single colonies of each bacterial isolate, the colonies were further subcultured on these agar plates under the same conditions for another 24 h. Following this, the pure colonies were analyzed using standard microbiological techniques, which included examining colony morphology (size, color, and shape), performing Gram staining, and conducting biochemical tests [30].

2.4. Antibiotic Sensitivity Testing

The antibiotic susceptibilities patterns of the bacterial isolates were assessed via the Kirby–Bauer disc diffusion method according to the guidelines of the clinical and laboratory standards institute (CLSI) [31]. The Gram-positive bacterial isolates were tested against the following antimicrobials: AP—Ampicillin, 10 μg; AK—Amikacin, 30 μg; AUG—Augmentin, 30 μg; BA—Bacitracin, 10 U; C—Chloramphenicol, 30 μg; CAZ—Ceftazidime, 30 μg; CIP—Ciprofloxacin, 5 μg; CD—Clindamycin, 2 μg; CPM—Cefepime, 30 μg; E—Erythromycin, 15 μg; FOX—Cefoxitin, 30 μg; GM—Gentamicin, 10 μg; Imipenem, 10 μg; KF—Cephalothin, 30 μg; NE—Neomycin, 30 μg; OT—Oxytetracycline, 30 μg; OX—Oxacillin, 5 μg; PG—Penicillin G, 10 U; PRL—Piperacillin, 30 μg; T—Tetracycline, 30 μg; TS—Cotrimoxazole, 25 μg; and VA—Vancomycin, 30 μg. The Gram-negative bacterial isolates were tested against the following antimicrobials: AP—Ampicillin, 10 μg; AK—Amikacin, 30 μg; ATM—Aztreonam, 30 μg; AUG—Augmentin, 30 μg; C—Chloramphenicol, 30 μg; CAZ—Ceftazidime, 30 μg; CIP—Ciprofloxacin, 5 μg; CPM—Cefepime, 30 μg; FOX—Cefoxitin, 30 μg; GM—Gentamicin, 10 μg; Imipenem, 10 μg; KF—Cephalothin, 30 μg; NE—Neomycin, 30 μg; PRL—Piperacillin, 30 μg; PB—Polymyxin B, 300 U; and TS—Cotrimoxazole, 25 μg.

2.5. Quality Control (QC)

ATCC strains (Staphylococcus aureus; ATCC25923 as QC for Gram-positive isolates; and Escherichia coli ATCC10536 as QC for Gram-negative isolates) were used as positive controls. QC testing was carried out in triplicate. Each isolate was tested in triplicate. The study’s negative controls for bacterial culture were non-inoculated nutrient, blood, chocolate, and MacConkey agar plates incubated (with or without 5–10% CO2) aerobically at 37 °C for 48 h. All data were evaluated using CLSI’s guidelines [31].

2.6. Data Analysis

Categorical data was presented as numbers and percentages. The total bacterial contamination prevalence rate was determined from the number of growth-positive swabs at the time the study was conducted divided by the number of all collected swabs. Each sampling site’s bacterial contamination prevalence was tested statistically by using the Chi-square (X2) test to compare the likelihood of an event (bacterial contamination) occurring between two groups (growth-positive/growth-negative swabs). Alternatively, the Fisher Exact (FE) correction test was applied when more than 20% of the cells had an expected count of less than 5. Statistical significance was considered at p ≤ 0.05.

3. Results

During the study, different samples were collected from the ambulances used by Alqwarah General Hospital, Al-Qassim region, Saudi Arabia. A total of 204 samples were collected following patient transport. Under suitable incubation conditions, samples were processed and grown on suitable media. Bacterial contaminants were detected (94 bacterial-growth-positive swabs/204 samples collected from the ambulances after the patients had been transported—46.08%). Out of the 94 swabs with positive bacterial growth, 86 samples revealed a single pathogen, while 8 samples revealed two pathogens. As a result, the overall count of bacterial isolates was 102.
The frequency of positive bacterial growth from each site of each vehicle is presented in Table 1. It is clear that 83.33%, 75.00%, and 66.66% of the samples collected from DC shock apparatuses, ceilings, and emergency personnel seats, respectively, were contaminated. Statistically, it is clear that the DC shock apparatuses and ceilings have a greater probability of being contaminated (p ≤ 0.05). Furthermore, the frequency of bacterial isolates in each site of each ambulance is presented in Table 2. In total, 10.8%, 9.8%, 7.8%, 6.8%, and 6.8% of the bacterial isolates were recovered from the ceilings of the ambulances, DC shock apparatuses, emergency personnel seats, cervical collars, and monitors, respectively.
The distribution of bacterial isolates on each site in the ambulances is presented in Table 3. It is clear that Gram-positive organisms represent 96.1% of all the bacterial isolates (98 Gram-positive/102 total isolates). Bacillus spp. was the most common isolate, accounting for 60.8% of all the bacterial isolates (62 Bacillus spp./102 total isolates), followed by Micrococcus spp., which represented 30.4% of the total bacterial isolates. The Gram-negative isolates only represented 3.9% of the total bacterial isolates.
Regarding the antimicrobial resistance patterns of the Gram-positive bacterial isolates, variable frequencies of resistance to some antibiotics were detected, as presented in Table 4. The control strain S. aureus ATCC25923 was susceptible to the tested antimicrobial. The Gram-negative bacterial isolates were tested against many antimicrobials. Fifty percent of the Moraxella isolates were resistant to cotrimoxazole and cephalothin antimicrobials. The isolates of Moraxella were susceptible to the remaining antibiotics, while the Pseudomonas aeruginosa and Proteus spp. isolates were sensitive to all the tested antibiotics. The control strain, E. coli ATCC10536, was susceptible to the tested antimicrobials.
Concerning the samples collected from the ambulances immediately following cleaning and disinfection, no bacterial growth was detected after 48 h of aerobic incubation (with or without 5–10% CO2) on nutrient, blood, chocolate, or MacConkey agar plates blood agar plates at 37 °C.

4. Discussion

Bacterial contaminants found in ambulances must be further isolated and characterized to be properly prevented and controlled. In this prospective study, we aimed to determine the prevalence of bacterial contaminants in swab samples obtained from ambulances used by Alqwarah General Hospital, Al-Qassim region, Saudi Arabia as an indicator for evaluating the implemented infection prevention and control measures, and screen the isolates’ antibiotics profiles for the most regularly used antimicrobials. The bacterial contamination prevalence in the samples collected following patient transport was 46.08%. The ambulances’ ceilings, DC shock apparatuses, and emergency personnel seats were the most common sites for bacterial contaminant detection.
Variable bacterial contamination rates have been reported in many countries, including the United Kingdom, the USA, Germany, South Korea, Iraq, Saudi Arabia, Thailand, Australia, Denmark, Spain, Egypt, Iran, India, and Poland [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25], with great variability in isolate types, and the highly contaminated sites are presented in Appendix A Table A1. To our knowledge, only one prior Saudi study has examined bacterial contamination in ambulances in Saudi Arabia. This research was carried out at the EMS Department of Prince Sultan Bin Abdulaziz College of EMS at King Saud University in Riyadh, Saudi Arabia, in October and November 2013, involving a total of 10 ambulances. The study reported a 90.00% total ambulance bacterial contamination rate (100%, 90%, and 80% contamination rates of the interior handle of the rear door, oxygen knobs, and stretcher handles, respectively) [14].
It was evident from the distribution of bacterial isolates on each ambulance site in our study that 96.1% of all the bacterial isolates were Gram-positive species. Accounting for 60.8% of all bacterial isolates, Bacillus spp. were the most prevalent, followed by Micrococcus spp., which accounted for 30.4% of all the bacterial isolates. Only 3.9% of the detected total bacterial contaminants were Gram-negative isolates. Although Pseudomonas aeruginosa and Proteus spp. isolates were sensitive to all the antimicrobials tested, many Gram-positive bacterial isolates were resistant to some antibiotics at variable frequencies. In line with our study, great variabilities in the bacterial contaminants of ambulances and their sensitivity/resistance to antimicrobials reported were in [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25], as presented in Appendix A Table A1. The predominance of Gram-positive bacterial isolates was clear in a previous Saudi Arabian study in which Bacillus spp. and coagulase negative staphylococci were the top two detected bacterial contaminants [14]. Bacillus spp. can be transmitted via air currents, especially during hot, dry summer months [32], as in many Saudi regions. Bacillus spp. have been reported in other countries too, including the UK [6], the USA [7], and Spain [19].
To assess safety, microbiological standards that include the presence of indicator organisms can be implemented. Identifying these organisms helps determine potential risks to human health in HC settings. Staphylococcus aureus can be considered a reliable indicator of environmental hygiene [33]. While Staphylococcus aureus was not detected among the isolates in our study, it has been detected in the UK [6], the USA [8,11,22], Germany [9,16], South Korea [10,12], Thailand [15], Australia [17], Denmark [18,20], Spain [19], Egypt [21], India [24], and Poland [25].
The variability in the contamination rates of ambulances, their highly contaminated sites, and the types of bacterial isolates can be attributed to several factors, including the nature of emergency calls (for example, a trauma call may introduce more pathogens than non-emergency calls), patient demographics (including age and health status, as some people may carry higher bacterial loads), variations in decontamination practices (cleaning and disinfection protocols, equipment, and frequency of decontamination), and environmental conditions. Environmental factors such as urban density, pollution levels, and environmental temperature can influence the bacterial load present on surfaces. While it is conceivable that the intense heat typical of Saudi Arabia’s environment could serve as a defense against certain infections, it was clearly demonstrated in both our study and the earlier Saudi research that Bacillus spp. can resist hot atmospheres. The different types of materials utilized in an ambulance’s interior, which may retain bacteria to variable degrees, can also have an impact on contamination levels, as can seasonal bacterial fluctuations and high passenger turnover. These discrepancies are further exacerbated by the infrastructure of HC facilities in particular regions and the existence of microbial resistance, underscoring the necessity of using focused approaches to enhance the EMS’ infection prevention and control regulations.
The bacteria associated with HAIs possess two notable characteristics. They not only cause illness but also can persist in hospital environments for weeks. It is essential to ensure that pathogens are not present on surfaces in HC settings to maintain safety for both patients and HC workers. Important bacteria to steer clear of in these environments include Methicillin-resistant Staphylococcus aureus (MRSA), Vancomycin-resistant Enterococci (VRE), Clostridium difficile, and Acinetobacter. While Gram-negative coliforms, such as E. coli and Klebsiella spp., are not as resilient, they can survive on both dry and wet surfaces, albeit for shorter durations compared to the more durable Acinetobacter and Gram-positive bacteria mentioned earlier [32].
The results of our study show that no bacterial growth was detected in the samples taken from the ambulances immediately after they were cleaned and disinfected, suggesting that efficient infection prevention and control measures were implemented. Alqwarah General Hospital in Al-Qassim region, Saudi Arabia, implements the EMS infection control guidelines of the Saudi Ministry of health [34]. Briefly, these infection prevention and control guidelines include patient transfer recommendations; immunization programs; tuberculosis screening guidelines for EMS providers; an EMS provider fitness test and basic infection control skills license (BICSL); a patient isolation guide for EMS transport; standard precautions; hand hygiene; personal protective equipment (PPE), cleaning and disinfection for vehicle equipment, patient contact surfaces, and ambulance surfaces, as presented in Table 5 and Table 6; continuous availability of supplies; and education, training, compliance, and monitoring for EMS providers. Furthermore, the infection control practices are audited using a checklist for the cleaning and disinfection of the ambulances.
Aerobic colony counts of less than 2.5 to 5 colony-forming units per cm2 on surfaces frequently touched by hands are recognized as microbiological standards for surfaces inside hospitals [35]. Although achieving a completely sterile environment is unrealistic, the objective is to reduce the number of harmful microorganisms on ambulance surfaces to safeguard patients and HC providers. It is essential to set an appropriate benchmark for regular microbiological monitoring of surface cleanliness in ambulances. Once these benchmarks are in place, ongoing microbiological monitoring can reveal trends in ambulance cleanliness and workload and, most importantly, signal when additional cleaning is necessary to prevent potential infections. Adhering to best practices for cleaning and disinfecting EMS vehicles and patient care equipment is crucial for controlling the spread of infections.
Among the limitations of our study were the small sample size (204 swabs) and the fact that the swab samples were only collected from a single medical center. Furthermore, we did not evaluate seasonal bacterial fluctuations. Nonetheless, we focused on a crucial issue and think we have enough data to achieve our goal and support our findings. Despite these limitations, our work emphasizes the necessity of further investigation into the bacteria that frequently result in HAIs via ambulance environments.

5. Conclusions and Recommendations

To the best of our knowledge, this is the second Saudi study to evaluate the prevalence of bacterial contaminants in swab samples obtained from Saudi Arabian ambulances, and it could help health policy makers in improving the infection prevention control measures implemented in Saudi Arabian ambulances. The swab samples collected from the ambulances after the patients were transported revealed bacterial contaminants with varying degrees of reduced antimicrobial susceptibility. Ambulance environments can be sources of HAIs. No bacterial contaminants were detected after proper cleaning and disinfection. Optimal infection control measures, including effective policies for cleaning and disinfecting ambulances, can minimize the potential of bacterial infection for high-risk patients, their relatives, and HC providers. Our study underscores the need for more widespread and in-depth studies of the ambulance microbiome as an important pathogen reservoir for HAIs. It is essential to establish a suitable benchmark for routine microbiological surveillance of ambulance surface safety.

Author Contributions

Conceptualization, A.E.T.; data curation, A.E.T., A.R.A. and A.M.K.; formal analysis, A.E.T., A.R.A. and A.M.K.; investigation, A.E.T., A.R.A. and A.M.K.; methodology, A.E.T.; project administration A.E.T.; resources, A.E.T., A.R.A., O.N.A., A.M.K., A.A., S.A., A.N.A., M.A., K.A. and F.M.A.; software, A.E.T., A.R.A., O.N.A., A.M.K., A.A., S.A., A.N.A., M.A., K.A. and F.M.A.; supervision, A.E.T.; validation, A.E.T., A.R.A. and A.M.K.; visualization, A.E.T., A.R.A., O.N.A., A.M.K., A.A., S.A., A.N.A., M.A., K.A. and F.M.A.; writing—original draft, A.E.T. and A.R.A.; writing—review and editing, A.E.T. All authors have read and agreed to the published version of the manuscript.

Funding

The authors declare that they did not receive any financial support for this research.

Institutional Review Board Statement

The study was conducted in accordance with the Decla-ration of Helsinki and approved by the Qassim Region Research Ethics Committee (QREC; No. H-04-Q-001), Qassim, Saudi Arabia (Bioethical approval no. 607-46-010690, approved on 12 March 2025).

Informed Consent Statement

Written informed consent was obtained from the supervisors of the ambulances used in the study. All data were anonymized to ensure confidentiality.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding authors.

Acknowledgments

We are very thankful for the administration of Alqwarah General Hospital, Ministry of Health, Alqassim province, Buraydah City 51452, Saudi Arabia, for facilitating the work of the research team during sample collection. We appreciate the support of the administration of the Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah City 51452, Saudi Arabia, during our use of their microbiology facilities.

Conflicts of Interest

The authors declare that there are no conflicts of interest.

Appendix A

Table A1. Previous studies reporting bacterial contamination in ambulances.
Table A1. Previous studies reporting bacterial contamination in ambulances.
CountryPublication YearCollection of SamplesDetected Organism(s)Contamination FrequencyReported Highly Contaminated SurfacesReference No.
UK200312 ambulances
(7 surfaces).
Bacillus sp., coliforms, Micrococcus sp., Corynebacterium sp., Pseudomonas sp., S. viridans, S. aureus, S. epidermidi
  • various bacteria: 61%.
  • S. viridans: 2.7%.
  • S. aureus: 1.4%.
Rails of grids/tracks or floor, inside of suction bottle, folds in stretcher mattress, offside wall near stretcher mattress, inside mask (Entonox).[6]
USA2006One air ambulance
(helicopter, 7 surfaces).
Staphylococcus sp., Pseudomonas sp., E. coli, Bacillus sp., Aspergillus sp.
  • Staphylococcus sp.: 6/7 samples (86%).
  • Pseudomonas sp.: 2/7 samples (29%)
Door handles, seat tracks, stretcher.[7]
USA201051 ambulances (16 surfaces).MRSA.MRSA detected in 50% of ambulances (25/51):
  • Fire Department ambulances (25/51), with 56% (14/25) contaminated.
  • Private nonprofit ambulances (19/51), with 45% (9/19) contaminated.
  • Hospital-based ambulances (5/51), with 20% (1/5) contaminated.
  • Third-service municipal ambulances (2/51), with 50% (1/2) contaminated.
Stretcher rail, work area beside patient, pulse oximeter. [8]
Germany201189 transport events with MRSA notification and 60 transport events
without MRSA notification
(5 surfaces).
MRSA, MSSA
  • MRSA was found in 8 out of 89 transport events, representing 9% of transports with an MRSA notification. The distribution is as follows: stretcher headrest—5 out of 8 (63%); stretcher handles—2 out of 8 (25%); both headrest and stretcher handles—1 out of 8 (12%).
  • MSSA was identified in 12 out of 60 transport events, accounting for 20% of transports without MRSA notification. The distribution is as follows: stretcher headrest—5 out of 12 (42%); stretcher handles—6 out of 12 (50%); cabin wall—1 out of 12 (<1%).
Stretcher headrest and handles.[9]
South Korea201113 ambulances
(33 surfaces).
K. pneumoniae ESBL, P. aeruginosa, MRCoNS, MRSA. aAll ambulances showed microbial contamination. from 429 total surfaces, 396/624 (64%) sample cultures positive for organisms.
  • Two K. pneumoniae ESBL from water in suction bottle, and bag-valve mask bag.
  • One P. aeruginosa.
  • One MRCoNS from stretcher car side bar.
  • One MRSA from driver’s side door handle.
Water from suction bottles, stretcher car side bars, bag-valve mask bag, driver’s side door handle.[10]
USA201271 ambulances
(26 surfaces).
MRSA, MSSA.Out of 71 ambulances, 49 had at least one isolate of S. aureus, with 100 out of 1,125 isolates identified as S. aureus. Among these isolates, 77% were resistant to ≥one antibiotic, and 34% were resistant to ≥two antibiotics.
Regarding MRSA, 5 out of 71 ambulances tested positive, with 9 out of 26 surfaces showing at least one MRSA isolate, totaling 12 isolates.
For MSSA, 49 out of 71 ambulances had isolates, with 22 out of 26 surfaces containing at least one MSSA isolate, resulting in a total of 88 isolates.
Portable pulse oximetry finger sensors, automatic pulse finger sensors, portable pulse oximeter outer case, workspace deck, automatic blood pressure cuffs. [11]
South Korea201230 ambulances
(33 surfaces).
S. aureus, P. aeruginosa, Serratia marcescens, Legionella spp. aAll ambulances tested positive for contamination on at least 3 surfaces, with 159 out of 955 surfaces found to be contaminated. A total of 28 bacterial species were isolated, resulting in 184 total isolates of pathogenic bacteria (14 out of 184, or 8%):
  • S. aureus accounted for 7 out of 184 isolates (8%) and was found on the endotracheal tube and suction tip.
  • P. aeruginosa accounted for 4 out of 184 isolates (2%); it was isolated from the suction tip, oropharyngeal airway, and oxygen humidifier water.
  • S. marcescens represented 2 out of 184 isolates (1%) and was retrieved from the endotracheal tube.
  • Legionella was detected in 1 out of 184 isolates (0.5%), deriving from suction water.
100% endotracheal tube, 90% oxygen humidifier (water), 80% water from suction reservoirs.[12]
Iraq2013139 ambulances, including air ambulances
(6 surfaces).
Pantoea agglomerans, Shigella flexneri, Pseudomonas spp., Escherichia vulneris, K. pneumoniae.In 13 out of 139 ambulances, 79 out of 134 swabs revealed at least one Gram-negative colony-forming unit. Among the isolated organisms, P. agglomerans accounted for 34%, while S. flexneri represented 8%. Additionally, Pseudomonas spp., E. vulneris, and K. pneumoniae each comprised 6% of the isolates.Door handles, panels, steering wheels, electronic equipment, stretchers, floors.[13]
Saudi Arabia201410 ambulances
(3 surfaces).
Bacillus sp., CoNS. aContamination was observed on three surfaces before and after the fumigation of the ambulance. The oxygen knob showed a contamination occurrence of 9 before fumigation and 1 after, while the stretcher handle had 8 before and 1 after. The interior handle of the rear door presented contamination levels of 10 before fumigation and 4 afterward.100% interior handle of rear door, 90% oxygen knob, 80% stretcher handle.[14]
Thailand201530 ambulances
(318 air samples).
S. aureus, Aspergillus sp., Fusarium sp., Penicillium sp.S. aureus (47/91 samples; 51.6%).Stretchers, air-flow fins, stethoscope, oxygen flow knob.[15]
Germany2015150 ambulances
(28 surfaces).
S. aureus, MRSA, CoNS. a11/150 ambulances; 10/28 surfaces.
MRSA was detected on 18 plates.
Carrying handles, oxygen saturation clip, patient stretcher handle, cardiovascular bag handle, patient stretcher headboard, BP cuff, pharmacist cabinet handle, carrying chair, ECG control panel.[16]
Australia20162 Air ambulances
(helicopters; 5 surfaces).
MSSA, S. epidermidis.MSSA (19/60 samples; 32%). Floor of helicopters, seat, blood pressure cuff containers.[17]
Denmark201639 ambulances
(1 surface).
S. aureus, Enterococcus.Out of 50 blood pressure cuffs examined, including 11 duplicate cuffs, contamination was found in 6. Specifically, S. aureus was identified in 5 of the cuffs, accounting for 10%, while Enterococcus was present in 1 cuff, representing 2%.Blood pressure cuffs.[18]
Spain201710 ambulances
(4 surfaces).
CoNS, MSSA, Enterobacterales, nonfermenting Gram-negative bacilli, Enterococci, Bacillus spp. aContamination was detected on 26 out of 40 surfaces in the patient compartment. Among the isolates, CoNS were found in 15 out of 44 instances, representing 34%. Additionally, non-fermenting Gram-negative bacilli, Enterobacterales, Enterococci, and Bacillus spp. were identified in 26 out of 44 cases, accounting for 59%.Interior passenger door handle, left handle of stretcher, steering wheel.[19]
Denmark201880 ambulances
(6 surfaces).
S. aureus including MRSA, Enterococcus including VRE, Enterobacterales.Contamination was found on 49 out of 480 ambulance surfaces, with S. aureus detected in 7% of cases and Enterobacterales in 1%. In total, 108 sites tested positive for pathogens, including two instances of VRE and one case of MRSA.Blood pressure cuffs, medical bag handles, patient harness.[20]
Egypt201825 ambulances
(16 surfaces).
Staphylococcus spp. including MRSA and MRCoNS, Klebsiella pneumoniae including K. pneumoniae ESBL, Escherichia coli including E. coli ESBL, Citrobacter spp., Proteus spp. aIn all ambulances, contamination was identified on 400 out of 400 surfaces. A total of 184 staphylococcal isolates were found, with MRSA accounting for 35 out of 184 isolates, representing 19%, and MRCoNS comprising 22 out of 184 isolates (12%). Additionally, there were 49 isolates of K. pneumoniae, with 18 out of those 49 being ESBL producers (37%). Furthermore, 40 isolates of E. coli were identified, and among those, 11 out of 40 were classified as ESBL producers (3%).Headboard of patient stretcher, suction devices, beds.[21]
USA20193 ambulances
(13 surfaces).
MRSA.In all ambulances, contamination was detected on 5 out of 39 surfaces, with MRSA identified in 13 out of 39 instances (33%). Specifically, all 9 oxygen cylinders showed contamination, averaging 3 per ambulance, while contamination was found on the patient compartment floor in all 3 cases and on the rear door handle in 1 out of 3 instances.Oxygen cylinders.[22]
Iran202012 ambulances
(18 surfaces).
CoNS, Klebsiella spp., Acinetobacter spp., Pseudomonas spp., Proteus spp., Corynebacterium diphtheriae.All ambulances and all surfaces (100%).
  • CoNS, 76 isolates.
  • Klebsiella spp, 8 isolates.
  • Acinetobacter spp., 6 isolates.
  • Pseudomonas spp., 6 isolates.
  • Proteus spp., 4 isolates.
  • C. diphtheriae, 2 isolates.
Oxygen tank.[23]
India20215 ambulances
(22 surfaces).
S. aureus, Klebsiella spp., Escherichia coli, Proteus spp., Enterococcus spp., Pseudomonas aeruginosa.Out of 198 swabs, 170 (85.8%) were found to be sterile, while 28 swabs (14.2%) yielded bacterial isolates. Among these isolates, S. aureus accounted for 32%, with MRSA making up 22% of the S. aureus isolates. Additionally, Klebsiella spp. comprised 21.4%, E. coli represented 14.2%, and Proteus spp. also accounted for 14.2%. Enterococcus spp. contributed 10.7%, while P. aeruginosa represented 7.2% of the isolates.Oxygen flow meter knob (60%), suction machine tubing (60%), stethoscope (40%).[24]
Poland2024One ambulance
(20 surfaces).
MRSA, MSSA.20 (51.28%) swabs yielded S. aureus, of which MRSA represented 40% (8/20 swabs), and MSSA represented 60% (12/20 swabs).The highest contamination rates for MRSA were found on surfaces such as the tourniquet, pulse oximeter, stethoscope, glucometer, defibrillator panels with buttons, and door handles.
In contrast, the surfaces with the highest rates of MSSA included the pressure stasis device, blood pressure cuff, steering wheel, ECG cables, and defibrillator screens and panels with buttons, as well as the stretcher’s head support and mattress.
[25]
BP, blood pressure; CoNS, coagulase-negative Staphylococci; ECG, electrocardiogram; E. coli, Escherichia coli; ESBL, extended-spectrum b-lactamase; K. pneumoniae, Klebsiella pneumoniae; MRCoNS, methicillin-resistant coagulase-negative Staphylococci; MRSA, methicillin-resistant Staphylococcus aureus; MSSA, methicillin-sensitive Staphylococcus aureus, P. aeruginosa, Pseudomonas aeruginosa; S. aureus, Staphylococcus aureus; S. viridans, Streptococcus viridans; VRE, vancomycin-resistant Enterococci. a Various other bacteria and/or fungi were detected.

References

  1. Roberts, M.H.; Sim, M.R.; Black, O.; Smith, P. Occupational injury risk among ambulance officers and paramedics compared with other healthcare workers in Victoria, Australia: Analysis of workers’ compensation claims from 2003 to 2012. Occup. Environ. Med. 2015, 72, 489–495. [Google Scholar] [CrossRef] [PubMed]
  2. Obenza, A.; Cruz, P.; Buttner, M.; Woodard, D. Microbial contamination on ambulance surfaces: A systematic literature review. J. Hosp. Infect. 2022, 122, 44–59. [Google Scholar] [CrossRef] [PubMed]
  3. Hudson, A.J.; Glaister, G.D.; Wieden, H.J. The Emergency Medical Service Microbiome. Appl. Environ. Microbiol. 2018, 84, e02098-17. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  4. World Health Organization (WHO). Report on the Burden of Endemic Health Care-Associated Infection Worldwide; World Health Organization: Geneva, Switzerland, 2011; Available online: http://apps.who.int/iris/bitstream/10665/80135/1/9789241501507_eng.pdf (accessed on 15 November 2025).
  5. Centers for Disease Control and Prevention (CDC). Antibiotic Resistance Threats in the United States, 2013 (Report CS239559-B); Centers for Disease Control and Prevention: Atlanta, GA, USA, 2013. Available online: https://www.cdc.gov/antimicrobial-resistance/media/pdfs/ar-threats-2013-508.pdf (accessed on 15 November 2025).
  6. Nigam, Y.; Cutter, J. A preliminary investigation into bacterial contamination of Welsh emergency ambulances. Emerg. Med. J. 2003, 20, 479–482. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  7. Galtelli, M.; Deschamp, C.; Rogers, J. An assessment of the prevalence of pathogenic microorganisms in the rotor wing ambulance: One program’s findings. Air Med. J. 2006, 25, 81–84. [Google Scholar] [CrossRef]
  8. Brown, R.; Minnon, J.; Schneider, S.; Vaughn, J. Prevalence of methicillin-resistant Staphylococcus aureus in ambulances in southern Maine. Prehospital Emerg. Care 2010, 14, 176–181. [Google Scholar] [CrossRef] [PubMed]
  9. Eibicht, S.J.; Vogel, U. Meticillin-resistant Staphylococcus aureus (MRSA) contamination of ambulance cars after short term transport of MRSA-colonised patients is restricted to the stretcher. J. Hosp. Infect. 2011, 78, 221–225. [Google Scholar] [CrossRef] [PubMed]
  10. Noh, H.; Shin, S.D.; Kim, N.J.; Ro, Y.S.; Oh, H.S.; Joo, S.I.; Kim, J.I.; Ong, M.E. Risk stratification-based surveillance of bacterial contamination in metropolitan ambulances. J. Korean Med. Sci. 2011, 26, 124–130. [Google Scholar] [CrossRef] [PubMed] [PubMed Central][Green Version]
  11. Rago, J.V.; Buhs, L.K.; Makarovaite, V.; Patel, E.; Pomeroy, M.; Yasmine, C. Detection and analysis of Staphylococcus aureus isolates found in ambulances in the Chicago metropolitan area. Am. J. Infect. Control. 2012, 40, 201–205. [Google Scholar] [CrossRef] [PubMed]
  12. Yoo, S.; You, Y.; Kwan, K.C.; Jeong, T.O. Bacterial contamination conditions in ambulances and their equipment in South Korea. J. Korean Soc. Emerg. Med. 2012, 23, 1–7. [Google Scholar]
  13. Lesho, E.; Ake, J.; Huang, X.Z.; Cash, D.M.; Nikolich, M.; Barber, M.; Robens, K.; Garnett, E.; Lindler, L.; Scott, P. Amount of usage and involvement in explosions not associated with increased contamination of prehospital vehicles with multi-drug-resistant organisms. Prehospital Disaster Med. 2013, 28, 107–109. [Google Scholar] [CrossRef] [PubMed]
  14. Alrazeeni, D.; Al Sufi, M.S. Nosocomial infections in ambulances and effectiveness of ambulance fumigation techniques in Saudi Arabia. Phase I study. Saudi. Med. J. 2014, 35, 1354–1360. [Google Scholar] [PubMed] [PubMed Central]
  15. Luksamijarulkul, P.; Pipitsangjan, S. Microbial air quality and bacterial surface contamination in ambulances during patient services. Oman Med. J. 2015, 30, 104–110. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  16. Wepler, M.; Stahl, W.; von Baum, H.; Wildermuth, S.; Dirks, B.; Georgieff, M.; Hafner, S. Prevalence of nosocomial pathogens in German ambulances: The SEKURE study. Emerg. Med. J. 2015, 32, 409–411. [Google Scholar] [CrossRef] [PubMed]
  17. Makiela, S.; Taylor-Robinson, A.W.; Weber, A.; Maguire, B.J. A preliminary assessment of contamination of emergency service helicopters with MRSA and multi-resistant Staphylococcus aureus. Emerg. Med. Open Access 2016, 6, 1–6. [Google Scholar] [CrossRef]
  18. Vikke, H.S.; Giebner, M. POSAiDA: Presence of Staphylococcus aureus/MRSA and Enterococcus/VRE in Danish ambulances. A cross-sectional study. BMC Res. Notes 2016, 9, 194. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  19. Varona-Barquin, A.; Ballesteros-Peña, S.; Lorrio-Palomino, S.; Ezpeleta, G.; Zamanillo, V.; Eraso, E.; Quindós, G. Detection and characterization of surface microbial contamination in emergency ambulances. Am. J. Infect. Control. 2017, 45, 69–71. [Google Scholar] [CrossRef] [PubMed]
  20. Vikke, H.S.; Giebner, M.; Kolmos, H.J. Prehospital infection control and prevention in Denmark: A cross-sectional study on guideline adherence and microbial contamination of surfaces. Scand. J. Trauma Resusc. Emerg. Med. 2018, 26, 71. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  21. El-Mokhtar, M.A.; Hetta, H.F. Ambulance vehicles as a source of multidrug-resistant infections: A multicenter study in Assiut City, Egypt. Infect. Drug Resist. 2018, 11, 587–594. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  22. Gibson, C.V. Emergency medical services oxygen equipment: A fomite for transmission of MRSA? Emerg. Med. J. 2018, 36, 89–91. [Google Scholar] [CrossRef] [PubMed]
  23. Paravar, M.; Safavi, S.; Eghtesadi, R.; Mohamadzade, M.; Sehat, M.; Fazel, M.; Fakharian, E.; Makki, M.; Erami, M.; Taghipor, T.; et al. The prevalence of Staphylococcus aureus contamination in the ambulances and on-all emergency medical service personnel of Kashan city in Iran. J. Emerg. Pract. Trauma 2019, 6, 3–6. [Google Scholar] [CrossRef]
  24. Sharma, S.; Datta, P.; Gupta, V.; Vasesi, D.; Chander, J. Bacteriological Surveillance of Ambulance Vehicles from a Tertiary Care Hospital of North India. J. Lab. Physicians 2021, 13, 202–207. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  25. Leszczyński, P.K.; Olędzka, A.; Wierzchowska, K.; Frankowska-Maciejewska, A.; Mitura, K.M.; Celinski, D. Occurrence and Phenotypic Characteristics of Methicillin-Resistant Staphylococcus aureus (MRSA) in Emergency Medical Service Ambulances as a Potential Threat to Medical Staff and Patients. J. Clin. Med. 2024, 13, 7160. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  26. Ehling-Schulz, M.; Lereclus, D.; Koehler, T.M. The Bacillus cereus Group: Bacillus Species with Pathogenic Potential. Microbiol. Spectr. 2019, 7, 10–128. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  27. Kao, C.C.; Chiang, C.K.; Huang, J.W. Micrococcus species-related peritonitis in patients receiving peritoneal dialysis. Int. Urol. Nephrol. 2012, 46, 261–264. [Google Scholar] [CrossRef] [PubMed]
  28. Huang, X.; Yu, L.; Sun, C.; Xiao, F.; Jia, N.; Chen, M.; Zhang, Y.; Fu, J.; Xu, Z.; Cui, X.; et al. Visual and fluorescent detection of Moraxella catarrhalis by multiple cross displacement amplification-based assay. Heliyon 2024, 10, e38805. [Google Scholar] [CrossRef] [PubMed] [PubMed Central]
  29. Daniel, W.W. (Ed.) Biostatistics: A Foundation for Analysis in the Health Sciences, 7th ed.; John Wiley & Sons: New York, NY, USA, 1999. [Google Scholar]
  30. Cheesbrough, M. (Ed.) Microbiological tests. In District Laboratory Practice in Tropical Countries; Cambridge University Press: New York, NY, USA, 2006; pp. 62–70. [Google Scholar]
  31. Clinical and Laboratory Standards Institute (CLSI). Performance Standards for Antimicrobial Susceptibility Testing, 35th ed.; CLSI Supplement M100; Clinical and Laboratory Standards Institute: Wayne, PA, USA, 2025. [Google Scholar]
  32. Dancer, S.J. Hospital cleaning in the 21st century. Eur. J. Clin. Microbiol. Infect. Dis. 2011, 30, 1473–1481. [Google Scholar] [CrossRef] [PubMed]
  33. Mulvey, D.; Redding, P.; Robertson, C.; Woodall, C.; Kingsmore, P.; Bedwell, D.; Dancer, S.J. Finding a benchmark for monitoring hospital cleanliness. J. Hosp. Infect. 2011, 77, 25–30. [Google Scholar] [CrossRef] [PubMed]
  34. Saudi Ministry of Health (MOH; 2019). Emergency Medical Services (EMS) Infection Control Guidelines. Available online: https://jed-s3.bluvalt.com/psj1-ifn-s3-ifn01/files/03/Guidelines/Emergency-Medical-Services-EMS-Infection-Control-Guidelines-2019.pdf (accessed on 15 November 2025).
  35. Giovinazzo, R.; Caradonna, L.; Giaquinta, G.; Guerrera, E.; Mameli, M.; Mansi, A.; Marena, G.; Mastromartino, T.; Sarto, D.; Tomao, P. Benchmark Guidance Values for Microbiological Monitoring on Surfaces: A Literature Overview. Biomed. Prev. Issues 2017, 4, 174–180. [Google Scholar] [CrossRef]
Table 1. Frequencies of positive bacterial growth from each site of the ambulance vehicles based on the samples collected following patient transport.
Table 1. Frequencies of positive bacterial growth from each site of the ambulance vehicles based on the samples collected following patient transport.
SiteNumber of Swab Samples CollectedBacterial-Growth-Positive Samples: n. (%)Test of Significance—Chi-Square Test (X2) p
Carrying handle of cart124 (33.33%)2.667FE p = 0.220
Sidebar of cart124 (33.33%)2.667FE p = 0.220
DC shock apparatus1210 (83.33%)10.667FE p = 0.003 *
Stethoscope125 (41.67%)0.6670.414
Cervical collar126 (50.00%)0.0001.000
Inside wall of the vehicle125 (41.67%)0.6670.414
Ceiling129 (75.00%)6.000FE p = 0.039 *
Medical bag handles125 (41.67%)0.6670.414
Emergency personnel seats128 (66.66%) 2.667FE p = 0.220
Portable ventilator126 (50.00%)0.0001.000
Blood pressure cuff123 (25.00%)6.000FE p = 0.039 *
Monitor125 (41.67%)0.6670.414
Door grip125 (41.67%)0.6670.414
Oxygen humidifier glass123 (25.00%)6.000FE p = 0.039 *
Suction device125 (41.67%)0.6670.414
Headboard of patient stretcher125 (41.67%)0.6670.414
Steering wheel126 (50.00%)0.0001.000
THE SUM20494 (46.08%)--
FE: Fisher Exact. X2: Chi-square test. * The result is statistically significant at p ≤ 0.05. Statistically, it is clear that DC shock apparatuses and ceilings have a greater probability of being contaminated. In contrast, blood pressure cuffs and oxygen humidifier glass have a greater likelihood of being noncontaminated.
Table 2. Frequencies of bacterial isolates in each site of ambulances based on the samples collected following patient transport.
Table 2. Frequencies of bacterial isolates in each site of ambulances based on the samples collected following patient transport.
SitePositive Bacterial Growth
Number of Bacterial IsolatesPercentage (Number of Bacterial Isolates/102 Isolates)
Carrying handle of cart43.9%
Sidebar of cart54.9%
DC shock apparatus109.8%
Stethoscope54.9%
Cervical collar76.8%
Inside wall of the vehicle54.9%
Ceiling1110.8%
Medical bag handles54.9%
Emergency personnel seats87.8%
Portable ventilator65.9%
Blood pressure cuff32.9%
Monitor76.8%
Door grip65.9%
Oxygen humidifier glass32.9%
Suction device54.9%
Headboard of patient stretcher65.9%
Steering wheel65.9%
THE SUM; n. (%)102100.0%
Table 3. Distribution of bacterial isolates on each site in the ambulances, as derived from the samples collected following patient transport.
Table 3. Distribution of bacterial isolates on each site in the ambulances, as derived from the samples collected following patient transport.
SiteBacillus spp.
n.
Micrococcus spp.
n.
Moraxella spp.
n.
Staphylococcus epidermidis
n.
Staphylococcus saprophyticus
n.
Proteus spp.
n.
Pseudomonas aeruginosa
n.
Streptococcus viridans
n.
Carrying handle of cart22000000
Sidebar of cart22001000
DC shock apparatus80100001
Stethoscope50000000
Cervical collar61000000
Inside wall of the vehicle23000000
Ceiling73010000
Medical bag handles31001000
Emergency personnel seats53000000
Portable ventilator33000000
Blood pressure cuff30000000
Monitor40100110
Door grip33000000
Oxygen humidifier glass12000000
Suction device23000000
Headboard of patient stretcher42000000
Steering wheel23010000
Frequency; n. (%)62/102
(60.8%)
31/102
(30.4%)
2/102
(1.96%)
2/102
(1.96%)
2/102
(1.96%)
1/102
(0.98%)
1/102
(0.98%)
1/102
(0.98%)
Table 4. Antimicrobial resistance patterns of Gram-positive bacterial isolates, as derived via disc diffusion method. Data shown are frequencies (n (%)).
Table 4. Antimicrobial resistance patterns of Gram-positive bacterial isolates, as derived via disc diffusion method. Data shown are frequencies (n (%)).
AntibioticBacillus spp.
n. 62 (60.8%)
Micrococcus spp.
n. 31 (30.4%)
Staphylococcus epidermidis
n. 2 (1.96%)
Staphylococcus saprophyticus n. 2 (1.96%)Streptococcus viridans
n. 1 (0.98%)
AP: Ampicillin 10 μg1 (1.6%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
AK: Amikacin 30 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
AUG: Augmentin 30 μg1 (1.6%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
BA: Bacitracin 10 U14 (22.6%)2 (6.5%)0 (0.0%)0 (0.0%)0 (0.0%)
C: Chloramphenicol 30 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
CAZ: Ceftazidime 30 μg1 (1.6%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
CIP: Ciprofloxacin 5 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
CD: Clindamycin 2 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
CPM: Cefepime 30 μg0 (0.0%)1 (3.2%)0 (0.0%)1 (50.0%)0 (0.0%)
E: Erythromycin 15 μg0 (0.0%)4 (12.9%)1 (50.0%)0 (0.0%)0 (0.0%)
FOX: Cefoxitin 30 μg1 (1.6%)1 (3.2%)0 (0.0%)0 (0.0%)0 (0.0%)
GM: Gentamicin 10 μg1 (1.6%)2 (6.5%)0 (0.0%)0 (0.0%)1 (100.0%)
IPM: Imipenem 10 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
KF: Cephalothin 30 μg4 (6.5%)2 (6.5%)1 (50.0%)0 (0.0%)1 (100.0%)
NE: Neomycin 30 μg1 (1.6%)1 (3.2%)0 (0.0%)0 (0.0%)1 (100.0%)
OT: Oxytetracycline 30 μg0 (0.0%)1 (3.2%)0 (0.0%)0 (0.0%)1 (100.0%)
OX: Oxacillin 5 μg3 (4.8%)3 (9.7%)2 (100.0%)1 (50.0%)1 (100.0%)
PG: Penicillin G 10 U31 (50.0%)11 (35.5%)1 (50.0%)2 (100.0%)1 (100.0%)
PRL: Piperacillin 30 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
T: Tetracycline 30 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)1 (100.0%)
TS: Cotrimoxazole 25 μg11 (17.7%)5 (16.1%)0 (0.0%)2 (100.0%)1 (100.0%)
VA: Vancomycin 30 μg0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)0 (0.0%)
Table 5. Recommendations for ambulance decontamination (cleaning and disinfection) following patient transport according to the Saudi Ministry of Health infection control guidelines [34].
Table 5. Recommendations for ambulance decontamination (cleaning and disinfection) following patient transport according to the Saudi Ministry of Health infection control guidelines [34].
SiteStandardDecontamination FrequencyAdditional Considerations
Carrying handle of cartIt must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each patient care procedure.-
Sidebar of cartIt must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each patient care procedure.-
DC shock apparatusAll parts must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each patient use.-
StethoscopeIt must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each patient use.-
Cervical collarAll parts must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each patient use.-
Inside wall of the vehicleAll wall surfaces must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, adhesive tape, or any spillages. Every week. If contaminated, decontaminate it as soon as possible before further patient transfer.
CeilingAll surfaces must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, adhesive tape, or any spillages.Every week. If contaminated, decontaminate it as soon as possible before further patient transfer.
Response kits and medical bagsAll parts of medical bags must be visibly clean and free of dust, dirt, blood, bodily fluids, or any spillages.Bags frequently brought into patient care areas must be decontaminated after each use, especially if they are contaminated with blood or bodily fluids. Heavily used bags should be laundered weekly or monthly, while those used less frequently should be cleaned every other month.All bags used in ambulances should be made from materials that can be easily wiped clean. Any bag that is heavily contaminated with blood or bodily fluids should be disposed of.
Emergency personnel seatsThe cover must be free of damage. All components, including seatbelts and the areas underneath, should be visibly clean and free from dust, dirt, stains, blood, bodily fluids, or any spillages.After each use.Replace seatbelts if they are heavily contaminated with blood or bodily fluids. Torn or damaged seat covers should also be replaced.
Portable ventilatorAll components, including the valve and cylinder, must be visibly clean and free from dust, dirt, stains, blood, bodily fluids, or any spillages.After each use.Single-use items should be replaced after each use.
Blood pressure cuffAll parts must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each patient use.-
MonitorAll parts must be visibly clean and free of dust, dirt, blood, bodily fluids, or any spillages.After each patient use.-
Door gripIt must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each patient use.-
Oxygen humidifier glassAll parts, including the valve and cylinder, must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each use.Single-use items should be replaced after each use.
Suction deviceAll parts, including the valve and cylinder, must be visibly clean and free of dust, dirt, stains, blood, bodily fluids, or any spillages.After each use.Single-use items should be replaced after each use.
StretcherAll parts must be visibly clean and free of dust, dirt, blood, bodily fluids, or any spillages.After each patient use.-
Driver’s compartmentAll areas of the driver’s compartment must be visibly clean and free from dust, dirt, debris, blood, bodily fluids, or any spillages.After every patient care procedure, if the driver participated in direct patient care, such as moving the patients on stretchers.
After completing the direct patient care procedure and before entering the driver’s compartment, drivers should remove PPE (except masks/respirators) and ensure hand hygiene to avoid contamination of the driver’s compartment.
If possible, employ cars with separate driver and patient compartments that allow for separate ventilation. Before bringing the patient aboard, close the door or window between these compartments. Clean and vacuum the floor.
Table 6. Recommended ambulance disinfectants according to the Saudi Ministry of Health infection control guidelines [34].
Table 6. Recommended ambulance disinfectants according to the Saudi Ministry of Health infection control guidelines [34].
ProductsDisadvantageAdvantagesUses
Standard Bleach
(Normal dilution 1:10)
It damages metals and can be deactivated by organic materials, necessitating a clean surface before use. It can stain clothing. It can also irritate mucous membranes and skin, and once diluted, it should be used within 24 h.It is inexpensive, acts quickly, and is easily accessible. It comes in convenient, ready-to-use wipes and sprays and is both viricidal and sporicidal, making it effective against Norovirus as well as spore-forming bacteria like Clostridia and Bacillus spp.
-
Blood spills
-
External surfaces
Alcohol
(70–95%)
It evaporates quickly and is not the best choice for surface disinfection. It is highly flammable and can damage plastic, silicone, and rubber. Additionally, it is rendered ineffective by organic materials, so surfaces must be cleaned before use.It is non-toxic, affordable, acts quickly, and leaves no residue.External surfaces of certain pieces of equipment, including stethoscopes and pulse oximeters.
Quaternary ammonium compoundsThey are unsuitable for disinfecting medical instruments and have limited application potential as disinfectants due to their narrow range of effectiveness against microbes.They are non-toxic and non-corrosive and possess effective cleaning properties thanks to their detergent properties.
-
Walls, floors, and furnishings
-
Blood spills, prior to disinfection
Hydrogen PeroxideIt damages materials such as copper, zinc, brass, acrylics, and aluminum. It also leaves a visible residue behind.It is environmentally safe and non-toxic and acts quickly while remaining effective even in the presence of organic substances. It is available in both wipes and liquid form and offers excellent cleaning capabilities due to its excellent detergent properties.
-
Walls, floors, and furnishings
-
External surfaces of some pieces of equipment
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Taha, A.E.; Alharbi, A.R.; Alharbi, O.N.; Komila, A.M.; Almushawwah, A.; Aldeghaim, S.; Algefary, A.N.; Allahim, M.; Alzaben, K.; Alharbi, F.M. Bacterial Contaminants in Ambulances from a Tertiary Care Hospital as Potential Threats to Patients and Medical Staff in Al-Qassim Region, Saudi Arabia—Effect of Decontamination. Pathogens 2025, 14, 1301. https://doi.org/10.3390/pathogens14121301

AMA Style

Taha AE, Alharbi AR, Alharbi ON, Komila AM, Almushawwah A, Aldeghaim S, Algefary AN, Allahim M, Alzaben K, Alharbi FM. Bacterial Contaminants in Ambulances from a Tertiary Care Hospital as Potential Threats to Patients and Medical Staff in Al-Qassim Region, Saudi Arabia—Effect of Decontamination. Pathogens. 2025; 14(12):1301. https://doi.org/10.3390/pathogens14121301

Chicago/Turabian Style

Taha, Ahmed E., Ahmad R. Alharbi, Omar N. Alharbi, Alaaeldin M. Komila, Abdullah Almushawwah, Solaiman Aldeghaim, Ahmed N. Algefary, Majed Allahim, Khalid Alzaben, and Faisal M. Alharbi. 2025. "Bacterial Contaminants in Ambulances from a Tertiary Care Hospital as Potential Threats to Patients and Medical Staff in Al-Qassim Region, Saudi Arabia—Effect of Decontamination" Pathogens 14, no. 12: 1301. https://doi.org/10.3390/pathogens14121301

APA Style

Taha, A. E., Alharbi, A. R., Alharbi, O. N., Komila, A. M., Almushawwah, A., Aldeghaim, S., Algefary, A. N., Allahim, M., Alzaben, K., & Alharbi, F. M. (2025). Bacterial Contaminants in Ambulances from a Tertiary Care Hospital as Potential Threats to Patients and Medical Staff in Al-Qassim Region, Saudi Arabia—Effect of Decontamination. Pathogens, 14(12), 1301. https://doi.org/10.3390/pathogens14121301

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop