Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners

1
School of Civil Engineering and Communication, North China University of Water Resources and Electric Power, Zhengzhou 450045, China
2
International Joint Research Lab for Eco-Building Materials and Engineering of Henan, North China University of Water Resources and Electric Power, Zhengzhou 450045, China
3
School of Highway, Chang’an University, Xi’an 710064, China
4
Collaborative Innovation Center for Efficient Utilization of Water Resources, North China University of Water Resources and Electric Power, Zhengzhou 450046, China
*
Authors to whom correspondence should be addressed.
Buildings 2024, 14(11), 3678; https://doi.org/10.3390/buildings14113678
Submission received: 23 October 2024 / Revised: 15 November 2024 / Accepted: 18 November 2024 / Published: 19 November 2024
(This article belongs to the Special Issue Experimental and Theoretical Studies on Steel and Concrete Structures)

Abstract

To better understand the bending performance of rectangular high-strength steel fiber-reinforced concrete (HSFRC)-filled steel tubular (HSFRCFST) beams with internal stiffeners, ten beams were subjected to a four-point bending test. The primary considerations were the strength grade of the HSFRC, the steel fiber content, the internal stiffener type, and the circular hole spacing of the perfobond stiffener. The moment–curvature and flexural load–deflection curves were calculated. The mode of failure and the distribution of cracks of the infill HSFRC were observed. The presence of steel fibers greatly improved the bending stiffness and moment capacity of HSFRCFST beams, with the optimal effect happening at a steel fiber content of 1.2% by volume, according to the experimental findings. The type of stiffener influenced the failure modes of the exterior rectangular steel tube, which were unaffected by the compressive strength of the infill HSFRC. On the tension surface of HSFRCFST beams, the crack spacing of the infill HSFRC was virtually identical to the circular hole spacing of perfobond stiffeners. When the circular hole spacing was between two and three times the diameter, the perfobond stiffener worked best with the infill HSFRC. The test beams’ ductility index was greater than 1.16, indicating good ductility. The test beams’ rotational capacities ranged from 6.26 to 13.20, which were greater than 3.0 and met the requirements of the specification. The experimental results demonstrate that a reasonable design of the steel fiber content and the spacing between circular holes of perfobond stiffeners can significantly improve the bending resistance of rectangular HSFRCFST beams. This provides relevant parameter design suggestions for improving the ductility and bearing capacity of steel fiber-reinforced concrete beams in practical construction. Finally, a design formula for the moment capacity of rectangular HSFRCFST beams with stiffeners is presented, which corresponds well with the experimental findings.
Keywords: concrete-filled steel tubular beams; rectangular section; high-strength steel fiber-reinforced concrete; perfobond stiffener; flexural capacity concrete-filled steel tubular beams; rectangular section; high-strength steel fiber-reinforced concrete; perfobond stiffener; flexural capacity

Share and Cite

MDPI and ACS Style

Liu, S.; Ji, Z.; Li, S.; Li, X.; Liu, Y.; Zhao, S. Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners. Buildings 2024, 14, 3678. https://doi.org/10.3390/buildings14113678

AMA Style

Liu S, Ji Z, Li S, Li X, Liu Y, Zhao S. Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners. Buildings. 2024; 14(11):3678. https://doi.org/10.3390/buildings14113678

Chicago/Turabian Style

Liu, Shiming, Zhaoyang Ji, Shangyu Li, Xiaoke Li, Yongjian Liu, and Shunbo Zhao. 2024. "Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners" Buildings 14, no. 11: 3678. https://doi.org/10.3390/buildings14113678

APA Style

Liu, S., Ji, Z., Li, S., Li, X., Liu, Y., & Zhao, S. (2024). Bending Test of Rectangular High-Strength Steel Fiber-Reinforced Concrete-Filled Steel Tubular Beams with Stiffeners. Buildings, 14(11), 3678. https://doi.org/10.3390/buildings14113678

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop