Intra-Rater Reliability and Construct Validity of Hand-Held Dynamometry to Evaluate the Hip Adductor Squeeze Test in Elite Youth Football Players
Abstract
1. Introduction
2. Materials and Methods
2.1. Study Design
2.2. Participants
2.3. Inclusion and Exclusion Criteria
2.4. Researchers and Familiarisation Procedure
2.5. Testing Location and Scheduling
2.6. Equipment and Testing Protocol
- Hand-Held Dynamometer: MicroFET®2 (Hoggan Scientific, Salt Lake City, UT, USA)
- ForceFrame System: VALD Performance (Brisbane, Australia)
2.7. Statistical Analysis
2.7.1. Intra-Rater Reliability
- Standard Error of Measurement (SEM): SEM = SD × √(1 − ICC);
- Relative SEM (SEM%): SEM/mean score × 100;
- Minimal Detectable Change (MDC): MDC = SEM × 1.96 × √2;
- Relative MDC (MDC%): MDC/mean score × 100;
- Coefficient of Variation (CV%): (SD/mean) × 100.
2.7.2. Construct Validity
3. Results
3.1. Descriptive Data
3.2. Intra-Rater Reliability
3.3. Construct Validity
4. Discussion
4.1. Intra-Rater Reliability
4.2. Construct Validity
4.3. Limitations
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
References
- Ergun, M.; Denerel, H.N.; Sebik, O.; Ertat, K.A. Injuries in elite youth football players: A prospective three-year study. Acta Orthop. Traumatol. Turc. 2013, 47, 339–346. [Google Scholar] [CrossRef]
- Ekstrand, J.; Hägglund, M.; Waldén, M. Epidemiology of muscle injuries in professional football (soccer). Am. J. Sports Med. 2011, 39, 1226–1232. [Google Scholar] [CrossRef] [PubMed]
- Werner, J.; Hägglund, M.; Waldén, M.; Ekstrand, J. Hip and groin timeloss injuries in professional football: A 15-year prospective analysis of 17,000 injuries in male professional footballers. Br. J. Sports Med. 2019, 53, 603–610. [Google Scholar]
- Pulici, L.; Certa, D.; Zago, M.; Volpi, P.; Esposito, F. Injury burden in professional European football (soccer): Systematic review, meta-analysis, and economic considerations. Am. J. Sports Med. 2023, 51, 1005–1017. [Google Scholar] [CrossRef] [PubMed]
- Schoffl, J.; Dooley, K.; Miller, P.; Miller, J.; Snodgrass, S.J. Factors associated with hip and groin pain in elite youth football players: A cohort study. Sports Med. Open 2021, 7, 97. [Google Scholar] [CrossRef] [PubMed]
- Desmyttere, G.; Gaudet, S.; Begon, M. Test–retest reliability of a hip strength assessment system in varsity soccer players. Phys. Ther. Sport 2019, 37, 138–143. [Google Scholar] [CrossRef]
- Holmich, P.; Thorborg, K.; Dehlendorff, C.; Krogsgaard, K.; Gluud, C. Incidence and clinical presentation of groin injuries in sub-elite male soccer. Br. J. Sports Med. 2014, 48, 1221–1226. [Google Scholar] [CrossRef]
- Engebretsen, A.H.; Myklebust, G.; Holme, I.; Engebretsen, L.; Bahr, R. Intrinsic risk factors for groin injuries among male soccer players: A prospective cohort study. Am. J. Sports Med. 2010, 38, 2051–2057. [Google Scholar] [CrossRef]
- O’Connor, F.; Falvey, É.; Comyns, T.; Richter, C.; King, E. Reliability and validity of common hip adduction strength measures: The ForceFrame strength testing system versus the sphygmomanometer. Phys. Ther. Sport 2022, 56, 58–64. [Google Scholar]
- Light, N.; Thorborg, K. The precision and torque production of common hip adductor squeeze tests used in elite football. J. Sci. Med. Sport 2016, 19, 888–892. [Google Scholar] [CrossRef]
- Aerts, F.; Sheets, H.; Anderson, C.; Bussie, N.; Hoskins, R.; Maninga, A.; Novak, E. Reliability and agreement of hand-held dynamometry using three standard rater test positions. Int. J. Sports Phys. Ther. 2025, 20, 253–262. [Google Scholar] [CrossRef] [PubMed]
- Crow, J.F.; Pearce, A.J.; Veale, J.P.; VanderWesthuizen, D.; Coburn, P.T.; Pizzari, T. Hip adductor muscle strength is reduced preceding and during the onset of groin pain in elite junior Australian football players. J. Sci. Med. Sport 2010, 13, 202–204. [Google Scholar] [CrossRef]
- Bahr, R. Why screening tests to predict injury do not work—And probably never will. Br. J. Sports Med. 2016, 50, 776–780. [Google Scholar] [CrossRef]
- Ryan, S.; Kempton, T.; Pacecca, E.; Coutts, A.J. Measurement properties of an adductor strength-assessment system in professional Australian footballers. Int. J. Sports Physiol. Perform. 2019, 14, 256–259. [Google Scholar] [CrossRef]
- Kottner, J.; Audige, L.; Brorson, S.; Donner, A.; Gajewski, B.J.; Hróbjartsson, A.; Roberts, C.; Shoukri, M.; Streiner, D.L. Guidelines for reporting reliability and agreement studies (GRRAS). Int. J. Nurs. Stud. 2011, 48, 661–671. [Google Scholar]
- Premier League. Elite Player Performance Plan (EPPP). Available online: https://www.premierleague.com/youth/EPPP (accessed on 5 May 2022).
- Gabbett, T.J.; Kennelly, S.; Sheehan, J.; Hawkins, R.; Milsom, J.; King, E.; Whiteley, R.; Ekstrand, J. If overuse injury is a ‘training load error’, should undertraining be viewed the same way? Br. J. Sports Med. 2016, 50, 1017–1018. [Google Scholar] [CrossRef]
- Ishøi, L.; Petersen, J.; Thornton, K.; DeLang, M. Maximal strength testing using the long-lever hip adduction squeeze test in youth elite football (soccer) players: A four-week reliability study. Int. J. Sports Phys. Ther. 2025, 20, 824–831. [Google Scholar] [CrossRef]
- Anderson, L.; Orme, P.; Di Michele, R.; Close, G.L.; Morgans, R.; Drust, B.; Morton, J.P. Quantification of training load during one-, two- and three-game week schedules in professional soccer players from the English Premier League. J. Sports Sci. 2016, 34, 1250–1259. [Google Scholar] [CrossRef]
- Thorborg, K.; Petersen, J.; Magnusson, S.P.; Hölmich, P. Clinical assessment of hip strength using a hand-held dynamometer is reliable. Scand. J. Med. Sci. Sports 2010, 20, 493–502. [Google Scholar] [CrossRef] [PubMed]
- Bartko, J. The intraclass correlation coefficient as a measure of reliability. Psychol. Rep. 1966, 19, 3–11. [Google Scholar] [CrossRef] [PubMed]
- Fulcher, M.L.; Hanna, C.M.; Elley, C.R. Reliability of handheld dynamometry in assessment of hip strength in adult male football players. J. Sci. Med. Sport 2010, 13, 80–84. [Google Scholar] [CrossRef] [PubMed]
- Dunne, C.; Callaway, A.J.; Thurston, J.; Williams, J.M. Validity, reliability, minimal detectable change, and methodological considerations for HHD and portable fixed frame isometric hip and groin strength testing: A comparison of unilateral and bilateral testing methods. Phys. Ther. Sport 2022, 57, 46–52. [Google Scholar] [CrossRef] [PubMed]
- Henry, F.M.; Smith, L.E. Simultaneous vs. separate bilateral muscular contractions in relation to neural overflow theory and neuromoter specificity. Res. Quarterly. Am. Assoc. Health Phys. Educ. Recreat. 1961, 32, 42–46. [Google Scholar] [CrossRef]
- Simoneau-Buessinger, E.; Leteneur, S.; Toumi, A.; Dessurne, A.; Gabrielli, F.; Barbier, F.; Jakobi, J.M. Bilateral strength deficit is not neural in origin; rather due to dynamometer mechanical configuration. PLoS ONE 2015, 10, e0145077. [Google Scholar] [CrossRef]
- Lloyd, R.S.; Oliver, J.L. Long-term athletic development—Part 1: A pathway for all youth 2015. Strength Cond. J. 2012, 29, 1439–1450. [Google Scholar] [CrossRef]


| Inclusion Criteria | Exclusion Criteria |
|---|---|
|
|
| Intra-Rater Reliability | ICC (95% CI) | SEM | SEM% | MDC | MDC% | CV% | LOA |
|---|---|---|---|---|---|---|---|
| HHD | 0.90 (0.82–0.95) | 12.3 | 4.8% | 34.2 | 13.6% | 5.5% | 11.75 |
| FFS | 0.85 (0.71–0.92) | 21.5 | 5.6% | 59.6 | 15.5% | 6.0% | 14.96 |
| Paired Test | Mean | SD | T | Sig. |
|---|---|---|---|---|
| HHD | −12.27 | 32.92 | −2.297 | 0.027 |
| FFS | −9.41 | 54.26 | −1.069 | 0.292 |
| Linear regression | Beta | T | Sig | |
| HHD | 0.003 | 0.017 | 0.987 | |
| FFS | 0.057 | −0.344 | 0.732 |
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Stefanakis, A.; Gore, S.; Hicks, C.; Mansfield, M.; Willett, M. Intra-Rater Reliability and Construct Validity of Hand-Held Dynamometry to Evaluate the Hip Adductor Squeeze Test in Elite Youth Football Players. Sports 2026, 14, 53. https://doi.org/10.3390/sports14020053
Stefanakis A, Gore S, Hicks C, Mansfield M, Willett M. Intra-Rater Reliability and Construct Validity of Hand-Held Dynamometry to Evaluate the Hip Adductor Squeeze Test in Elite Youth Football Players. Sports. 2026; 14(2):53. https://doi.org/10.3390/sports14020053
Chicago/Turabian StyleStefanakis, Alexandros, Shane Gore, Christopher Hicks, Michael Mansfield, and Matthew Willett. 2026. "Intra-Rater Reliability and Construct Validity of Hand-Held Dynamometry to Evaluate the Hip Adductor Squeeze Test in Elite Youth Football Players" Sports 14, no. 2: 53. https://doi.org/10.3390/sports14020053
APA StyleStefanakis, A., Gore, S., Hicks, C., Mansfield, M., & Willett, M. (2026). Intra-Rater Reliability and Construct Validity of Hand-Held Dynamometry to Evaluate the Hip Adductor Squeeze Test in Elite Youth Football Players. Sports, 14(2), 53. https://doi.org/10.3390/sports14020053

