Next Article in Journal
On the Relation between Friction Increase and Grease Thickener Entraining on a Border of Mixed EHL Lubrication
Previous Article in Journal
The Performance of SiO2 and TiO2 Nanoparticles as Lubricant Additives in Sunflower Oil
Previous Article in Special Issue
Liquid Crystals as Lubricants
 
 
Article
Peer-Review Record

Macroscopic Friction Studies of Alkylglucopyranosides as Additives for Water-Based Lubricants

by Wei Chen 1, Tobias Amann 2, Andreas Kailer 2 and Jürgen Rühe 1,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Reviewer 3: Anonymous
Submission received: 2 December 2019 / Revised: 31 December 2019 / Accepted: 3 January 2020 / Published: 16 January 2020
(This article belongs to the Special Issue Liquid Crystalline and Ionic Liquid Crystalline Lubricants)

Round 1

Reviewer 1 Report

This manuscript investigated the tribological performances of alkyl glucopyranoside as additives for water.

This manuscript fully explained the research background. The results were also interesting and suggested the applications under the low contact pressure (~1.2 MPa).

However, there are some questions to improve the quality of this investigation.

1) Wear volume

There is a photograph of the wear scar, but did you evaluate the amount of wear quantitatively?

2) Discussions

Is there any correlation with the evaluation of adsorption amount by using QCM etc?

3) References

If possible, add MDPI literature (such as Lubricants, Coatings, and Materials) to "References"

 

 

Author Response

see attachment

Author Response File: Author Response.docx

Reviewer 2 Report

The authors should address the following questions and comments:

Which are the specific applications for the lubricants proposed? Argue the requirements of those applications. How were the aqueous solutions prepared? A detailed description is required to reproducibility in other labs. Why was the ring-on-plate tribological test selected for the tribological evaluation? It is not representative for sliding bearings. How were the tribological test conditions selected and stated? How was the lubricant sample applied in the test? A test set-up schematic view should be provided to understand the lubrication technique employed. Figure 2 is not clear. I suggest indicating each curve with arrows or different vignettes for each lubricant sample results. It is not usual that mineral or synthetic oils exhibit non-newtonian behaviour. You are reporting that Optigear 32 oil presented a non-Newtonian behaviour. Is it typical for this lubricant?. Did you perform repetition rheological tests to confirm the behaviour discussed for all the samples? Wear rates are missing. Wear mechanisms are not enough to discuss wear behaviour. I suggest discussing what is the influence of having a non-Newtonian rheological behaviour (the case of most of aqueous solutions made) on COF and wear. Equations 1 and 2 comprises dynamic viscosities from Newtonian fluids, but the lubricants tested did not exhibit this behaviour. Why did you chose 1.4 mPa·s and 29.7 mPa·s as the viscosity for the 10 % and 40 % C8 solutions?. I think that the lambda model is not applicable for these lubricants.

Author Response

see attachment

Author Response File: Author Response.docx

Reviewer 3 Report

The authors investigated the lubrication performance of water-based lubricants containing glucopyranosides. The effects of concentration and alkyl chain length have been studied. The work here is interesting and certainly, will draw a lot of interest from researchers working on novel water-based lubricants. There are few questions need to be addressed:

In section 3.2, a low friction coefficient was achieved when the C8 concentration was higher than 20%. It can be observed that there is a ~250s of the running-in period before the low friction. Does it correlate with the tribofilm or adsorbed layer formation?

In Figure 6, can the author provide the images of the wear on counter surfaces? As well did the author conduct any chemical characterization on the wear scar to analyze the composition of tribofilms?

Author Response

see attachment

Author Response File: Author Response.docx

Round 2

Reviewer 2 Report

Tribological investigations involve both friction and wear studies. In this reviewed paper version, the authors do not add wear rates or volumes results and discussions. So, this paper is aimed to report and discuss only on friction coefficient and poor evidence of wear. The title should be changed to "Investigation of Improved friction coefficient of alkylglucopyranosides as additives for water"

 

Change the caption of figure 5. Replace "tribological behavior" by "Friction coefficient behavior". 

 

All the discussion sentences and figure captions refering to "tribological behavior" should be reviewed and changed to "Friction coefficient behavior" since the are supported only by COF results.

Author Response

See attachment.

Author Response File: Author Response.docx

Back to TopTop