Article

Symmetry-Oriented Design Optimization for Enhancing Fatigue Life of Marine Liquid Hydrogen Storage Tanks Under Asymmetric Sloshing Loads

1
School of Engineering, Shandong Xiandai University, Jinan 20288, China
2
Department of Mechanical Engineering, Hoseo University, Asan 31499, Republic of Korea
3
Virtual Structural Technology Co., Ltd., Asan 31499, Republic of Korea
4
School of Transportation, Ludong University, Yantai 264025, China
*
Authors to whom correspondence should be addressed.
Symmetry 2025, 17(9), 1497; https://doi.org/10.3390/sym17091497
Submission received: 30 July 2025 / Revised: 30 August 2025 / Accepted: 3 September 2025 / Published: 9 September 2025
(This article belongs to the Special Issue Symmetry in Power Systems and Thermal Engineering)

Abstract

Hydrogen fuel cells are gaining attention as an eco-friendly propulsion system for ships, but the structural safety of storage tanks, which store hydrogen at high pressure and supply it to the fuel cell, is a critical concern. Marine liquid hydrogen storage tanks, typically designed as rotationally symmetric structures, face challenges when subjected to asymmetric wave-induced sloshing loads that break geometric symmetry and induce localized stress concentrations. This study conducted a fluid–structure interaction (FSI) analysis of a rotationally symmetric liquid hydrogen storage tank for marine applications to evaluate the impact of asymmetric liquid sloshing induced by wave loads on the tank structure and propose symmetry-guided structural improvement measures to ensure fatigue life. Sensitivity analysis using the finite difference method (FDM) revealed the asymmetric influences of design variables on stress distribution: increasing the thickness of triangular mounts (T1) reduced stress 3.57 times more effectively than circular ring thickness (T2), highlighting a critical symmetry-breaking feature in support geometry. This approach enables rapid and effective design modifications without complex optimization simulations. The study demonstrates that restoring structural symmetry through targeted reinforcement is essential to mitigate fatigue failure caused by asymmetric loading.

1. Introduction

According to the United Nations’ Review of Maritime Transport published in 2023, the maritime transport sector accounts for over 80% of global trade volume and contributes approximately 3% of worldwide greenhouse gas emissions. As illustrated in Figure 1, the sector’s greenhouse gas emissions exhibited a notable increase of approximately 20% over the decade from 2012 to 2023. This upward trend underscores the growing environmental impact of maritime logistics despite ongoing efforts to enhance operational efficiency within the industry.
At the 70th session of the International Maritime Organization’s (IMO) Marine Environment Protection Committee (MEPC) held in October 2016, a regulatory measure was adopted to reduce the permissible sulfur content in ship fuel oil from 3.5% to 0.5%, effective 1 January 2020. Furthermore, the revised IMO Greenhouse Gas (GHG) Reduction Strategy adopted in July 2023 established ambitious targets: a 20% improvement in the energy efficiency of international shipping by 2030, relative to 2008 levels, and a 70% reduction in maritime GHG emissions by 2040 compared to 2008 [2]. These mandates underscore the urgency for the maritime sector to rapidly decarbonize. Hydrogen has emerged as a leading candidate for achieving these goals, offering zero greenhouse gas emissions, energy conversion efficiencies nearing 80% in fuel cell applications, and advantages such as operational flexibility, zero local pollution, and diverse production pathways [3,4,5].
Hydrogen’s high energy density—approximately three times that of gasoline—and its wide flammability range (4–75% concentration in air) pose significant safety risks. A stark example is the June 2019 explosion at a hydrogen refueling station in Sandvika, Oslo, Norway (Figure 2). The incident injured two individuals and disrupted regional hydrogen infrastructure. Investigations by safety consultancy Gexcon traced the cause to hydrogen leakage from an improperly assembled plug screw, with ignition triggered by friction from gravel on the station’s ground surface [6].
Another case, illustrated in Figure 3, involves a 2021 tube trailer accident. A tire fire caused overheating of the hydrogen storage vessel, prompting the safety valve to activate and release hydrogen over 30 min. This resulted in flames reaching 10–20 m in height. However, rapid emergency containment measures prevented catastrophic escalation [7].
Marine hydrogen storage systems must ensure operational safety under prolonged maritime conditions, including vessel vibrations, unpredictable oceanic environments, and internal pressure fluctuations caused by liquid hydrogen evaporation and sloshing. Robust design standards are essential to withstand these dynamic stresses. Additionally, fatigue life analysis is critical to predict the structural integrity of storage tanks under cyclic loading and to evaluate their long-term durability in harsh maritime settings. Such studies are vital to address the compounded effects of mechanical wear, environmental corrosion, and pressure variations inherent to hydrogen storage at sea.
Hydrogen has been utilized across various industries for decades; however, its expanding application in fuel cells has recently heightened safety concerns [8]. To ensure its safe deployment, two critical dimensions must be addressed. First, proactive risk mitigation through accident prevention is essential. This includes rigorous protocols such as regular pressure testing and precision inspections of storage tanks to identify latent defects or vulnerabilities. Second, minimizing the consequences of potential accidents is equally vital. For instance, material brittleness under cryogenic conditions and unanticipated environmental shifts—factors often overlooked in initial design phases—can introduce unforeseen risks of failure or leakage [9]. Significant research and development efforts have been dedicated to enhancing the safety of hydrogen storage tanks, leading to advancements in material selection, thermal stress management, and structural integrity under static pressure. Studies on collision simulations for vehicle-mounted tanks at varying speeds have also provided critical insights for improving marine storage tank design. Han et al. [10] conducted a finite element analysis of a Type III 70 MPa hydrogen storage tank for vehicles, focusing on failure mechanisms under low-speed collisions. Using a layered modeling approach, they evaluated the tank’s performance under internal pressure (70 MPa) and impact loading. By applying the Hashin failure criterion, they confirmed the tank’s post-collision safety and investigated failure modes across collision speeds, ultimately validating the tank’s potential for reuse after low-impact events. Jang Dae-jun et al. [11] emphasized that liquid hydrogen (LH2; After that, they are all abbreviated as LH2) storage tanks must withstand loads from insulation systems (1 atm), vapor pressure, and hydrostatic pressure. For marine applications, they highlighted the necessity of accounting for dynamic loads and thermally induced stresses from temperature gradients. Kwak Hyo-Seo [12] performed a thermo-structural coupling analysis of an LH2 tank, identifying stress concentration vulnerabilities in the dome section compared to the cylindrical body. Ogata [13] observed that 304 L stainless steel exposed to 10 bar gaseous hydrogen exhibited reduced elongation and cross-sectional area at various temperatures, though the effects were less severe than those under high-pressure hydrogen. Consequently, 316 L stainless steel was selected as the material for the liquid hydrogen storage tank in this study. While sloshing research for marine tanks has predominantly focused on ambient-temperature fluids or cryogenic liquefied natural gas (LNG), studies on liquid hydrogen (LH2) sloshing remain limited. However, insights from aerospace and automotive sectors offer valuable references. Lacapere [14] conducted sloshing experiments using cryogenic liquid nitrogen and oxygen, concluding that pressure drops in sealed containers arise primarily from interfacial heat and mass transfer during sloshing. Moran et al. [15] investigated LH2 sloshing in a 62 ft3 (1750 L) spherical tank for the National Aero-Space Plane (NASP) project, adjusting parameters such as sloshing frequency, amplitude, pressurization type, ramp pressure, and vapor space volume. Their findings revealed that sloshing near the tank’s resonant frequency could induce severe vapor space collapse, necessitating caution in design. Berglund et al. [16] numerically analyzed LH2 sloshing in a two-stage aircraft tank during coast phases, demonstrating that excessive sloshing could destabilize propulsion systems. Sherif et al. [17] highlighted that fluid sloshing in automotive LH2 tanks converts kinetic energy into thermal energy, accelerating hydrogen evaporation rates. Although extensive studies have explored hydrodynamic behavior and thermal interactions (e.g., pressure drops and heat exchange between subcooled liquid and warm vapor) in LH2 sloshing, limited attention has been paid to structural defects or fatigue damage caused by sloshing under wave-induced external loads in marine environments. This gap underscores the need for further research to address the unique challenges of hydrogen storage in maritime applications.
Maritime vessels operating on long-distance voyages face inherent risks: safety incidents at sea can escalate into complex rescue scenarios, jeopardizing both crew lives and cargo. Consequently, ensuring the structural integrity of onboard hydrogen storage tanks is a critical priority in advancing hydrogen-powered shipping. Ships are continuously subjected to dynamic external loads, such as wave-induced forces, which induce hull vibrations. These vibrations inevitably propagate to internal hydrogen storage tanks, compromising their durability and potentially leading to premature failure—a risk that could result in tanks failing to meet their designed operational lifespan.
This study aims to address these challenges by conducting a fluid–structure interaction (FSI) analysis of a marine-grade liquid hydrogen (LH2) storage tank. The focus is on evaluating the effects of wave-induced sloshing dynamics on the tank’s structural behavior during navigation and predicting its fatigue life under cyclic loading. By integrating hydrodynamic and structural simulations, the research seeks to establish safety benchmarks and inform design optimizations to enhance the reliability of hydrogen storage systems in maritime environments.
Structurally, marine liquid hydrogen tanks are predominantly cylindrical vessels with rotational symmetry—a design chosen for uniform stress distribution under ideal conditions. However, this inherent symmetry is compromised during navigation due to asymmetric wave-induced sloshing loads. The resulting asymmetric fluid–structure interactions generate localized stress concentrations that accelerate fatigue failure, creating a fundamental conflict between geometric symmetry and operational asymmetry. This study addresses this symmetry-asymmetry dichotomy through sensitivity-driven design optimization. Although the existing research on liquefied natural gas and aerospace LH2 storage tanks provides a valuable foundation, the operating conditions for Marine LH2 storage are significantly different. Compared with LNG, the vapor of liquid hydrogen is extremely light, diffuses very quickly, has a wider explosive limit range (4–75%), and has a very low ignition energy. After leakage, it is more likely to be accidentally ignited, posing a greater safety challenge. Due to the influence of waves, Marine liquid hydrogen storage tanks are constantly subjected to shaking loads. Most of the liquid hydrogen storage tanks used in aerospace are for single use or short-term repeated use (such as in space shuttles). The design life is very short (from a few minutes to several days). However, ships are required to have a service life of up to 20 to 30 years, during which they have to endure the corrosion of the Marine environment, repeated loading and unloading cycles, and long-term temperature fatigue. Maintainability and detectability are key design considerations.

2. System Configuration of Hydrogen Fuel Cell Vessels and 3D Modeling of Hydrogen Storage Tanks

2.1. Hydrogen Fuel Cell Ship System Configuration

A hydrogen fuel cell ship is a vessel that generates electricity by supplying hydrogen to fuel cells and navigates by driving propulsion motors with this electricity. Figure 4 briefly illustrates the main systems of a hydrogen fuel cell ship. Such ships can be broadly categorized into three major systems: the marine hydrogen fuel storage and supply system, the hydrogen fuel cell—ESS (Energy Storage System) system, and the propulsion and control system.
The marine hydrogen fuel storage and supply system is further subdivided into a fuel storage system and a fuel supply system. Fuel storage is categorized into high—pressure storage tanks and liquid storage tanks. The object of this study is a liquid storage tank, with the research primarily focusing on thermal insulation materials and structural technologies for maintaining liquid hydrogen in an ultra—low—temperature environment. However, fundamental support is required for aspects such as the design of the inner and outer wall structures of the storage tank, the design of reinforcing materials, and the design of support structures, similar to those of high—pressure storage tanks.

2.2. Three-Dimensional Models and Materials of Hydrogen Storage Tanks

According to China’s pressure vessel standard GB150-2011 [19] (this standard is based on international standards such as ISO and IMO), the thickness design of pressure vessels must consider the influence of operating pressure. The thickness calculation formula provided in this standard is shown as Equation (1):
t = p · D 2 · σ / n p
t : Design Thickness of the Inner Storage Tank
p : Design Working Pressure (p = 3 MPa)
D : Outer Diameter of the Inner Storage Tank (D = 800 mm)
σ : Allowable Stress (σ = 200 MPa)
n : Design Safety Factor (n = 1.5)
The material intended for use in the internal tank is 316 L Stainless Steel, with an allowable stress of 200 MPa. Through calculations, the initial design thickness (t) of the internal storage tank was determined to be 9.1 mm. The design basis pressure considering working pressure is 3 MPa. The detailed specifications of the 3D model used in the analysis are presented in Table 1, and the completed 3D model is shown in Figure 5.
The hydrogen storage tank is secured to a platform using three circular support rings, with the bottom of the platform fixed to the ship. The tank section is divided into an internal tank and an external tank, and between the internal and external tanks, cylindrical supports with a diameter of 100 mm and a height of 46 mm are installed for structural support. These supports are positioned at 90° intervals, with four supports on each side (left and right), totaling eight supports in total. Their locations correspond to the areas where the platform’s circular support rings are fastened.
Special materials are required for storing liquid hydrogen at extremely low temperatures (20 K). Materials used in storage tanks must exhibit adaptability to liquid hydrogen, resistance to hydrogen embrittlement, mechanical properties, and thermophysical properties at cryogenic temperatures [20]. In this study, 316 L stainless steel was selected as the storage tank material considering its application in marine environments. For 316 L stainless steel, higher molybdenum (Mo) content correlates with greater resistance to chloride ion corrosion [21].
Generally, cryogenic storage tanks for liquid hydrogen utilize thermal insulation materials between the inner and outer tanks to maintain extremely low temperatures [22]. Perlite powder is commonly employed due to its economic efficiency and superior thermal insulation properties. However, as its relatively low mechanical properties have minimal impact on the analysis results, this study did not consider this material [23]. The supports between the inner and outer tanks were constructed from glass fiber-reinforced plastic (GFRP). Steel was used for the circular fixing devices and platforms. The main mechanical property values of the materials used in the analysis are listed in Table 2, Table 3 and Table 4.
The cylindrical tank geometry (Figure 5) exhibits rotational symmetry with respect to its central axis, theoretically enabling uniform stress distribution under axisymmetric loads. Support structures are arranged at 90° intervals to preserve circumferential symmetry. However, the triangular mounts on circular support rings introduce localized asymmetry, creating potential stress risers when symmetry-breaking sloshing occurs.
To conduct fatigue analysis, the fatigue life curves (S-N curves) of each material are required. Although obtaining fatigue life curves necessitates fabricating actual material specimens and performing fatigue tests, which are costly and time-consuming, this study utilized ANSYS 2021 R1 Workbench Material Tools to calculate and utilize the fatigue life curves by applying the mechanical property data and fatigue data of each material [24]. The fatigue life curve for the platform material, Steel, is shown in Figure 6.
The fatigue life curve for 316 Stainless Steel, the material of the liquid hydrogen storage tank, is depicted in Figure 7. Fatigue data measured at −50 °C (223 K), as presented in the research results by San et al. [28], were employed. The rationale for using the fatigue data at −50 °C is based on the following research findings.
According to recent research by Singh et al., fatigue tests on 316 L stainless steel confirmed that material strength and fatigue life at extremely low temperatures of −258 °C (15 K) are improved compared to room temperature, as shown in Figure 8 The study anticipated that 316 L stainless steel would become a crucial material in space exploration and energy storage fields [29]. Additionally, San et al.’s research, through fatigue tests on 316 L stainless steel at −50 °C (223 K) and room temperature (as depicted in Figure 9), demonstrated that fatigue life is enhanced in low-temperature (−50 °C) environments [28]. These studies collectively indicate that the fatigue life of 316 L stainless steel is higher in low-temperature environments than in room-temperature conditions.
In Wang et al.’s study, as shown in Figure 10, it was confirmed that when liquid hydrogen is discharged, exposure to high-temperature gas causes the temperature of the storage tank to gradually increase, with a very wide range of temperature variation. The results showed that the temperature near the discharge part of the tank’s inner wall increased to approximately −53 °C (220 K) [30]. As shown in Figure 11, Jeong Sujin et al. investigated temperature and pressure changes according to the thickness of the insulation material in liquid hydrogen storage tanks, confirming that the average temperature of the entire inner wall increases to approximately −110 °C depending on the insulation thickness [31]. Additionally, according to Clause 4.3.2 of the international standard ISO 13985:2006 for liquid hydrogen storage tanks, the tanks must be able to withstand ambient temperatures ranging from −40 °C to 85 °C [32].
Therefore, although 316 L stainless steel exhibits improved fatigue life in extremely low-temperature environments below −253 °C (where hydrogen remains in a liquid state), fatigue life predictions were conducted using fatigue data at −50 °C (223 K)—a temperature with shorter fatigue life—while considering actual operational environments such as temperature changes in the storage tank’s inner wall during hydrogen cooling and discharge.

3. Fluid–Structure Interaction Analysis and Fatigue Analysis of Hydrogen Storage Tanks

In this study, fluid–structure interaction (FSI) analysis was employed because the pressure changes caused by the sloshing of liquid hydrogen directly affect the storage tank. First, the sloshing behavior of liquid hydrogen was analyzed through fluid dynamics analysis, and the time-dependent pressure changes inside the tank were derived. ANSYS, used for the analysis, utilizes the finite volume method for fluid dynamics analysis, so a computational fluid dynamics (CFD) model of the internal tank requiring fluid behavior analysis was modeled and analyzed.
Additionally, to analyze the effects of fluid sloshing within the tank on the structure, the time-dependent pressure changes results derived from the fluid analysis were utilized in the dynamic response analysis required for structural strength analysis. Unlike fluid analysis, structural analysis employs the finite element method (FEM). Therefore, finite element analysis models were developed for the tank, platform, supports, and other components requiring strength analysis, with physical data from the fluid domain connected to the structural boundaries to perform the analysis.

3.1. Computational Fluid Dynamics (CFD) Model and Boundary Conditions and Loading Conditions

The computational fluid dynamics (CFD) model of the internal tank for examining the pressure distribution caused by liquid sloshing in the internal tank is shown in Figure 12. It consists of 459,781 nodes, 166,812 cells, and 765,876 faces.
For safety reasons, liquid hydrogen storage tanks are operated with an initial filling level of 60% rather than 100%. As shown in Figure 13, the boundary conditions for the fluid analysis of the internal storage tank were set as fixed walls with no heat transfer to the external environment. Specifically, the lower 60% region was defined as the liquid phase, and the remaining 40% region was designated as the gas phase. The internal temperature of the tank was set to −253 °C.
Additionally, the loading condition as shown in Figure 14 was applied in the Z-axis direction (see Figure 13) at the center of mass of the tank. A 6 g acceleration was imposed for a duration of 400 ms and then removed, enabling an investigation of pressure changes as liquid hydrogen sloshes due to inertial effects.

3.2. Fluid Analysis Results

As shown in Figure 15 Due to the excitation (acceleration), after liquid hydrogen collides with the right wall, it does not immediately rebound but overturns toward the top of the tank. When the acceleration is removed after 400 ms, part of the liquid hydrogen flows along the left wall and collides with the liquid hydrogen at the bottom. Thereafter, due to inertia, the liquid hydrogen sloshes freely, causing strong mixing between the gas and liquid phases. At 1.0 s, under the influence of gravitational acceleration, the liquid hydrogen gradually separates from the gas and returns to the tank bottom. During the falling process, bubbles are clearly observed to form within the liquid hydrogen. After 2.0 s, the liquid hydrogen gradually settles to the tank bottom and continues oscillatory motion due to inertia, but the amplitude of sloshing decreases as the kinetic energy of the liquid hydrogen diminishes, eventually returning to a stable state. At this point, a reduction in internal bubbles is also confirmed.
The fluid analysis results indicate that when the tank undergoes significant excitation, liquid hydrogen sloshes with large amplitude, and in severe cases, it can lead to a situation where the entire tank bottom is occupied by gas for a certain period. Additionally, during the process of liquid hydrogen returning to the bottom, it may entrain a large amount of gas, resulting in numerous bubbles within the liquid hydrogen. These bubbles can negatively affect the operation of liquid hydrogen pumps and may lead to risks due to incomplete fuel supply during ship navigation.
Figure 16 illustrates the pressure changes within the tank caused by liquid sloshing during the sloshing process. Initially, the pressure remains stable at the design working pressure of 3 MPa without any variation. From 0.1 s onward, as liquid hydrogen begins to slosh and collides with the right dome, the maximum pressure is observed to increase by 7.86 kPa. This maximum pressure increase is localized to a small region at the upper right corner.
At 0.2 s, the pressure changes gradually propagate to the entire dome of the tank. Meanwhile, partial pressure reduction occurs due to vapor condensation caused by gas–liquid mixing. By 0.3 s, most of the gas is surrounded by liquid, leading to a general pressure increase throughout the tank. However, the primary pressure increase remains concentrated in the right dome area subjected to acceleration excitation. Although the pressure magnitude does not decrease from the 7.86 kPa increase, the spatial extent of the high-pressure region is observed to shrink compared to 0.2 s. From 0.4 s onward, as the acceleration is removed, the sloshing-induced pressure gradually decreases but does not fully return to a stable state, fluctuating between 21.4 Pa and 1.002 kPa. Additionally, while the distribution of pressure-increased regions continues to change with the movement of liquid hydrogen, the pressure values themselves exhibit no significant variations.
The formation of high-stress and high-pressure concentrations is a direct consequence of the interaction between the sloshing fluid dynamics and the specific geometric features of the tank. As illustrated in Figure 15 and Figure 16, the initial high-impact pressure peak (7.86 kPa increase) occurs locally at the upper right dome due to the impulsive load generated when liquid hydrogen, driven by acceleration, collides with the high-curvature geometry of the dome. This geometric configuration causes a rapid change in fluid momentum, concentrating stress in this region. Subsequently, the pressure wave propagates across the dome surface, and the general pressure rise throughout the tank is exacerbated by the confinement of vapor space as it becomes surrounded by liquid. Following the removal of acceleration, the continued sloshing generates dynamic fluctuating pressures on the tank walls, particularly during the drain-back process where gas-entrained liquid impacts broader areas like the left wall and bottom. These sustained hydrodynamic loads, combined with the structural response at geometric discontinuities (e.g., the dome-cylinder junction), are the primary physical mechanisms leading to the observed stress concentrations. This analysis underscores that both the local impulsive loads on high-curvature surfaces and the global dynamic pressures from large-scale sloshing are critical for structural design considerations.

3.3. Structural Interaction Analysis Using Fluid Analysis Results

3.3.1. Finite Element Analysis Model, Boundary Conditions, and Loading Conditions

The finite element model of the hydrogen storage tank used for finite element analysis is shown in Figure 17. To apply the pressure changes in the internal tank derived from fluid analysis as boundary conditions (pressure loads) in the structural analysis of the internal tank, the mesh quality of the boundary surface (in this study, the internal tank) is critical. The Matched Mesh option provided by ANSYS was used to ensure that the nodes of the internal tank (the boundary surface) directly coincide with those from the fluid analysis results. The elements used were ‘Shell 181’ and ‘Solid 185’ provided by ANSYS, with a total of 67,562 nodes and 65,765 elements used for modeling.
To apply the time-dependent pressure distribution caused by liquid sloshing to structural analysis, time-series pressure change data for the entire internal tank from fluid analysis were extracted, and boundary conditions were applied in the direction of the right dome across the entire surface of the internal tank, as shown in Figure 18. Since the internal pressure reaches its maximum value at 0.3 s, structural displacements and stresses are expected to be highest around 0.3 s. Gravitational acceleration was applied to account for the effect of self-weight, and finite element analysis was performed by fixing the bottom portion where the platform is anchored to the ship. The masses of the hydrogen storage tank and platform are 768.51 kg and 153.72 kg, respectively.

3.3.2. Displacement and Stress Analysis Results

Figure 19 shows the displacement analysis results of the structure obtained through fluid–structure interaction (FSI) analysis. The maximum displacement occurred at 0.4 s, calculated as 0.766 mm in the internal storage tank of Figure 19. This maximum displacement occurred in the right dome section of the tank, which is the direction in which the liquid is sloshing.
The stress results of the fluid–structure interaction (FSI) analysis are shown in Figure 18. High stress distribution is observed in the direction of liquid hydrogen sloshing within the internal storage tank, with the maximum stress calculated as 262.58 MPa at 0.4 s in the dome section of the internal storage tank in Figure 20a. Since the allowable stress of the internal storage tank’s material, 316 L Stainless Steel, is only 200 Mpa, this may have a significant impact on operational safety.
Additionally, as shown in Figure 20b, high stress of 253.03 Mpa occurred in the triangular amounts of the circular fixing devices used for tank connection on the platform.
Sloshing of the liquid within a liquid hydrogen storage tank can induce stress concentration in specific areas, particularly in regions with weaker structural strength. If repeated pressure increases occur inside the tank due to liquid hydrogen vibrations, fatigue will accumulate. Although 316 L Stainless Steel exhibits excellent durability, repeated stress fluctuations can impact the fatigue life of the structure. Hydrogen storage tanks for marine applications must maintain stability amid hull vibrations and irregular operational environments. If continuous pressure changes and stresses arise in the storage tank due to wave loads and ship movements, fatigue damage to the tank may occur. Therefore, it is critical to ensure the tank’s durability through fatigue life assessment.
Maximum stress (262.58 MPa) occurred at the right dome—precisely where sloshing impacts broke structural symmetry. Crucially, the triangular mounts (Figure 20b) exhibited 253.03 MPa stress despite symmetric arrangement, revealing that geometric discontinuities amplify asymmetric loading effects. This demonstrates how local symmetry-breaking features dominate failure initiation under asymmetric operational conditions.

3.4. Fatigue Analysis of Hydrogen Storage Tank

3.4.1. Fatigue Analysis Condition

According to the “Rules for Natural Gas as Fuel for Ships” of the China Classification Society (CCS), the fatigue life must be at least 106 cycles when subjected to wave loads [33]. The stress variation from when liquid hydrogen experiences acceleration due to wave loads until the sloshing phenomenon ceases was defined as 1 cycle, and the fatigue life under repeated application of this stress history was predicted.
To calculate fatigue life, the stress history was first modified to Zero Mean Stress using the Goodman mean stress equation (Equation (2)). Subsequently, the fatigue life was calculated using Miner’s cumulative damage rule (Equation (3)) and the material’s fatigue life diagram.
σ a σ f + σ m σ u = 1
σ a : Alternating Stress Amplitude
σ m : Mean Stress
σ f : Endurance Limit
σ u : Ultimate Tensile Strength
D = i = 1 n n i N i
D: Cumulative Damage (Failure Occurs when D 1 )
n i : Number of Cycles applied at Stress Level i
N i : Number of Cycles to Failure at Stress Level i
n : Total Number of Stress Level i

3.4.2. Fatigue Analysis Results

The fatigue analysis results of the storage tank structure caused by liquid sloshing inside the hydrogen storage tank in this study are shown in Table 5. For the external tank, the fatigue life results indicated a minimum life of 108 cycles, which was calculated as infinite life. However, in the triangular mounts of the circular fixing device connecting the platform and the tank in Figure 21a, the fatigue life was 129,670 cycles, failing to meet the target life of 106 cycles. Additionally, the internal storage tank in Figure 21b showed the lowest fatigue life of 92,757 cycles, predicting that it would be the first to fail when subjected to cumulative repeated stresses.
Therefore, since the triangular mounts of the circular fixing device in Figure 21a and the internal tank in Figure 21b do not meet the target life, structural improvements are necessary to reduce stresses and ensure fatigue life. To decrease the stress in each structure, the dimensions (thickness) of their constituent components must be efficiently increased. To this end, design variables requiring structural reinforcement were selected, and sensitivity analysis was performed.

4. Sensitivity Analysis and Design Improvement of Design Parameters Affecting Fatigue Life

4.1. Selection of Design Parameters for Sensitivity Analysis

To improve the structural design, sensitivity analysis was performed by selecting design variables for the circular fixing devices and internal tanks where high stress occurred, as shown in Figure 22 Sensitivity refers to the weight that each design variable exerts on functions such as stress and displacement. For the circular fixing devices, the thickness of the triangular mount (T1) and the thickness of the circular ring part (T2) were selected as design variables, while for the internal storage tank, the thickness of the storage tank (T3) and the internal diameter (D1) were chosen as design variables. The sensitivity of the four design variables was analyzed to identify those with a clear stress reduction effect during design modifications, which will be used for design improvement.

4.2. Sensitivity Analysis Using Finite Difference Method

Sensitivity is used to determine the degree of influence of each design variable on a function, which can be calculated using partial differential equations. However, for actual structures such as marine liquid hydrogen storage tanks, since the function of the structure cannot be defined by an equation, the sensitivity was calculated using the finite difference method as shown in Equation (4).
σ m t i σ m t i
σ m : Maximum Stress
t i : Thickness (or Size) of Design Variables
In this paper, sensitivity calculations were performed by increasing the design variable ti to minimize the structural stress. Therefore, the denominator ∆t always yields a positive (+) result, and the sign of the sensitivity is determined by the result of the numerator. If the stress decreases after design improvement, the numerator will yield a negative (−) result, leading to a negative final sensitivity calculation. Thus, to reduce the objective function of maximum stress, a (−) sensitivity must be selected. The range of ∆ti was set to 0.001 mm to ensure the reliability of sensitivity analysis using the finite difference method. The detailed sensitivity results calculated by the finite difference method are shown in Table 6, and their schematic representation is illustrated in Figure 23.
Sensitivity results demonstrate asymmetric influence of design variables: T1 (triangular mount thickness) showed −50 sensitivity, while T2 (ring thickness) only −14—a 3.57-fold difference. This asymmetry correlates directly with geometric features: the triangular mounts’ sharp angles break rotational symmetry, making them disproportionately critical to stress reduction. Such asymmetric sensitivity necessitates symmetry-aware reinforcement prioritization.

4.3. Propose Improvement Plans

Using the sensitivity analysis results, design improvements were conducted by varying the triangular mount of the circular fixing device (design variable T1) and the thickness of the internal storage tank (design variable T3), as shown in Figure 24. Through iterative adjustments until the target fatigue life (106 Cycles) was achieved, the thickness of T1 increased by 55.16%, changing from the initial 7.62 mm to 11.823 mm, while T3 increased by 32.1%, from 9.1 mm to 12.021 mm. The dynamic response analysis results and fatigue life results for each component after design improvement are presented in Figure 25 and Figure 26.

5. Result

This study analyzed the behavior of internal pressure caused by sloshing of liquid hydrogen in a hydrogen storage tank and confirmed that the pressure increases by approximately 7.86 kPa above the constant pressure (design reference pressure) of 3 MPa in the tank during sloshing. This exceeds the design pressure of the hydrogen storage tank, indicating a potential impact on the structural safety of the storage tank. Through fluid–structure interaction analysis using time-dependent pressure changes in the internal tank, the stress and fatigue life of the structure were evaluated. It was found that some components failed to meet the fatigue life requirement of 106 cycles specified by the Chinese Classification Society. Therefore, sensitivity analysis was performed to identify design variables with significant stress reduction effects even under small changes, guiding structural design improvements. The comparison of weight changes, stress, and fatigue life before and after design improvement is shown in Table 7. Compared with the initial model, the weight of the storage tank increased by approximately 15%, while the fatigue life increased by approximately 1315.5%. Additionally, the maximum stresses in the triangular mounts of the circular fixing device for connecting the internal storage tank and the platform tank were reduced to 191.12 MPa and 186.83 MPa, respectively.

6. Conclusions

This study resolves the conflict between geometric symmetry and operational asymmetry in marine LH2 tanks through sensitivity-guided optimization. In this study, fluid–structure interaction analysis of a marine liquid hydrogen storage tank was conducted to analyze the effects of wave-induced liquid sloshing on structural components and propose structural improvement measures to ensure fatigue life. Liquid sloshing caused pressure fluctuations inside the tank, leading to high stresses in the internal and external structures of the hydrogen storage tank. These stresses negatively impacted fatigue life, necessitating structural modifications to meet the target service life.
For efficient structural improvement, sensitivity analysis results using the finite difference method were applied to guide design modifications. In practical industrial applications, it is often impossible to express structural functions as equations incorporating design variables. Therefore, as demonstrated in this study, using sensitivity results for each design variable via the finite difference method enables rapid and efficient design improvements, serving as an alternative to optimization simulations that require significant time and expertise.
In conclusion, this study confirms the necessity of analyzing dynamic behaviors under various external conditions and ensuring safety during the design phase of liquid hydrogen storage tanks. In particular, pre-ensuring fatigue life is critical for long-term stable operation in irregular marine environments. The findings of this research are expected to provide practical guidance for structural design and fatigue life improvement of liquid hydrogen storage tanks.
Although this study provides valuable insights into the fatigue life analysis and structural optimization of marine liquid hydrogen storage tanks, there are still several limitations that need to be further explored in subsequent research. Firstly, the fatigue life prediction is based on the S-N curve at −50 °C. Although relevant studies have been cited to indicate that low temperatures can enhance the fatigue performance of 316 L stainless steel, and the possible increase in the wall temperature of actual storage tanks has been taken into account, it still does not fully reflect the material behavior in the extreme low-temperature environment of liquid hydrogen (−253 °C). Secondly, the load conditions are relatively simplified, only considering the impact acceleration in a single direction, and do not cover the complex working conditions such as multi-directional wave excitation, resonant sway and thermal cycling in the actual Marine environment. This study relies entirely on numerical simulation, and the reliability of the simulation results has not yet been verified through experiments. Meanwhile, only one type of tank geometry and material combination was analyzed, and the influences of different support forms, material types or tank shapes were not compared. These limitations have pointed out directions for subsequent research, including conducting full-temperature range fatigue tests, multi-physics field coupling simulations, and multi-parameter optimization comparisons, etc., to further enhance the design reliability and safety of liquid hydrogen storage tanks in real marine environments.

Author Contributions

Conceptualization, J.-Q.L., M.G. and S.K.; Data curation, H.X.; Formal analysis, H.X.; Investigation, H.X.; Methodology, J.-Q.L., M.G. and S.K.; Project administration, J.-Q.L., M.G. and S.K.; Resources, J.-Q.L., M.G. and S.K.; Software, H.X.; Supervision, H.X.; Validation, J.-Q.L., M.G. and S.K.; Writing—original draft, H.X.; Writing—review and editing, J.-Q.L., M.G. and S.K. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by Ludong University (No.: 210-20220035).

Data Availability Statement

Data is contained within the article.

Acknowledgments

This research is also the result of receiving the support for the 2025 provincial college student’s innovation and entrepreneurship training program project, China.

Conflicts of Interest

Author ManSoo Koh was employed by the Virtual Structural Technology Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

References

  1. UN. Review of Maritime Transport; UNCTAD: Geneva, Switzerland, 2023; p. 26. [Google Scholar]
  2. Bilgili, L.; Ölçer, A.I. IMO 2023 strategy—Where are we and what’s next? Mar. Policy 2024, 160, 105479. [Google Scholar] [CrossRef]
  3. Roh, G. Development trends of hydrogen fuel cell ships. Trans. Korean Inst. Electr. Eng. 2020, 24, 37–44. Available online: https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=JAKO202015358667250 (accessed on 15 October 2024).
  4. Romm, J.J. The Hype About Hydrogen: Fact and Fiction in the Race to Save the Climate; Island Press: Washington, DC, USA, 2010; p. 46. [Google Scholar]
  5. Özsarı, İ. Trend analysis and evaluation of hydrogen energy and hydrogen storage research. Energy Storage 2023, 5, e471. [Google Scholar] [CrossRef]
  6. Gexcon. Root Cause of the Sandvika Hydrogen Station Explosion in Norway. Gexcon. 4 July 2019. Available online: https://www.gexcon.com/china/news/%E6%8C%AA%E5%A8%81Sandvika%E5%8A%A0%E6%B0%A2%E7%AB%99%E7%88%86%E7%82%B8%E4%BA%8B%E6%95%85%E6%A0%B9%E6%9C%AC%E5%8E%9F%E5%9B%A0/619/en (accessed on 15 October 2024).
  7. Seong, J.K. Hydrogen Tube Trailer Fire on the Highway. Monthly Hydrogen Economy. 30 December 2021. Available online: https://www.h2news.kr/news/articleView.html?idxno=9491 (accessed on 15 October 2024).
  8. Lobato, J.; Canizares, P.; Rodrigo, M.; Saez, C.; Linares, J. A comparison of hydrogen cloud explosion models and the study of the vulnerability of the damage caused by an explosion of H2. Int. J. Hydrogen Energy 2006, 31, 1780–1790. [Google Scholar] [CrossRef]
  9. Fischer, M. Safety aspects of hydrogen combustion in hydrogen energy-systems. Int. J. Hydrogen Energy 1986, 11, 593–601. [Google Scholar] [CrossRef]
  10. Han, M.-G.; Chang, S.-H. Evaluation of structural integrity of Type-III hydrogen pressure vessel under low-velocity car-to-car collision using finite element analysis. Compos. Struct. 2016, 148, 198–206. [Google Scholar] [CrossRef]
  11. Jang, D.J.; Kim, J.U.; Park, H.J. Development of liquefied hydrogen (LH2) storage tanks and safety standards. Supercond. Cryog. 2020, 22, 4–8. [Google Scholar]
  12. Kwak, H.S. Thermal-Structural Coupled Analysis of Liquid Hydrogen Tank Varying Head Shape. J. Korean Soc. Mech. Technol. 2023, 25, 999–1004. [Google Scholar] [CrossRef]
  13. Ogata, T. Simple Mechanical Testing Method to Evaluate Influence of High Pressure Hydrogen Gas. In Proceedings of the ASME 2018 Pressure Vessels and Piping Conference—PVP 2018, Prague, Czech Republic, 15–18 July 2018. [Google Scholar] [CrossRef]
  14. Lacapere, J.; Vieille, B.; Legrand, B. Experimental and numerical results of sloshing with cryogenic fluids. Prog. Propuls. Phys. 2009, 1, 267–278. [Google Scholar] [CrossRef]
  15. Mora, M.E.; McNelis, N.B.; Kudlac, M.T.; Haberbusch, M.S.; Satornino, G.A. Experimental results of hydrogen slosh in a 62 cubic foot (1750 liter) tank. In Proceedings of the 30th Joint Propulsion Conference cosponsored by AIAA, ASME, SAE, and ASEE, Indianapolis, IN, USA, 27–29 June 1994. [Google Scholar] [CrossRef]
  16. Berglund, M.D.; Bassett, C.E.; Kelso, J.M.; Mishic, J.; Schrage, D. The Boeing Delta IV launch vehicle—Pulse-settling approach for second-stage hydrogen propellant management. Acta Astronaut. 2007, 61, 416–424. [Google Scholar] [CrossRef]
  17. Sherif, S. Liquid hydrogen: Potential, problems, and a proposed research program. Int. J. Hydrogen Energy 1997, 22, 683–688. [Google Scholar] [CrossRef]
  18. Available online: https://www.etnews.com/20210324000045 (accessed on 20 October 2024).
  19. GB150-2011; National Standard Specification for Pressure Vessels. Standardization Administration of China: Beijing, China, 2011.
  20. Ustolin, F.; Paltrinieri, N.; Berto, F. Loss of integrity of hydrogen technologies: A critical review. Int. J. Hydrogen Energy 2020, 45, 23809–23840. [Google Scholar] [CrossRef]
  21. Park, W.S.; Yoo, S.W.; Kim, M.H.; Lee, J.M. Strain-rate effects on the mechanical behavior of the AISI 300 series of austenitic stainless steel under cryogenic environments. Mater. Des. 2010, 31, 3630–3640. [Google Scholar] [CrossRef]
  22. Krenn, A.G. Diagnosis of a poorly performing liquid hydrogen bulk storage sphere. In Proceedings of the ADVANCES IN CRYOGENIC ENGINEERING: Transactions of the Cryogenic Engineering Conference, Spokane, WA, USA, 13–17 June 2011; Volume 1434, pp. 376–383. [Google Scholar] [CrossRef]
  23. Melnychuk, M.; Poteichuk, M.; Kashytskyi, V.; Sosnowski, M.; Kutsyk, S. Thermo-mechanical properties of perlite composite. In Lecture Notes in Mechanical Engineering; Springer International Publishing: Berlin/Heidelberg, Germany, 2021; pp. 330–338. [Google Scholar] [CrossRef]
  24. ANSYS Inc. Material Properties: Steel (ANSYS Mechanical Version 2022 R1); ANSYS: Canonsburg, PA, USA, 2022; Available online: https://www.ansys.com (accessed on 20 October 2024).
  25. Xu, G.; Song, C.; Zhang, H.; Lu, H.; Wu, D.; Luo, K.; Lu, J. Spatially heterogeneous microstructure in in-situ TiO-reinforced Ti6Al4V/316L functionally graded material fabricated via directed energy deposition. Addit. Manuf. 2022, 59, 103178. [Google Scholar] [CrossRef]
  26. Godec, M.; Zaefferer, S.; Podgornik, B.; Šinko, M.; Tchernychova, E. Quantitative multiscale correlative microstructure analysis of additive manufacturing of stainless steel 316L processed by selective laser melting. Mater. Charact. 2020, 160, 110074. [Google Scholar] [CrossRef]
  27. Composite Material Colue Market Co., Ltd. Material Properties: Steel: Glass Fiber Reinforced Plastic. 2023. Available online: https://www.bilibili.com/opus/849574857947480117 (accessed on 20 October 2024).
  28. San Marchi, C.; Zimmerman, J.A.; Tang, X.; Kernion, S.J.; Thürmer, K.; Nibur, K.A. Fatigue life of austenitic stainless steel in hydrogen environments. In Proceedings of the ASME 2015 Pressure Vessels and Piping Conference, Boston, MA, USA, 19–23 July 2015. [Google Scholar] [CrossRef]
  29. Singh, C.; Lee, T.; Lee, K.H.; Kim, Y.S.; Huang, E.-W.; Jain, J.; Liaw, P.K.; Lee, S.Y. Exceptional fatigue-resistant austenitic stainless steel for cryogenic applications. Appl. Mater. Today 2024, 38, 102195. [Google Scholar] [CrossRef]
  30. Wang, L.; Li, Y.; Li, C.; Zhao, Z. CFD investigation of thermal and pressurization performance in LH2 tank during discharge. Cryogenics 2013, 57, 63–73. [Google Scholar] [CrossRef]
  31. Jeong, S.-J.; Lee, S.-J.; Moon, S.-J. CFD Thermo-hydraulic evaluation of a liquid hydrogen storage tank with different insulation thickness in a small-scale hydrogen liquefier. Fluids 2023, 8, 239. [Google Scholar] [CrossRef]
  32. ISO 13985:2006; Liquid Hydrogen: Land Vehicle Fuel Tanks. International Organization for Standardization: Geneva, Switzerland, 2006.
  33. China Classification Society. Specifications for the use of Natural Gas Fuel in Ships. China Classification Society. 23 March 2024, p. 48. Available online: https://www.ccs.org.cn/ccswz/specialDetail?id=202403260326799291 (accessed on 20 October 2024).
Figure 1. Carbon Dioxide Emissions by Main Vessel Types [1].
Figure 1. Carbon Dioxide Emissions by Main Vessel Types [1].
Symmetry 17 01497 g001
Figure 2. An Explosion at a Hydrogen Refueling Station in Norway in 2019.
Figure 2. An Explosion at a Hydrogen Refueling Station in Norway in 2019.
Symmetry 17 01497 g002
Figure 3. A fire broke out on a tube trailer carrying hydrogen, believed to have been caused by overheating the brake, on the Dangjin and Yeongdeok Expressway in 2021.
Figure 3. A fire broke out on a tube trailer carrying hydrogen, believed to have been caused by overheating the brake, on the Dangjin and Yeongdeok Expressway in 2021.
Symmetry 17 01497 g003
Figure 4. Configure Hydrogen Fuel Cell Ship [18].
Figure 4. Configure Hydrogen Fuel Cell Ship [18].
Symmetry 17 01497 g004
Figure 5. Liquid Hydrogen Storage Tank for Hydrodynamic Container Transport Ships.
Figure 5. Liquid Hydrogen Storage Tank for Hydrodynamic Container Transport Ships.
Symmetry 17 01497 g005
Figure 6. S-N Curve of Steel for Platform.
Figure 6. S-N Curve of Steel for Platform.
Symmetry 17 01497 g006
Figure 7. S-N Curve of 316 L Stainless Steel for Storage Tank.
Figure 7. S-N Curve of 316 L Stainless Steel for Storage Tank.
Symmetry 17 01497 g007
Figure 8. Fatigue Test Results of 316 L Stainless Steel at Room Temperature and 15 K, from the Study by Singh et al. [29].
Figure 8. Fatigue Test Results of 316 L Stainless Steel at Room Temperature and 15 K, from the Study by Singh et al. [29].
Symmetry 17 01497 g008
Figure 9. Fatigue Test Results of 316 L Stainless Steel at Room Temperature and 223 K, from the Study by San et al. [28].
Figure 9. Fatigue Test Results of 316 L Stainless Steel at Room Temperature and 223 K, from the Study by San et al. [28].
Symmetry 17 01497 g009
Figure 10. Center Line and Wall Temperature Profiles at the end of Discharge, from the Study by Wang et al. [30].
Figure 10. Center Line and Wall Temperature Profiles at the end of Discharge, from the Study by Wang et al. [30].
Symmetry 17 01497 g010
Figure 11. Temporal Evolution of Averaged Temperature Profiles of Tank Wall for Three Different Insulation Thickness, from the Study by Jeong et al. [31].
Figure 11. Temporal Evolution of Averaged Temperature Profiles of Tank Wall for Three Different Insulation Thickness, from the Study by Jeong et al. [31].
Symmetry 17 01497 g011
Figure 12. Tank Mesh Model for Fluid Analysis.
Figure 12. Tank Mesh Model for Fluid Analysis.
Symmetry 17 01497 g012
Figure 13. Boundary and Loading Conditions in Fluid Analysis.
Figure 13. Boundary and Loading Conditions in Fluid Analysis.
Symmetry 17 01497 g013
Figure 14. Time-dependent Acceleration used as a Loading Condition.
Figure 14. Time-dependent Acceleration used as a Loading Condition.
Symmetry 17 01497 g014
Figure 15. Distribution of Gas and Liquid in Liquid Hydrogen Tank.
Figure 15. Distribution of Gas and Liquid in Liquid Hydrogen Tank.
Symmetry 17 01497 g015
Figure 16. Pressure Changes caused by Liquid Sloshing.
Figure 16. Pressure Changes caused by Liquid Sloshing.
Symmetry 17 01497 g016
Figure 17. Finite Element Model of Liquid Hydrogen Storage System.
Figure 17. Finite Element Model of Liquid Hydrogen Storage System.
Symmetry 17 01497 g017
Figure 18. Boundary and Loading Conditions in Dynamic Response Analysis.
Figure 18. Boundary and Loading Conditions in Dynamic Response Analysis.
Symmetry 17 01497 g018
Figure 19. Displacement Analysis Results of the Entire Structure.
Figure 19. Displacement Analysis Results of the Entire Structure.
Symmetry 17 01497 g019
Figure 20. Stress Analysis Results of Liquid Hydrogen Storage Tank.
Figure 20. Stress Analysis Results of Liquid Hydrogen Storage Tank.
Symmetry 17 01497 g020
Figure 21. Fatigue Life Analysis Results of Liquid Hydrogen Storage Tank.
Figure 21. Fatigue Life Analysis Results of Liquid Hydrogen Storage Tank.
Symmetry 17 01497 g021
Figure 22. Design Variables for Sensitivity Analysis.
Figure 22. Design Variables for Sensitivity Analysis.
Symmetry 17 01497 g022
Figure 23. Sensitivity Analysis Results; (a) Sensitivity Results of the Circular Support Ring; (b) Sensitivity Results of the Inner Tank.
Figure 23. Sensitivity Analysis Results; (a) Sensitivity Results of the Circular Support Ring; (b) Sensitivity Results of the Inner Tank.
Symmetry 17 01497 g023
Figure 24. Design Variable Values after Design Improvement.
Figure 24. Design Variable Values after Design Improvement.
Symmetry 17 01497 g024
Figure 25. Von Mises Stress Result after Design Improvement.
Figure 25. Von Mises Stress Result after Design Improvement.
Symmetry 17 01497 g025aSymmetry 17 01497 g025b
Figure 26. Fatigue Life Result after Design Improvement.
Figure 26. Fatigue Life Result after Design Improvement.
Symmetry 17 01497 g026aSymmetry 17 01497 g026b
Table 1. Geometric Dimensions of Marine Liquid Hydrogen Storage Tank.
Table 1. Geometric Dimensions of Marine Liquid Hydrogen Storage Tank.
Outer Tank (mm)Inner Tank (mm)
Thickness59.1
Cylinder Length2003.62003.6
Total length2247.22175.4
Inner Diameter886.4800
Table 2. Material Properties of Steel used in Platform [24].
Table 2. Material Properties of Steel used in Platform [24].
Material PropertySteel
Density [kg/m3]7850
Poisson’s Ratio0.30
Young’s Modulus [GPa]200
Ultimate Tensile Strength [MPa]460
Yield Strength [MPa]250
Table 3. Material Properties of 316 L Stainless Steel used in Storage Tank [25,26].
Table 3. Material Properties of 316 L Stainless Steel used in Storage Tank [25,26].
Material Property316 L Stainless Steel
Density [kg/m3]7850
Poisson’s Ratio0.27
Young’s Modulus [GPa]210
Ultimate Tensile Strength [MPa]512
Yield Strength [MPa]350
Table 4. Material Properties of GFRP used in Support [27].
Table 4. Material Properties of GFRP used in Support [27].
Material PropertyGFRP
(Glass Fiber Reinforced Plastic)
Density [kg/m3]2500
Poisson’s Ratio0.22
Young’s Modulus [GPa]15.3
Ultimate Tensile Strength [MPa]700
Yield Strength [MPa]200
Table 5. Fatigue Life Analysis Results of Initial Design.
Table 5. Fatigue Life Analysis Results of Initial Design.
ClassificationTarget Fatigue LifeFatigue Life Result
(a) Circular Support Ring106 Cycles129,670 Cycles
(b) Inner Tank92,757 Cycles
Table 6. Detailed Sensitivity Results using the Finite Difference Method.
Table 6. Detailed Sensitivity Results using the Finite Difference Method.
Circular Support Ring
Design VariablesInitial Stress [MPa]Sensitivity Stress [MPa]Sensitivity
T1253.03252.98−50
T2253.016−14
Inner Tank
Design VariablesInitial Stress [MPa]Sensitivity Stress [MPa]Sensitivity
T3262.58262.55−30
D1262.59414
Table 7. Comparison of Results between the Initial and Design Improvement Model.
Table 7. Comparison of Results between the Initial and Design Improvement Model.
ClassificationMass [kg]Inner TankCircular Support Ring
Stress [MPa]Fatigue Life [Cycles]Stress [MPa]Fatigue Life [Cycles]
Initial Design922.23262.5892,757253.031.297 × 105
Improved Design1060.9191.121.313 × 106186.831.60 × 106
Growth Rate15%−27.2%1315.5%−26.2%1133.6%
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Xu, H.; Kwon, S.; Go, M.; Li, J.-Q. Symmetry-Oriented Design Optimization for Enhancing Fatigue Life of Marine Liquid Hydrogen Storage Tanks Under Asymmetric Sloshing Loads. Symmetry 2025, 17, 1497. https://doi.org/10.3390/sym17091497

AMA Style

Xu H, Kwon S, Go M, Li J-Q. Symmetry-Oriented Design Optimization for Enhancing Fatigue Life of Marine Liquid Hydrogen Storage Tanks Under Asymmetric Sloshing Loads. Symmetry. 2025; 17(9):1497. https://doi.org/10.3390/sym17091497

Chicago/Turabian Style

Xu, Heng, SoonKi Kwon, ManSoo Go, and Ji-Qiang Li. 2025. "Symmetry-Oriented Design Optimization for Enhancing Fatigue Life of Marine Liquid Hydrogen Storage Tanks Under Asymmetric Sloshing Loads" Symmetry 17, no. 9: 1497. https://doi.org/10.3390/sym17091497

APA Style

Xu, H., Kwon, S., Go, M., & Li, J.-Q. (2025). Symmetry-Oriented Design Optimization for Enhancing Fatigue Life of Marine Liquid Hydrogen Storage Tanks Under Asymmetric Sloshing Loads. Symmetry, 17(9), 1497. https://doi.org/10.3390/sym17091497

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop