1. Introduction
Air quality in Poland is one of the most important research topics concerning atmospheric aerosol pollution [
1,
2,
3]. Special attention is given to air pollution by heavy metals and particulate matter (PM) in areas of high exposure and smog [
4,
5,
6,
7,
8]. The main causes of poor air quality in Poland include: quality of heating systems used in households [
8,
9,
10,
11] and emissions generated by vehicular traffic [
8,
10,
11].
Among the different types of pollutants involved in the overall atmospheric aerosol contamination, short-lasting but active point sources of pollution should also be considered [
12,
13], which include fireworks shows [
14]. This is one of the most unusual sources of air pollution, which has been investigated quite frequently and on a large scale in the literature [
15,
16,
17] which allows the identification of specific pollutants related only to the burning of fireworks [
18,
19]. Although the show associated with the New Year celebrations only takes place once a year, it has a very significant impact on the air quality. The environmental pollution burden is enormous in terms of sudden increases in pollution by selected heavy metals, PM of various fractions and also negative health effects [
18,
20].
People’s activity related to celebrating the New Year in such a way causes that, along with the increase of social awareness of the bad condition of the environment (including the atmosphere), people ′′run away′′ from polluted places and move, if only for a short time, to places where the air quality is better [
21]. This choice is made possible by increasingly better ways of predicting and forecasting air pollution, based for example on various types of air pollution indices (APIs) [
22]. Such methods are also used in the air pollution mathematical model for comparison with moss biomonitoring results [
23]. This biological method of environmental assessment is becoming increasingly competitive with instrumental methods for measuring environmental pollution [
24], but due to its lack of referenceability in relation to classical measurement methods, it is an object of continuous standardisation and review [
25], which does not prevent it from being included in the national system for assessing environmental quality and monitoring pollution [
26].
For active biomonitoring studies using mosses, however, it is crucial to use a biomonitor whose (research) value matches its definition [
27]. Moss as a biological indicator of air quality is not only a chemical adsorbent [
28], but above all a living organism [
29], so it is important to control and measure vital parameters during the experiment [
30]. Research to date indicates that moss as a biomonitor of air pollution, e.g., heavy metals, is most often used for short exposure periods. Such studies were performed for a minimum of one day [
31], several days [
32,
33] or a week of time [
34]. This is mainly related to the fast feedback time about the air condition at the study site [
25]. So far, only a laboratory experiment was encountered in the literature [
35], in which moss was used as a biomonitor of air quality analytes from fireworks being fired. In the second case, the authors only suspected contamination of the biomonitors due to fireworks being fired [
36]. It was used as a space to use in an environmental the use of a moss bioindicator to assess the concentrations of pollutants emitted by fireworks as they are set off on New Year’s Eve under field conditions.
The aim of this study was to measure the concentrations of heavy metals accumulated by the moss Pleurozium schreberi in a town during the fireworks show on New Year’s Eve at the turn of 2 consecutive years. The moss species Pleurozium schreberi has also been shown to be a sensitive biomonitor of point sources of pollution.
3. Results
Table 3 shows the statistical parameters of heavy metal concentrations in moss samples.
At least up to the upper quartile Ni content in moss samples was lower than the instrumental quantification limit. Similarly, in most of the samples Cd concentration was lower than the IQL.
The presented metal concentrations in mosses are comparable to those obtained in the woods of Turawa commune in opolskie voivodship [
46], although they are low in relation to industrial sites of Upper Silesia [
47].
Figure 2a–d shows a comparison of heavy metal concentrations accumulated by mosses over two exposure periods: mid December 2019/mid January 2020 and mid December 2020/mid January 2021. The mean concentrations of determined heavy metals (mg/kg dm) naturally accumulated in mosses exposed during the first year of the study were for: Ni—<1.25, Cu—5.85, Zn—53.5, Cd—<0.325, Hg—0.038, Pb—7.85. and in mosses exposed in the second year of the study were respectively: Ni—<1.25, Cu—6.42, Zn—42.8, Cd—<0.325, Hg—0.019, Pb—2.12.
In
Figure 2, it can be seen that heavy metal accumulation by mosses was observed during both study periods. Elemental concentrations from 2019/2020 are higher than for the second study period. For copper, zinc, lead and mercury the values for the “NYE” in 2019/2020 period only were 20.9, 90.7, 19.2, 0.04 mg/kg d.m., respectively, though during the same period in 2020/2021 they were half as high. For nickel and cadmium, depending on the survey year and exposure period, the concentration of these metals in some moss samples was below the limit of quantification of the analytical method used. Additionally, the values for Cu, Zn and Pb for 2019/2020 reach their highest values only during the 2-day “NYE” exposure [31 December and 1 January]. In the following year, the concentrations of these elements are more homogeneous across the different periods of moss exposure.
The effect of meteo conditions on heavy metal concentrations in moss samples was also analyzed. The source of data was the Institute of Meteorology and Water Management [
48]. During 1st half of both exposure periods an irregular decrease in mean air temperature
T was observed. Starting from NYE the mean temperatures did not exhibit a clear trend of changes. At NYE 2019/2020 and 2020/2021 the difference in
T was 5.1 °C. It should be noticed that
T at 2019/2020 was positive, and negative at 2020/2021. Time patterns of relative air humidity H
r changes were different during exposure periods. The humidity difference at the first and second NYE was 23.5%. In a period from 30 December to 2 January no precipitation was observed at both NYE. Additionally, a few days before and after this period precipitation was poor. During exposure periods wind speed
v was in the range 1.0–5.8 m/s. At the two NYE the wind speed difference was 2.6 m/s. In
Figure S1 in the supplementary material parameters describing weather conditions during the moss samples exposure are presented. For moss samples duration of deposition was different. To estimate an intensity of the deposition, a ratio
ct of chemical elements’ concentration and the deposition time
t was calculated. In
Figure 3. boxplots of the calculated
ct are presented. For the metals studied, clear differences in deposition intensities are observed.
To test uniformity of central values in the grouped ct the Kruskal-Wallis test was used. In calculations the group data were pooled over years 2019–2020. The p-values calculated were 6.4 × 10−5 (Ni), 4.8 × 10−5 (Cu), 4.9 × 10−6 (Zn), 1.0 × 10−3 (Cd), 1.7 × 10−3 (Pb), and 2.7 × 10−5 (Hg). For comparisons of median ct in pairs of individual periods the pairwise Wilcoxon test was used. For p-values multiple testing Bonferroni correction was applied. A critical p-value = 0.05 was applied in the test result interpretation.
In
Table 4 the
p-values calculated in Wilcoxon test for intensity of Ni deposition during the periods studied are presented. Numerous
IQL results disables comparison of some groups. Pairs of groups which cannot be compared are marked using “x” symbol. For Cu, Zn, Cd, Pd and Hg, results are included in
Tables S1–S5 in the supplementary material).
In all pairs of the periods the null hypothesis cannot be rejected. This conclusion is apparently inconsistent with observation on
Figure 3a where
cl for NYE_Af and y1 clearly dominates all other periods. But in contrast,
ct in NYE_Af and y2 is considerably lower than that during y1, and as a result an effect of NYE_Af become statistically insignificant.
For Cu, Zn, Cd, Pb and Hg deposition intensity in group NYE and deposititions in the remaining groups all p-values were lower than the critical one. This result indicates statistically significant difference between metal deposition intensities during NYE and during the other periods.
In
Figure 3, it can be seen that metal concentrations vary considerably between the study periods when relating them to exposure time (number of days). For Cu, Zn, Hg and Pb, concentrations in 2019/2020 for the NYE period significantly exceed the corresponding period in the following year. In the next step of the analysis of the results, the increments in the concentrations of heavy metals accumulated in the mosses were determined.
Table 5 shows a summary of the
RAF values for both study periods for each element separately.
Due to the fact that in some of the moss samples the concentration of nickel and cadmium was below the limit of quantification of the analytical method used, no RAF increments were noted (n.d.). For the other elements, high RAF values were observed for copper, zinc and lead, especially during the 2019/2020 period. In the ‘NYE’ period itself, RAF values are higher or comparable to other periods where exposure has been longer. The exceptions are cadmium and mercury, where increases are higher after New Year’s Eve and in 2020/2021.
To assess the condition of the mosses during the exposure period, chlorophyll fluorescence was measured (
Table 6).
The chlorophyll fluorescence values varied between the study periods. The lowest value was measured in the period before New Year’s Eve and the highest value was observed during the “B_NYE” exposure. Since this period the Photosynthetic Yield of Photo System (II) has decreased by about 64% to “Af”. The sample exposed for the whole time was not statistically significantly different from the control.
4. Discussion
Concentrations of the heavy metals Ni, Cu, Zn, Cd, Pb and Hg, accumulated by
Pleurozium schreberi mosses samples differ from each other within and between study periods of a given year. The concentration of individual elements is influenced by the moss species used and their accumulation capacity, exposure time and other environmental factors (interactions among elements, temperature, humidity) [
49,
50,
51]. The changes in concentrations between the two study periods are also due to the global lockdown situation caused by the coronavirus pandemic restrictions. In the literature, one can find results indicating that air pollution has decreased significantly in this period in comparison to the values previously reported [
52,
53]. The impact of the pandemic on air pollution in terms of biological monitoring has so far been described by only one known publication, where is indicated that concentrations of selected metals accumulated by the moss
Pleurozium schreberi, as part of passive biomonitoring studies, decreased by lockdown [
54]. Our study confirms the above statements that heavy metal concentrations during the “NYE” period and in 2020/2021 were lower compared to the same period a year earlier (see
Figure 3). This was influenced by national restrictions related to the limited possibility of overcrowding and participation in mass events celebrating the New Year, which had an impact on the reduced emissions from fireworks fired. According to the literature, air concentrations of heavy metals such as Cu, Zn and Pb are related to their emission during the fireworks burning [
17,
18,
20,
55,
56,
57] as was also confirmed by this research. During moss exposure for only 2 days (NYE period) [31 December and 1 January], concentrations of these elements were characterised by values comparable or higher to periods of longer exposure to moss contamination with these analytes (see also
Figure 3). In our opinion, the results presented here represent the first environmental experiment using the moss-bag technique to determine the concentrations of heavy metals accumulated by mosses during New Year’s Eve (due to fireworks burning), together with the impact of the pandemic on air pollution at this time using active moss biomonitoring.
RAF values higher than 1.00 indicate significant elemental enrichment [
58]. Such values were recorded for copper and lead in 2019/2020 and the impact of increases in these elements was related to the fireworks being fired. In contrast, high increments for nickel and mercury may be related to other air pollutants sources such as local, low level emissions [
59].
The actual quantum efficiency of PSII photochemistry in the light measures the fraction of the absorbed light energy that is actually being used to drive photochemistry at PSII [
60]. Its value is influenced by a number of factors, such as a change in metal concentration [
61,
62] and a positive effect on the increase in fluorescence yield over the course of the experiment may have been due to variable hydration [
63]. The dependence of chlorophyll fluorescence yield variability on water content has been reported previously for
Pleurozium moss [
64] and our actual quantum yield values of PSII photochemistry were comparable with the results obtained by other authors for this species [
65,
66]. Due to the association of chlorophyll fluorescence with other vital parameters (chlorophyll content, osmotic indices, antioxidant enzyme activities) [
67], we know that biomonitoring studies have been conducted on a living air quality bioindicator [
68].
5. Conclusions
The results of the biomonitoring study indicate a variable air quality in the town of Prószków during New Year’s Eve on the example of a two-year study. Increased concentrations of copper, zinc and lead only during the 2-day “NYE” exposure confirm the effect of fired fireworks on the accumulation of these elements in the moss Pleurozium schreberi. This demonstrates the good accumulation capacity of this species for use during short periods of exposure to air pollution. Further research should focus on finding the best moss species for the determination of heavy metals in air from fireworks smoke.
Deposition of metals on moss during and after fireworks show could be affected by weather conditions. During the periods studied, the temperature, humidity, and wind speed were similar but not the same. A common feature at both NYE was no precipitation.
Actually the results of our research did not provide feasible information to estimate an influence of weather conditions on metals′ deposition after fireworks show. Valid conclusions could be drawn from repeated observations. This assertion implies continuation of the research with extension to other than NYE celebrations.
In the literature, the use of classical methods for determination of metals concentration in the air during fireworks show has been already described, but our study confirms the possibility of using bioindicators in air quality monitoring as a complementary method. Biomonitoring studies using the moss-bag method for the determination of other pollutants from fireworks shows should be continued.
In addition, the positive impact of the 2020/2021 lockdown on air pollution from emissions of fireworks launched was demonstrated, which was confirmed by determining lower concentrations of selected heavy metals accumulated by mosses. The practice of welcoming the New Year should change the accepted way of celebrating to one that does not cause deterioration of air quality and further pollution emissions.