Next Article in Journal
An Adaptive-Output Operational Amplifier for Electrostatic Closed-Loop MEMS Gyroscope Drive Circuits
Previous Article in Journal
Design and Optimization of High-G Graphene MEMS Acceleration Sensor
Previous Article in Special Issue
Portable and Point-of-Care Testing Approach for Determining Soil Extracellular Enzyme Activities
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection

by
Youssef O. Al-Ghamdi
1,
Amani Chrouda
1,
Nicole Jaffrezic-Renault
2,* and
Hamdi Ben Halima
2,*
1
Department of Chemistry, College of Science Al-Zulfi, Majmaah University, Al-Majmaah 11952, Saudi Arabia
2
CNRS, Institut UTINAM (UMR 6213), Université Marie et Louis Pasteur, F-25000 Besançon, France
*
Authors to whom correspondence should be addressed.
Micromachines 2026, 17(8), 901; https://doi.org/10.3390/mi17080901
Submission received: 30 June 2026 / Revised: 22 July 2026 / Accepted: 24 July 2026 / Published: 27 July 2026

Abstract

Glyphosate is among the most widely used herbicides worldwide, and its extensive application has led to increasing concerns regarding environmental contamination and potential risks to human health. The persistence of this compound in soil and aquatic environments has created an urgent demand for analytical methods that are rapid, reliable, and economically feasible. In the present study, a microconductometric sensing platform was developed for glyphosate determination using a PVC liquid membrane incorporating an [o-COSAN]⁻/glyphosate ion-pair complex deposited onto interdigitated electrodes. The proposed sensor provided a linear analytical response over the concentration range of 1.0 × 10⁻5 to 2.5 × 10⁻3 M, with a detection limit of 4 μM. The device also exhibited excellent analytical performance, with reproducibility and repeatability values of 3% and 8% (RSD), respectively. Furthermore, the sensor maintained stable performance for more than three months and showed a high degree of selectivity toward glyphosate when evaluated against potential interfering compounds, including AMPA and carbofuran. These results demonstrate the potential of the proposed sensing platform as a simple, sensitive, and cost-effective tool for glyphosate monitoring in environmental samples.
Keywords: glyphosate; conductimetric sensor; ion-pair complex; environmental monitoring glyphosate; conductimetric sensor; ion-pair complex; environmental monitoring

Share and Cite

MDPI and ACS Style

Al-Ghamdi, Y.O.; Chrouda, A.; Jaffrezic-Renault, N.; Ben Halima, H. Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection. Micromachines 2026, 17, 901. https://doi.org/10.3390/mi17080901

AMA Style

Al-Ghamdi YO, Chrouda A, Jaffrezic-Renault N, Ben Halima H. Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection. Micromachines. 2026; 17(8):901. https://doi.org/10.3390/mi17080901

Chicago/Turabian Style

Al-Ghamdi, Youssef O., Amani Chrouda, Nicole Jaffrezic-Renault, and Hamdi Ben Halima. 2026. "Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection" Micromachines 17, no. 8: 901. https://doi.org/10.3390/mi17080901

APA Style

Al-Ghamdi, Y. O., Chrouda, A., Jaffrezic-Renault, N., & Ben Halima, H. (2026). Development of an o-COSAN Ion-Pair Complex-Modified PVC Membrane for Microconductometric Glyphosate Detection. Micromachines, 17(8), 901. https://doi.org/10.3390/mi17080901

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop