Next Article in Journal
Corner Simulation of CMOS Analog Integrated Circuit Taking into Account Radiation Influence
Next Article in Special Issue
Deep Learning-Based Prediction and Compensation of Performance Degradation in Flexible Sensors
Previous Article in Journal
High-Efficiency and Low-Defect Removal Mechanism of Silicon Carbide Using Center-Inlet Computer-Controlled Polishing
Previous Article in Special Issue
Denoising Method for NV-Center Fluorescence Signals Based on MPA-VMD Combined with Wavelet Thresholding
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Electrochemical Characterization and Sensitive Voltammetric Determination of Etamsylate at a Boron-Doped Diamond Electrode

Department of Analytical Chemistry and Biochemistry, Faculty of Materials Science and Ceramics, AGH University of Krakow, 30-059 Krakow, Poland
*
Author to whom correspondence should be addressed.
Micromachines 2026, 17(3), 299; https://doi.org/10.3390/mi17030299
Submission received: 29 January 2026 / Revised: 25 February 2026 / Accepted: 25 February 2026 / Published: 27 February 2026

Abstract

This study presents the development of a highly sensitive and selective electrochemical method for the determination of etamsylate (ETM) using a Boron-Doped Diamond (BDD) electrode. Analytical conditions were optimized using Square Wave Voltammetry (SWV), establishing an orthophosphoric acid (V) solution as the ideal supporting electrolyte. Under optimized instrumental parameters, the sensor demonstrated a superior linear response with a correlation coefficient of 0.999. The calculated limit of detection (LOD) was 0.10 µmol L−1 (0.026 mg L−1), with very good repeatability, indicated by an RSD of 3.17%. The practical utility of the BDD electrode was confirmed through the analysis of pharmaceutical and spiked biological samples, yielding recovery values between 95% and 102%. The results indicate that this method serves as a robust, cost-effective, and efficient alternative for routine quality control, clinical diagnostics, and environmental monitoring of etamsylate.
Keywords: etamsylate; Boron-Doped Diamond electrode; Square Wave Voltammetry etamsylate; Boron-Doped Diamond electrode; Square Wave Voltammetry

Share and Cite

MDPI and ACS Style

Smajdor-Baran, J.; Fendrych, K.; Baś, B.; Piech, R. Electrochemical Characterization and Sensitive Voltammetric Determination of Etamsylate at a Boron-Doped Diamond Electrode. Micromachines 2026, 17, 299. https://doi.org/10.3390/mi17030299

AMA Style

Smajdor-Baran J, Fendrych K, Baś B, Piech R. Electrochemical Characterization and Sensitive Voltammetric Determination of Etamsylate at a Boron-Doped Diamond Electrode. Micromachines. 2026; 17(3):299. https://doi.org/10.3390/mi17030299

Chicago/Turabian Style

Smajdor-Baran, Joanna, Katarzyna Fendrych, Bogusław Baś, and Robert Piech. 2026. "Electrochemical Characterization and Sensitive Voltammetric Determination of Etamsylate at a Boron-Doped Diamond Electrode" Micromachines 17, no. 3: 299. https://doi.org/10.3390/mi17030299

APA Style

Smajdor-Baran, J., Fendrych, K., Baś, B., & Piech, R. (2026). Electrochemical Characterization and Sensitive Voltammetric Determination of Etamsylate at a Boron-Doped Diamond Electrode. Micromachines, 17(3), 299. https://doi.org/10.3390/mi17030299

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop