Next Article in Journal
Charge Injection and Dielectric Characteristics of Polyethylene Terephthalate Based on Semiconductor Electrodes
Next Article in Special Issue
Quantifying the Comprehensive Characteristics of Inclusion-Induced Defects Using an Integrated Destructive and Non-Destructive Method
Previous Article in Journal
Abrasive Sensitivity of Martensitic and a Multi-Phase Steels under Different Abrasive Conditions
Previous Article in Special Issue
Effect of Moisture Distribution on Velocity and Waveform of Ultrasonic-Wave Propagation in Mortar
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Indirect Determination of Residual Prestressing Force in Post-Tensioned Concrete Beam

1
Department of Structures and Bridges, Faculty of Civil Engineering, University of Žilina, Univerzitná 8215/1, 01026 Žilina, Slovakia
2
Laboratory of Civil Engineering, University of Žilina, Univerzitná 8215/1, 01026 Žilina, Slovakia
*
Author to whom correspondence should be addressed.
Materials 2021, 14(6), 1338; https://doi.org/10.3390/ma14061338
Submission received: 25 February 2021 / Revised: 3 March 2021 / Accepted: 7 March 2021 / Published: 10 March 2021
(This article belongs to the Special Issue Research on Non-destructive Testing in Civil Engineering Materials)

Abstract

A diagnostic survey on the precast prestressed bridge Nižná confirmed significant deterioration due to environmental distress. Evidently, decisive failures of the structure have a similar character as in the previous precast prestressed bridge in Podbiel in the northern part of Slovakia. These failures result from the unsuitable concept of the first generation of precast prestressed concrete beams, which was used in the former Czechoslovakia in the second half of the 20th century. Subsequently, experimental verification using the proof-load test was also executed. This bridge was built in 1956, so at the time of testing, it was 60 years old. The paper presents the indirect determination of prestressing level in one precast post-tensioned concrete beam using the saw-cut method. Experimental measurement was executed during the bridge demolition. Subsequently, a 2D numerical model in ATENA 2D Software, with the assumption of nonlinear material behavior for verification of experimental results, was performed. Finally, the residual prestressing force was evaluated and compared with the expected state of prestressing according to Eurocodes after 60 years of service.
Keywords: prestressing force; saw-cut testing; assessment; in situ test prestressing force; saw-cut testing; assessment; in situ test

Share and Cite

MDPI and ACS Style

Kraľovanec, J.; Moravčík, M.; Bujňáková, P.; Jošt, J. Indirect Determination of Residual Prestressing Force in Post-Tensioned Concrete Beam. Materials 2021, 14, 1338. https://doi.org/10.3390/ma14061338

AMA Style

Kraľovanec J, Moravčík M, Bujňáková P, Jošt J. Indirect Determination of Residual Prestressing Force in Post-Tensioned Concrete Beam. Materials. 2021; 14(6):1338. https://doi.org/10.3390/ma14061338

Chicago/Turabian Style

Kraľovanec, Jakub, Martin Moravčík, Petra Bujňáková, and Jozef Jošt. 2021. "Indirect Determination of Residual Prestressing Force in Post-Tensioned Concrete Beam" Materials 14, no. 6: 1338. https://doi.org/10.3390/ma14061338

APA Style

Kraľovanec, J., Moravčík, M., Bujňáková, P., & Jošt, J. (2021). Indirect Determination of Residual Prestressing Force in Post-Tensioned Concrete Beam. Materials, 14(6), 1338. https://doi.org/10.3390/ma14061338

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop