Next Article in Journal
Pore-Scale Numerical Simulation of CO2–Oil Two-Phase Flow: A Multiple-Parameter Analysis Based on Phase-Field Method
Previous Article in Journal
Large Scale Microalgae Biofuel Technology—Development Perspectives in Light of the Barriers and Limitations
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Economic Assessment of Operation Strategies on Park-Level Integrated Energy System Coupled with Biogas: A Case Study in a Sewage Treatment Plant

Beijing Key Laboratory of Emission Surveillance and Control for Thermal Power Generation, North China Electric Power University, Beijing 102206, China
*
Author to whom correspondence should be addressed.
Energies 2023, 16(1), 80; https://doi.org/10.3390/en16010080
Submission received: 6 December 2022 / Revised: 17 December 2022 / Accepted: 18 December 2022 / Published: 21 December 2022

Abstract

Operation strategies for a park-level integrated energy system (PIES) in terms of carbon prices and feed-in tariffs, have not been adequately studied. This paper addresses this knowledge gap by proposing operation strategies based on the PIES driven by biogas, solar energy, natural gas, and the power grid. Meanwhile, the electricity-driven dispatching strategy (EDS), thermal-driven dispatching strategy (TDS), cost-driven dispatching strategy (CDS) are compared to assess their impacts on operation cost, carbon dioxide emissions, etc. The flexibility and complementarity of the three operation strategies in energy supply are analyzed in detail. The results indicated that biogas was the main energy supply fuel, accounting for 46% to 72% of the total energy supply. About 33% to 54% of electricity was transmitted to the grid each month using the TDS. The annual initial capital cost of the CDS was only 1.39% higher than that of the EDS. However, the annual operation cost of the EDS was 16.86% higher than that of the CDS. The emissions of the EDS were the lowest, and the CDS had 38.51% higher emissions than the EDS. In the CDS, the ratio of carbon emission costs to operation costs was as high as 0.80 when the carbon tax reached USD 100/ton. The carbon tax had a greater impact on the CDS than the other strategies. Feed-in tariffs had a greater impact than the carbon tax on the TDS. This study provides an effective method for the selection of optimal operation strategies in regards to carbon prices and feed-in tariffs.
Keywords: energy system; biogas; carbon; strategy; optimization energy system; biogas; carbon; strategy; optimization

Share and Cite

MDPI and ACS Style

Zhao, X.; Chen, Y.; Xu, G.; Chen, H. Economic Assessment of Operation Strategies on Park-Level Integrated Energy System Coupled with Biogas: A Case Study in a Sewage Treatment Plant. Energies 2023, 16, 80. https://doi.org/10.3390/en16010080

AMA Style

Zhao X, Chen Y, Xu G, Chen H. Economic Assessment of Operation Strategies on Park-Level Integrated Energy System Coupled with Biogas: A Case Study in a Sewage Treatment Plant. Energies. 2023; 16(1):80. https://doi.org/10.3390/en16010080

Chicago/Turabian Style

Zhao, Xin, Yanqi Chen, Gang Xu, and Heng Chen. 2023. "Economic Assessment of Operation Strategies on Park-Level Integrated Energy System Coupled with Biogas: A Case Study in a Sewage Treatment Plant" Energies 16, no. 1: 80. https://doi.org/10.3390/en16010080

APA Style

Zhao, X., Chen, Y., Xu, G., & Chen, H. (2023). Economic Assessment of Operation Strategies on Park-Level Integrated Energy System Coupled with Biogas: A Case Study in a Sewage Treatment Plant. Energies, 16(1), 80. https://doi.org/10.3390/en16010080

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop