Next Article in Journal
Optimal Integration of Renewable Sources and Latent Heat Storages for Residential Application
Next Article in Special Issue
Magnetic FEA Direct Optimization of High-Power Density, Halbach Array Permanent Magnet Electric Motors
Previous Article in Journal
Analysis and Forecasting of PM2.5, PM4, and PM10 Dust Concentrations, Based on In Situ Tests in Hard Coal Mines
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Compensation of Interpolation Error for Look-Up Table-Based PMSM Control Method in Maximum Power Control

1
Inverter Department, LG Magna e-Powertrain, 322, Gyeongmyeong-daero, Seo-gu, Incheon 22744, Korea
2
Department of Electrical Engineering, College of Engineering, Kunsan National University, Gunsan 54150, Korea
*
Author to whom correspondence should be addressed.
These authors contributed equally to this work.
Energies 2021, 14(17), 5526; https://doi.org/10.3390/en14175526
Submission received: 28 July 2021 / Revised: 24 August 2021 / Accepted: 1 September 2021 / Published: 4 September 2021
(This article belongs to the Special Issue All-Electric Propulsion Technology for Electrified Aviation)

Abstract

This paper proposes a compensation method for interpolation error of the maximum power control of a PMSM control system that generates current commands through a look-up table. A torque control system using a look-up table created through experiments has superior characteristics, such as control stability and torque accuracy, compared to a system that executes torque control via a linear controller based on modeling. However, it is impossible to generate information on all the currents for the output torque in the table. Therefore, because the data stored in the look-up table have a discrete characteristic, they are linearly interpolated to generate a current command for the torque command. However, the PMSM current trajectory is generally elliptical, which causes an error owing to linear interpolation, reducing the maximum output power. In particular, when the table data are insufficient, such as in the high-speed operation range, the reduced maximum output cannot be ignored. This paper proposes a compensation method for the interpolation error using two feedforward compensators and a PI controller, which was verified through experiments.
Keywords: 2D-Interpolation; look-up table PMSM drive; interpolation error compensation; feedforward control 2D-Interpolation; look-up table PMSM drive; interpolation error compensation; feedforward control

Share and Cite

MDPI and ACS Style

Kim, D.-Y.; Lee, J.-H. Compensation of Interpolation Error for Look-Up Table-Based PMSM Control Method in Maximum Power Control. Energies 2021, 14, 5526. https://doi.org/10.3390/en14175526

AMA Style

Kim D-Y, Lee J-H. Compensation of Interpolation Error for Look-Up Table-Based PMSM Control Method in Maximum Power Control. Energies. 2021; 14(17):5526. https://doi.org/10.3390/en14175526

Chicago/Turabian Style

Kim, Do-Yun, and Jung-Hyo Lee. 2021. "Compensation of Interpolation Error for Look-Up Table-Based PMSM Control Method in Maximum Power Control" Energies 14, no. 17: 5526. https://doi.org/10.3390/en14175526

APA Style

Kim, D.-Y., & Lee, J.-H. (2021). Compensation of Interpolation Error for Look-Up Table-Based PMSM Control Method in Maximum Power Control. Energies, 14(17), 5526. https://doi.org/10.3390/en14175526

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop