Next Article in Journal
A European Database of Building Energy Profiles to Support the Design of Ground Source Heat Pumps
Previous Article in Journal
Generation Expansion Planning Based on Dynamic Bayesian Network Considering the Uncertainty of Renewable Energy Resources
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Open-Switch Fault Diagnosis Algorithm and Tolerant Control Method of the Three-Phase Three-Level NPC Active Rectifier

1
Department of Electrical and Computer Engineering, Pusan National University, Busan 46241, Korea
2
Converter Station Construction Team, Korea Electric Power Corporation, Naju, Jeollanam-do 58322, Korea
3
Department of Mechanical Facility Control Engineering, Korea University of Technology and Education, Cheonan, Chungnam 31253, Korea
*
Author to whom correspondence should be addressed.
Energies 2019, 12(13), 2495; https://doi.org/10.3390/en12132495
Submission received: 2 June 2019 / Revised: 24 June 2019 / Accepted: 26 June 2019 / Published: 28 June 2019
(This article belongs to the Section F: Electrical Engineering)

Abstract

This paper proposes a fault diagnosis and tolerant control methods for an open-switch fault caused in a three-phase three-level neutral-point-clamped (NPC) pulse-width modulation (PWM) active rectifier. The open-switch fault in the three-level NPC active rectifier causes a distortion in the input phase current and a ripple in the DC-link capacitor voltage. Therefore, proper fault diagnosis and tolerant control methods are required to prevent additional failures and performance degradation in the rectifier system. This paper conducted a detailed analysis of the effect of the single open-switch fault on the NPC PWM active rectifier and proposed a fault diagnosis method utilizing the DC link voltage and the phase angle of the input grid voltage. Furthermore, this paper proposes a fault-tolerant control method to reduce the effect of the open-switch fault by compensating a distorted reference voltage. The effectiveness of the proposed fault diagnosis and tolerant control methods are verified through experimental results.
Keywords: three-level neutral-point clamped (NPC) active rectifier; open-switch fault; fault diagnosis and tolerant control method; space vector modulation (SVM) three-level neutral-point clamped (NPC) active rectifier; open-switch fault; fault diagnosis and tolerant control method; space vector modulation (SVM)

Share and Cite

MDPI and ACS Style

Jung, J.-H.; Ku, H.-K.; Son, Y.-D.; Kim, J.-M. Open-Switch Fault Diagnosis Algorithm and Tolerant Control Method of the Three-Phase Three-Level NPC Active Rectifier. Energies 2019, 12, 2495. https://doi.org/10.3390/en12132495

AMA Style

Jung J-H, Ku H-K, Son Y-D, Kim J-M. Open-Switch Fault Diagnosis Algorithm and Tolerant Control Method of the Three-Phase Three-Level NPC Active Rectifier. Energies. 2019; 12(13):2495. https://doi.org/10.3390/en12132495

Chicago/Turabian Style

Jung, Jun-Hyung, Hyun-Keun Ku, Yung-Deug Son, and Jang-Mok Kim. 2019. "Open-Switch Fault Diagnosis Algorithm and Tolerant Control Method of the Three-Phase Three-Level NPC Active Rectifier" Energies 12, no. 13: 2495. https://doi.org/10.3390/en12132495

APA Style

Jung, J.-H., Ku, H.-K., Son, Y.-D., & Kim, J.-M. (2019). Open-Switch Fault Diagnosis Algorithm and Tolerant Control Method of the Three-Phase Three-Level NPC Active Rectifier. Energies, 12(13), 2495. https://doi.org/10.3390/en12132495

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop