Effectiveness of SARS-CoV-2 Decontamination and Containment in a COVID-19 ICU

1
Donald and Barbara Zucker School of Medicine at Hofstra/Northwell, Northwell Health, Hempstead, NY 11549, USA
2
North Shore University Hospital/Long Island Jewish Emergency Medical Department, Northwell Health, Manhasset, NY 11030, USA
3
Institute of Health Innovations and Outcomes Research, Feinstein Institutes for Medical Research, Northwell Health, Manhasset, NY 11030, USA
4
Department of Physiology and Biophysics, Weill Cornell Medicine, New York, NY 10065, USA
5
The HRH Prince Alwaleed Bin Talal Bin Abdulaziz Alsaud Institute for Computational Biomedicine, Weill Cornell Medicine, New York, NY 10021, USA
*
Authors to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2021, 18(5), 2479; https://doi.org/10.3390/ijerph18052479
Submission received: 3 February 2021 / Revised: 24 February 2021 / Accepted: 1 March 2021 / Published: 3 March 2021

Abstract

Background: Health care systems in the United States are continuously expanding and contracting spaces to treat patients with coronavirus disease 2019 (COVID-19) in intensive care units (ICUs). As a result, hospitals must effectively decontaminate and contain severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in constructed and deconstructed ICUs that care for patients with COVID-19. We assessed decontamination of a COVID-19 ICU and examined the containment efficacy of combined contact and droplet precautions in creating and maintaining a SARS-CoV-2–negative ICU “antechamber”. Methods: To examine the efficacy of chemical decontamination, we used high-density, semi-quantitative environmental sampling to detect SARS-CoV-2 on surfaces in a COVID-19 ICU and COVID-19 ICU antechamber. Quantitative real-time polymerase chain reaction was used to measure viral RNA on surfaces. Viral location mapping revealed the distribution of viral RNA in the COVID-19 ICU and COVID-19 ICU antechamber. Results were further assessed using loop-mediated isothermal amplification. Results: We collected 224 surface samples pre-decontamination and 193 samples post-decontamination from a COVID-19 ICU and adjoining COVID-19 ICU antechamber. We found that 46% of antechamber objects were positive for SARS-CoV-2 pre-decontamination despite the construction of a swinging door barrier system, implementation of contact precautions, and installation of high-efficiency particulate air filters. The object positivity rate reduced to 32.1% and viral particle rate reduced by 95.4% following decontamination. Matched items had an average of 432.2 ± 2729 viral copies/cm2 pre-decontamination and 19.2 ± 118 viral copies/cm2 post-decontamination, demonstrating significantly reduced viral surface distribution (p < 0.0001). Conclusions: Environmental sampling is an effective method for evaluating decontamination protocols and validating measures used to contain SARS-CoV-2 viral particles. While chemical decontamination effectively removes detectable viral RNA from surfaces, our approach to droplet/contact containment with an antechamber was not highly effective. These data suggest that hospitals should plan for the potential of aerosolized virions when creating strategies to contain SARS-CoV-2.
Keywords: environmental sampling; SARS-CoV-2; COVID-19; decontamination; qPCR environmental sampling; SARS-CoV-2; COVID-19; decontamination; qPCR

Share and Cite

MDPI and ACS Style

Brune, Z.; Kuschner, C.E.; Mootz, J.; Davidson, K.W.; Pena, R.C.F.; Ghanem, M.H.; Fischer, A.; Gitman, M.; Teperman, L.; Mason, C.; et al. Effectiveness of SARS-CoV-2 Decontamination and Containment in a COVID-19 ICU. Int. J. Environ. Res. Public Health 2021, 18, 2479. https://doi.org/10.3390/ijerph18052479

AMA Style

Brune Z, Kuschner CE, Mootz J, Davidson KW, Pena RCF, Ghanem MH, Fischer A, Gitman M, Teperman L, Mason C, et al. Effectiveness of SARS-CoV-2 Decontamination and Containment in a COVID-19 ICU. International Journal of Environmental Research and Public Health. 2021; 18(5):2479. https://doi.org/10.3390/ijerph18052479

Chicago/Turabian Style

Brune, Zarina, Cyrus E. Kuschner, Joseph Mootz, Karina W. Davidson, Robert C. F. Pena, Mustafa H. Ghanem, Austin Fischer, Michael Gitman, Lewis Teperman, Christopher Mason, and et al. 2021. "Effectiveness of SARS-CoV-2 Decontamination and Containment in a COVID-19 ICU" International Journal of Environmental Research and Public Health 18, no. 5: 2479. https://doi.org/10.3390/ijerph18052479

APA Style

Brune, Z., Kuschner, C. E., Mootz, J., Davidson, K. W., Pena, R. C. F., Ghanem, M. H., Fischer, A., Gitman, M., Teperman, L., Mason, C., & Becker, L. B. (2021). Effectiveness of SARS-CoV-2 Decontamination and Containment in a COVID-19 ICU. International Journal of Environmental Research and Public Health, 18(5), 2479. https://doi.org/10.3390/ijerph18052479