You are currently viewing a new version of our website. To view the old version click .
by
  • Elliott J. Nunn1,*,
  • Louise S. Natrajan1 and
  • Mark K. Quinn2

Reviewer 1: Anonymous Reviewer 2: Anonymous

Round 1

Reviewer 1 Report

Comments and Suggestions for Authors

The comments to the authors are shown in the attached file.

Comments for author File: Comments.pdf

Author Response

Please see the reply to reviewer 1's comments in the attached document

Author Response File: Author Response.pdf

Reviewer 2 Report

Comments and Suggestions for Authors

In this work, the authors explore the effect of changing the loading quantity of a NIR-emitting para-CF3 Pt(II) benzoporphyrin luminophore on the performance of PSP formulations. This work is very interesting and should be accepted. I only have two questions to communicate with the authors.

  1. When conducting a wind tunnel laboratory, not only will pressure be generated, but also shear force will be generated, which is not mentioned in the article.
  2. What is the typical temperature range when conducting a wind tunnel laboratory? In addition, the phosphorescence lifetime of this near-infrared dye is shorter. Do phosphorescent materials with longer lifetimes have better performance?

Author Response

Please see reply to reviewer 2 in the attached document

Author Response File: Author Response.pdf

Round 2

Reviewer 1 Report

Comments and Suggestions for Authors

The comments for the Authors are shown in the attached file.

Comments for author File: Comments.pdf

Author Response

Please find our response to the reviewer comments in the attached document.

Author Response File: Author Response.pdf