Next Article in Journal
Wideband RCS Reduction Based on Hybrid Checkerboard Metasurface
Next Article in Special Issue
A Portable Three-Layer Compton Camera for Wide-Energy-Range Gamma-ray Imaging: Design, Simulation and Preliminary Testing
Previous Article in Journal
Effects of Law Enforcement Load Carriage Systems on Muscle Activity and Coordination during Walking: An Exploratory Study
Previous Article in Special Issue
Emergency Management in the Event of Radiological Dispersion in an Urban Environment
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection

1
Engineering Department, Lancaster University, Lancaster LA1 4YW, UK
2
Central Laboratory, National Nuclear Laboratory Ltd., Warrington WA3 6AE, UK
*
Author to whom correspondence should be addressed.
Sensors 2023, 23(8), 4053; https://doi.org/10.3390/s23084053
Submission received: 2 March 2023 / Revised: 8 April 2023 / Accepted: 11 April 2023 / Published: 17 April 2023

Abstract

A compact back-end interface for silicon photomultipliers (SiPMs) implementing Zener diode-based temperature compensation has been developed for the remote detection of beta and gamma radiation. Remote detection is facilitated by the development of an efficient data management system utilising MySQL database storage for recording periodic spectra data for wireless access over a private Wi-Fi network. A trapezoidal peak shaping algorithm has been implemented on an FPGA for the continuous conversation of pulses from the SiPM, signifying the detection of a radiological particle, into spectra. This system has been designed to fit within a 46 mm cylindrical diameter for in situ characterization, and can be attached to one or more SiPMs used in conjunction with a range of scintillators. LED blink tests have been used to optimise the trapezoidal shaper coefficients to maximise the resolution of the recorded spectra. Experiments with an array of SiPMs integrated with a NaI(Tl) scintillator exposed to sealed sources of Co-60, Cs-137, Na-22 and Am-241 have shown that the detector achieves a peak efficiency of 27.09 ± 0.13% for a gamma peak at 59.54 keV produced by Am-241, and a minimum energy resolution (Delta E/E) of 4.27 ± 1.16% for the 1332.5 keV gamma peak from Co-60.
Keywords: silicon photomultiplier; gamma detectors; temperature compensation; wireless data acquisition systems silicon photomultiplier; gamma detectors; temperature compensation; wireless data acquisition systems

Share and Cite

MDPI and ACS Style

Dixon, N.E.J.; Monk, S.D.; Graham, J.; Cheneler, D. Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection. Sensors 2023, 23, 4053. https://doi.org/10.3390/s23084053

AMA Style

Dixon NEJ, Monk SD, Graham J, Cheneler D. Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection. Sensors. 2023; 23(8):4053. https://doi.org/10.3390/s23084053

Chicago/Turabian Style

Dixon, Nile E. J., Stephen D. Monk, James Graham, and David Cheneler. 2023. "Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection" Sensors 23, no. 8: 4053. https://doi.org/10.3390/s23084053

APA Style

Dixon, N. E. J., Monk, S. D., Graham, J., & Cheneler, D. (2023). Compact Back-End Electronics with Temperature Compensation and Efficient Data Management for In Situ SiPM-Based Radiation Detection. Sensors, 23(8), 4053. https://doi.org/10.3390/s23084053

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop