Article
Peer-Review Record

Graphene-Based Flexible Strain Sensor Based on PDMS for Strain Detection of Steel Wire Core Conveyor Belt Joints

Sensors 2023, 23(17), 7473; https://doi.org/10.3390/s23177473
by Pengfei Li, Zhijie Li *, Hongyue Chen, Yunji Zhu, Dada Yang and Yang Hou
Reviewer 1:
Reviewer 2:
Sensors 2023, 23(17), 7473; https://doi.org/10.3390/s23177473
Submission received: 28 July 2023 / Revised: 23 August 2023 / Accepted: 23 August 2023 / Published: 28 August 2023
(This article belongs to the Section Physical Sensors)

Round 1

Reviewer 1 Report

1. In abstract (In this study, we used polydimethylsiloxane (PDMS), a common flexible substrate material, to create graphene-based flexible strain sensor films that can be used at the joints of steel wire rope core conveyor belts using a simple drop coating method. ) is not clear. Is need to rewrite as proposed method. Then explain the martial and testing system.

2. In introduction needs to add more details of reference [15-18].

3. In introduction few sentences (By embedding Ag nanoparticles in stretchable fibers, Lee et al. [24] created a highly stretchable large-strain flexible sensor for use in flexible sensor applications. ), (And the steel cord rubber conveyor belt is his main component; the conveyor belt consists of internal steel cord and rubber. ), (The method of detection has a larger detection range and higher accuracy. ) and (And the steel cord rubber conveyor belt is his main component; the conveyor belt consists of internal steel cord and rubber. )

4. Figure 2c and d is not clear , is better to find another way to show the sample size.

5. In section 2.1. Preparation process of graphene need to support your work with references and show why to select this parameters such as ( heated at 75°C for 2 h, dropping graphene dispersion with a concentration of 0.5 mg/m, three sets of flexible strain sensors with graphene component contents of 0.5 mg/mL, 1.0 mg/mL, and 1.5 mg/mL, )

Extensive editing of English language required

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

In this work, authors have reported “Graphene flexible strain sensor based on PDMS for steel wire core conveyor belt connector strain detection”, where they proposed a strain sensor and its practical applications. The manuscript seems well described and presented but needs to address some comments before accepting for publication. The following comments attached below should be addressed carefully.

Comments for author File: Comments.pdf

The manuscript displays poor English presentations in multiple places.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Round 2

Reviewer 2 Report

Presently, the manuscript seems well-written with the proper explanations. However, in the reply to question 2, the authors claimed that the two tests are different and hence the time scale is different. Please write down the time scale for the two measurements.

 

Author Response

Please see the attachment.

Author Response File: Author Response.pdf