Article

DDS and OPC UA Protocol Coexistence Solution in Real-Time and Industry 4.0 Context Using Non-Ideal Infrastructure

Department of Automation and Applied Informatics, Faculty of Automation and Computers, University Politehnica Timișoara, 300223 Timișoara, Romania
*
Author to whom correspondence should be addressed.
Sensors 2021, 21(22), 7760; https://doi.org/10.3390/s21227760
Submission received: 22 October 2021 / Revised: 17 November 2021 / Accepted: 18 November 2021 / Published: 22 November 2021
(This article belongs to the Section Internet of Things)

Abstract

Continuing the evolution towards Industry 4.0, the industrial communication protocols represent a significant topic of interest, as real-time data exchange between multiple devices constitute the pillar of Industrial Internet of Things (IIoT) scenarios. Although the legacy protocols are still persistent in the industry, the transition was initiated by the key Industry 4.0 facilitating protocol, the Open Platform Communication Unified Architecture (OPC UA). OPC UA has to reach the envisioned applicability, and it therefore has to consider coexistence with other emerging real-time oriented protocols in the production lines. The Data Distribution Service (DDS) will certainly be present in future architectures in some areas as robots, co-bots, and compact units. The current paper proposes a solution to evaluate the real-time coexistence of OPC UA and DDS protocols, functioning in parallel and in a gateway context. The purpose is to confirm the compatibility and feasibility between the two protocols alongside a general definition of criteria and expectations from an architectural point of view, pointing out advantages and disadvantages in a neutral manner, shaping a comprehensive view of the possibilities. The researched architecture is meant to comply with both performance comparison scenarios and interaction scenarios over a gateway application. Considering the industrial tendencies, the developed solution is applied using non-ideal infrastructures to provide a more feasible and faster applicability in the production lines.
Keywords: interoperability; Industry 4.0; industrial internet of things; industrial protocols; OPC UA; DDS; publish-subscribe; real-time interoperability; Industry 4.0; industrial internet of things; industrial protocols; OPC UA; DDS; publish-subscribe; real-time

Share and Cite

MDPI and ACS Style

Ioana, A.; Korodi, A. DDS and OPC UA Protocol Coexistence Solution in Real-Time and Industry 4.0 Context Using Non-Ideal Infrastructure. Sensors 2021, 21, 7760. https://doi.org/10.3390/s21227760

AMA Style

Ioana A, Korodi A. DDS and OPC UA Protocol Coexistence Solution in Real-Time and Industry 4.0 Context Using Non-Ideal Infrastructure. Sensors. 2021; 21(22):7760. https://doi.org/10.3390/s21227760

Chicago/Turabian Style

Ioana, Alexandru, and Adrian Korodi. 2021. "DDS and OPC UA Protocol Coexistence Solution in Real-Time and Industry 4.0 Context Using Non-Ideal Infrastructure" Sensors 21, no. 22: 7760. https://doi.org/10.3390/s21227760

APA Style

Ioana, A., & Korodi, A. (2021). DDS and OPC UA Protocol Coexistence Solution in Real-Time and Industry 4.0 Context Using Non-Ideal Infrastructure. Sensors, 21(22), 7760. https://doi.org/10.3390/s21227760

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop