Next Article in Journal
Colorectal Cancer and Colitis Diagnosis Using Fourier Transform Infrared Spectroscopy and an Improved K-Nearest-Neighbour Classifier
Previous Article in Journal
IMU-Based Gait Recognition Using Convolutional Neural Networks and Multi-Sensor Fusion
Previous Article in Special Issue
Experimental Investigation on the Detection of Multiple Surface Cracks Using Vibrothermography with a Low-Power Piezoceramic Actuator
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Mn-Doped CaBi4Ti4O15/Pb(Zr,Ti)O3 Ultrasonic Transducers for Continuous Monitoring at Elevated Temperatures

1
Faculty of Advanced Science and Technology, Kumamoto University, Kumamoto 860-8555, Japan
2
Department of Electrical Engineering, Tokyo University of Science, Tokyo 162-0825, Japan
*
Author to whom correspondence should be addressed.
Sensors 2017, 17(12), 2740; https://doi.org/10.3390/s17122740
Submission received: 1 November 2017 / Revised: 16 November 2017 / Accepted: 24 November 2017 / Published: 27 November 2017
(This article belongs to the Special Issue Materials and Applications for Sensors and Transducers)

Abstract

Continuous ultrasonic in-situ monitoring for industrial applications is difficult owing to the high operating temperatures in industrial fields. It is expected that ultrasonic transducers consisting of a CaBi4Ti4O15(CBT)/Pb(Zr,Ti)O3(PZT) sol-gel composite could be one solution for ultrasonic nondestructive testing (NDT) above 500 °C because no couplant is required and CBT has a high Curie temperature. To verify the high temperature durability, CBT/PZT sol-gel composite films were fabricated on titanium substrates by spray coating, and the CBT/PZT samples were tested in a furnace at various temperatures. Reflected echoes with a high signal-to-noise ratio were observed up to 600 °C. A thermal cycle test was conducted from room temperature to 600 °C, and no significant deterioration was found after the second thermal cycle. To investigate the long-term high-temperature durability, a CBT/PZT ultrasonic transducer was tested in the furnace at 600 °C for 36 h. Ultrasonic responses were recorded every 3 h, and the sensitivity and signal-to-noise ratio were stable throughout the experiment.
Keywords: ultrasonic transducers; high temperature measurement; nondestructive testing; thin film sensor ultrasonic transducers; high temperature measurement; nondestructive testing; thin film sensor

Share and Cite

MDPI and ACS Style

Kobayashi, M.; Kibe, T.; Nagata, H. Mn-Doped CaBi4Ti4O15/Pb(Zr,Ti)O3 Ultrasonic Transducers for Continuous Monitoring at Elevated Temperatures. Sensors 2017, 17, 2740. https://doi.org/10.3390/s17122740

AMA Style

Kobayashi M, Kibe T, Nagata H. Mn-Doped CaBi4Ti4O15/Pb(Zr,Ti)O3 Ultrasonic Transducers for Continuous Monitoring at Elevated Temperatures. Sensors. 2017; 17(12):2740. https://doi.org/10.3390/s17122740

Chicago/Turabian Style

Kobayashi, Makiko, Taiga Kibe, and Hajime Nagata. 2017. "Mn-Doped CaBi4Ti4O15/Pb(Zr,Ti)O3 Ultrasonic Transducers for Continuous Monitoring at Elevated Temperatures" Sensors 17, no. 12: 2740. https://doi.org/10.3390/s17122740

APA Style

Kobayashi, M., Kibe, T., & Nagata, H. (2017). Mn-Doped CaBi4Ti4O15/Pb(Zr,Ti)O3 Ultrasonic Transducers for Continuous Monitoring at Elevated Temperatures. Sensors, 17(12), 2740. https://doi.org/10.3390/s17122740

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop