Next Article in Journal
Wireless Integrated Biosensors for Point-of-Care Diagnostic Applications
Previous Article in Journal
Frequency Split Elimination Method for a Solid-State Vibratory Angular Rate Gyro with an Imperfect Axisymmetric-Shell Resonator
Article

A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and An Anti-Interference Post Processing Circuit

Institute of Microelectronics and Tsinghua National Laboratory for Information Science and Technology (TNList), Tsinghua University, Beijing 100084, China
*
Author to whom correspondence should be addressed.
These authors contributed equally to this work.
Sensors 2015, 15(2), 3224-3235; https://doi.org/10.3390/s150203224
Received: 11 December 2014 / Accepted: 20 January 2015 / Published: 2 February 2015
(This article belongs to the Section Physical Sensors)
Heart rate measurement is a basic and important issue for either medical diagnosis or daily health monitoring. In this work great efforts have been focused on realizing a portable, comfortable and low cost solution for long-term domestic heart rate monitoring. A tiny but efficient measurement system composed of a polymer-based flexible pressure sensor and an analog anti-interference readout circuit is proposed; manufactured and tested. The proposed polymer-based pressure sensor has a linear response and high sensitivity of 13.4 kPa−1. With the circuit’s outstanding capability in removing interference caused by body movement and the highly sensitive flexible sensor device, comfortable long-term heart rate monitoring becomes more realistic. Comparative tests prove that the proposed system has equivalent capability (accuracy: <3%) in heart rate measurement to the commercial product. View Full-Text
Keywords: heart rate monitoring; flexible sensors; pressure sensors; anti-interference circuit heart rate monitoring; flexible sensors; pressure sensors; anti-interference circuit
Show Figures

MDPI and ACS Style

Shu, Y.; Li, C.; Wang, Z.; Mi, W.; Li, Y.; Ren, T.-L. A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and An Anti-Interference Post Processing Circuit. Sensors 2015, 15, 3224-3235. https://doi.org/10.3390/s150203224

AMA Style

Shu Y, Li C, Wang Z, Mi W, Li Y, Ren T-L. A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and An Anti-Interference Post Processing Circuit. Sensors. 2015; 15(2):3224-3235. https://doi.org/10.3390/s150203224

Chicago/Turabian Style

Shu, Yi, Cheng Li, Zhe Wang, Wentian Mi, Yuxing Li, and Tian-Ling Ren. 2015. "A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and An Anti-Interference Post Processing Circuit" Sensors 15, no. 2: 3224-3235. https://doi.org/10.3390/s150203224