Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (9)

Search Parameters:
Keywords = vaping topography

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 3124 KB  
Article
Quantification of Size-Binned Particulate Matter in Electronic Cigarette Aerosols Using Multi-Spectral Optical Sensing and Machine Learning
by Hao Jiang and Keith Kolaczyk
Sensors 2024, 24(21), 7082; https://doi.org/10.3390/s24217082 - 3 Nov 2024
Viewed by 3033
Abstract
To monitor health risks associated with vaping, we introduce a multi-spectral optical sensor powered by machine learning for real-time characterization of electronic cigarette aerosols. The sensor can accurately measure the mass of particulate matter (PM) in specific particle size channels, providing essential information [...] Read more.
To monitor health risks associated with vaping, we introduce a multi-spectral optical sensor powered by machine learning for real-time characterization of electronic cigarette aerosols. The sensor can accurately measure the mass of particulate matter (PM) in specific particle size channels, providing essential information for estimating lung deposition of vaping aerosols. For the sensor’s input, wavelength-specific optical attenuation signals are acquired for three separate wavelengths in the ultraviolet, red, and near-infrared range, and the inhalation pressure is collected from a pressure sensor. The sensor’s outputs are PM mass in three size bins, specified as 100–300 nm, 300–600 nm, and 600–1000 nm. Reference measurements of electronic cigarette aerosols, obtained using a custom vaping machine and a scanning mobility particle sizer, provided the ground truth for size-binned PM mass. A lightweight two-layer feedforward neural network was trained using datasets acquired from a wide range of puffing conditions. The performance of the neural network was tested using unseen data collected using new combinations of puffing conditions. The model-predicted values matched closely with the ground truth, and the accuracy reached 81–87% for PM mass in three size bins. Given the sensor’s straightforward optical configuration and the direct collection of signals from undiluted vaping aerosols, the achieved accuracy is notably significant and sufficiently reliable for point-of-interest sensing of vaping aerosols. To the best of our knowledge, this work represents the first instance where machine learning has been applied to directly characterize high-concentration undiluted electronic cigarette aerosols. Our sensor holds great promise in tracking electronic cigarette users’ puff topography with quantification of size-binned PM mass, to support long-term personalized health and wellness. Full article
(This article belongs to the Special Issue Optical Spectroscopic Sensing and Imaging)
Show Figures

Graphical abstract

22 pages, 2876 KB  
Article
Photometric Monitoring of Electronic Cigarette Puff Topography
by Keith Kolaczyk and Hao Jiang
Sensors 2023, 23(19), 8220; https://doi.org/10.3390/s23198220 - 2 Oct 2023
Cited by 4 | Viewed by 5379
Abstract
To study and monitor the adverse health consequences of using electronic cigarettes, a user’s puff topography, which are quantification parameters of the user’s vaping habits, plays a central role. In this work, we introduce a topography sensor to measure the mass of total [...] Read more.
To study and monitor the adverse health consequences of using electronic cigarettes, a user’s puff topography, which are quantification parameters of the user’s vaping habits, plays a central role. In this work, we introduce a topography sensor to measure the mass of total particulate matter generated in every puff and to estimate the nicotine yield. The sensor is compact and low-cost, and is integrated into the electronic cigarette device to promptly and conveniently monitor the user’s daily puff topography. The topography sensor is comprised of a photometric sensor and a pressure sensor. The photometric sensor measures the mass concentration of the aerosol, based on scattering of near-infrared light from airborne particles, while the pressure sensor measures the flow rate. The topography sensor was tested under various conditions including a wide range of atomizer power, puff duration, and inhalation pressure. The sensor’s accuracy was validated by comparing the sensor’s readings with reference measurements, and the results matched closely with the trends reported by existing studies on electronic cigarettes. An example application for tracking a user’s puff topography was also demonstrated. Our topography sensor holds great promise in mitigating the health risks of vaping, and in promoting quality control of electronic cigarette products. Full article
Show Figures

Figure 1

12 pages, 1901 KB  
Article
Cytotoxic and Inflammatory Effects of Electronic and Traditional Cigarettes on Oral Gingival Cells Using a Novel Automated Smoking Instrument: An In Vitro Study
by Liza L. Ramenzoni, Andreas Schneider, Stephan C. Fox, Michael Meyer, Mirko Meboldt, Thomas Attin and Patrick R. Schmidlin
Toxics 2022, 10(4), 179; https://doi.org/10.3390/toxics10040179 - 6 Apr 2022
Cited by 20 | Viewed by 4902
Abstract
Information about the potential oral health effects of vaping from electronic cigarettes (e-cigs) is still sparse and inconsistent. The purpose of this study was to compare the safety and cytotoxicity of e-cig liquid aerosols versus traditional cigarette (t-cig) smoke on human epithelial oral [...] Read more.
Information about the potential oral health effects of vaping from electronic cigarettes (e-cigs) is still sparse and inconsistent. The purpose of this study was to compare the safety and cytotoxicity of e-cig liquid aerosols versus traditional cigarette (t-cig) smoke on human epithelial oral cells. T-cig smoke and e-cig aerosols were generated by a newly developed automated smoking instrument in order to simulate realistic user puffing behaviors. Air–liquid interface transwell cell cultures were exposed to standardized puff topography (puff duration: 2 s, puff volume: 35 mL, puff frequency: 1 puff every 60 s) of reference t-cigs or commercially available e-cigs at different air dilutions. Cell viability, morphology, and death rate were evaluated with MTT and TUNEL assays. The inflammatory cytokine gene expression of inflammatory genes was assessed by quantitative RT-PCR. E-cigs and t-cigs indicated similar adverse effects by enhancing cytotoxicity and cell death in a dose-dependent manner. E-cig aerosol and t-cig smoke treatment expressed upregulation of inflammatory cytokines up to 3.0-fold (p < 0.05). These results indicate that e-cig smoking may contribute to oral tissue–cell damage and tissue inflammation. Our approach allows the production of e-cig aerosol and t-cig smoke in order to identify harmful effects in oral tissues in vitro. Full article
(This article belongs to the Section Toxicology)
Show Figures

Figure 1

26 pages, 4467 KB  
Article
Fabrication and Validation of an Economical, Programmable, Dual-Channel, Electronic Cigarette Aerosol Generator
by Dominic L. Palazzolo, Jordan Caudill, James Baron and Kevin Cooper
Int. J. Environ. Res. Public Health 2021, 18(24), 13190; https://doi.org/10.3390/ijerph182413190 - 14 Dec 2021
Cited by 4 | Viewed by 4042
Abstract
Vaping (inhalation of electronic cigarette-generated aerosol) is a public health concern. Due to recent spikes in adolescent use of electronic cigarettes (ECIGs) and vaping-induced illnesses, demand for scientific inquiry into the physiological effects of electronic cigarette (ECIG) aerosol has increased. For such studies, [...] Read more.
Vaping (inhalation of electronic cigarette-generated aerosol) is a public health concern. Due to recent spikes in adolescent use of electronic cigarettes (ECIGs) and vaping-induced illnesses, demand for scientific inquiry into the physiological effects of electronic cigarette (ECIG) aerosol has increased. For such studies, standardized and consistent aerosol production is required. Many labs generate aerosol by manually activating peristaltic pumps and ECIG devices simultaneously in a predefined manner. The tedium involved with this process (large puff number over time) and risk of error in keeping with puff topography (puff number, duration, interval) are less than optimal. Furthermore, excess puffing on an ECIG device results in battery depletion, reducing aerosol production, and ultimately, its chemical and physical nature. While commercial vaping machines are available, the cost of these machines is prohibitive to many labs. For these reasons, an economical and programmable ECIG aerosol generator, capable of generating aerosol from two atomizers simultaneously, was fabricated, and subsequently validated. Validation determinants include measurements of atomizer temperatures (inside and outside), electrical parameters (current, resistance and power) of the circuitry, aerosol particle distribution (particle counts and mass concentrations) and aerosol delivery (indexed by nicotine recovery), all during stressed conditions of four puffs/minute for 75 min (i.e., 300 puffs). Validation results indicate that the ECIG aerosol generator is better suited for experiments involving ≤100 puffs. Over 100 puffs, the amount of variation in the parameters measured tends to increase. Variations between channels are generally higher than variations within a channel. Despite significant variations in temperatures, electrical parameters, and aerosol particle distributions, both within and between channels, aerosol delivery remains remarkably stable for up to 300 puffs, yielding over 25% nicotine recovery for both channels. In conclusion, this programmable, dual-channel ECIG aerosol generator is not only affordable, but also allows the user to control puff topography and eliminate battery drain of ECIG devices. Consequently, this aerosol generator is valid, reliable, economical, capable of using a variety of E-liquids and amenable for use in a vast number of studies investigating the effects of ECIG-generated aerosol while utilizing a multitude of puffing regimens in a standardized manner. Full article
(This article belongs to the Section Environmental Health)
Show Figures

Figure 1

13 pages, 2479 KB  
Article
The Effect of Flow Rate on a Third-Generation Sub-Ohm Tank Electronic Nicotine Delivery System—Comparison of CORESTA Flow Rates to More Realistic Flow Rates
by Evan Floyd, Sara Greenlee, Toluwanimi Oni, Balaji Sadhasivam and Lurdes Queimado
Int. J. Environ. Res. Public Health 2021, 18(14), 7535; https://doi.org/10.3390/ijerph18147535 - 15 Jul 2021
Cited by 11 | Viewed by 3929
Abstract
Many types of electronic cigarettes (ECs) are currently in use, but the default flow rate used to simulate puffing is centered on tobacco cigarette flow rates. CORESTA offers several methods and technical guides for evaluation of ECs but there are few puffing topography [...] Read more.
Many types of electronic cigarettes (ECs) are currently in use, but the default flow rate used to simulate puffing is centered on tobacco cigarette flow rates. CORESTA offers several methods and technical guides for evaluation of ECs but there are few puffing topography studies focusing on sub-ohm ECs; differences between real-world usage and that found in the literature appear large. This study focuses on how power and flow rate affect the nicotine yield of a sub-ohm EC. A puffing system (Puff3rd) has been designed and used to produce and collect EC aerosol. Nicotine yield was measured by GC–MS at three power levels and four flow rates. Data analysis was conducted in SAS using the MIXED procedure. Power, flow rate, and their interaction were all significant predictors of nicotine yield. Nicotine yield increased with both the vaping power and the puff flow rate with significant interaction of the two. Findings indicate that using the current CORESTA flow rate (1100 mL/min) to evaluate third-generation ECs underestimates nicotine yield and likely overestimates pyrolysis products. Real users are expected to have 2–3× the nicotine dose measured at 1100 mL/min, which could confound epidemiological studies seeking to link nicotine delivery to product satisfaction and acceptability. Full article
Show Figures

Figure 1

15 pages, 3312 KB  
Article
Pilot Study to Detect Genes Involved in DNA Damage and Cancer in Humans: Potential Biomarkers of Exposure to E-Cigarette Aerosols
by Samera H. Hamad, Marielle C. Brinkman, Yi-Hsuan Tsai, Namya Mellouk, Kandice Cross, Ilona Jaspers, Pamela I. Clark and Courtney A. Granville
Genes 2021, 12(3), 448; https://doi.org/10.3390/genes12030448 - 22 Mar 2021
Cited by 22 | Viewed by 7108
Abstract
There is a paucity of data on how gene expression enables identification of individuals who are at risk of exposure to carcinogens from e-cigarette (e-cig) vaping; and how human vaping behaviors modify these exposures. This pilot study aimed to identify genes regulated from [...] Read more.
There is a paucity of data on how gene expression enables identification of individuals who are at risk of exposure to carcinogens from e-cigarette (e-cig) vaping; and how human vaping behaviors modify these exposures. This pilot study aimed to identify genes regulated from acute exposure to e-cig using RT-qPCR. Three subjects (2M and 1F) made three visits to the lab (nTOT = 9 visits); buccal and blood samples were collected before and immediately after scripted vaping 20 puffs (nTOT = 18 samples); vaping topography data were collected in each session. Subjects used their own e-cig containing 50:50 propylene glycol (PG):vegetable glycerine (VG) +3–6 mg/mL nicotine. The tumor suppressor TP53 was significantly upregulated in buccal samples. TP53 expression was puff volume and flow rate dependent in both tissues. In blood, the significant downregulation of N-methylpurine DNA glycosylase (MPG), a base excision repair gene, was consistent across all subjects. In addition to DNA repair pathway, cell cycle and cancer pathways were the most enriched pathways in buccal and blood samples, respectively. This pilot study demonstrates that vaping 20 puffs significantly alters expression of TP53 in human tissues; vaping behavior is an important modifier of this response. A larger study is needed to confirm these relationships. Full article
(This article belongs to the Special Issue Molecular Biomarkers of Pulmonary Diseases)
Show Figures

Graphical abstract

14 pages, 1881 KB  
Article
The Impact of Device Settings, Use Patterns, and Flavorings on Carbonyl Emissions from Electronic Cigarettes
by Yeongkwon Son, Clifford Weisel, Olivia Wackowski, Stephan Schwander, Cristine Delnevo and Qingyu Meng
Int. J. Environ. Res. Public Health 2020, 17(16), 5650; https://doi.org/10.3390/ijerph17165650 - 5 Aug 2020
Cited by 27 | Viewed by 7412
Abstract
Health impacts of electronic cigarette (e-cigarette) vaping are associated with the harmful chemicals emitted from e-cigarettes such as carbonyls. However, the levels of various carbonyl compounds under real-world vaping conditions have been understudied. This study evaluated the levels of carbonyl compounds (e.g., formaldehyde, [...] Read more.
Health impacts of electronic cigarette (e-cigarette) vaping are associated with the harmful chemicals emitted from e-cigarettes such as carbonyls. However, the levels of various carbonyl compounds under real-world vaping conditions have been understudied. This study evaluated the levels of carbonyl compounds (e.g., formaldehyde, acetaldehyde, glyoxal, and diacetyl, etc.) under various device settings (i.e., power output), vaping topographies, and e-liquid compositions (i.e., base liquid, flavor types). The results showed that e-vapor carbonyl levels were the highest under higher power outputs. The propylene glycol (PG)-based e-liquids generated higher formaldehyde and acetaldehyde than vegetable glycerin (VG)-based e-liquids. In addition, fruit flavored e-liquids (i.e., strawberry and dragon fruit) generated higher formaldehyde emissions than mint/menthol and creamy/sweet flavored e-liquids. While single-top coils formed 3.5-fold more formaldehyde per puff than conventional cigarette smoking, bottom coils generated 10–10,000 times less formaldehyde per puff. In general, increases in puff volume and longer puff durations generated significantly higher amounts of formaldehyde. While e-cigarettes emitted much lower levels of carbonyl compounds compared to conventional cigarettes, the presence of several toxic carbonyl compounds in e-cigarette vapor may still pose potential health risks for users without smoking history, including youth. Therefore, the public health administrations need to consider the vaping conditions which generated higher carbonyls, such as higher power output with PG e-liquid, when developing e-cigarette product standards. Full article
Show Figures

Graphical abstract

15 pages, 2017 KB  
Article
Carbonyls and Carbon Monoxide Emissions from Electronic Cigarettes Affected by Device Type and Use Patterns
by Yeongkwon Son, Chiranjivi Bhattarai, Vera Samburova and Andrey Khlystov
Int. J. Environ. Res. Public Health 2020, 17(8), 2767; https://doi.org/10.3390/ijerph17082767 - 17 Apr 2020
Cited by 71 | Viewed by 8865
Abstract
Dangerous levels of harmful chemicals in electronic cigarette (e-cigarette) aerosols were reported by several studies, but variability in e-cigarette design and use patterns, and a rapid development of new devices, such as JUUL, hamper efforts to develop standardized testing protocols and understand health [...] Read more.
Dangerous levels of harmful chemicals in electronic cigarette (e-cigarette) aerosols were reported by several studies, but variability in e-cigarette design and use patterns, and a rapid development of new devices, such as JUUL, hamper efforts to develop standardized testing protocols and understand health risks associated with e-cigarette use. In this study, we investigated the relative importance of e-cigarette design, power output, liquid composition, puff topography on e-cigarette emissions of carbonyl compounds, carbon monoxide (CO), and nicotine. Four popular e-cigarette devices representing the most common e-cigarette types (e.g., cig-a-like, top-coil, ‘mod’, and ‘pod’) were tested. Under the tested vaping conditions, a top-coil device generated the highest amounts of formaldehyde and CO. A ‘pod’ type device (i.e., JUUL) emitted the highest amounts of nicotine, while generating the lowest levels of carbonyl and CO as compared to other tested e-cigarettes. Emissions increased nearly linearly with puff duration, while puff flow had a relatively small effect. Flavored e-liquids generated more carbonyls and CO than unflavored liquids. Carbonyl concentrations and CO in e-cigarette aerosols were found to be well correlated. While e-cigarettes emitted generally less CO and carbonyls than conventional cigarettes, daily carbonyl exposures from e-cigarette use could still exceed acute exposure limits, with the top-coil device potentially posing more harm than conventional cigarettes. Full article
(This article belongs to the Section Environmental Health)
Show Figures

Graphical abstract

15 pages, 572 KB  
Article
Evaluation of Electronic Cigarette Use (Vaping) Topography and Estimation of Liquid Consumption: Implications for Research Protocol Standards Definition and for Public Health Authorities’ Regulation
by Konstantinos E. Farsalinos, Giorgio Romagna, Dimitris Tsiapras, Stamatis Kyrzopoulos and Vassilis Voudris
Int. J. Environ. Res. Public Health 2013, 10(6), 2500-2514; https://doi.org/10.3390/ijerph10062500 - 18 Jun 2013
Cited by 242 | Viewed by 69994
Abstract
Background: Although millions of people are using electronic cigarettes (ECs) and research on this topic has intensified in recent years, the pattern of EC use has not been systematically studied. Additionally, no comparative measure of exposure and nicotine delivery between EC and [...] Read more.
Background: Although millions of people are using electronic cigarettes (ECs) and research on this topic has intensified in recent years, the pattern of EC use has not been systematically studied. Additionally, no comparative measure of exposure and nicotine delivery between EC and tobacco cigarette or nicotine replacement therapy (NRTs) has been established. This is important, especially in the context of the proposal for a new Tobacco Product Directive issued by the European Commission. Methods: A second generation EC device, consisting of a higher capacity battery and tank atomiser design compared to smaller cigarette-like batteries and cartomizers, and a 9 mg/mL nicotine-concentration liquid were used in this study. Eighty subjects were recruited; 45 experienced EC users and 35 smokers. EC users were video-recorded when using the device (ECIG group), while smokers were recorded when smoking (SM-S group) and when using the EC (SM-E group) in a randomized cross-over design. Puff, inhalation and exhalation duration were measured. Additionally, the amount of EC liquid consumed by experienced EC users was measured at 5 min (similar to the time needed to smoke one tobacco cigarette) and at 20 min (similar to the time needed for a nicotine inhaler to deliver 4 mg nicotine). Results: Puff duration was significantly higher in ECIG (4.2 ± 0.7 s) compared to SM-S (2.1 ± 0.4 s) and SM-E (2.3 ± 0.5 s), while inhalation time was lower (1.3 ± 0.4, 2.1 ± 0.4 and 2.1 ± 0.4 respectively). No difference was observed in exhalation duration. EC users took 13 puffs and consumed 62 ± 16 mg liquid in 5 min; they took 43 puffs and consumed 219 ± 56 mg liquid in 20 min. Nicotine delivery was estimated at 0.46 ± 0.12 mg after 5 min and 1.63 ± 0.41 mg after 20 min of use. Therefore, 20.8 mg/mL and 23.8 mg/mL nicotine-containing liquids would deliver 1 mg of nicotine in 5 min and 4 mg nicotine in 20 min, respectively. Since the ISO method significantly underestimates nicotine delivery by tobacco cigarettes, it seems that liquids with even higher than 24 mg/mL nicotine concentration would be comparable to one tobacco cigarette. Conclusions: EC use topography is significantly different compared to smoking. Four-second puffs with 20–30 s interpuff interval should be used when assessing EC effects in laboratory experiments, provided that the equipment used does not get overheated. Based on the characteristics of the device used in this study, a 20 mg/mL nicotine concentration liquid would be needed in order to deliver nicotine at amounts similar to the maximum allowable content of one tobacco cigarette (as measured by the ISO 3308 method). The results of this study do not support the statement of the European Commission Tobacco Product Directive that liquids with nicotine concentration of 4 mg/mL are comparable to NRTs in the amount of nicotine delivered to the user. Full article
Show Figures

Figure 1

Back to TopTop