Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = spin-exchange relaxation-free (SERF) co-magnetometer

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 1179 KiB  
Article
Transient Heat Transfer Modeling of SERF Co-Magnetometer Atomic Ensemble Based on the Thermoelectric Analogy Method
by Jiaqi Wu, Feng Liu, Lihong Duan, Shaowei Lv, Xihui Dou and Wei Quan
Photonics 2025, 12(3), 224; https://doi.org/10.3390/photonics12030224 - 28 Feb 2025
Viewed by 552
Abstract
Bias instability is one of the most critical factors in the performance of spin-exchange relaxation-free (SERF) co-magnetometers. Previous studies on SERF co-magnetometers have shown that changes in the atomic ensemble temperature can lead to variations in the alkali metal atom density, which in [...] Read more.
Bias instability is one of the most critical factors in the performance of spin-exchange relaxation-free (SERF) co-magnetometers. Previous studies on SERF co-magnetometers have shown that changes in the atomic ensemble temperature can lead to variations in the alkali metal atom density, which in turn affect the optical rotation angle and light shift, ultimately influencing the system’s stability. Building on this understanding, this paper introduces the thermoelectric analogy method for the first time in the transient heat transfer analysis of SERF co-magnetometer atomic ensembles. Using this method, the primary factors affecting the atomic ensemble temperature in a SERF co-magnetometer were analyzed, and transient heat transfer models were established for the following processes: the interaction between the non-magnetic electric heating system and the atomic ensemble temperature, laser heating of the atomic ensemble by the optical system, and the effect of environmental temperature changes on the non-magnetic electric heating system. These models were experimentally validated through active temperature variation experiments. The experimental results show that the proposed transient heat transfer models accurately describe the related heat transfer processes of the atomic ensemble, with model fitting accuracy exceeding 98%. This lays a solid foundation for the high-precision closed-loop control of the atomic ensemble temperature in SERF co-magnetometers and provides valuable insights for the structural design and engineering applications of SERF co-magnetometers. Full article
(This article belongs to the Special Issue Quantum Enhanced Devices and Instruments for Sensing Applications)
Show Figures

Figure 1

13 pages, 1203 KiB  
Article
Enhancing Dynamic Performance in K-Rb-21Ne Co-Magnetometers through Atomic Density Optimization
by Lv Yang, Haoying Pang and Wei Quan
Photonics 2024, 11(2), 182; https://doi.org/10.3390/photonics11020182 - 16 Feb 2024
Cited by 1 | Viewed by 1556
Abstract
The K-Rb-21Ne co-magnetometer exhibits poorer dynamic performance due to the larger equivalent magnetic field generated by alkali metal atoms. In this study, the impact of the atomic number density of alkali metal atoms and noble gas atoms in the cell on [...] Read more.
The K-Rb-21Ne co-magnetometer exhibits poorer dynamic performance due to the larger equivalent magnetic field generated by alkali metal atoms. In this study, the impact of the atomic number density of alkali metal atoms and noble gas atoms in the cell on the dynamic performance of the atomic ensemble is investigated quantitatively. Relationships between the slow-decay term in the transient response attenuation of the Spin-Exchange Relaxation-Free (SERF) co-magnetometer to interference magnetic fields and the number densities of noble gas atoms as well as alkali metal atoms are established. Based on the established model, the relationship between the number density of 21Ne atoms and dynamic performance is investigated using cells with five different noble gas pressures. Then, we investigate the impact of the number density of alkali metal atoms using a cell with a pressure of 2.1 atm at different temperatures. The results indicate that, as the number density of alkali metal atoms or noble gas atoms in the cell increases, the dynamic performance of the system improves, which provides a theoretical basis for the design of cell parameters for SERF co-magnetometers. Full article
Show Figures

Figure 1

14 pages, 1661 KiB  
Article
In-Situ Detection for Atomic Density in the K-Rb-21Ne Co-Magnetometer via an Optical Heterodyne Interferometry
by Sixun Liu, Zhuo Wang and Yueyang Zhai
Photonics 2023, 10(10), 1091; https://doi.org/10.3390/photonics10101091 - 28 Sep 2023
Cited by 5 | Viewed by 1362
Abstract
The low-frequency fluctuations of the atomic density within the cell can induce the longterm drift of the K-Rb-21Ne spin-exchange relaxation-free (SERF) co-magnetometer output, such that the accurate measurement of in situ atomic density is of great significance for improving the performance [...] Read more.
The low-frequency fluctuations of the atomic density within the cell can induce the longterm drift of the K-Rb-21Ne spin-exchange relaxation-free (SERF) co-magnetometer output, such that the accurate measurement of in situ atomic density is of great significance for improving the performance of co-magnetometer. In this paper, the complex refractive index model of the spin ensembles under the hybrid optical pumping condition is established first, according to which the relation between atomic density and its complex refractive index is revealed and an optical heterodyne-based scheme for atomic density detection is proposed. The dependence of the atomic density on the demodulated phase signal from the optical heterodyne-based scheme is provided by numerical simulations. After that, a dual acousto-optics frequency shifter (AOFS)-based optical heterodyne interferometry is constructed with a noise level below 1 mrad/Hz for frequencies > 1 Hz, and a compact SERF co-magnetometer is implemented as the testing medium, by which the atomic density detection with resolution of 0.40 K @ 473 K is reached and the experimental results agree well with theoretical simulations. Moreover, the detection scheme proposed in this paper has the properties of high detection sensitivity and immunity to laser power fluctuation, which are also proved experimentally. Full article
Show Figures

Figure 1

16 pages, 2822 KiB  
Article
Precise Determination of Magnetic Gradient Relaxation of Coupled Atomic Spin Ensemble in Spin-Exchange Relaxation-Free Co-Magnetometer
by Xiujie Fang, Kai Wei, Wenfeng Fan, Siran Li, Qian Cao, Wei Quan, Yueyang Zhai and Zhisong Xiao
Photonics 2023, 10(4), 400; https://doi.org/10.3390/photonics10040400 - 3 Apr 2023
Cited by 2 | Viewed by 1942
Abstract
Inside a spin-exchange relaxation-free (SERF) co-magnetometer with a high-pressure buffer gas atomic cell, the magnetic field gradient causes the decoherence of atomic spins to produce magnetic-field gradient relaxation. This paper presents a new method for the accurate measurement of magnetic field gradient relaxation [...] Read more.
Inside a spin-exchange relaxation-free (SERF) co-magnetometer with a high-pressure buffer gas atomic cell, the magnetic field gradient causes the decoherence of atomic spins to produce magnetic-field gradient relaxation. This paper presents a new method for the accurate measurement of magnetic field gradient relaxation of alkali metal atoms and inert atoms of strongly coupled spin systems under triaxial magnetic field gradients in the K-Rb-21Ne co-magnetometer. The magnetic field gradient relaxation of alkali metal atoms is measured using a step magnetic field modulation method, and the magnetic field gradient relaxation of inert atoms is measured using a combined free induction decay and spin growth method. The method does not require the use of large background magnetic fields and RF fields to maintain the atoms in the SERF state, does not require additional optics, and is not affected by the pumping or detecting of optical power. A kinetic model that considers a large electron-equivalent magnetic field was designed and a gradient relaxation model was developed. The quadratic coefficients of the experimentally measured gradient relaxation curves fit the theoretical model well over the range of the applied magnetic field gradients, confirming the validity of the proposed method. Full article
(This article belongs to the Special Issue Optically Pumped Magnetometer and Its Application)
Show Figures

Figure 1

11 pages, 4907 KiB  
Article
Study on the Magnetic Noise Characteristics of Amorphous and Nanocrystalline Inner Magnetic Shield Layers of SERF Co-Magnetometer
by Ye Liu, Hang Gao, Longyan Ma, Jiale Quan, Wenfeng Fan, Xueping Xu, Yang Fu, Lihong Duan and Wei Quan
Materials 2022, 15(22), 8267; https://doi.org/10.3390/ma15228267 - 21 Nov 2022
Cited by 14 | Viewed by 2554
Abstract
With the widespread use of magneto-sensitive elements, magnetic shields are an important part of electronic equipment, ultra-sensitive atomic sensors, and in basic physics experiments. Particularly in Spin-exchange relaxation-free (SERF) co-magnetometers, the magnetic shield is an important component for maintaining the SERF state. However, [...] Read more.
With the widespread use of magneto-sensitive elements, magnetic shields are an important part of electronic equipment, ultra-sensitive atomic sensors, and in basic physics experiments. Particularly in Spin-exchange relaxation-free (SERF) co-magnetometers, the magnetic shield is an important component for maintaining the SERF state. However, the inherent noise of magnetic shield materials is an important factor limiting the measurement sensitivity and accuracy of SERF co-magnetometers. In this paper, both amorphous and nanocrystalline materials were designed and applied as the innermost magnetic shield of an SERF co-magnetometer. Magnetic noise characteristics of different amorphous and nanocrystalline materials used as the internal magnetic shielding layer of the magnetic shielding system were analyzed. In addition, the effects on magnetic noise due to adding aluminum to amorphous and nanocrystalline materials were studied. The experimental results show that compared with an amorphous material, a nanocrystalline material as the inner magnetic shield layer can effectively reduce the magnetic noise and improve the sensitivity and precision of the rotation measurement. Nanocrystalline material is very promising for inner shield composition in SERF co-magnetometers. Furthermore, its ultra-thin structure and low cost have significant application value in the miniaturization of SERF co-magnetometers. Full article
(This article belongs to the Special Issue Soft Magnetic Materials and Their Application)
Show Figures

Figure 1

10 pages, 1948 KiB  
Article
Analysis and Suppression of Thermal Magnetic Noise of Ferrite in the SERF Co-Magnetometer
by Haoying Pang, Feng Liu, Wengfeng Fan, Jiaqi Wu, Qi Yuan, Zhihong Wu and Wei Quan
Materials 2022, 15(19), 6971; https://doi.org/10.3390/ma15196971 - 7 Oct 2022
Cited by 10 | Viewed by 2174
Abstract
The ferrite magnetic shield is widely used in ultra-high-sensitivity atomic sensors because of its low noise characteristics. However, its noise level varies with temperature and affects the performance of the spin-exchange relaxation-free (SERF) co-magnetometer. Therefore, it is necessary to analyze and suppress the [...] Read more.
The ferrite magnetic shield is widely used in ultra-high-sensitivity atomic sensors because of its low noise characteristics. However, its noise level varies with temperature and affects the performance of the spin-exchange relaxation-free (SERF) co-magnetometer. Therefore, it is necessary to analyze and suppress the thermal magnetic noise. In this paper, the thermal magnetic noise model of a ferrite magnetic shield is established, and the thermal magnetic noise of ferrite is calculated more accurately by testing the low-frequency complex permeability at different temperatures. A temperature suppression method based on the improved heat dissipation efficiency of the ferrite magnetic shield is also proposed. The magnetic noise of the ferrite is reduced by 46.7%. The experiment is basically consistent with the theory. The sensitivity of the co-magnetometer is decreased significantly, from 1.21 × 105°/s/Hz1/2 to 7.02 × 106°/s/Hz1/2 at 1 Hz. The experimental results demonstrate the effectiveness of the proposed method. In addition, the study is also helpful for evaluating the thermal magnetic noise of other materials. Full article
(This article belongs to the Special Issue Soft Magnetic Materials and Their Application)
Show Figures

Figure 1

Back to TopTop