Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (7)

Search Parameters:
Keywords = side-polished POF

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 2318 KB  
Article
A Flexible Wearable Data Glove Based on Hybrid Fiber-Optic Sensing for Hand Motion Monitoring
by Jing Li, Xiangting Hou, Ke Du, Huiying Piao and Cheng Li
Materials 2026, 19(8), 1525; https://doi.org/10.3390/ma19081525 - 10 Apr 2026
Viewed by 557
Abstract
Wearable data gloves often suffer from electromagnetic interference, insufficient substrate stability, and limited capability for multi-degree-of-freedom motion measurement. To address these limitations, a flexible glove incorporating a hybrid POF-FBG sensing scheme was designed and fabricated. Plastic optical fibers (POFs) were side-polished and patterned [...] Read more.
Wearable data gloves often suffer from electromagnetic interference, insufficient substrate stability, and limited capability for multi-degree-of-freedom motion measurement. To address these limitations, a flexible glove incorporating a hybrid POF-FBG sensing scheme was designed and fabricated. Plastic optical fibers (POFs) were side-polished and patterned with long-period gratings to improve sensitivity to wrist flexion-extension and abduction-adduction. Then fiber Bragg gratings (FBGs) were embedded in a polydimethylsiloxane substrate and encapsulated using thermoplastic polyurethane fixtures to reduce the influence of skin stretching and improve measurement accuracy of finger-joint angle. Moreover, a thermoplastic polyurethane skeleton with an adaptive sliding-rail structure was 3D printed to maintain the stability of the sensor placement at the joints. Experimental results demonstrated the mean absolute errors of 4.06°, 1.38° and 1.70° for wrist flexion-extension, abduction-adduction and finger-joint bending, respectively, along with excellent gesture classification using a support vector machine algorithm, which indicates great potential in virtual reality interaction and hand rehabilitation applications. Full article
(This article belongs to the Special Issue Advances in Optical Fiber Materials and Their Applications)
Show Figures

Figure 1

8 pages, 1845 KB  
Article
Sensitivity Enhancement of Polymer Optical Fiber Surface Plasmon Resonance Sensor Utilizing ITO Overlayer
by Getinet Woyessa and Ole Bang
Sensors 2025, 25(6), 1863; https://doi.org/10.3390/s25061863 - 17 Mar 2025
Cited by 9 | Viewed by 1986
Abstract
We present an experimental study of a sensitivity-enhanced surface plasmon resonance (SPR) sensor utilizing a cladding etched multimode polymer optical fiber (POF) coated with a layer of gold followed by an indium tin oxide (ITO) layer. Our findings indicate that POF SPR sensors [...] Read more.
We present an experimental study of a sensitivity-enhanced surface plasmon resonance (SPR) sensor utilizing a cladding etched multimode polymer optical fiber (POF) coated with a layer of gold followed by an indium tin oxide (ITO) layer. Our findings indicate that POF SPR sensors with an ITO overlayer exhibit higher sensitivity compared to those coated solely with gold. Additionally, increasing the thickness of the ITO layer increases the sensitivity of the sensor at the expense of a broader SPR spectrum. We determined that the optimal ITO thickness for maximizing sensitivity is 25 nm. The sensor coated with 40 nm gold and 25 nm ITO demonstrated a refractive index sensitivity of 2258 nm per refractive index unit (nm/RIU) with a figure of merit and resolution of 10.13 RIU1 and 2.74×104 RIU, respectively, within the range of 1.33 to 1.37 RIU. Notably, this sensitivity is 70% greater than that of a POF SPR sensor coated only with 40 nm gold. Long-term stability tests conducted in a hydrated environment confirmed that the ITO layer remains unaffected over time and that the maximum SPR wavelength drift was only 1.2 nm. The standard deviation of the three-round measurements also revealed that the sensor has good repeatability. We believe that this sensor offers a simple structure and a relatively easy fabrication process, eliminating the need for side polishing while providing a large interaction area, making it a promising candidate for high-sensitivity biosensing applications. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

11 pages, 9936 KB  
Communication
Side-Polish Plastic Optical Fiber Based SPR Sensor for Refractive Index and Liquid-Level Sensing
by Chuanxin Teng, Shiyuan Ying, Rui Min, Shijie Deng, Hongchang Deng, Ming Chen, Xiaoxue Chu, Libo Yuan, Yu Cheng and Minmin Xue
Sensors 2022, 22(16), 6241; https://doi.org/10.3390/s22166241 - 19 Aug 2022
Cited by 22 | Viewed by 4535
Abstract
In this work, a simple side-polish plastic optical fiber (POF)-based surface plasmon resonance (SPR) sensor is proposed and demonstrated for simultaneous measurement of refractive index (RI) and liquid level. The effects of side-polish depths on the sensing performance were studied. The experimental results [...] Read more.
In this work, a simple side-polish plastic optical fiber (POF)-based surface plasmon resonance (SPR) sensor is proposed and demonstrated for simultaneous measurement of refractive index (RI) and liquid level. The effects of side-polish depths on the sensing performance were studied. The experimental results show that the SPR peak wavelength will be changed as the RI changes, and the SPR peak intensity will be changed with the liquid level variation. By monitoring the changes in peak wavelength and intensity, the RI and liquid level can be detected simultaneously. Experimental results show that an RI sensitivity of 2008.58 nm/RIU can be reached at an RI of 1.39. This sensor has the advantages of simple structure and low cost, which has a good prospect in the field of biochemical sensing. Full article
(This article belongs to the Special Issue Polymer Optical Fibers for Sensing Applications)
Show Figures

Figure 1

20 pages, 48508 KB  
Review
Intensity-Modulated Polymer Optical Fiber-Based Refractive Index Sensor: A Review
by Chuanxin Teng, Rui Min, Jie Zheng, Shijie Deng, Maosen Li, Li Hou and Libo Yuan
Sensors 2022, 22(1), 81; https://doi.org/10.3390/s22010081 - 23 Dec 2021
Cited by 56 | Viewed by 8896
Abstract
The simple and highly sensitive measurement of the refractive index (RI) of liquids is critical for designing the optical instruments and important in biochemical sensing applications. Intensity modulation-based polymer optical fiber (POF) RI sensors have a lot of advantages including low cost, easy [...] Read more.
The simple and highly sensitive measurement of the refractive index (RI) of liquids is critical for designing the optical instruments and important in biochemical sensing applications. Intensity modulation-based polymer optical fiber (POF) RI sensors have a lot of advantages including low cost, easy fabrication and operation, good flexibility, and working in the visible wavelength. In this review, recent developments of the intensity modulation POF-based RI sensors are summarized. The materials of the POF and the working principle of intensity modulation are introduced briefly. Moreover, the RI sensing performance of POF sensors with different structures including tapered, bent, and side-polished structures, among others, are presented in detail. Finally, the sensing performance for different structures of POF-based RI sensors are compared and discussed. Full article
(This article belongs to the Special Issue Instrument and Measurement Based on Sensing Technology in China)
Show Figures

Figure 1

12 pages, 4174 KB  
Communication
An Enhanced Plastic Optical Fiber-Based Surface Plasmon Resonance Sensor with a Double-Sided Polished Structure
by Lian Liu, Shijie Deng, Jie Zheng, Libo Yuan, Hongchang Deng and Chuanxin Teng
Sensors 2021, 21(4), 1516; https://doi.org/10.3390/s21041516 - 22 Feb 2021
Cited by 50 | Viewed by 5289
Abstract
An enhanced plastic optical fiber (POF)-based surface plasmon resonance (SPR) sensor is proposed by employing a double-sided polished structure. The sensor is fabricated by polishing two sides of the POF symmetrically along with the fiber axis, and a layer of Au film is [...] Read more.
An enhanced plastic optical fiber (POF)-based surface plasmon resonance (SPR) sensor is proposed by employing a double-sided polished structure. The sensor is fabricated by polishing two sides of the POF symmetrically along with the fiber axis, and a layer of Au film is deposited on each side of the polished region. The SPR can be excited on both polished surfaces with Au film coating, and the number of light reflections will be increased by using this structure. The simulation and experimental results show that the proposed sensor has an enhanced SPR effect. The visibility and full width at half maximum (FWHM) of spectrum can be improved for the high measured refractive index (RI). A sensitivity of 4284.8 nm/RIU is obtained for the double-sided POF-based SPR sensor when the measured liquid RI is 1.42. The proposed SPR sensor is easy fabrication and low cost, which can provide a larger measurement range and action area to the measured samples, and it has potential application prospects in the oil industry and biochemical sensing fields. Full article
(This article belongs to the Special Issue Recent Development and Applications of Plastic Optical Fiber Sensors)
Show Figures

Figure 1

13 pages, 3260 KB  
Letter
Refractive Index Sensor Based on Double Side-Polished U-Shaped Plastic Optical Fiber
by Shumin Wang, Daming Zhang, Yan Xu, Siwen Sun and Xiaoqiang Sun
Sensors 2020, 20(18), 5253; https://doi.org/10.3390/s20185253 - 14 Sep 2020
Cited by 47 | Viewed by 5732
Abstract
A U-shaped double-side polished plastic optical fiber (POF) is demonstrated as a liquid refractive index (RI) sensor. The refractive index of glycerinum solutions is identified by the intensity detection on the bending and evanescent wave loss change. Heat treatment and mechanical polishing are [...] Read more.
A U-shaped double-side polished plastic optical fiber (POF) is demonstrated as a liquid refractive index (RI) sensor. The refractive index of glycerinum solutions is identified by the intensity detection on the bending and evanescent wave loss change. Heat treatment and mechanical polishing are adopted to form the symmetrical side-polished POF probe. The processing parameters are experimentally optimized on the power transmittance. The sensitivity of 1541%/RIU (Refractive Index Unit) can be obtained with a resolution of 5.35 × 10−4 in the scope of 1.33–1.39. The favorable temperature characteristic is proved to offer stable RI sensing from 20 to 50 °C. This simple POF sensor has potentials in low-cost visible light intensity RI detection. Full article
(This article belongs to the Special Issue Specialty Polymer Optical Fibers and Sensors)
Show Figures

Figure 1

15 pages, 2592 KB  
Article
Wearable Wrist Movement Monitoring Using Dual Surface-Treated Plastic Optical Fibers
by Jing Li, Jian Liu, Cheng Li, Hui Zhang and Yizuo Li
Materials 2020, 13(15), 3291; https://doi.org/10.3390/ma13153291 - 24 Jul 2020
Cited by 31 | Viewed by 3783
Abstract
Regarding high-sensitivity human wrist joint motion monitoring in exercise rehabilitation; we develop a pair of novel wearable and sensitivity-enhanced plastic optical fiber (POF) strain sensors consisting of an etched grating fiber and a side-polished fiber stitched into a polyamide wrist brace. The two [...] Read more.
Regarding high-sensitivity human wrist joint motion monitoring in exercise rehabilitation; we develop a pair of novel wearable and sensitivity-enhanced plastic optical fiber (POF) strain sensors consisting of an etched grating fiber and a side-polished fiber stitched into a polyamide wrist brace. The two flexible and surface-treated fibers are; respectively; featured with an etched periodic gratings with a pitch of 6 mm and a depth of 0.5 mm and a D-shaped side-polished zone of ~300 µm depth and ~30 mm length; which, correspondingly, show the sensitivities of around 0.0176/° and 0.0167/° in a normalized bending angle by far larger than a conventional commercial POF, because it achieves a more sensitive strain-induced evanescent field interaction with the side-machined fibers. Moreover, in terms of the sensor response to bending deformation in the range of −40°~+40°, the former exhibits a better sensitivity in lower angle change, while the latter is superior as the bending angle increases; thereby arranging the two modified POFs separately at the side and back of the human wrist, in order to decouple the wrist joint behaviors induced by typical flexion-extension or abduction-adduction movements. Then, the circular and pentagonal wrist motion trajectory patterns are investigated, to demonstrate the maximum average single-axis motion error of 2.94° via the transformation of spatial angle to plane coordinate for the fabricated couple of POF sensors, which is lower than a recognized standard of 5°, thus suggesting the great potential in wearable exercise rehabilitation of human joints in the field of medical treatment and healing. Full article
Show Figures

Figure 1

Back to TopTop