Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = removable thermoplastic appliance

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 6782 KiB  
Article
Effect of the Height of a 3D-Printed Model on the Force Transmission and Thickness of Thermoformed Orthodontic Aligners
by Omar Ghoraba, Christoph Bourauel, Mostafa Aldesoki, Lamia Singer, Ahmed M. Ismail, Hanaa Elattar, Abdulaziz Alhotan and Tarek M. Elshazly
Materials 2024, 17(12), 3019; https://doi.org/10.3390/ma17123019 - 20 Jun 2024
Cited by 1 | Viewed by 2020
Abstract
This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness. Forty aligner sheets (Zendura FLX) were thermoformed over four models of varying heights (15, 20, 25, and 30 [...] Read more.
This research aims to investigate the influence of model height employed in the deep drawing of orthodontic aligner sheets on force transmission and aligner thickness. Forty aligner sheets (Zendura FLX) were thermoformed over four models of varying heights (15, 20, 25, and 30 mm). Normal contact force generated on the facial surface of the upper right central incisor (Tooth 11) was measured using pressure-sensitive films. Aligner thickness around Tooth 11 was measured at five points. A digital caliper and a micro-computed tomography (µ-CT) were employed for thickness measurements. The normal contact force exhibited an uneven distribution across the facial surface of Tooth 11. Model 15 displayed the highest force (88.9 ± 23.2 N), while Model 30 exhibited the lowest (45.7 ± 15.8 N). The force distribution was more favorable for bodily movement with Model 15. Thickness measurements revealed substantial thinning of the aligner after thermoforming. This thinning was most pronounced at the incisal edge (50% of the original thickness) and least at the gingivo-facial part (85%). Additionally, there was a progressive reduction in aligner thickness with increasing model height, which was most significant on the facial tooth surfaces. We conclude that the thermoplastic aligner sheets undergo substantial thinning during the thermoforming process, which becomes more pronounced as the height of the model increases. As a result, there is a decrease in both overall and localized force transmission, which could lead to increased tipping by the aligner and a diminished ability to achieve bodily movement. Full article
(This article belongs to the Special Issue Orthodontic Materials: Properties and Effectiveness of Use)
Show Figures

Figure 1

10 pages, 1331 KiB  
Article
Effect of Aging of Orthodontic Aligners in Different Storage Media on Force and Torque Generation: An In Vitro Study
by Tarek M. Elshazly, Diva Nang, Bijan Golkhani, Hanaa Elattar and Christoph Bourauel
Oral 2023, 3(1), 67-76; https://doi.org/10.3390/oral3010007 - 1 Feb 2023
Cited by 9 | Viewed by 3293
Abstract
The aim of this study is to study the effect of aging in different media (deionized water and artificial saliva) on the force/torque generation by thermoplastic orthodontic aligners. Ten thermoformed aligners, made of Essix ACE® thermoplastic sheets, were aged in deionized water [...] Read more.
The aim of this study is to study the effect of aging in different media (deionized water and artificial saliva) on the force/torque generation by thermoplastic orthodontic aligners. Ten thermoformed aligners, made of Essix ACE® thermoplastic sheets, were aged in deionized water and in artificial saliva over two weeks at 37 °C, five in each medium. The force/torque generated on upper second premolar (Tooth 25) of a resin model was measured at day 0 (before aging), 2, 4, 6, 10, and 14, using a biomechanical test set-up. The results showed that aging of aligners by storage in aging agent has no significant impact on their force/torque decay. No significant differences were also found in force/torque between the aligners stored in deionized water nor artificial saliva. The vertical extrusion-intrusion forces were measured in the range of 1.4 to 4.6 N, the horizontal oro-vestibular forces were 1.3 to 2.5 N, while the torques on mesio-distal rotation were 5.4 to 41.7 Nmm. It could be concluded that the influence of saliva only on the mechanical properties can be classified as insignificant, and no significant difference between artificial aging in deionized water or artificial saliva was observed. Full article
Show Figures

Figure 1

13 pages, 1285 KiB  
Article
Surface Evaluation of Aligners after Immersion in Coca-Cola and Orange Juice
by Maciej Warnecki, Michał Sarul, Marcin Kozakiewicz, Anna Zięty, Bartosz Babiarczuk, Beata Kawala and Kamil Jurczyszyn
Materials 2022, 15(18), 6341; https://doi.org/10.3390/ma15186341 - 13 Sep 2022
Cited by 9 | Viewed by 2436
Abstract
Orthodontic removable appliances made of transparent thermoplastic materials—aligners—are becoming increasingly popular in contemporary orthodontic practice. It is important for the clinician to fully understand the mechanical properties and behavior of the appliance used. Because of that, the aim of our study was to [...] Read more.
Orthodontic removable appliances made of transparent thermoplastic materials—aligners—are becoming increasingly popular in contemporary orthodontic practice. It is important for the clinician to fully understand the mechanical properties and behavior of the appliance used. Because of that, the aim of our study was to investigate the changes in aligner surface after immersion in Coca-Cola and orange juice. For surface evaluation, fractal analysis, texture analysis, and wetting angle measurement were performed. Statistically significant changes were found between some of the groups in the fractal dimension analysis. In texture analysis, all but one intergroup comparison showed statistically significant differences. For wetting angle assessment, statistically significant differences were found. These were, however, more numerous when assessing glycol droplets, rather than water droplets. Fractal dimension analysis confirmed a correlation between the intensity of changes in the aligner surface with immersion time in the liquids assessed. Texture analysis showed a high sensitivity to the changes in aligner surface. It failed, however, to reveal changes relative to immersion time. Wetting angle analysis revealed aligner surface degradation for Coca-Cola. It did not, however, prove the dependence of the intensity of this degradation as a function of time. Both Coca-Cola and orange juice can cause aligner surface degradation. Full article
(This article belongs to the Special Issue Numerical Analysis in Medicine and Its Application in Biomaterials)
Show Figures

Figure 1

11 pages, 1347 KiB  
Review
Antimicrobial Activity of Various Disinfectants to Clean Thermoplastic Polymeric Appliances in Orthodontics
by Kanket Kiatwarawut, Dinesh Rokaya and Irin Sirisoontorn
Polymers 2022, 14(11), 2256; https://doi.org/10.3390/polym14112256 - 31 May 2022
Cited by 11 | Viewed by 4085
Abstract
There is a lack of research evidence on the risk–benefits of the various disinfectants in cleaning products and cleansing regimens. This systematic review compared the antimicrobial activity of various chemical disinfectants to disinfect the thermoplastic polymeric appliances in orthodontics. The study was carried [...] Read more.
There is a lack of research evidence on the risk–benefits of the various disinfectants in cleaning products and cleansing regimens. This systematic review compared the antimicrobial activity of various chemical disinfectants to disinfect the thermoplastic polymeric appliances in orthodontics. The study was carried out using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and Cochrane Handbook of Systematic Reviews of Interventions. An electronic search was conducted on Pubmed, Google Scholar, Scopus, ScienceDirect, and Springer. Two authors independently investigated the risk of bias in duplication. A total of 225 articles were collected. After removing duplicates, 221 articles remained, and after filtering their titles and abstracts, 11 articles met eligibility qualifications remained. Finally, nine articles that met the criteria were selected. It showed that both over-the-counter orthodontic appliance cleaners and applied-chemical disinfectants were effective against bacteria. The duration and frequency of usage guidelines cannot be concluded. Full article
Show Figures

Figure 1

11 pages, 1250 KiB  
Review
Direct 3D Printing of Clear Orthodontic Aligners: Current State and Future Possibilities
by Gianluca M. Tartaglia, Andrea Mapelli, Cinzia Maspero, Tommaso Santaniello, Marco Serafin, Marco Farronato and Alberto Caprioglio
Materials 2021, 14(7), 1799; https://doi.org/10.3390/ma14071799 - 5 Apr 2021
Cited by 176 | Viewed by 18904
Abstract
The recent introduction of three-dimensional (3D) printing is revolutionizing dentistry and is even being applied to orthodontic treatment of malocclusion. Clear, personalized, removable aligners are a suitable alternative to conventional orthodontic appliances, offering a more comfortable and efficient solution for patients. Including improved [...] Read more.
The recent introduction of three-dimensional (3D) printing is revolutionizing dentistry and is even being applied to orthodontic treatment of malocclusion. Clear, personalized, removable aligners are a suitable alternative to conventional orthodontic appliances, offering a more comfortable and efficient solution for patients. Including improved oral hygiene and aesthetics during treatment. Contemporarily, clear aligners are produced by a thermoforming process using various types of thermoplastic materials. The thermoforming procedure alters the properties of the material, and the intraoral environment further modifies the properties of a clear aligner, affecting overall performance of the material. Direct 3D printing offers the creation of highly precise clear aligners with soft edges, digitally designed and identically reproduced for an entire set of treatment aligners; offering a better fit, higher efficacy, and reproducibility. Despite the known benefits of 3D printing and the popularity of its dental applications, very limited technical and clinical data are available in the literature about directly printed clear aligners. The present article discusses the advantages of 3D printed aligners in comparison to thermoformed ones, describes the current state of the art, including a discussion of the possible road blocks that exist such as a current lack of approved and marketed materials and limited existence of aligner specific software. The present review suggests the suitability of 3D direct printed aligners is superior to that of thermoformed manufactured aligners because of the prior’s increased accuracy, load resistance, and lower deformation. It is an overall more stable way to produce an aligner where submillimeter movements can make a difference in treatment outcome. Direct 3D printing represents a complex method to control the thickness of the aligner and therefore has a better ability to control the force vectors that are used to produce tooth movement. There is currently no other approved material on the market that can do this. The conclusion of this article is that we encourage further in vitro and in vivo studies to test these new technologies and materials. Full article
(This article belongs to the Special Issue Current and Future Trends in Orthodontic Materials)
Show Figures

Figure 1

16 pages, 6313 KiB  
Article
Surface Quality Evaluation of Removable Thermoplastic Dental Appliances Related to Staining Beverages and Cleaning Agents
by Liliana Porojan, Roxana-Diana Vasiliu, Sorin-Daniel Porojan and Mihaela-Ionela Bîrdeanu
Polymers 2020, 12(8), 1736; https://doi.org/10.3390/polym12081736 - 3 Aug 2020
Cited by 37 | Viewed by 4427
Abstract
(1) Background: Thermoplastic materials are not inert and subject to changes in the oral environment, which affect their surface quality. Color stability and topographic characteristics of clear thermoplastic appliances are critical considerations. The study aimed to evaluate the optical changes and surface topography [...] Read more.
(1) Background: Thermoplastic materials are not inert and subject to changes in the oral environment, which affect their surface quality. Color stability and topographic characteristics of clear thermoplastic appliances are critical considerations. The study aimed to evaluate the optical changes and surface topography of different thermoplastic materials related to staining beverages and cleaning agents. (2) Methods: Thermoplastic polyethylene terephthalate glycol (PET-G) material specimens were selected for the study: S (Duran, Scheu-Dental GmbH, Iserlohn, Germany), D (Biolon, Dreve Dentamid GmbH, Unna, Germany), and B (Crystal, Bio Art Dental Equipment, Sao Carlos, Brazil). Four different media were involved for immersion: coffee (C) and black tea (T) at 55 °C, Coca-Cola (K) at 5 °C, and distilled water (W) at 22 °C. As for cleaning, chemical options and mechanical brushing were selected (P-powder, T-tablets, and X-brushing). Color changes, and mean surface roughness were measured at 24 h, 48 h, and after 7 days. Statistical analysis was performed. After the testing period, atomic force microscopy (AFM) analyses and SEM images were registered in order to characterize the surface topography. (3) Results: Quantitative color change evaluations revealed a slight change in color after 24 h and an extremely marked change after 48 h, respective 7 days. Mean roughness values are kept below the clinically acceptable limit of 0.20 µm for all samples. Related to mean nanoroughness values Sa, and 3D evaluations of the surface quality, Biolon samples have demonstrated the most constant behavior, while Crystal samples are visibly influenced by water immersion. Related to the cleaning method, the topography of Duran samples was influenced by mechanical brushing. (4) Conclusions: Nanoscale investigations provided high accuracy and more realistic surface quality examinations of the examined samples compared to profilometry. Both SEM and AFM should be used for a more detailed description of the surface topography. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Figure 1

Back to TopTop