10 pages, 727 KiB  
Article
Comparison of the Incidence of Nd:YAG Laser Capsulotomy Based on the Type of Intraocular Lens
by Yuri Lee, Jae Suk Kim, Bum Gi Kim, Je Hyung Hwang, Min Ji Kang and Jee Hye Lee
Medicina 2023, 59(12), 2173; https://doi.org/10.3390/medicina59122173 - 14 Dec 2023
Cited by 5 | Viewed by 2978
Abstract
Background and Objectives: Posterior capsular opacification (PCO) is the most common long-term complication of successful cataract surgery and can cause visual impairment. We aimed to investigate the effects of intraocular lens (IOL) characteristics on PCO by comparing the incidence of neodymium-doped yttrium [...] Read more.
Background and Objectives: Posterior capsular opacification (PCO) is the most common long-term complication of successful cataract surgery and can cause visual impairment. We aimed to investigate the effects of intraocular lens (IOL) characteristics on PCO by comparing the incidence of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy for different types of intraocular lenses. Materials and Methods: A retrospective analysis was performed on 2866 eyes that underwent cataract surgery between January 2010 and December 2017, with at least 5 years of follow-up. The IOLs used for surgery were the hydrophobic lenses SN60WF (Alcon, Fort Worth, TX, USA), ZCB00 (Johnson & Johnson Vision, Santa Ana, CA, USA), and MX60 (Bausch & Lomb, Rochester, NY, USA), and the hydrophilic lens MI60 (Bausch & Lomb, Rochester, NY, USA). We analyzed the incidence of Nd:YAG laser capsulotomy according to the type of IOL used. Results: The incidence of Nd:YAG laser capsulotomy was significantly higher with MI60 lenses (31.70%, 175/552 eyes) compared to SN60WF (7.90%, 113/1431 eyes), ZCB00 (10.06%, 64/636 eyes), and MX60 (10.57%, 13/123 eyes; p < 0.001) lenses. The incidence of Nd:YAG laser capsulotomy was significantly lower with the hydrophobic IOLs (8.68%, 190/2190 eyes) than with the hydrophilic IOL (31.70%, 175/552 eyes; p < 0.001). Over time, the rate of increase in the cumulative number of Nd:YAG laser capsulotomy cases was the highest with MI60. The cumulative rate of Nd:YAG laser capsulotomy during the first 3 years was 4.90% with SN60WF (70/1431 eyes), 6.76% with ZCB00 (43/636 eyes), 8.94% with MX60 (11/123 eyes), and 26.10% with MI60 (144/552 eyes) lenses. Conclusions: The incidence of PCO is influenced by the material of the IOLs. The hydrophilic IOL was associated with a higher rate of Nd:YAG laser capsulotomy than the hydrophobic IOLs, with a shorter time to Nd:YAG laser capsulotomy. Full article
(This article belongs to the Collection Advances in Cornea, Cataract, and Refractive Surgery)
Show Figures

Figure 1

9 pages, 1244 KiB  
Article
Factors Associated with Reclosure of Posterior Capsule Aperture by Flat Opacifications with Pearls after Nd:YAG Laser Posterior Capsulotomy
by Akiko Ota, Ichiro Ota, Shu Kachi, Goichiro Miyake, Fuminori Haga, Kensaku Miyake, Mineo Kondo and Kumiko Kato
Diseases 2023, 11(2), 82; https://doi.org/10.3390/diseases11020082 - 3 Jun 2023
Cited by 2 | Viewed by 2789
Abstract
In this retrospective case series, we investigated factors associated with posterior capsule aperture (PCA) reclosure following neodymium-yttrium aluminum garnet (Nd:YAG) laser posterior capsulotomy. The study encompassed patients who underwent cataract surgery with intraocular lens (IOL) implantation or a combined vitrectomy, cataract surgery, and [...] Read more.
In this retrospective case series, we investigated factors associated with posterior capsule aperture (PCA) reclosure following neodymium-yttrium aluminum garnet (Nd:YAG) laser posterior capsulotomy. The study encompassed patients who underwent cataract surgery with intraocular lens (IOL) implantation or a combined vitrectomy, cataract surgery, and IOL implantation between 2009 and 2022. PCA reclosure was observed in 22 eyes of 17 patients: 45% (10 eyes) underwent the triple procedure, and 55% (12 eyes) received cataract surgery with IOL implantation. In our clinic, 14% of patients were given IOLs with a 4% water content, while 73% (13 eyes) of those experiencing PCA reclosure had IOLs with a 4% water content. The mean interval between Nd:YAG capsulotomies was notably shorter than that between the initial cataract surgery and the first Nd:YAG laser capsulotomy. We also identified five stages of PCA reclosure progression. In conclusion, IOL water content may be linked to PCA reclosure, and the time to recurrence is shorter with each successive reclosure. Further research is needed to verify these findings and uncover additional contributing factors. Full article
Show Figures

Figure 1

11 pages, 2027 KiB  
Article
Effect of Combined Surgery in Patients with Complex Nanophthalmos
by Yantao Wei, Yihua Su, Lei Fang, Xinxing Guo, Stephanie Chen, Ying Han, Yingting Zhu, Bing Cheng, Shufen Lin, Yimin Zhong and Xing Liu
J. Clin. Med. 2022, 11(19), 5909; https://doi.org/10.3390/jcm11195909 - 7 Oct 2022
Cited by 4 | Viewed by 2361
Abstract
(1) Background: To evaluate the efficacy and safety of combined surgery (limited pars plana vitrectomy, anterior-chamber stabilized phacoemulsification, IOL implantation and posterior capsulotomy, LPPV + ACSP + IOL + PC) in complex nanophthalmos. (2) Methods: Patients with complex nanophthalmos were recruited to undergo [...] Read more.
(1) Background: To evaluate the efficacy and safety of combined surgery (limited pars plana vitrectomy, anterior-chamber stabilized phacoemulsification, IOL implantation and posterior capsulotomy, LPPV + ACSP + IOL + PC) in complex nanophthalmos. (2) Methods: Patients with complex nanophthalmos were recruited to undergo LPPV + ACSP + IOL + PC from January 2017 to February 2021. Preoperative and post-operative intraocular pressure (IOP), best corrected visual acuity (BCVA), anterior chamber depth (ACD), and number of glaucoma medications were compared using the paired t-test or Wilcoxon signed rank sum tests. Surgical success rate was evaluated. Surgery-associated complications were documented. (3) Results: Forty-five eyes of 37 patients with complex nanophthalmos were enrolled. The mean follow-up period was 21.7 ± 10.6 months after surgery. Mean IOP decreased from 32.7 ± 8.7 mmHg before surgery to 16.9 ± 4.5 mmHg (p < 0.001) at the final follow-up visit, mean logMAR BCVA improved from 1.28 ± 0.64 to 0.96 ± 0.44 (p < 0.001), mean ACD significantly increased from 1.14 ± 0.51 mm to 3.07 ± 0.66 mm (p < 0.001), and the median number of glaucoma medications dropped from 3 (1, 4) to 2 (0, 4) (p < 0.001). The success rate was 88.9% (40 eyes) at the final follow-up visit. Two eyes had localized choroidal detachments which resolved with medical treatment. (4) Conclusions: LPPV + ACSP + IOL + PC is a safe and effective surgical procedure, which can decrease IOP, improve BCVA, deepen the anterior chamber, and reduce the number of glaucoma medications in patients with complex nanophthalmos. It can be considered as one of the first treatment in nanophthalmic eyes with complex conditions. Full article
(This article belongs to the Special Issue Advances in Glaucoma Surgery)
Show Figures

Figure 1

22 pages, 4089 KiB  
Review
Research Progress Concerning a Novel Intraocular Lens for the Prevention of Posterior Capsular Opacification
by Yidong Zhang, Chengshou Zhang, Silong Chen, Jianghua Hu, Lifang Shen and Yibo Yu
Pharmaceutics 2022, 14(7), 1343; https://doi.org/10.3390/pharmaceutics14071343 - 25 Jun 2022
Cited by 21 | Viewed by 6706
Abstract
Posterior capsular opacification (PCO) is the most common complication resulting from cataract surgery and limits the long-term postoperative visual outcome. Using Nd:YAG laser-assisted posterior capsulotomy for the clinical treatment of symptomatic PCO increases the risks of complications, such as glaucoma, retinal diseases, uveitis, [...] Read more.
Posterior capsular opacification (PCO) is the most common complication resulting from cataract surgery and limits the long-term postoperative visual outcome. Using Nd:YAG laser-assisted posterior capsulotomy for the clinical treatment of symptomatic PCO increases the risks of complications, such as glaucoma, retinal diseases, uveitis, and intraocular lens (IOL) pitting. Therefore, finding how to prevent PCO development is the subject of active investigations. As a replacement organ, the IOL is implanted into the lens capsule after cataract surgery, but it is also associated with the occurrence of PCO. Using IOL as a medium for PCO prophylaxis is a more facile and efficient method that has demonstrated various clinical application prospects. Thus, scientists have conducted a lot of research on new intraocular lens fabrication methods, such as optimizing IOL materials and design, and IOL surface modification (including plasma/ultraviolet/ozone treatment, chemical grafting, drug loading, coating modification, and layer-by-layer self-assembly methods). This paper summarizes the research progress for different types of intraocular lenses prepared by different surface modifications, including anti-biofouling IOLs, enhanced-adhesion IOLs, micro-patterned IOLs, photothermal IOLs, photodynamic IOLs, and drug-loading IOLs. These modified intraocular lenses inhibit PCO development by reducing the residual intraoperative lens epithelial cells or by regulating the cellular behavior of lens epithelial cells. In the future, more works are needed to improve the biosecurity and therapeutic efficacy of these modified IOLs. Full article
(This article belongs to the Special Issue Ophthalmic Drug Delivery, 2nd Edition)
Show Figures

Figure 1

19 pages, 10162 KiB  
Article
Aged Lens Epithelial Cells Suppress Proliferation and Epithelial–Mesenchymal Transition-Relevance for Posterior Capsule Opacification
by Zongbo Wei, Pasley Gordon, Caili Hao, Jingru Huangfu, Emily Fan, Xiang Zhang, Hong Yan and Xingjun Fan
Cells 2022, 11(13), 2001; https://doi.org/10.3390/cells11132001 - 22 Jun 2022
Cited by 17 | Viewed by 3582
Abstract
Posterior capsule opacification (PCO) is a frequent complication after cataract surgery, and advanced PCO requires YAG laser (Nd: YAG) capsulotomy, which often gives rise to more complications. Lens epithelial cell (LEC) proliferation and transformation (i.e., epithelial–mesenchymal transition (EMT)) are two critical elements in [...] Read more.
Posterior capsule opacification (PCO) is a frequent complication after cataract surgery, and advanced PCO requires YAG laser (Nd: YAG) capsulotomy, which often gives rise to more complications. Lens epithelial cell (LEC) proliferation and transformation (i.e., epithelial–mesenchymal transition (EMT)) are two critical elements in PCO initiation and progression pathogenesis. While PCO marginally impacts aged cataract surgery patients, PCO incidences are exceptionally high in infants and children undergoing cataract surgery. The gene expression of lens epithelial cell aging and its role in the discrepancy of PCO prevalence between young and older people have not been fully studied. Here, we conducted a comprehensive differentially expressed gene (DEG) analysis of a cell aging model by comparing the early and late passage FHL124 lens epithelial cells (LECs). In vitro, TGFβ2, cell treatment, and in vivo mouse cataract surgical models were used to validate our findings. We found that aged LECs decelerated rates of cell proliferation accompanied by dysregulation of cellular immune response and cell stress response. Surprisingly, we found that LECs systematically downregulated epithelial–mesenchymal transition (EMT)-promoting genes. The protein expression of several EMT hallmark genes, e.g., fibronectin, αSMA, and cadherin 11, were gradually decreased during LECs aging. We then confirmed these findings in vitro and found that aged LECs markedly alleviated TGFβ2-mediated EMT. Importantly, we explicitly confirmed the in vitro findings from the in vivo mouse cataract surgery studies. We propose that both the high proliferation rate and EMT-enriched young LECs phenotypic characteristics contribute to unusually high PCO incidence in infants and children. Full article
(This article belongs to the Special Issue New Advances in Lens Biology and Pathology)
Show Figures

Graphical abstract

9 pages, 251 KiB  
Article
Refractive Changes Following Premature Posterior Capsulotomy Using Neodymium:Yttrium–Aluminum–Garnet Laser
by Chia-Yi Lee, Tsai-Te Lu, Yaa-Jyuhn James Meir, Kuan-Jen Chen, Chun-Fu Liu, Chao-Min Cheng and Hung-Chi Chen
J. Pers. Med. 2022, 12(2), 272; https://doi.org/10.3390/jpm12020272 - 13 Feb 2022
Cited by 9 | Viewed by 2764
Abstract
We aimed to determine the timing of neodymium:yttrium–aluminum–garnet (Nd:YAG) laser capsulotomy on corrected-distance visual acuity (CDVA), intraocular pressure (IOP), and spherical equivalent (SE) in patients with posterior capsular opacification (PCO). There were 59 patients with unilateral PCO and a history of Nd:YAG laser [...] Read more.
We aimed to determine the timing of neodymium:yttrium–aluminum–garnet (Nd:YAG) laser capsulotomy on corrected-distance visual acuity (CDVA), intraocular pressure (IOP), and spherical equivalent (SE) in patients with posterior capsular opacification (PCO). There were 59 patients with unilateral PCO and a history of Nd:YAG laser capsulotomy enrolled and further divided into the early Nd:YAG group (timing < 12 months, n = 25) and late Nd:YAG group (timing > 12 months, n = 34) depending on the elapsed months from phacoemulsification to Nd:YAG laser capsulotomy. The primary outcomes were CDVA, IOP, and SE before (immediately before Nd:YAG laser capsulotomy) and after (weeks one and four after the laser treatment). The independent t test was applied to analyze the difference in CDVA, IOP, and SE between the two groups, while the generalized estimating equation with Bonferroni adjustment was conducted to evaluate the effect of all the parameters on the change in SE with adjusted odds ratio (aOR) and 95% confidence interval (CI). The CDVA showed significant improvement in both the early Nd:YAG group (p = 0.005) and the late Nd:YAG group (p = 0.001), and hyperopic change occurred in both the early Nd:YAG group (p = 0.003) and the late Nd:YAG group (p = 0.017). The early Nd:YAG group revealed more significant hyperopic change compared with the late Nd:YAG group four weeks after Nd:YAG treatment (p < 0.001), which was still significant after multivariable analysis (aOR: 0.899, 95% CI: 0.868–0.930, p = 0.011). In addition, a deeper ACD (aOR: 0.764, 95% CI: 0.671–0.869, p = 0.019) was significantly correlated with hyperopic change. In conclusion, Nd:YAG laser capsulotomy performed within one year after cataract surgery may lead to significant hyperopic change, in which the ACD alteration affects the hyperopic shift significantly. Full article
(This article belongs to the Section Clinical Medicine, Cell, and Organism Physiology)
8 pages, 1055 KiB  
Article
Prediction Error Stabilization and Long-Term Standard Results with a Monofocal Intraocular Lens
by Beatríz Macías-Murelaga, Gonzaga Garay-Aramburu, Roberto Bergado-Mijangos, Daniel Coello-Ojeda, Itziar Ozaeta, Pio Jésus Garcia-Gómez, Jesús Garrido-Fierro, Manuel Rodríguez-Vallejo and Joaquín Fernández
Vision 2022, 6(1), 5; https://doi.org/10.3390/vision6010005 - 13 Jan 2022
Cited by 4 | Viewed by 2718
Abstract
The aim of this study was to assess the stability and differences between objective (O-Rx) and subjective (S-Rx) refraction for the assessment of the prediction error (PE). A secondary aim was to report the results of a monofocal intraocular lens (IOL). 100 subjects [...] Read more.
The aim of this study was to assess the stability and differences between objective (O-Rx) and subjective (S-Rx) refraction for the assessment of the prediction error (PE). A secondary aim was to report the results of a monofocal intraocular lens (IOL). 100 subjects were included for whom S-Rx and O-Rx were obtained for all visits, and for visual performance, posterior capsular opacification incidence and Nd:YAG rates at 12 months. Either S-Rx and O-Rx showed a hyperopic shift from 1 to 6 months (p < 0.05) and stabilization after 6 months. S-Rx was related with the axial length (rho = −0.29, p = 0.007), obtaining a major tendency towards hyperopia in short eyes implanted with high-power IOLs. O-Rx showed a myopic shift in comparison to S-Rx (p < 0.05). This resulted in a decrease of the number of eyes in ±0.50 D and ±1.00 D from 79 to 67% and from 94 to 90%, respectively. The median (interquartile range) uncorrected and corrected visual acuities were 0.1 (0.29) and 0 (0.12) logMAR, respectively, and seven eyes required Nd:YAG capsulotomy at 12 months. Some caution should be taken in PE studies in which O-Rx is used or S-Rx is measured in a 1-month follow-up. Constant optimization should be conducted for this IOL after S-Rx stabilization. Full article
Show Figures

Figure 1

10 pages, 418 KiB  
Article
Corneal Endothelial Changes Following Early Capsulotomy Using Neodymium:Yttrium–Aluminum–Garnet Laser
by Hung-Chi Chen, Chia-Yi Lee, Chun-Fu Liu, Yi-Jen Hsueh, Yaa-Jyuhn James Meir, Chao-Min Cheng and Wei-Chi Wu
Diagnostics 2022, 12(1), 150; https://doi.org/10.3390/diagnostics12010150 - 8 Jan 2022
Cited by 9 | Viewed by 2307
Abstract
We aimed to survey whether the timing of neodymium:yttrium–aluminum–garnet (Nd:YAG) laser capsulotomy would alter the corneal endothelial morphology and density. A retrospective cohort study was conducted, and 48 patients with unilateral posterior capsular opacity (PCO) and Nd:YAG laser capsulotomy performance were enrolled. The [...] Read more.
We aimed to survey whether the timing of neodymium:yttrium–aluminum–garnet (Nd:YAG) laser capsulotomy would alter the corneal endothelial morphology and density. A retrospective cohort study was conducted, and 48 patients with unilateral posterior capsular opacity (PCO) and Nd:YAG laser capsulotomy performance were enrolled. The participants were divided into the early Nd:YAG group (timing ≤ 12 months, n = 20) and late Nd:YAG group (timing > 12 months, n= 28) depending on elapsed months between phacoemulsification and Nd:YAG laser capsulotomy. Endothelial cell density (ECD), coefficient of variant (CV), hexagonality (HEX), and central corneal thickness (CCT) between the two groups were collected. A generalized estimate equation was conducted to evaluate the corneal endothelial parameters between the two groups with an adjusted odds ratio (aOR) and 95% confidence interval (CI). The CDVA was improved after treatment in both groups (both p < 0.001). Chronically, ECD in the early group was significantly decreased one week after treatment (2221.50 ± 327.73/mm2 vs. 2441.55 ± 321.80/mm2, p < 0.001), which recovered to 2369.95 ± 76.37/mm2 four weeks after the treatment but was still lower than the preoperative status (p < 0.001). In addition, the HEX percentage showed a significant reduction at four weeks after treatment (p = 0.028). The ECD in the early group was significantly lower than that in the late group (aOR: 0.167, 95% CI: 0.079–0.356, p = 0.003) in both week 1 (p < 0.001) and week 4 (p = 0.004) after laser treatment. In conclusion, the early application of Nd:YAG laser capsulotomy within one year after cataract surgery may be the reason for postoperative ECD decrement without known etiology. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

7 pages, 388 KiB  
Article
Intraocular Lens Power, Myopia, and the Risk of Nd:YAG Capsulotomy after 15,375 Cataract Surgeries
by Juha-Matti Lindholm, Ilkka Laine and Raimo Tuuminen
J. Clin. Med. 2020, 9(10), 3071; https://doi.org/10.3390/jcm9103071 - 24 Sep 2020
Cited by 13 | Viewed by 3219
Abstract
The present study estimated the 5-year cumulative probability of Nd:YAG laser posterior capsulotomy according to the diopter power of implanted hydrophobic acrylic intraocular lenses (IOLs). Data were retrospectively collected of 15,375 eyes having cataract surgery and in-the-bag implantation of hydrophobic acrylic monofocal IOLs [...] Read more.
The present study estimated the 5-year cumulative probability of Nd:YAG laser posterior capsulotomy according to the diopter power of implanted hydrophobic acrylic intraocular lenses (IOLs). Data were retrospectively collected of 15,375 eyes having cataract surgery and in-the-bag implantation of hydrophobic acrylic monofocal IOLs at the Ophthalmology Unit of Kymenlaakso Central Hospital, Kotka, Finland between the years 2007 and 2016. The cumulative probability of Nd:YAG capsulotomy was calculated by Kaplan–Meier estimates, and potential risk factors were analyzed using the Cox proportional hazards model. The 5-year cumulative probability of Nd:YAG capsulotomy after cataract surgery was 27.4% (95% confidence interval (CI) 22.9–32.6%) for low-diopter (5–16.5 D) IOLs, 14.6% (13.8–15.5%) for mid-diopter (17–24.5 D) IOLs, and 13.6% (11.7–15.6%) for high-diopter (25–30 D) IOLs. A multivariate Cox regression analysis showed that low-diopter IOLs (HR 1.76; 95% CI 1.38–2.25; p < 0.001) were associated with an increased risk of Nd:YAG capsulotomy compared to mid-diopter IOLs over the follow-up period after accounting for other predictors. Real-world evidence shows that low-diopter IOLs are associated with significantly higher risk of Nd:YAG capsulotomy within five years following implantation. Estimation should help in evaluating the risks of cataract surgery in myopic eyes. Full article
(This article belongs to the Special Issue Cataract Surgery and Postoperative Care)
Show Figures

Figure 1

5 pages, 184 KiB  
Article
New Insights Into Pathophysiological Mechanisms Regulating Conventional Aqueous Humor Outflow
by Daiva Paulavičiūtė-Baikštienė, Rūta Baršauskaitė and Ingrida Janulevičienė
Medicina 2013, 49(4), 26; https://doi.org/10.3390/medicina49040026 - 5 May 2013
Cited by 4 | Viewed by 1339
Abstract
The aim of the article was to overview the pathophysiology of the conventional outflow pathway, trabecular meshwork, and intraocular pressure and to discuss the options of future glaucoma treatment directed to improvement in aqueous outflow. The literature search in the Medline, Embase, and [...] Read more.
The aim of the article was to overview the pathophysiology of the conventional outflow pathway, trabecular meshwork, and intraocular pressure and to discuss the options of future glaucoma treatment directed to improvement in aqueous outflow. The literature search in the Medline, Embase, and Cochrane databases from April to May 2012 was performed; a total of 47 articles analyzed. The diminished conventional pathway may be altered by several pathophysiological mechanisms like TM obstruction caused by transforming growth factor-β2, clastic nondeformable cells, macrophages leaking from hypermature cataract, iris pigment, lens capsular fragments after YAG-laser posterior capsulotomy, proteins and their subfragments. It is known that trabecular meshwork contraction reduces outflow, and the actomyosin system is directly linked to this mechanism. New glaucoma drugs are still under investigation, but it is already proven that agents such as latranculin-B are effective in improving aqueous drainage. Selective Rho-associated coiled coilforming protein kinase inhibitors have been shown to cause a significant improvement in outflow facility and may become a new option for glaucoma treatment. Caldesmon negatively regulates actin-myosin interactions and thus increases outflow. Stem cells may replace missing or nonfunctional trabecular meshwork cells and hopefully will bring a new treatment solution. Pathophysiological mechanisms regulating conventional aqueous humor outflow are still not fully understood and require further investigations. Future treatment decisions should be directed to a specific mechanism regulating an elevation in intraocular pressure. Full article
5 pages, 134 KiB  
Article
Prevention of Posterior Capsule Opacification With 3 Intraocular Lens Models: a Prospective, Randomized, Long-Term Clinical Trial
by Reda Žemaitienė and Vytautas Jašinskas
Medicina 2011, 47(11), 85; https://doi.org/10.3390/medicina47110085 - 5 Dec 2011
Cited by 9 | Viewed by 1223
Abstract
The aim of this prospective randomized study was to evaluate the impact of different sharp-edged intraocular lenses (IOLs) (hydrophobic acrylic or silicone) on posterior and anterior lens capsule opacification (PCO and ACO) at 3-year postoperative follow-up.
Material and Methods
. A total of [...] Read more.
The aim of this prospective randomized study was to evaluate the impact of different sharp-edged intraocular lenses (IOLs) (hydrophobic acrylic or silicone) on posterior and anterior lens capsule opacification (PCO and ACO) at 3-year postoperative follow-up.
Material and Methods
. A total of 96 eyes (89 patients) having a standard uncomplicated phacoemulsification procedure for age-related cataract were included in a prospective clinical study: 34 eyes with a 3-piece acrylic hydrophobic (AcrySof, MA3OBA), 32 eyes with a 1-piece acrylic hydrophobic (AcrySof, SA3OAL), and 30 eyes with a 3-piece silicone (CeeOn 911A) IOL. Visual acuity, capsulorrhexis/optic overlapping, ACO and PCO (using EPCO2000 system) were evaluated at 3-year follow-up. Capsulotomies performed by means of neodymium-yttrium-aluminum-garnet (Nd:YAG) laser were recorded.
Results.
Three years after surgery, the grade of ACO of the capsulorrhexis rim area and the capsule/optic area was significantly greater in the silicone IOL group than in the acrylic IOL groups (P<0.05). During 3 postoperative years, there were no significant differences in the PCO values either in the entire IOL optic area or in the central 3-mm optic zone comparing the groups. Three years after surgery, 9% of eyes with a 3-piece acrylic IOL, 3.1% of eyes with a 1-piece acrylic IOL, and no case in the silicone IOL group had Nd:YAG capsulotomy (P>0.05).
Conclusion
. The 3-year follow-up after cataract surgery showed no difference in PCO development (EPCO2000) between acrylic hydrophobic and silicone sharp-edged IOLs. However, the need for Nd:YAG laser capsulotomy was higher in the acrylic IOL groups than the silicone IOL group, though the difference was not significant. ACO was greatest in the eyes with 3-piece silicone IOLs Full article