Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (8)

Search Parameters:
Keywords = peritendinous adhesions

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 3077 KiB  
Article
Impact of High-Molecular-Weight Hyaluronic Acid on Gene Expression in Rabbit Achilles Tenocytes In Vitro
by Iris Miescher, Petra Wolint, Christine Opelz, Jess G. Snedeker, Pietro Giovanoli, Maurizio Calcagni and Johanna Buschmann
Int. J. Mol. Sci. 2022, 23(14), 7926; https://doi.org/10.3390/ijms23147926 - 18 Jul 2022
Cited by 7 | Viewed by 2963
Abstract
(1) Background: Surgical tendon repair often leads to adhesion formation, leading to joint stiffness and a reduced range of motion. Tubular implants set around sutured tendons might help to reduce peritendinous adhesions. The lubricant hyaluronic acid (HA) is a viable option for optimizing [...] Read more.
(1) Background: Surgical tendon repair often leads to adhesion formation, leading to joint stiffness and a reduced range of motion. Tubular implants set around sutured tendons might help to reduce peritendinous adhesions. The lubricant hyaluronic acid (HA) is a viable option for optimizing such tubes with the goal of further enhancing the anti-adhesive effect. As the implant degrades over time and diffusion is presumed, the impact of HA on tendon cells is important to know. (2) Methods: A culture medium of rabbit Achilles tenocytes was supplemented with high-molecular-weight (HMW) HA and the growth curves of the cells were assessed. Additionally, after 3, 7 and 14 days, the gene expression of several markers was analyzed for matrix assembly, tendon differentiation, fibrosis, proliferation, matrix remodeling, pro-inflammation and resolution. (3) Results: The addition of HA decreased matrix marker genes, downregulated the fibrosis marker α-SMA for a short time and slightly increased the matrix-remodeling gene MMP-2. Of the pro-inflammatory marker genes, only IL-6 was significantly upregulated. IL-6 has to be kept in check, although IL-6 is also needed for a proper initial inflammation and efficient resolution. (4) Conclusions: The observed effects in vitro support the intended anti-adhesion effect and therefore, the use of HMW HA is promising as a biodegradable implant for tendon repair. Full article
Show Figures

Figure 1

12 pages, 9666 KiB  
Article
A Simplified Murine Model to Imitate Flexor Tendon Adhesion Formation without Suture
by Rong Bao, Shi Cheng, Jianyu Zhu, Feng Hai, Wenli Mi and Shen Liu
Biomimetics 2022, 7(3), 92; https://doi.org/10.3390/biomimetics7030092 - 7 Jul 2022
Cited by 1 | Viewed by 2974
Abstract
Peritendinous adhesion (PA) around tendons are daunting challenges for hand surgeons. Tenotomy with various sutures are considered classical tendon repair models (TRM) of tendon adhesion as well as tendon healing. However, potential biomimetic therapies such as anti-adhesion barriers and artificial tendon sheaths to [...] Read more.
Peritendinous adhesion (PA) around tendons are daunting challenges for hand surgeons. Tenotomy with various sutures are considered classical tendon repair models (TRM) of tendon adhesion as well as tendon healing. However, potential biomimetic therapies such as anti-adhesion barriers and artificial tendon sheaths to avoid recurrence of PA are sometimes tested in these models without considering tendon healing. Thus, our aim is to create a simplified model without sutures in this study by using three 6 mm longitudinal and parallel incisions called the longitudinal incision model (LCM) in the murine flexor tendon. We found that the adhesion score of LCM has no significant difference to that in TRM. The range of motion (ROM) reveals similar adhesion formation in both TRM and LCM groups. Moreover, mRNA expression levels of collagen I and III in LCM shows no significant difference to that in TRM. The breaking force and stiffness of LCM were significantly higher than that of TRM. Therefore, LCM can imitate flexor tendon adhesion formation without sutures compared to TRM, without significant side effects on biomechanics with an easy operation. Full article
(This article belongs to the Special Issue Biomimetic Platform for Tissue Regeneration)
Show Figures

Figure 1

16 pages, 4254 KiB  
Article
Effectiveness of Hyaluronan Autocross-Linked-Based Gel in the Prevention of Peritendinous Adherence Following Tenolysis
by Andrea Marchesini, Francesco De Francesco, Pier Paolo Pangrazi, Letizia Senesi, Andrea Campodonico, Valentina Riccio, Stefano Geuna, Barbara Zavan and Michele Riccio
Appl. Sci. 2021, 11(16), 7613; https://doi.org/10.3390/app11167613 - 19 Aug 2021
Cited by 2 | Viewed by 2245
Abstract
Peritendinous adhesions are a frequent occurrence following tenolysis and present a major clinical challenge regarding prevention and management, with no recovery assured from conservative or surgical approaches. Herein, we investigated the effectiveness of Hyaloglide®, a hyaluronan gel-based product with a novel [...] Read more.
Peritendinous adhesions are a frequent occurrence following tenolysis and present a major clinical challenge regarding prevention and management, with no recovery assured from conservative or surgical approaches. Herein, we investigated the effectiveness of Hyaloglide®, a hyaluronan gel-based product with a novel autocross-linked technology, in a rabbit model affected by tenolysis on the flexor digitorum communis tendon (FDC). A 1.5-cm-long scrubbing of the tendon surface was performed bilaterally to induce peritendinous adhesion on FDC of 30 animals with subsequent application of Hyaloglide® on the surrounding injured area, in one randomly chosen tendon. The contralateral tendon was treated with saline solution as the control. We sacrificed the rabbit models after 45 days of surgery and quantitatively assessed the generation of peritendinous adherence and regeneration of the tendon sheaths using histological (hematossyline-eosine, masson’s trichromic), histomorphometrical (Tang score, Soslowsky Svesson, and Cook score), light electron microscopic, and gene expression investigations. Four rabbits were devoted to biomechanical analysis. Peritendinous adhesions were limited in Hyaloglide®-treated tendons; moreover, well-regenerated tendon sheaths were observed conversely to untreated tendons presenting with extensive areas of adhesions on the tendon surface. Histomorphometrical analysis revealed an adhesion score (Tang score) significantly better in the treated group (p = 0.001 *) compared to the control group. Moreover, the Soslowsky, Svensson, and Cook score parameters revealed a significantly improved regeneration for fiber structure, cellularity, and vascularity in the treated group (p = 0.001 *). No differences were reported for cartilaginous formation (p = 0.08). Gene expression analysis showed a significant increase in collagen type I expression in the treated group compared to the control group, while metalloprotease 1 and 9 were significantly increased in the control group. Biomechanical analysis did not show significant differences in both groups. Hyaloglide® treatment was safe and well-tolerated, generating improved tissue status. Local application of Hyaloglide® prevents adhesion formation after tenolysis and promotes normal healing with regeneration of the synovial sheath in a rabbit model. Full article
Show Figures

Figure 1

20 pages, 6385 KiB  
Article
Functional Hyaluronic Acid-Polylactic Acid/Silver Nanoparticles Core-Sheath Nanofiber Membranes for Prevention of Post-Operative Tendon Adhesion
by Chih-Hao Chen, Yuan-Hsun Cheng, Shih-Heng Chen, Andy Deng-Chi Chuang and Jyh-Ping Chen
Int. J. Mol. Sci. 2021, 22(16), 8781; https://doi.org/10.3390/ijms22168781 - 16 Aug 2021
Cited by 25 | Viewed by 4294
Abstract
In this study, we prepared core-sheath nanofiber membranes (CSNFMs) with silver nanoparticles (Ag NPs) embedding in the polylactic acid (PLA) nanofiber sheath and hyaluronic acid (HA) in the nanofiber core. The PLA/Ag NPs sheath provides mechanical support as well as anti-bacterial and anti-inflammatory [...] Read more.
In this study, we prepared core-sheath nanofiber membranes (CSNFMs) with silver nanoparticles (Ag NPs) embedding in the polylactic acid (PLA) nanofiber sheath and hyaluronic acid (HA) in the nanofiber core. The PLA/Ag NPs sheath provides mechanical support as well as anti-bacterial and anti-inflammatory properties. The controlled release of HA from the core could exert anti-adhesion effects to promote tendon sliding while reducing fibroblast attachment. From the microfibrous structural nature of CSNFMs, they function as barrier membranes to reduce fibroblast penetration without hampering nutrient transports to prevent post-operative peritendinous adhesion. As the anti-adhesion efficacy will depend on release rate of HA from the core as well as Ag NP from the sheath, we fabricated CSNFMs of comparable fiber diameter, but with thick (Tk) or thin (Tn) sheath. Similar CSNFMs with thick (Tk+) and thin (Tn+) sheath but with embedded Ag NPs in the sheath were also prepared. The physico-chemical properties of the barrier membranes were characterized in details, together with their biological response including cell penetration, cell attachment and proliferation, and cytotoxicity. Peritendinous anti-adhesion models in rabbits were used to test the efficacy of CSNFMs as anti-adhesion barriers, from gross observation, histology, and biomechanical tests. Overall, the CSNFM with thin-sheath and Ag NPs (Tn+) shows antibacterial activity with low cytotoxicity, prevents fibroblast penetration, and exerts the highest efficacy in reducing fibroblast attachment in vitro. From in vivo studies, the Tn+ membrane also shows significant improvement in preventing peritendinous adhesions as well as anti-inflammatory efficacy, compared with Tk and Tn CSNFMs and a commercial adhesion barrier film (SurgiWrap®) made from PLA. Full article
(This article belongs to the Special Issue Nanomaterials for Tissue Engineering Applications 2.0)
Show Figures

Figure 1

19 pages, 4805 KiB  
Article
Ibuprofen-Loaded Hyaluronic Acid Nanofibrous Membranes for Prevention of Postoperative Tendon Adhesion through Reduction of Inflammation
by Chien-Tzung Chen, Chih-Hao Chen, Chialin Sheu and Jyh-Ping Chen
Int. J. Mol. Sci. 2019, 20(20), 5038; https://doi.org/10.3390/ijms20205038 - 11 Oct 2019
Cited by 48 | Viewed by 4802
Abstract
A desirable multi-functional nanofibrous membrane (NFM) for prevention of postoperative tendon adhesion should be endowed with abilities to prevent fibroblast attachment and penetration and exert anti-inflammation effects. To meet this need, hyaluronic acid (HA)/ibuprofen (IBU) (HAI) NFMs were prepared by electrospinning, followed by [...] Read more.
A desirable multi-functional nanofibrous membrane (NFM) for prevention of postoperative tendon adhesion should be endowed with abilities to prevent fibroblast attachment and penetration and exert anti-inflammation effects. To meet this need, hyaluronic acid (HA)/ibuprofen (IBU) (HAI) NFMs were prepared by electrospinning, followed by dual ionic crosslinking with FeCl3 (HAIF NFMs) and covalent crosslinking with 1,4-butanediol diglycidyl ether (BDDE) to produce HAIFB NFMs. It is expected that the multi-functional NFMs will act as a physical barrier to prevent fibroblast penetration, HA will reduce fibroblast attachment and impart a lubrication effect for tendon gliding, while IBU will function as an anti-inflammation drug. For this purpose, we successfully fabricated HAIFB NFMs containing 20% (HAI20FB), 30% (HAI30FB), and 40% (HAI40FB) IBU and characterized their physico-chemical properties by scanning electron microscopy, Fourier transformed infrared spectroscopy, thermal gravimetric analysis, and mechanical testing. In vitro cell culture studies revealed that all NFMs except HAI40FB possessed excellent effects in preventing fibroblast attachment and penetration while preserving high biocompatibility without influencing cell proliferation. Although showing significant improvement in mechanical properties over other NFMs, the HAI40FB NFM exhibited cytotoxicity towards fibroblasts due to the higher percentage and concentration of IBU released form the membrane. In vivo studies in a rabbit flexor tendon rupture model demonstrated the efficacy of IBU-loaded NFMs (HAI30FB) over Seprafilm® and NFMs without IBU (HAFB) in reducing local inflammation and preventing tendon adhesion based on gross observation, histological analyses, and biomechanical functional assays. We concluded that an HAI30FB NFM will act as a multi-functional barrier membrane to prevent peritendinous adhesion after tendon surgery. Full article
Show Figures

Figure 1

17 pages, 4317 KiB  
Article
Electrospun Water-Borne Polyurethane Nanofibrous Membrane as a Barrier for Preventing Postoperative Peritendinous Adhesion
by Shih-Heng Chen, Pang-Yun Chou, Zhi-Yu Chen and Feng-Huei Lin
Int. J. Mol. Sci. 2019, 20(7), 1625; https://doi.org/10.3390/ijms20071625 - 1 Apr 2019
Cited by 32 | Viewed by 4502
Abstract
Peritendinous adhesion is a major complication after tendon injury and the subsequent repairs or reconstructions. The degree of adhesion can be reduced by the interposition of a membranous barrier between the traumatized tendon and the surrounding tissue. In the present study, electrospun water-borne [...] Read more.
Peritendinous adhesion is a major complication after tendon injury and the subsequent repairs or reconstructions. The degree of adhesion can be reduced by the interposition of a membranous barrier between the traumatized tendon and the surrounding tissue. In the present study, electrospun water-borne polyurethane (WPU) nanofibrous membranes (NFMs) were created for use after the reparation or reconstruction of tendons to reduce adhesion. In the electrospinning process, water was employed as the solvent for WPU, and this solvent was ecofriendly and nontoxic. The nanofibrous architecture and pore size of the WPU NFMs were analyzed. Their microporosity (0.78–1.05 µm) blocked the penetration of fibroblasts, which could result in adhesion and scarring around the tendon during healing. The release of WPU mimicked the lubrication effect of the synovial fluid produced by the synovium around the tendon. In vitro cell studies revealed that the WPU NFMs effectively reduced the number of fibroblasts that became attached and that there was no significant cytotoxicity. In vivo studies with the rabbit flexor tendon repair model revealed that WPU NFMs reduced the degree of peritendinous adhesion, as determined using a gross examination; a histological cross section evaluation; and measurements of the range of motion of interphalangeal joints (97.1 ± 14.7 and 79.0 ± 12.4 degrees in proximal and distal interphalangeal joints respectively), of the length of tendon excursion (11.6 ± 1.9 cm), and of the biomechanical properties. Full article
(This article belongs to the Special Issue Bio- and Nano-Materials and Their Interfaces)
Show Figures

Figure 1

13 pages, 1800 KiB  
Article
Multi-Layer Electrospun Membrane Mimicking Tendon Sheath for Prevention of Tendon Adhesions
by Shichao Jiang, Hede Yan, Dapeng Fan, Jialin Song and Cunyi Fan
Int. J. Mol. Sci. 2015, 16(4), 6932-6944; https://doi.org/10.3390/ijms16046932 - 26 Mar 2015
Cited by 46 | Viewed by 7704
Abstract
Defect of the tendon sheath after tendon injury is a main reason for tendon adhesions, but it is a daunting challenge for the biomimetic substitute of the tendon sheath after injury due to its multi-layer membrane-like structure and complex biologic functions. In this [...] Read more.
Defect of the tendon sheath after tendon injury is a main reason for tendon adhesions, but it is a daunting challenge for the biomimetic substitute of the tendon sheath after injury due to its multi-layer membrane-like structure and complex biologic functions. In this study, a multi-layer membrane with celecoxib-loaded poly(l-lactic acid)-polyethylene glycol (PELA) electrospun fibrous membrane as the outer layer, hyaluronic acid (HA) gel as middle layer, and PELA electrospun fibrous membrane as the inner layer was designed. The anti-adhesion efficacy of this multi-layer membrane was compared with a single-layer use in rabbit flexor digitorum profundus tendon model. The surface morphology showed that both PELA fibers and celecoxib-loaded PELA fibers in multi-layer membrane were uniform in size, randomly arrayed, very porous, and smooth without beads. Multi-layer membrane group had fewer peritendinous adhesions and better gliding than the PELA membrane group and control group in gross and histological observation. The similar mechanical characteristic and collagen expression of tendon repair site in the three groups indicated that the multi-layer membrane did not impair tendon healing. Taken together, our results demonstrated that such a biomimetic multi-layer sheath could be used as a potential strategy in clinics for promoting tendon gliding and preventing adhesion without poor tendon healing. Full article
(This article belongs to the Special Issue Biomaterials for Tissue Engineering)
Show Figures

Figure 1

12 pages, 3606 KiB  
Article
Silver Nanoparticles/Ibuprofen-Loaded Poly(l-lactide) Fibrous Membrane: Anti-Infection and Anti-Adhesion Effects
by Shuai Chen, Guangda Wang, Tianyi Wu, Xin Zhao, Shen Liu, Gang Li, Wenguo Cui and Cunyi Fan
Int. J. Mol. Sci. 2014, 15(8), 14014-14025; https://doi.org/10.3390/ijms150814014 - 12 Aug 2014
Cited by 36 | Viewed by 8783
Abstract
Infection caused by bacteria is one of the crucial risk factors for tendon adhesion formation. Silver nanoparticles (AgNP)-loaded physical barriers were reported to be effective in anti-infection and anti-adhesion. However, high silver load may lead to kidney and liver damages. This study was [...] Read more.
Infection caused by bacteria is one of the crucial risk factors for tendon adhesion formation. Silver nanoparticles (AgNP)-loaded physical barriers were reported to be effective in anti-infection and anti-adhesion. However, high silver load may lead to kidney and liver damages. This study was designed for Ibuprofen (IBU)-loaded poly(l-lactide) (PLLA) electrospun fibrous membranes containing a low dosage of Ag to evaluate its potential in maintaining suitable anti-infection and good anti-adhesion effects. The in vitro drug release study showed a sustained release of Ag ions and IBU from the membrane. Inferior adherence and proliferation of fibroblasts were found on the Ag4%–IBU4%-loaded PLLA electrospun fibrous membranes in comparison with pure PLLA and 4% Ag-loaded PLLA membranes. In the antibacterial test, all Ag-loaded PLLA electrospun fibrous membranes prevented the adhesion of Staphylococcus aureus and Staphylococcus epidermidis. Taken together, these results demonstrate that Ibuprofen is effective in enhancing the anti-adhesion and anti-proliferation effects of 4% Ag-loaded PLLA fibrous membrane. The medical potential of infection reduction and adhesion prevention of Ag4%–IBU4%-loaded PLLA electrospun fibrous membrane deserves to be further studied. Full article
(This article belongs to the Special Issue Antimicrobial Polymers)
Show Figures

Figure 1

Back to TopTop