Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (15)

Search Parameters:
Keywords = nano-gold conjugated antibodies

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 6304 KiB  
Article
A Monoclonal Antibody-Based Immunochromatographic Test Strip and Its Application in the Rapid Detection of Cucumber Green Mottle Mosaic Virus
by Zichen Zhao, Yanli Tian, Chang Xu, Yuanfei Xing, Lili Yang, Guoliang Qian, Xiude Hua, Weirong Gong, Baishi Hu and Limin Wang
Biosensors 2023, 13(2), 199; https://doi.org/10.3390/bios13020199 - 29 Jan 2023
Cited by 4 | Viewed by 4166
Abstract
Two specific monoclonal antibodies (mAbs) were screened, and an immunochromatographic strip (ICS) test for rapid and specific detection of cucumber green mottle mosaic virus (CGMMV) was developed. The coat protein of CGMMV was heterologously expressed as an immunogen, and specific capture mAb 2C9 [...] Read more.
Two specific monoclonal antibodies (mAbs) were screened, and an immunochromatographic strip (ICS) test for rapid and specific detection of cucumber green mottle mosaic virus (CGMMV) was developed. The coat protein of CGMMV was heterologously expressed as an immunogen, and specific capture mAb 2C9 and the detection mAb 4D4 were screened by an uncompetitive immunoassay. The test and control lines on the nitrocellulose membrane were coated with the purified 2C9 and a goat anti-mouse IgG, respectively, and a nanogold probe combined with 4D4 was applied to the conjugate pad. Using these mAbs, a rapid and sensitive ICS was developed. Within the sandwich mode of 2C9–CGMMV–4D4, the test line showed a corresponding positive relationship with CGMMV in infected samples. The ICS test had a detection limit of 1:5000 (w/v) for CGMMV in samples and was specific for CGMMV, with no observed cross-reaction with TMV or CMV. Full article
(This article belongs to the Special Issue Immunoassays and Biosensing)
Show Figures

Figure 1

14 pages, 3324 KiB  
Review
METCAM Is a Potential Biomarker for Predicting the Malignant Propensity of and as a Therapeutic Target for Prostate Cancer
by Jui-Chuang Wu and Guang-Jer Wu
Biomedicines 2023, 11(1), 205; https://doi.org/10.3390/biomedicines11010205 - 13 Jan 2023
Cited by 3 | Viewed by 2677
Abstract
Prostate cancer is the second leading cause of cancer-related death worldwide. This is because it is still unknown why indolent prostate cancer becomes an aggressive one, though many risk factors for this type of cancer have been suggested. Currently, many diagnostic markers have [...] Read more.
Prostate cancer is the second leading cause of cancer-related death worldwide. This is because it is still unknown why indolent prostate cancer becomes an aggressive one, though many risk factors for this type of cancer have been suggested. Currently, many diagnostic markers have been suggested for predicting malignant prostatic carcinoma cancer; however, only a few, such as PSA (prostate-specific antigen), Prostate Health Index (PHI), and PCA3, have been approved by the FDA. However, each biomarker has its merits as well as shortcomings. The serum PSA test is incapable of differentiating prostate cancer from BPH and also has an about 25% false-positive prediction rate for the malignant status of cancer. The PHI test has the potential to replace the PSA test for the discrimination of BPH from prostate cancer and for the prediction of high-grade cancer avoiding unnecessary biopsies; however, the free form of PSA is unstable and expensive. PCA3 is not associated with locally advanced disease and is limited in terms of its prediction of aggressive cancer. Currently, several urine biomarkers have shown high potential in terms of being used to replace circulating biomarkers, which require a more invasive method of sample collection, such as via serum. Currently, the combined multiple tumor biomarkers may turn out to be a major trend in the diagnosis and assessment of the treatment effectiveness of prostate cancer. Thus, there is still a need to search for more novel biomarkers to develop a perfect cocktail, which consists of multiple biomarkers, in order to predict malignant prostate cancer and follow the efficacy of the treatment. We have discovered that METCAM, a cell adhesion molecule in the Ig-like superfamily, has great potential regarding its use as a biomarker for differentiating prostate cancer from BPH, predicting the malignant propensity of prostate cancer at the early premalignant stage, and differentiating indolent prostate cancers from aggressive cancers. Since METCAM has also been shown to be able to initiate the spread of prostate cancer cell lines to multiple organs, we suggest that it may be used as a therapeutic target for the clinical treatment of patients with malignant prostate cancer. Full article
Show Figures

Figure 1

18 pages, 4067 KiB  
Article
Quantifying Radiosensitization of PSMA-Targeted Gold Nanoparticles on Prostate Cancer Cells at Megavoltage Radiation Energies by Monte Carlo Simulation and Local Effect Model
by Ryder M. Schmidt, Daiki Hara, Jorge D. Vega, Marwan B. Abuhaija, Wensi Tao, Nesrin Dogan, Alan Pollack, John C. Ford and Junwei Shi
Pharmaceutics 2022, 14(10), 2205; https://doi.org/10.3390/pharmaceutics14102205 - 17 Oct 2022
Cited by 17 | Viewed by 3081
Abstract
Active targeting gold nanoparticles (AuNPs) are a very promising avenue for cancer treatment with many publications on AuNP mediated radiosensitization at kilovoltage (kV) photon energies. However, uncertainty on the effectiveness of AuNPs under clinically relevant megavoltage (MV) radiation energies hinders the clinical translation [...] Read more.
Active targeting gold nanoparticles (AuNPs) are a very promising avenue for cancer treatment with many publications on AuNP mediated radiosensitization at kilovoltage (kV) photon energies. However, uncertainty on the effectiveness of AuNPs under clinically relevant megavoltage (MV) radiation energies hinders the clinical translation of AuNP-assisted radiation therapy (RT) paradigm. The aim of this study was to investigate radiosensitization mediated by PSMA-targeted AuNPs irradiated by a 6 MV radiation beam at different depths to explore feasibility of AuNP-assisted prostate cancer RT under clinically relevant conditions. PSMA-targeted AuNPs (PSMA-AuNPs) were synthesized by conjugating PSMA antibodies onto PEGylated AuNPs through EDC/NHS chemistry. Confocal fluorescence microscopy was used to verify the active targeting of the developed PSMA-AuNPs. Transmission electron microscopy (TEM) was used to demonstrate the intracellular biodistribution of PSMA-AuNPs. LNCaP prostate cancer cells treated with PSMA-AuNPs were irradiated on a Varian 6 MV LINAC under varying depths (2.5 cm, 10 cm, 20 cm, 30 cm) of solid water. Clonogenic assays were carried out to determine the in vitro cell survival fractions. A Monte Carlo (MC) model developed on TOPAS platform was then employed to determine the nano-scale radial dose distribution around AuNPs, which was subsequently used to predict the radiation dose response of LNCaP cells treated with AuNPs. Two different cell models, with AuNPs located within the whole cell or only in the cytoplasm, were used to assess how the intracellular PSMA-AuNP biodistribution impacts the prostate cancer radiosensitization. Then, MC-based microdosimetry was combined with the local effect model (LEM) to calculate cell survival fraction, which was benchmarked against the in vitro clonogenic assays at different depths. In vitro clonogenic assay of LNCaP cells demonstrated the depth dependence of AuNP radiosensitization under clinical megavoltage beams, with sensitization enhancement ratio (SER) of 1.14 ± 0.03 and 1.55 ± 0.05 at 2.5 cm depth and 30 cm depth, respectively. The MC microdosimetry model showed the elevated percent of low-energy photons in the MV beams at greater depth, consequently resulting in increased dose enhancement ratio (DER) of AuNPs with depth. The AuNP-induced DER reached ~5.7 and ~8.1 at depths of 2.5 cm and 30 cm, respectively. Microdosimetry based LEM accurately predicted the cell survival under 6 MV beams at different depths, for the cell model with AuNPs placed only in the cell cytoplasm. TEM results demonstrated the distribution of PSMA-AuNPs in the cytoplasm, confirming the accuracy of MC microdosimetry based LEM with modelled AuNPs distributed within the cytoplasm. We conclude that AuNP radiosensitization can be achieved under megavoltage clinical radiotherapy energies with a dependence on tumor depth. Furthermore, the combination of Monte Carlo microdosimetry and LEM will be a valuable tool to assist with developing AuNP-aided radiotherapy paradigm and drive clinical translation. Full article
(This article belongs to the Special Issue Development of Novel Tumor-Targeting Nanoparticles)
Show Figures

Figure 1

14 pages, 2326 KiB  
Article
Ultrasensitive and Rapid Detection of N-Terminal Pro-B-Type Natriuretic Peptide (NT-proBNP) Using Fiber Optic Nanogold-Linked Immunosorbent Assay
by Han-Long Liu, Yen-Ta Tseng, Mei-Chu Lai and Lai-Kwan Chau
Biosensors 2022, 12(9), 746; https://doi.org/10.3390/bios12090746 - 9 Sep 2022
Cited by 17 | Viewed by 4058
Abstract
The N-terminal pro-brain natriuretic peptide (NT-proBNP) is considered an important blood biomarker for heart failure. Herein, we report about a fiber optic nanogold-linked immunosorbent assay (FONLISA) method for the rapid, sensitive, and low-cost detection of NT-proBNP. The method is based on a sandwich [...] Read more.
The N-terminal pro-brain natriuretic peptide (NT-proBNP) is considered an important blood biomarker for heart failure. Herein, we report about a fiber optic nanogold-linked immunosorbent assay (FONLISA) method for the rapid, sensitive, and low-cost detection of NT-proBNP. The method is based on a sandwich immunoassay approach that uses two monoclonal NT-proBNP antibodies, a capture antibody (AbC), and a detection antibody (AbD). AbD is conjugated to a free gold nanoparticle (AuNP) to form the free AuNP@AbD conjugate, and AbC is immobilized on an unclad segment of an optical fiber. The detection of analyte (A), in this case NT-proBNP, is based on the signal change due to the formation of an AuNP@AbD–A–AbC complex on the fiber core surface, where a green light transmitted through the optical fiber will decrease in intensity due to light absorption by AuNPs via the localized surface plasmon resonance effect. This method provides a wide linear dynamic range of 0.50~5000 pg·mL−1 and a limit of detection of 0.058 pg·mL−1 for NT-proBNP. Finally, the method exhibits good correlation (r = 0.979) with the commercial central laboratory-based electrochemiluminescent immunoassay method that uses a Roche Cobas e411 instrument. Hence, our method is potentially a suitable tool for point-of-care testing. Full article
Show Figures

Figure 1

15 pages, 2678 KiB  
Article
A Reliable Approach for Revealing Molecular Targets in Secondary Ion Mass Spectrometry
by Fengxia Li, Eugenio F. Fornasiero, Tal M. Dankovich, Verena Kluever and Silvio O. Rizzoli
Int. J. Mol. Sci. 2022, 23(9), 4615; https://doi.org/10.3390/ijms23094615 - 21 Apr 2022
Cited by 5 | Viewed by 2675
Abstract
Nano secondary ion mass spectrometry (nanoSIMS) imaging is a rapidly growing field in biological sciences, which enables investigators to describe the chemical composition of cells and tissues with high resolution. One of the major challenges of nanoSIMS is to identify specific molecules or [...] Read more.
Nano secondary ion mass spectrometry (nanoSIMS) imaging is a rapidly growing field in biological sciences, which enables investigators to describe the chemical composition of cells and tissues with high resolution. One of the major challenges of nanoSIMS is to identify specific molecules or organelles, as these are not immediately recognizable in nanoSIMS and need to be revealed by SIMS-compatible probes. Few laboratories have generated such probes, and none are commercially available. To address this, we performed a systematic study of probes initially developed for electron microscopy. Relying on nanoscale SIMS, we found that antibodies coupled to 6 nm gold particles are surprisingly efficient in terms of labeling specificity while offering a reliable detection threshold. These tools enabled accurate visualization and sample analysis and were easily employed in correlating SIMS with other imaging approaches, such as fluorescence microscopy. We conclude that antibodies conjugated to moderately sized gold particles are promising tools for SIMS imaging. Full article
(This article belongs to the Special Issue Nano-Materials and Methods 3.0)
Show Figures

Figure 1

27 pages, 7623 KiB  
Review
Ten Approaches That Improve Immunostaining: A Review of the Latest Advances for the Optimization of Immunofluorescence
by Ricardo Piña, Alma I. Santos-Díaz, Erika Orta-Salazar, Azucena Ruth Aguilar-Vazquez, Carola A. Mantellero, Isabel Acosta-Galeana, Argel Estrada-Mondragon, Mara Prior-Gonzalez, Jadir Isai Martinez-Cruz and Abraham Rosas-Arellano
Int. J. Mol. Sci. 2022, 23(3), 1426; https://doi.org/10.3390/ijms23031426 - 26 Jan 2022
Cited by 60 | Viewed by 32835
Abstract
Immunostaining has emerged as one of the most common and valuable techniques that allow the localization of proteins at a quantitative level within cells and tissues using antibodies coupled to enzymes, fluorochromes, or colloidal nanogold particles. The application of fluorochromes during immunolabeling is [...] Read more.
Immunostaining has emerged as one of the most common and valuable techniques that allow the localization of proteins at a quantitative level within cells and tissues using antibodies coupled to enzymes, fluorochromes, or colloidal nanogold particles. The application of fluorochromes during immunolabeling is referred to as immunofluorescence, a method coupled to widefield or confocal microscopy and extensively applied in basic research and clinical diagnosis. Notwithstanding, there are still disadvantages associated with the application of this technique due to technical challenges in the process, such as sample fixation, permeabilization, antibody incubation times, and fluid exchange, etc. These disadvantages call for continuous updates and improvements to the protocols extensively described in the literature. This review contributes to protocol optimization, outlining 10 current methods for improving sample processing in different stages of immunofluorescence, including a section with further recommendations. Additionally, we have extended our own antibody signal enhancer method, which was reported to significantly increase antibody signals and is useful for cervical cancer detection, to improve the signals of fluorochrome-conjugated staining reagents in fibrous tissues. In summary, this review is a valuable tool for experienced researchers and beginners when planning or troubleshooting the immunofluorescence assay. Full article
Show Figures

Graphical abstract

13 pages, 2336 KiB  
Article
Correlative Light-Environmental Scanning Electron Microscopy of Plasma Membrane Efflux Carriers of Plant Hormone Auxin
by Ayoub Stelate, Eva Tihlaříková, Kateřina Schwarzerová, Vilém Neděla and Jan Petrášek
Biomolecules 2021, 11(10), 1407; https://doi.org/10.3390/biom11101407 - 26 Sep 2021
Cited by 19 | Viewed by 3629
Abstract
Fluorescence light microscopy provided convincing evidence for the domain organization of plant plasma membrane (PM) proteins. Both peripheral and integral PM proteins show an inhomogeneous distribution within the PM. However, the size of PM nanodomains and protein clusters is too small to accurately [...] Read more.
Fluorescence light microscopy provided convincing evidence for the domain organization of plant plasma membrane (PM) proteins. Both peripheral and integral PM proteins show an inhomogeneous distribution within the PM. However, the size of PM nanodomains and protein clusters is too small to accurately determine their dimensions and nano-organization using routine confocal fluorescence microscopy and super-resolution methods. To overcome this limitation, we have developed a novel correlative light electron microscopy method (CLEM) using total internal reflection fluorescence microscopy (TIRFM) and advanced environmental scanning electron microscopy (A-ESEM). Using this technique, we determined the number of auxin efflux carriers from the PINFORMED (PIN) family (NtPIN3b-GFP) within PM nanodomains of tobacco cell PM ghosts. Protoplasts were attached to coverslips and immunostained with anti-GFP primary antibody and secondary antibody conjugated to fluorochrome and gold nanoparticles. After imaging the nanodomains within the PM with TIRFM, the samples were imaged with A-ESEM without further processing, and quantification of the average number of molecules within the nanodomain was performed. Without requiring any post-fixation and coating procedures, this method allows to study details of the organization of auxin carriers and other plant PM proteins. Full article
Show Figures

Graphical abstract

14 pages, 2846 KiB  
Article
Aptasensor for the Detection of Mycobacterium tuberculosis in Sputum Utilising CFP10-ESAT6 Protein as a Selective Biomarker
by Umi Zulaikha Mohd Azmi, Nor Azah Yusof, Jaafar Abdullah, Faruq Mohammad, Shahrul Ainliah Alang Ahmad, Siti Suraiya, Nurul Hanun Ahmad Raston, Fatin Nabilah Mohd Faudzi, Sachin K. Khiste and Hamad A. Al-Lohedan
Nanomaterials 2021, 11(9), 2446; https://doi.org/10.3390/nano11092446 - 20 Sep 2021
Cited by 18 | Viewed by 5322
Abstract
A portable electrochemical aptamer-antibody based sandwich biosensor has been designed and successfully developed using an aptamer bioreceptor immobilized onto a screen-printed electrode surface for Mycobacterium tuberculosis (M. tuberculosis) detection in clinical sputum samples. In the sensing strategy, a CFP10-ESAT6 binding aptamer [...] Read more.
A portable electrochemical aptamer-antibody based sandwich biosensor has been designed and successfully developed using an aptamer bioreceptor immobilized onto a screen-printed electrode surface for Mycobacterium tuberculosis (M. tuberculosis) detection in clinical sputum samples. In the sensing strategy, a CFP10-ESAT6 binding aptamer was immobilized onto a graphene/polyaniline (GP/PANI)-modified gold working electrode by covalent binding via glutaraldehyde linkage. Upon interaction with the CFP10-ESAT6 antigen target, the aptamer will capture the target where the nano-labelled Fe3O4/Au MNPs conjugated antibody is used to complete the sandwich format and enhance the signal produced from the aptamer–antigen interaction. Using this strategy, the detection of CFP10-ESAT6 antigen was conducted in the concentration range of 5 to 500 ng/mL. From the analysis, the detection limit was found to be 1.5 ng/mL, thereby demonstrating the efficiency of the aptamer as a bioreceptor. The specificity study was carried out using bovine serum albumin (BSA), MPT64, and human serum, and the result demonstrated good specificity that is 7% higher than the antibody–antigen interaction reported in a previous study. The fabricated aptasensor for M. tuberculosis analysis shows good reproducibility with an relative standard deviation (RSD) of 2.5%. Further analysis of M. tuberculosis in sputum samples have shown good correlation with the culture method with 100% specificity and sensitivity, thus making the aptasensor a promising candidate for M. tuberculosis detection considering its high specificity and sensitivity with clinical samples. Full article
(This article belongs to the Special Issue Functional Nanohybrid Material for Electrochemical Sensor Development)
Show Figures

Figure 1

18 pages, 3945 KiB  
Article
Validating METCAM/MUC18 as a Novel Biomarker to Predict the Malignant Potential of Prostate Cancer at an Early Stage by Using a Modified Gold Nanoparticles-Based Lateral Flow Immunoassay
by Jui-Chuang Wu, Yin-Huan Chuang, Yu-Chun Wei, Chia-Chi Hsieh, Yuan-Hung Pong, Yenn-Rong Su, Vincent F.-S. Tsai and Guang-Jer Wu
Diagnostics 2021, 11(3), 443; https://doi.org/10.3390/diagnostics11030443 - 4 Mar 2021
Cited by 3 | Viewed by 2641
Abstract
(1) Background: To further validate METCAM/MUC18 as a diagnostic biomarker for prostate cancer, a modified Lateral Flow Immune Assay (LFIA) with increased sensitivity and specificity was designed by taking advantage of the extremely high affinity between biotin and streptavidin and used. (2) Methods: [...] Read more.
(1) Background: To further validate METCAM/MUC18 as a diagnostic biomarker for prostate cancer, a modified Lateral Flow Immune Assay (LFIA) with increased sensitivity and specificity was designed by taking advantage of the extremely high affinity between biotin and streptavidin and used. (2) Methods: The combination of a commercial biotinylated rabbit antibody (EPP11278), or the home-made biotinylated chicken antibody, and the nano-gold conjugated home-made chicken antibody or a commercial rabbit antibody (EPP11278), had the higher sensitivity and specificity in this modified LFIA to establish calibration curves from the two recombinant METCAM/MUC18 proteins and were used for determining METCAM/MUC18 concentrations in serum specimens from normal individuals, benign prostatic hyperplasia (BPH) patients, prostatic intraepithelial neoplasia (PIN) patients, prostate cancer patients with various Gleason scores, and treated patients. (3) Results: Data obtained by this modified LFIA were statistically better than traditional LFIA and prostate-specific antigen (PSA) test. Interestingly, serum METCAM/MUC18 concentrations were higher in pre-malignant PIN patients than prostate cancer patients and both were higher than normal individuals, BPH patients, and treated patients. Serum METCAM/MUC18 concentrations were directly proportional to most serum PSA. (4) Conclusions: Elevated serum METCAM/MUC18 concentrations may be used for predicting the malignant potential of prostate cancer at an early premalignant (PIN) stage, which is not achievable by the current PSA test. Full article
(This article belongs to the Section Pathology and Molecular Diagnostics)
Show Figures

Figure 1

14 pages, 3191 KiB  
Article
A Novel Surface-Exposed Polypeptide Is Successfully Employed as a Target for Developing a Prototype One-Step Immunochromatographic Strip for Specific and Sensitive Direct Detection of Staphylococcus aureus Causing Neonatal Sepsis
by Sally A. Mohamed, Tamer M. Samir, Omneya M. Helmy, Noha M. Elhosseiny, Aliaa A. Ali, Amani A. El-Kholy and Ahmed S. Attia
Biomolecules 2020, 10(11), 1580; https://doi.org/10.3390/biom10111580 - 20 Nov 2020
Cited by 8 | Viewed by 4442
Abstract
Neonatal sepsis is a life-threatening condition and Staphylococcus aureus is one of its major causes. However, to date, no rapid and sensitive diagnostic tool has been developed for its direct detection. Bioinformatics analyses identified a surface-exposed 112-amino acid polypeptide of the cell wall [...] Read more.
Neonatal sepsis is a life-threatening condition and Staphylococcus aureus is one of its major causes. However, to date, no rapid and sensitive diagnostic tool has been developed for its direct detection. Bioinformatics analyses identified a surface-exposed 112-amino acid polypeptide of the cell wall protein NWMN_1649, a surface protein involved in cell aggregation and biofilm formation, as being a species-specific and highly conserved moiety. The polypeptide was cloned, purified, and used to immunize mice to raise specific immunoglobulins. The purified antibodies were conjugated to gold nano-particles and used to assemble an immunochromatographic strip (ICS). The developed prototype ICS detected as low as 5 µg purified polypeptide and 102 CFU/mL S. aureus within 15 min. The strip showed superior ability to directly detect S. aureus in neonatal sepsis blood specimens without prior sample processing. Moreover, it showed no cross-reaction in specimens infected with two other major causes of neonatal sepsis; coagulase-negative staphylococci and Klebsiella pneumoniae. The selected NWMN_1649-derived polypeptide demonstrates success as a promising biomolecule upon which a prototype ICS has been developed. This ICS provides a rapid, direct, sensitive, and specific option for the detection of S. aureus causing neonatal sepsis. Such a tool is urgently needed especially in resources-limited countries. Full article
(This article belongs to the Special Issue Pharmacological Approach to Sepsis and Septic Shock)
Show Figures

Graphical abstract

12 pages, 7485 KiB  
Technical Note
Optical Density Optimization of Malaria Pan Rapid Diagnostic Test Strips for Improved Test Zone Band Intensity
by Prince Manta, Rupak Nagraik, Avinash Sharma, Akshay Kumar, Pritt Verma, Shravan Kumar Paswan, Dmitry O. Bokov, Juber Dastagir Shaikh, Roopvir Kaur, Ana Francesca Vommaro Leite, Silas Jose Braz Filho, Nimisha Shiwalkar, Purnadeo Persaud and Deepak N. Kapoor
Diagnostics 2020, 10(11), 880; https://doi.org/10.3390/diagnostics10110880 - 29 Oct 2020
Cited by 11 | Viewed by 5590
Abstract
For the last few decades, the immunochromatographic assay has been used for the rapid detection of biological markers in infectious diseases in humans and animals The assay, also known as lateral flow assay, is utilized for the detection of antigen or antibody in [...] Read more.
For the last few decades, the immunochromatographic assay has been used for the rapid detection of biological markers in infectious diseases in humans and animals The assay, also known as lateral flow assay, is utilized for the detection of antigen or antibody in human infectious diseases. There are a series of steps involved in the development of these immuno-chromatographic test kits, from gold nano colloids preparation to nitrocellulose membrane coating (NCM). These tests are mostly used for qualitative assays by a visual interpretation of results. For the interpretation of the results, the color intensity of the test zone is therefore very significant. Herein, the study was performed on a malaria antigen test kit. Several studies have reported the use of gold nanoparticles (AuNPs) with varying diameters and its binding with various concentrations of protein in order to optimize tests. However, none of these studies have reported how to fix (improve) test zone band intensity (color), if different sized AuNPs were synthesized during a reaction and when conjugated equally with same amount of protein. Herein, different AuNPs with average diameter ranging from 10 nm to 50 nm were prepared and conjugated equally with protein concentration of 150 µg/mL with KD = 1.0 × 10−3. Afterwards, the developed kits’ test zone band intensity for all different sizes AuNPs was fixed to the same band level (high) by utilization of an ultraviolet-visible spectrophotometer. The study found that the same optical density (OD) has the same test zone band intensity irrespective of AuNP size. This study also illustrates the use of absorption maxima (λ max) techniques to characterize AuNPs and to prevent wastage of protein while developing immunochromatographic test kits. Full article
(This article belongs to the Special Issue Point-of-Care Detection Devices for Healthcare)
Show Figures

Graphical abstract

10 pages, 1351 KiB  
Article
Rapid Detection of Escherichia coli O157 and Shiga Toxins by Lateral Flow Immunoassays
by Jinliang Wang, Robab Katani, Lingling Li, Narasimha Hegde, Elisabeth L. Roberts, Vivek Kapur and Chitrita DebRoy
Toxins 2016, 8(4), 92; https://doi.org/10.3390/toxins8040092 - 25 Mar 2016
Cited by 33 | Viewed by 10369
Abstract
Shiga toxin-producing Escherichia coli O157:H7 (STEC) cause food-borne illness that may be fatal. STEC strains enumerate two types of potent Shiga toxins (Stx1 and Stx2) that are responsible for causing diseases. It is important to detect the E. coli O157 and Shiga toxins [...] Read more.
Shiga toxin-producing Escherichia coli O157:H7 (STEC) cause food-borne illness that may be fatal. STEC strains enumerate two types of potent Shiga toxins (Stx1 and Stx2) that are responsible for causing diseases. It is important to detect the E. coli O157 and Shiga toxins in food to prevent outbreak of diseases. We describe the development of two multi-analyte antibody-based lateral flow immunoassays (LFIA); one for the detection of Stx1 and Stx2 and one for the detection of E. coli O157 that may be used simultaneously to detect pathogenic E. coli O157:H7. The LFIA strips were developed by conjugating nano colloidal gold particles with monoclonal antibodies against Stx1 and Stx2 and anti-lipid A antibodies to capture Shiga toxins and O157 antigen, respectively. Our results indicate that the LFIA for Stx is highly specific and detected Stx1 and Stx2 within three hours of induction of STEC with ciprofloxacin at 37 °C. The limit of detection for E. coli O157 LFIA was found to be 105 CFU/mL in ground beef spiked with the pathogen. The LFIAs are rapid, accurate and easy to use and do not require sophisticated equipment or trained personnel. Following the assay, colored bands on the membrane develop for end-point detection. The LFIAs may be used for screening STEC in food and the environment. Full article
(This article belongs to the Collection Rapid Detection of Bacterial Toxins)
Show Figures

Figure 1

12 pages, 1605 KiB  
Article
Facile Attachment of TAT Peptide on Gold Monolayer Protected Clusters: Synthesis and Characterization
by Ndabenhle M. Sosibo, Frankline K. Keter, Amanda Skepu, Robert T. Tshikhudo and Neerish Revaprasadu
Nanomaterials 2015, 5(3), 1211-1222; https://doi.org/10.3390/nano5031211 - 21 Jul 2015
Cited by 14 | Viewed by 6554
Abstract
High affinity thiolate-based polymeric capping ligands are known to impart stability onto nanosized gold nanoparticles. Due to the stable gold-sulfur bond, the ligand forms a protective layer around the gold core and subsequently controls the physicochemical properties of the resultant nanogold mononuclear protected [...] Read more.
High affinity thiolate-based polymeric capping ligands are known to impart stability onto nanosized gold nanoparticles. Due to the stable gold-sulfur bond, the ligand forms a protective layer around the gold core and subsequently controls the physicochemical properties of the resultant nanogold mononuclear protected clusters (AuMPCs). The choice of ligands to use as surfactants for AuMPCs largely depends on the desired degree of hydrophilicity and biocompatibility of the MPCs, normally dictated by the intended application. Subsequent surface modification of AuMPCs allows further conjugation of additional biomolecules yielding bilayer or multilayered clusters suitable for bioanalytical applications ranging from targeted drug delivery to diagnostics. In this study, we discuss our recent laboratory findings on a simple route for the introduction of Trans-Activator of Transcription (TAT) peptide onto the surface of biotin-derivatised gold MPCs via the biotin-strepavidin interaction. By changing the surface loading of biotin, controlled amounts of TAT could be attached. This bioconjugate system is very attractive as a carrier in intercellular delivery of various delivery cargoes such as antibodies, proteins and oligonucleotides. Full article
Show Figures

Figure 1

12 pages, 649 KiB  
Article
A Novel Point-of-Care Biomarker Recognition Method: Validation by Detecting Marker for Diabetic Nephropathy
by Sahana Pentyala, John Muller, Thomas Tumillo, Avijit Roy, Pooja Mysore and Srinivas Pentyala
Diagnostics 2015, 5(2), 177-188; https://doi.org/10.3390/diagnostics5020177 - 23 Apr 2015
Cited by 5 | Viewed by 7031
Abstract
Biological fluid collection to identify and analyze different disease markers is a routine and normal procedure in health care settings. Body fluids are as varied as urine, blood, mucus, cerebrospinal fluid (CSF), tears, semen, etc. The volumes of the collected fluids range from [...] Read more.
Biological fluid collection to identify and analyze different disease markers is a routine and normal procedure in health care settings. Body fluids are as varied as urine, blood, mucus, cerebrospinal fluid (CSF), tears, semen, etc. The volumes of the collected fluids range from micro liters (e.g., tears, CSF) to tens and hundreds of milliliters (blood, urine, etc.). In some manifestations, a disease marker (particularly protein markers) can occur in trace amounts, yet the fluids collected are in large volumes. To identify these trace markers, cumbersome methods, expensive instruments, and trained personnel are required. We developed an easy method to rapidly capture, concentrate, and identify protein markers in large volumes of test fluids. This method involves the utilization of two antibodies recognizing two different epitopes of the protein biomarker. Antibody-1 helps to capture and concentrate the biomarker and Antibody-2 adsorbed or conjugated to nanogold beads will detect the biomarker. This method was validated in capturing and detecting lipocalin type prostaglandin-D2 synthase, a marker in urine that implicates diabetic nephropathy. A one-step collection, concentration, and detection device was designed based on this method. This device can replace many of the normal body fluid collection devices such as tubes and containers. A one-step fluid collection and biomarker capture and concentration device for rapid diagnosis of diseases has tremendous advantage in terms of cost and providing timely results. Full article
(This article belongs to the Special Issue In Vitro Diagnostics)
Show Figures

Figure 1

9 pages, 618 KiB  
Article
Signal Amplification by Enzymatic Reaction in an Immunosensor Based on Localized Surface Plasmon Resonance (LSPR)
by Tae-Han Lee, Seung-Woo Lee, Ji-Ae Jung, Junhyoung Ahn, Min-Gon Kim and Yong-Beom Shin
Sensors 2010, 10(3), 2045-2053; https://doi.org/10.3390/s100302045 - 12 Mar 2010
Cited by 35 | Viewed by 11893
Abstract
An enzymatic reaction was employed as a means to enhance the sensitivity of an immunosensor based on localized surface plasmon resonance (LSPR). The reaction occurs after intermolecular binding between an antigen and an antibody on gold nano-island (NI) surfaces. For LSPR sensing, the [...] Read more.
An enzymatic reaction was employed as a means to enhance the sensitivity of an immunosensor based on localized surface plasmon resonance (LSPR). The reaction occurs after intermolecular binding between an antigen and an antibody on gold nano-island (NI) surfaces. For LSPR sensing, the gold NI surface was fabricated on glass substrates using vacuum evaporation and heat treatment. The interferon-g (IFN-g) capture antibody was immobilized on the gold NIs, followed by binding of IFN-g to the antibody. Subsequently, a biotinylated antibody and a horseradish peroxidase (HRP) conjugated with avidin were simultaneously introduced. A solution of 4-chloro-1-naphthol (4-CN) was then used for precipitation; precipitation was the result of the enzymatic reaction catalyzed the HRP on gold NIs. The LSPR spectra were obtained after each binding process. Using this method, the enzyme-catalyzed precipitation reaction on the gold NI surface was found to effectively amplify the change in the signal of the LSPR immunosensor after intermolecular binding. Full article
(This article belongs to the Special Issue Immunosensors)
Show Figures

Back to TopTop