Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (18)

Search Parameters:
Keywords = modified platinum microelectrode

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 6629 KB  
Article
A Comb-Shaped Flexible Microelectrode Array for Simultaneous Multi-Scale Cortical Recording
by Suyi Zhang, Jin Shan, Shiya Lv, Yu Liu, Jian Miao, Ziyu Liu, Ezhu Ning, Zhaojie Xu, Juntao Liu, Mixia Wang, Hongyan Jin, Xinxia Cai and Yilin Song
Micromachines 2026, 17(3), 301; https://doi.org/10.3390/mi17030301 - 28 Feb 2026
Viewed by 1470
Abstract
High-resolution, multi-modal neural interfaces are essential for advancing systems neuroscience and brain–computer interface technologies. This study designed and fabricated a 128-channel comb-shaped flexible micro-electrode array. The device integrates a biocompatible Parylene substrate with a flexible thin-film microprobe array, enabling simultaneous recording of electrocorticography [...] Read more.
High-resolution, multi-modal neural interfaces are essential for advancing systems neuroscience and brain–computer interface technologies. This study designed and fabricated a 128-channel comb-shaped flexible micro-electrode array. The device integrates a biocompatible Parylene substrate with a flexible thin-film microprobe array, enabling simultaneous recording of electrocorticography (ECoG), intracortical local field potentials (LFP), and neuronal action potentials (spikes) from the cortical surface and superficial layers. Microelectrode sites were modified with platinum black nanoparticles, significantly reducing impedance. In vivo experiments in rats demonstrated the array’s ability to capture high-fidelity signals across different recording depths. Key findings included the acquisition of opposing LFP trends and polarity reversals between adjacent channels, reflecting local microcircuit dynamics. The array also reliably recorded neural activity during audiovisual cross-modal sensory stimulation. These results validate the device as an effective tool for multi-scale electrophysiology, successfully balancing high spatial resolution and signal quality with minimal tissue invasiveness, thereby offering significant potential for fundamental research and neural engineering applications. Full article
(This article belongs to the Special Issue Neural Microelectrodes for Brain–Computer Interfaces)
Show Figures

Figure 1

12 pages, 4553 KB  
Article
A Biomimetic Chip with Dendrimer-Encapsulated Platinum Nanoparticles for Enhanced Electrochemiluminescence Detection of Cardiac Troponin I
by Yun Hui, Weijun Kong, Weiliang Shu, Zhiting Peng, Fengshan Shen, Mingyang Jiang, Zhen Xu, Tianzhun Wu, Wenhua Zhou and Xue-Feng Yu
Chemosensors 2024, 12(10), 214; https://doi.org/10.3390/chemosensors12100214 - 16 Oct 2024
Cited by 1 | Viewed by 2203
Abstract
The measurement of cardiac troponin I (cTnI) is of vital importance for the early diagnosis of acute myocardial infarction. In this study, an enhanced electrochemiluminescent immunoassay for the highly sensitive and precise determination of cTnI was reported. A biomimetic chip with nepenthes peristome [...] Read more.
The measurement of cardiac troponin I (cTnI) is of vital importance for the early diagnosis of acute myocardial infarction. In this study, an enhanced electrochemiluminescent immunoassay for the highly sensitive and precise determination of cTnI was reported. A biomimetic chip with nepenthes peristome surface microstructures to achieve single-layer microbead arrays and integrated microelectrode arrays (MEAs) for ECL detection was microfabricated. Ru@SiO2 nanoparticles were prepared as signal amplificators labeling immunomagnetic beads. Dendrimer-encapsulated platinum nanoparticles (Pt DENs) were electrochemically modified on ITO MEAs. The resulting Pt DEN-modified ITO MEAs preserved good optical transparency and exhibited an approximately 20-fold ECL signal amplification compared to that obtained from bare ITO. The method made full use of the biomimetic chip with Pt DENs to develop single-layer immunomagnetic bead arrays with increasingly catalyzed electrochemical oxidation of the [Ru(bpy)3]2+–TPA system. Consequently, a limit of detection calculated as 0.38 pg/mL (S/N = 3) was obtained with excellent selectivity, demonstrating significant potential for the detection of cTnI in clinical diagnostics. Full article
(This article belongs to the Special Issue Application of Luminescent Materials for Sensing, 2nd Edition)
Show Figures

Figure 1

14 pages, 1396 KB  
Article
Dopamine Measurement Using Engineered CNT–CQD–Polymer Coatings on Pt Microelectrodes
by Mahdieh Darroudi, Kevin A. White, Matthew A. Crocker and Brian N. Kim
Sensors 2024, 24(6), 1893; https://doi.org/10.3390/s24061893 - 15 Mar 2024
Cited by 7 | Viewed by 3758
Abstract
This study aims to develop a microelectrode array-based neural probe that can record dopamine activity with high stability and sensitivity. To mimic the high stability of the gold standard method (carbon fiber electrodes), the microfabricated platinum microelectrode is coated with carbon-based nanomaterials. Carboxyl-functionalized [...] Read more.
This study aims to develop a microelectrode array-based neural probe that can record dopamine activity with high stability and sensitivity. To mimic the high stability of the gold standard method (carbon fiber electrodes), the microfabricated platinum microelectrode is coated with carbon-based nanomaterials. Carboxyl-functionalized multi-walled carbon nanotubes (COOH-MWCNTs) and carbon quantum dots (CQDs) were selected for this purpose, while a conductive polymer like poly (3-4-ethylene dioxythiophene) (PEDOT) or polypyrrole (PPy) serves as a stable interface between the platinum of the electrode and the carbon-based nanomaterials through a co-electrodeposition process. Based on our comparison between different conducting polymers and the addition of CQD, the CNT–CQD–PPy modified microelectrode outperforms its counterparts: CNT–CQD–PEDOT, CNT–PPy, CNT–PEDOT, and bare Pt microelectrode. The CNT–CQD–PPy modified microelectrode has a higher conductivity, stability, and sensitivity while achieving a remarkable limit of detection (LOD) of 35.20 ± 0.77 nM. Using fast-scan cyclic voltammetry (FSCV), these modified electrodes successfully measured dopamine’s redox peaks while exhibiting consistent and reliable responses over extensive use. This electrode modification not only paves the way for real-time, precise dopamine sensing using microfabricated electrodes but also offers a novel electrochemical sensor for in vivo studies of neural network dynamics and neurological disorders. Full article
(This article belongs to the Special Issue Nanomaterials-Based Sensors for Biomedical Monitoring)
Show Figures

Figure 1

11 pages, 2352 KB  
Article
Localised Electrochemical Impedance Spectroscopy of Gold Nanoparticles Labelled Antibodies Probed by Platinum Microstructured Ultramicroelectrode
by Antanas Zinovicius, Inga Morkvenaite-Vilkonciene and Arunas Ramanavicius
Materials 2024, 17(6), 1339; https://doi.org/10.3390/ma17061339 - 14 Mar 2024
Cited by 1 | Viewed by 2408
Abstract
This research is focused on enhancing the capabilities of scanning electrochemical impedance microscopy (SEIM) for detecting gold nanoparticle-labelled antibodies using electrochemically modified platinum ultramicroelectrode. The primary objective was to address the high resistance issue encountered in previous measurements with SEIM via the utilization [...] Read more.
This research is focused on enhancing the capabilities of scanning electrochemical impedance microscopy (SEIM) for detecting gold nanoparticle-labelled antibodies using electrochemically modified platinum ultramicroelectrode. The primary objective was to address the high resistance issue encountered in previous measurements with SEIM via the utilization of SEIM probes based on micro-electrodes modified by platinum microstructures, which improved the sensitivity and precision of the detection of targeted biomolecules. The modified probe resulted in a lowered charge transfer resistance by over ten times and a decrease in detection to around 100 fg/mL. We suggest potential applications in various biotechnological and biomedical fields, with future research expected to further refine this technique. Full article
Show Figures

Figure 1

14 pages, 3195 KB  
Article
Highly Activated Neuronal Firings Monitored by Implantable Microelectrode Array in the Paraventricular Thalamus of Insomnia Rats
by Jin Shan, Yilin Song, Yiding Wang, Penghui Fan, Botao Lu, Jinping Luo, Wei Xu, Luyi Jing, Fan Mo, Ruilin Hu, Yan Luo, Gang Mao, Ying Wang and Xinxia Cai
Sensors 2023, 23(10), 4629; https://doi.org/10.3390/s23104629 - 10 May 2023
Cited by 5 | Viewed by 3364
Abstract
Insomnia is a common sleep disorder around the world, which is harmful to people’s health, daily life, and work. The paraventricular thalamus (PVT) plays an essential role in the sleep–wake transition. However, high temporal-spatial resolution microdevice technology is lacking for accurate detection and [...] Read more.
Insomnia is a common sleep disorder around the world, which is harmful to people’s health, daily life, and work. The paraventricular thalamus (PVT) plays an essential role in the sleep–wake transition. However, high temporal-spatial resolution microdevice technology is lacking for accurate detection and regulation of deep brain nuclei. The means for analyzing sleep–wake mechanisms and treating sleep disorders are limited. To detect the relationship between the PVT and insomnia, we designed and fabricated a special microelectrode array (MEA) to record electrophysiological signals of the PVT for insomnia and control rats. Platinum nanoparticles (PtNPs) were modified onto an MEA, which caused the impedance to decrease and improved the signal-to-noise ratio. We established the model of insomnia in rats and analyzed and compared the neural signals in detail before and after insomnia. In insomnia, the spike firing rate was increased from 5.48 ± 0.28 spike/s to 7.39 ± 0.65 spike/s, and the power of local field potential (LFP) decreased in the delta frequency band and increased in the beta frequency band. Furthermore, the synchronicity between PVT neurons declined, and burst-like firing was observed. Our study found neurons of the PVT were more activated in the insomnia state than in the control state. It also provided an effective MEA to detect the deep brain signals at the cellular level, which conformed with macroscopical LFP and insomnia symptoms. These results laid the foundation for studying PVT and the sleep–wake mechanism and were also helpful for treating sleep disorders. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

18 pages, 6582 KB  
Article
Application of Molecularly Imprinted Microelectrode as a Promising Point-of-Care Biosensor for Alanine Aminotransferase Enzyme
by Mostafa Ahmed Samy, Muhammed Abdel-Hamied Abdel-Tawab, Nour. T. Abdel-Ghani and Rasha M. El Nashar
Chemosensors 2023, 11(5), 262; https://doi.org/10.3390/chemosensors11050262 - 27 Apr 2023
Cited by 10 | Viewed by 3808
Abstract
Alanine amino transaminase (ALT) is an enzyme that can be used as a biomarker for liver injury and other diseases. In this work, we report the development of the first microelectrode based on a molecularly imprinted pyruvate oxidase enzyme to be applied as [...] Read more.
Alanine amino transaminase (ALT) is an enzyme that can be used as a biomarker for liver injury and other diseases. In this work, we report the development of the first microelectrode based on a molecularly imprinted pyruvate oxidase enzyme to be applied as an electrochemical biosensor for ALT detection. The biosensor is based on pyruvate oxidase enzyme (POx), imprinted using 4-aminophenol (functional monomer-on-platinum microelectrode modified (PME)) with platinum nanoparticles and 4-aminoantypirine (4-AAP)/sodium pyruvate as an electrochemical indicator. The operational conditions of the biosensor were optimized and characterized morphologically using scanning electron microscopy (SEM) and electrochemically using electrochemical impedance spectroscopy (EIS). The biosensor was found to have a fast response towards ALT within a linear range of 25–700 U/L and a limit of detection of 2.97 U/L. The biosensor did not exhibit cross-reactivity towards other tested enzymes, including nicotinamide adenine dinucleotide (Beta-NAD), catalase (CAT), glutathione peroxidase (GPx), and L-glutathione reduced (GSH) enzymes. The biosensor was efficiently applied for the assay of ALT in plasma samples; with recovery values ranging from 99.80–103.82% and RSD of values 0.27–2.01% and these results were found to be comparable to those of the reference diagnostic kits, without any need for complicated procedures or protein extraction. In addition to being highly sensitive, low cost, and portable, the use of microelectrodes allows the application of the proposed sensor for point-of-care diagnostics of liver function and online monitoring of ALT levels in hospitalized patients without the need for withdrawing samples, which indicates the promising applicability of the presented ALT sensor for point-of-care diagnostics. Full article
(This article belongs to the Special Issue Advances in Chemosensors Technologies for Monitoring and Diagnostics)
Show Figures

Figure 1

14 pages, 2366 KB  
Article
Microfluidic Platform Integrated with Carbon Nanofibers-Decorated Gold Nanoporous Sensing Device for Serum PSA Quantification
by Emiliano Felici, Matías D. Regiart, Sirley V. Pereira, Francisco G. Ortega, Lúcio Angnes, Germán A. Messina and Martín A. Fernández-Baldo
Biosensors 2023, 13(3), 390; https://doi.org/10.3390/bios13030390 - 16 Mar 2023
Cited by 17 | Viewed by 5770
Abstract
Prostate cancer is a disease with a high incidence and mortality rate in men worldwide. Serum prostate-specific antigens (PSA) are the main circulating biomarker for this disease in clinical practices. In this work, we present a portable and reusable microfluidic device for PSA [...] Read more.
Prostate cancer is a disease with a high incidence and mortality rate in men worldwide. Serum prostate-specific antigens (PSA) are the main circulating biomarker for this disease in clinical practices. In this work, we present a portable and reusable microfluidic device for PSA quantification. This device comprises a polymethyl methacrylate microfluidic platform coupled with electrochemical detection. The platinum working microelectrode was positioned in the outflow region of the microchannel and was modified with carbon nanofibers (CNF)-decorated gold nanoporous (GNP) structures by the dynamic hydrogen bubble template method, through the simultaneous electrodeposition of metal precursors in the presence of CNF. CNF/GNP structures exhibit attractive properties, such as a large surface to volume ratio, which increases the antibody’s immobilization capacity and the electroactive area. CNFs/GNP structures were characterized by scanning electron microscopy, energy dispersive spectrometry, and cyclic voltammetry. Anti-PSA antibodies and HRP were employed for the immune-electrochemical reaction. The detection limit for the device was 5 pg mL−1, with a linear range from 0.01 to 50 ng mL−1. The coefficients of variation within and between assays were lower than 4.40%, and 6.15%, respectively. Additionally, its clinical performance was tested in serum from 30 prostate cancer patients. This novel device was a sensitive, selective, portable, and reusable tool for the serological diagnosis and monitoring of prostate cancer. Full article
(This article belongs to the Special Issue Nanomaterial Based Biosensors for Biomedical Applications)
Show Figures

Figure 1

14 pages, 3078 KB  
Article
Nanocone-Array-Based Platinum-Iridium Oxide Neural Microelectrodes: Structure, Electrochemistry, Durability and Biocompatibility Study
by Qi Zeng, Shoujun Yu, Zihui Fan, Yubin Huang, Bing Song and Tian Zhou
Nanomaterials 2022, 12(19), 3445; https://doi.org/10.3390/nano12193445 - 1 Oct 2022
Cited by 32 | Viewed by 5160
Abstract
Neural interfaces provide a window for bio-signal modulation and recording with the assistance of neural microelectrodes. However, shrinking the size of electrodes results in high electrochemical impedance and low capacitance, thus limiting the stimulation/recording efficiency. In order to achieve critical stability and low [...] Read more.
Neural interfaces provide a window for bio-signal modulation and recording with the assistance of neural microelectrodes. However, shrinking the size of electrodes results in high electrochemical impedance and low capacitance, thus limiting the stimulation/recording efficiency. In order to achieve critical stability and low power consumption, here, nanocone-shaped platinum (Pt) with an extensive surface area is proposed as an adhesive layer on a bare Pt substrate, followed by the deposition of a thin layer of iridium oxide (IrOx) to fabricate high-performance nanocone-array-based Pt-IrOx neural microelectrodes (200 μm in diameter). A uniform nanocone-shaped Pt with significant roughness is created via controlling the ratio of NH4+ and Pt4+ ions in the electrolyte, which can be widely applicable for batch production on multichannel flexible microelectrode arrays (fMEAs) and various substrates with different dimensions. The Pt-IrOx nanocomposite-coated microelectrode presents a significantly low impedance down to 0.72 ± 0.04 Ω cm2 at 1 kHz (reduction of ~92.95%). The cathodic charge storage capacity (CSCc) and charge injection capacity (CIC) reaches up to 52.44 ± 2.53 mC cm2 and 4.39 ± 0.36 mC cm2, respectively. Moreover, superior chronic stability and biocompatibility are also observed. The modified microelectrodes significantly enhance the adhesion of microglia, the major immune cells in the central nervous system. Therefore, such a coating strategy presents great potential for biomedical and other practical applications. Full article
Show Figures

Figure 1

13 pages, 2421 KB  
Article
Neuronal Electrophysiological Activities Detection of Defense Behaviors Using an Implantable Microelectrode Array in the Dorsal Periaqueductal Gray
by Botao Lu, Penghui Fan, Yiding Wang, Yuchuan Dai, Jingyu Xie, Gucheng Yang, Fan Mo, Zhaojie Xu, Yilin Song, Juntao Liu and Xinxia Cai
Biosensors 2022, 12(4), 193; https://doi.org/10.3390/bios12040193 - 25 Mar 2022
Cited by 14 | Viewed by 3848
Abstract
Defense is the basic survival mechanism of animals when facing dangers. Previous studies have shown that the midbrain periaqueduct gray (PAG) was essential for the production of defense responses. However, the correlation between the endogenous neuronal activities of the dorsal PAG (dPAG) and [...] Read more.
Defense is the basic survival mechanism of animals when facing dangers. Previous studies have shown that the midbrain periaqueduct gray (PAG) was essential for the production of defense responses. However, the correlation between the endogenous neuronal activities of the dorsal PAG (dPAG) and different defense behaviors was still unclear. In this article, we designed and manufactured microelectrode arrays (MEAs) whose detection sites were arranged to match the shape and position of dPAG in rats, and modified it with platinum-black nanoparticles to improve the detection performance. Subsequently, we successfully recorded the electrophysiological activities of dPAG neurons via designed MEAs in freely behaving rats before and after exposure to the potent analog of predator odor 2-methyl-2-thiazoline (2-MT). Results demonstrated that 2-MT could cause strong innate fear and a series of defensive behaviors, accompanied by the significantly increased average firing rate and local field potential (LFP) power of neurons in dPAG. We also observed that dPAG participated in different defense behaviors with different degrees of activation, which was significantly stronger in the flight stage. Further analysis showed that the neuronal activities of dPAG neurons were earlier than flight, and the intensity of activation was inversely proportional to the distance from predator odor. Overall, our results indicate that dPAG neuronal activities play a crucial role in controlling different types of predator odor-evoked innate fear/defensive behaviors, and provide some guidance for the prediction of defense behavior. Full article
Show Figures

Figure 1

12 pages, 5564 KB  
Article
Flexible Neural Probes with Optical Artifact-Suppressing Modification and Biofriendly Polypeptide Coating
by Minghao Wang, Ye Fan, Lili Li, Fei Wen, Bangbang Guo, Minyi Jin, Jiahui Xu, Yuhao Zhou, Xiaoyang Kang, Bowen Ji, Yuhua Cheng and Gaofeng Wang
Micromachines 2022, 13(2), 199; https://doi.org/10.3390/mi13020199 - 27 Jan 2022
Cited by 13 | Viewed by 4046
Abstract
The advent of optogenetics provides a well-targeted tool to manipulate neurons because of its high time resolution and cell-type specificity. Recently, closed-loop neural manipulation techniques consisting of optical stimulation and electrical recording have been widely used. However, metal microelectrodes exposed to light radiation [...] Read more.
The advent of optogenetics provides a well-targeted tool to manipulate neurons because of its high time resolution and cell-type specificity. Recently, closed-loop neural manipulation techniques consisting of optical stimulation and electrical recording have been widely used. However, metal microelectrodes exposed to light radiation could generate photoelectric noise, thus causing loss or distortion of neural signal in recording channels. Meanwhile, the biocompatibility of neural probes remains to be improved. Here, five kinds of neural interface materials are deposited on flexible polyimide-based neural probes and illuminated with a series of blue laser pulses to study their electrochemical performance and photoelectric noises for single-unit recording. The results show that the modifications can not only improve the electrochemical performance, but can also reduce the photoelectric artifacts. In particular, the double-layer composite consisting of platinum-black and conductive polymer has the best comprehensive performance. Thus, a layer of polypeptide is deposited on the entire surface of the double-layer modified neural probes to further improve their biocompatibility. The results show that the biocompatible polypeptide coating has little effect on the electrochemical performance of the neural probe, and it may serve as a drug carrier due to its special micromorphology. Full article
Show Figures

Figure 1

13 pages, 2464 KB  
Article
A Minimally Invasive Microsensor Specially Designed for Simultaneous Dissolved Oxygen and pH Biofilm Profiling
by Xavier Guimerà, Ana Moya, Antonio David Dorado, Xavi Illa, Rosa Villa, David Gabriel, Xavier Gamisans and Gemma Gabriel
Sensors 2019, 19(21), 4747; https://doi.org/10.3390/s19214747 - 1 Nov 2019
Cited by 15 | Viewed by 5890
Abstract
A novel sensing device for simultaneous dissolved oxygen (DO) and pH monitoring specially designed for biofilm profiling is presented in this work. This device enabled the recording of instantaneous DO and pH dynamic profiles within biofilms, improving the tools available for the study [...] Read more.
A novel sensing device for simultaneous dissolved oxygen (DO) and pH monitoring specially designed for biofilm profiling is presented in this work. This device enabled the recording of instantaneous DO and pH dynamic profiles within biofilms, improving the tools available for the study and the characterization of biological systems. The microsensor consisted of two parallel arrays of microelectrodes. Microelectrodes used for DO sensing were bare gold electrodes, while microelectrodes used for pH sensing were platinum-based electrodes modified using electrodeposited iridium oxide. The device was fabricated with a polyimide (Kapton®) film of 127 µm as a substrate for minimizing the damage caused on the biofilm structure during its insertion. The electrodes were covered with a Nafion® layer to increase sensor stability and repeatability and to avoid electrode surface fouling. DO microelectrodes showed a linear response in the range 0–8 mg L−1, a detection limit of 0.05 mg L−1, and a sensitivity of 2.06 nA L mg−1. pH electrodes showed a linear super-Nernstian response (74.2 ± 0.7 mV/pH unit) in a wide pH range (pH 4−9). The multi-analyte sensor array was validated in a flat plate bioreactor where simultaneous and instantaneous pH and DO profiles within a sulfide oxidizing biofilm were recorded. The electrodes spatial resolution, the monitoring sensitivity, and the minimally invasive features exhibited by the proposed microsensor improved biofilm monitoring performance, enabling the quantification of mass transfer resistances and the assessment of biological activity. Full article
(This article belongs to the Special Issue Advanced Electrochemical Sensors and Environmental Monitoring)
Show Figures

Graphical abstract

16 pages, 3968 KB  
Article
Formation of 3-Dimensional Gold, Copper and Palladium Microelectrode Arrays for Enhanced Electrochemical Sensing Applications
by Catherine E. Hay, Junqiao Lee and Debbie S. Silvester
Nanomaterials 2019, 9(8), 1170; https://doi.org/10.3390/nano9081170 - 15 Aug 2019
Cited by 15 | Viewed by 6457
Abstract
Microelectrodes offer higher current density and lower ohmic drop due to increased radial diffusion. They are beneficial for electroanalytical applications, particularly for the detection of analytes at trace concentrations. Microelectrodes can be fabricated as arrays to improve the current response, but are presently [...] Read more.
Microelectrodes offer higher current density and lower ohmic drop due to increased radial diffusion. They are beneficial for electroanalytical applications, particularly for the detection of analytes at trace concentrations. Microelectrodes can be fabricated as arrays to improve the current response, but are presently only commercially available with gold or platinum electrode surfaces, thus limiting the sensing of analytes that are more electroactive on other surfaces. In this work, gold (Au), copper (Cu), and palladium (Pd) are electrodeposited at two different potentials into the recessed holes of commercial microelectrode arrays to produce 3-dimensional (3D) spiky, dendritic or coral-like structures. The rough fractal structures that are produced afford enhanced electroactive surface area and increased radial diffusion due to the 3D nature, which drastically improves the sensitivity. 2,4,6-trinitrotoluene (TNT), carbon dioxide gas (CO2), and hydrogen gas (H2) were chosen as model analytes in room temperature ionic liquid solvents, to demonstrate improvements in the sensitivity of the modified microelectrode arrays, and, in some cases (e.g., for CO2 and H2), enhancements in the electrocatalytic ability. With the deposition of different materials, we have demonstrated enhanced sensitivity and electrocatalytic behaviour towards the chosen analytes. Full article
Show Figures

Figure 1

8 pages, 2389 KB  
Article
Fabrication of Iridium Oxide/Platinum Composite Film on Titanium Substrate for High-Performance Neurostimulation Electrodes
by Tsai-Wei Chung, Chih-Ning Huang, Po-Chun Chen, Toshihiko Noda, Takashi Tokuda and Jun Ohta
Coatings 2018, 8(12), 420; https://doi.org/10.3390/coatings8120420 - 23 Nov 2018
Cited by 11 | Viewed by 6186
Abstract
Electrode materials for neural stimulation have been widely investigated for implantable devices. Among them, iridium and iridium oxide are attractive materials for bio-interface applications due to their desirable stability, electrochemical performance, and biocompatibility. In this study, iridium oxide/platinum (IrOx/Pt) composite films [...] Read more.
Electrode materials for neural stimulation have been widely investigated for implantable devices. Among them, iridium and iridium oxide are attractive materials for bio-interface applications due to their desirable stability, electrochemical performance, and biocompatibility. In this study, iridium oxide/platinum (IrOx/Pt) composite films were successfully fabricated on titanium substrates by chemical bath deposition and these films are expected to be used as biocompatible stimulation electrodes. We modified the film compositions to optimize the performances. In addition, these IrOx/Pt composite films were characterized before and after annealing by SEM and XRD. We also identified the hydrophilicity of these iridium oxide/platinum composite films by measuring contact angles. Finally, the charge storage capacities of these iridium oxide/platinum composite films were evaluated by an electrochemical workstation. As a result, the charge storage capacities of the iridium oxide/platinum composite films are largely increased, and this leads to a very efficient neurostimulation electrode. Additionally, we successfully demonstrated the chemical bath deposition of IrOx film on the surface of the bullet-shaped titanium microelectrode. Full article
Show Figures

Figure 1

14 pages, 4370 KB  
Article
Modification of Microelectrode Arrays with High Surface Area Dendritic Platinum 3D Structures: Enhanced Sensitivity for Oxygen Detection in Ionic Liquids
by Ghulam Hussain, Anthony P. O’Mullane and Debbie S. Silvester
Nanomaterials 2018, 8(9), 735; https://doi.org/10.3390/nano8090735 - 17 Sep 2018
Cited by 12 | Viewed by 5631
Abstract
Electrochemical gas sensors are often used for identifying and quantifying redox-active analyte gases in the atmosphere. However, for amperometric sensors, the current signal is usually dependent on the electroactive surface area, which can become small when using microelectrodes and miniaturized devices. Microarray thin-film [...] Read more.
Electrochemical gas sensors are often used for identifying and quantifying redox-active analyte gases in the atmosphere. However, for amperometric sensors, the current signal is usually dependent on the electroactive surface area, which can become small when using microelectrodes and miniaturized devices. Microarray thin-film electrodes (MATFEs) are commercially available, low-cost devices that give enhanced current densities compared to mm-sized electrodes, but still give low current responses (e.g., less than one nanoamp), when detecting low concentrations of gases. To overcome this, we have modified the surface of the MATFEs by depositing platinum into the recessed holes to create arrays of 3D structures with high surface areas. Dendritic structures have been formed using an additive, lead acetate (Pb(OAc)2) into the plating solution. One-step and two-step depositions were explored, with a total deposition time of 300 s or 420 s. The modified MATFEs were then studied for their behavior towards oxygen reduction in the room temperature ionic liquid (RTIL) [N8,2,2,2][NTf2]. Significantly enhanced currents for oxygen were observed, ranging from 9 to 16 times the current of the unmodified MATFE. The highest sensitivity was obtained using a two-step deposition with a total time of 420 s, and both steps containing Pb(OAc)2. This work shows that commercially-available microelectrodes can be favorably modified to give significantly enhanced analytical performances. Full article
(This article belongs to the Special Issue Nanomaterials for Electrocatalytic Applications in Energy and Sensing)
Show Figures

Figure 1

8 pages, 2077 KB  
Article
In Situ Real-Time Monitoring of Glutamate and Electrophysiology from Cortex to Hippocampus in Mice Based on a Microelectrode Array
by Xinyi Fan, Yilin Song, Yuanlin Ma, Song Zhang, Guihua Xiao, Lili Yang, Huiren Xu, Dai Zhang and Xinxia Cai
Sensors 2017, 17(1), 61; https://doi.org/10.3390/s17010061 - 30 Dec 2016
Cited by 23 | Viewed by 8389
Abstract
Changes in the structure and function of the hippocampus contribute to epilepsy, schizophrenia and other neurological or mental disorders of the brain. Since the function of the hippocampus depends heavily on the glutamate (Glu) signaling pathways, in situ real-time detection of Glu neurotransmitter [...] Read more.
Changes in the structure and function of the hippocampus contribute to epilepsy, schizophrenia and other neurological or mental disorders of the brain. Since the function of the hippocampus depends heavily on the glutamate (Glu) signaling pathways, in situ real-time detection of Glu neurotransmitter release and electrophysiological signals in hippocampus is of great significance. To achieve the dual-mode detection in mouse hippocampus in vivo, a 16-channel implantable microelectrode array (MEA) was fabricated by micro-electromechanical system (MEMS) technology. Twelve microelectrode sites were modified with platinum black for electrophysiological recording and four sites were modified with glutamate oxidase (GluOx) and 1,3-phenylenediamine (mPD) for selective electrochemical detection of Glu. The MEA was implanted from cortex to hippocampus in mouse brain for in situ real-time monitoring of Glu and electrophysiological signals. It was found that the Glu concentration in hippocampus was roughly 50 μM higher than that in the cortex, and the firing rate of concurrently recorded spikes declined from 6.32 ± 4.35 spikes/s in cortex to 0.09 ± 0.06 spikes/s in hippocampus. The present results demonstrated that the dual-mode MEA probe was capable in neurological detections in vivo with high spatial resolution and dynamical response, which lays the foundation for further pathology studies in the hippocampus of mouse models with nervous or mental disorders. Full article
(This article belongs to the Special Issue Nanobiosensing for Sensors)
Show Figures

Graphical abstract

Back to TopTop