Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (6)

Search Parameters:
Keywords = lab vs. home

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 985 KB  
Article
In-Laboratory Polysomnography Worsens Obstructive Sleep Apnea by Changing Body Position Compared to Home Testing
by Raquel Chartuni Pereira Teixeira and Michel Burihan Cahali
Sensors 2024, 24(9), 2803; https://doi.org/10.3390/s24092803 - 27 Apr 2024
Cited by 10 | Viewed by 4529
Abstract
(1) Background: Home sleep apnea testing, known as polysomnography type 3 (PSG3), underestimates respiratory events in comparison with in-laboratory polysomnography type 1 (PSG1). Without head electrodes for scoring sleep and arousal, in a home environment, patients feel unfettered and move their bodies more [...] Read more.
(1) Background: Home sleep apnea testing, known as polysomnography type 3 (PSG3), underestimates respiratory events in comparison with in-laboratory polysomnography type 1 (PSG1). Without head electrodes for scoring sleep and arousal, in a home environment, patients feel unfettered and move their bodies more naturally. Adopting a natural position may decrease obstructive sleep apnea (OSA) severity in PSG3, independently of missing hypopneas associated with arousals. (2) Methods: Patients with suspected OSA performed PSG1 and PSG3 in a randomized sequence. We performed an additional analysis, called reduced polysomnography, in which we blindly reassessed all PSG1 tests to remove electroencephalographic electrodes, electrooculogram, and surface electromyography data to estimate the impact of not scoring sleep and arousal-based hypopneas on the test results. A difference of 15 or more in the apnea–hypopnea index (AHI) between tests was deemed clinically relevant. We compared the group of patients with and without clinically relevant differences between lab and home tests (3) Results: As expected, by not scoring sleep, there was a decrease in OSA severity in the lab test, similar to the home test results. The group of patients with clinically relevant differences between lab and home tests presented more severe OSA in the lab compared to the other group (mean AHI, 42.5 vs. 20.2 events/h, p = 0.002), and this difference disappeared in the home test. There was no difference between groups in the shift of OSA severity by abolishing sleep scoring in the lab. However, by comparing lab and home tests, there were greater variations in supine AHI and time spent in the supine position in the group with a clinically relevant difference, either with or without scoring sleep, showing an impact of the site of the test on body position during sleep. These variations presented as a marked increase or decrease in supine outcomes according to the site of the test, with no particular trend. (4) Conclusions: In-lab polysomnography may artificially increase OSA severity in a subset of patients by inducing marked changes in body position compared to home tests. The location of the sleep test seems to interfere with the evaluation of patients with more severe OSA. Full article
(This article belongs to the Special Issue Sensors for Breathing Monitoring)
Show Figures

Figure 1

11 pages, 1761 KB  
Article
Treatment Durations and Whitening Outcomes of Different Tooth Whitening Systems
by Xiaoyi Zhao, Jie Pan, Hans Malmstrom and Yanfang Ren
Medicina 2023, 59(6), 1130; https://doi.org/10.3390/medicina59061130 - 12 Jun 2023
Cited by 9 | Viewed by 10978
Abstract
Background and Objectives: Tooth whitening is a relatively conservative and effective option to treat discolored teeth. However, questions remain whether in-office or at-home tooth whitening products with short treatment durations are as effective and stable as products with longer treatment durations. Materials [...] Read more.
Background and Objectives: Tooth whitening is a relatively conservative and effective option to treat discolored teeth. However, questions remain whether in-office or at-home tooth whitening products with short treatment durations are as effective and stable as products with longer treatment durations. Materials and Methods: Forty human third molars with intact enamel surfaces were divided into four groups of ten each, subjected to discoloration challenges with coffee for 60 h, and they were treated with four professional tooth whitening systems: two for take-home use—6% hydrogen peroxide for 30 min/d for a total of 7 h in 14 days (HP6), 10% carbamide peroxide for 10 h/d for 140 h in 14 days (CP10), as well as two for in-office use—35% HP for 10 min × 3 (HP35) for a total of 30 min and 40% HP for 20 min × 3 (HP40) for a total of 60 min. Teeth colors were assessed in the CIE L*a*b* color space with a spectrophotometer immediately and six months after whitening treatments. Surface roughness (Sa) for the treated and untreated enamel surfaces of the teeth in all groups were evaluated with a three-dimensional laser scanning microscope after six months. Results: No significant differences were found between HP6 and CP10 groups immediately after whitening (∆E 10.6 ± 1.6 vs. 11.4 ± 1.7, p > 0.05) and at six months after treatments (∆E 9.0 ± 1.9 vs. 9.2 ± 2.5, p > 0.05), or between HP35 and HP40 groups immediately after whitening (∆E 5.9 ± 1.2 vs. 5.3 ± 1.7, p > 0.05) and at six months after treatments (∆E 7.2 ± 1.6 vs. 7.7 ± 1.3, p > 0.05). The two at-home whitening systems achieved significantly better whitening outcomes than the two in-office products immediately after whitening (p < 0.05). However, at six months after treatments, the differences between at-home and in-office treatments had narrowed significantly (p > 0.05). There were no statistically significant differences with respect to the Sa values between the treated and untreated surfaces (p > 0.05). Conclusions: Tooth whitening products in the same product category have similar whitening efficacies, despite significant differences in treatment durations (7 vs. 140 h, and 30 min vs. 60 min, respectively). Take-home products achieved better whitening outcomes than in-office products, but they needed 14 to 280 times longer treatment durations. Full article
(This article belongs to the Section Dentistry and Oral Health)
Show Figures

Figure 1

14 pages, 1341 KB  
Article
Events Detection of Anticipatory Postural Adjustments through a Wearable Accelerometer Sensor Is Comparable to That Measured by the Force Platform in Subjects with Parkinson’s Disease
by Tiziana Lencioni, Mario Meloni, Thomas Bowman, Alberto Marzegan, Antonio Caronni, Ilaria Carpinella, Anna Castagna, Valerio Gower, Maurizio Ferrarin and Elisa Pelosin
Sensors 2022, 22(7), 2668; https://doi.org/10.3390/s22072668 - 30 Mar 2022
Cited by 14 | Viewed by 5214
Abstract
Out-of-the-lab instrumented gait testing focuses on steady-state gait and usually does not include gait initiation (GI) measures. GI involves Anticipatory Postural Adjustments (APAs), which propel the center of mass (COM) forward and laterally before the first step. These movements are impaired in persons [...] Read more.
Out-of-the-lab instrumented gait testing focuses on steady-state gait and usually does not include gait initiation (GI) measures. GI involves Anticipatory Postural Adjustments (APAs), which propel the center of mass (COM) forward and laterally before the first step. These movements are impaired in persons with Parkinson’s disease (PD), contributing to their pathological gait. The use of a simple GI testing system, outside the lab, would allow improving gait rehabilitation of PD patients. Here, we evaluated the metrological quality of using a single inertial measurement unit for APA detection as compared with the use of a gold-standard system, i.e., the force platforms. Twenty-five PD and eight elderly subjects (ELD) were asked to initiate gait in response to auditory stimuli while wearing an IMU on the trunk. Temporal parameters (APA-Onset, Time-to-Toe-Off, Time-to-Heel-Strike, APA-Duration, Swing-Duration) extracted from the accelerometric data and force platforms were significantly correlated (mean(SD), r: 0.99(0.01), slope: 0.97(0.02)) showing a good level of agreement (LOA [s]: 0.04(0.01), CV [%]: 2.9(1.7)). PD showed longer APA-Duration compared to ELD ([s] 0.81(0.17) vs. 0.59(0.09) p < 0.01). APA parameters showed moderate correlation with the MDS-UPDRS Rigidity, Characterizing-FOG questionnaire and FAB-2 planning. The single IMU-based reconstruction algorithm was effective in measuring APAs timings in PD. The current work sets the stage for future developments of tele-rehabilitation and home-based exercises. Full article
(This article belongs to the Special Issue Wearable Sensors for Biomechanics Applications)
Show Figures

Figure 1

14 pages, 2090 KB  
Article
Comparison of Laboratory and Daily-Life Gait Speed Assessment during ON and OFF States in Parkinson’s Disease
by Marta Francisca Corrà, Arash Atrsaei, Ana Sardoreira, Clint Hansen, Kamiar Aminian, Manuel Correia, Nuno Vila-Chã, Walter Maetzler and Luís Maia
Sensors 2021, 21(12), 3974; https://doi.org/10.3390/s21123974 - 9 Jun 2021
Cited by 25 | Viewed by 5049
Abstract
Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We [...] Read more.
Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home performance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD. Full article
(This article belongs to the Special Issue Novel Approaches for Advancing Wearable Sensing Technologies)
Show Figures

Figure 1

19 pages, 360 KB  
Article
Assessment of Sit-to-Stand Transfers during Daily Life Using an Accelerometer on the Lower Back
by Lukas Adamowicz, F. Isik Karahanoglu, Christopher Cicalo, Hao Zhang, Charmaine Demanuele, Mar Santamaria, Xuemei Cai and Shyamal Patel
Sensors 2020, 20(22), 6618; https://doi.org/10.3390/s20226618 - 19 Nov 2020
Cited by 20 | Viewed by 7990
Abstract
The ability to perform sit-to-stand (STS) transfers has a significant impact on the functional mobility of an individual. Wearable technology has the potential to enable the objective, long-term monitoring of STS transfers during daily life. However, despite several recent efforts, most algorithms for [...] Read more.
The ability to perform sit-to-stand (STS) transfers has a significant impact on the functional mobility of an individual. Wearable technology has the potential to enable the objective, long-term monitoring of STS transfers during daily life. However, despite several recent efforts, most algorithms for detecting STS transfers rely on multiple sensing modalities or device locations and have predominantly been used for assessment during the performance of prescribed tasks in a lab setting. A novel wavelet-based algorithm for detecting STS transfers from data recorded using an accelerometer on the lower back is presented herein. The proposed algorithm is independent of device orientation and was validated on data captured in the lab from younger and older healthy adults as well as in people with Parkinson’s disease (PwPD). The algorithm was then used for processing data captured in free-living conditions to assess the ability of multiple features extracted from STS transfers to detect age-related group differences and assess the impact of monitoring duration on the reliability of measurements. The results show that performance of the proposed algorithm was comparable or significantly better than that of a commercially available system (precision: 0.990 vs. 0.868 in healthy adults) and a previously published algorithm (precision: 0.988 vs. 0.643 in persons with Parkinson’s disease). Moreover, features extracted from STS transfers at home were able to detect age-related group differences at a higher level of significance compared to data captured in the lab during the performance of prescribed tasks. Finally, simulation results showed that a monitoring duration of 3 days was sufficient to achieve good reliability for measurement of STS features. These results point towards the feasibility of using a single accelerometer on the lower back for detection and assessment of STS transfers during daily life. Future work in different patient populations is needed to evaluate the performance of the proposed algorithm, as well as assess the sensitivity and reliability of the STS features. Full article
(This article belongs to the Special Issue Application of Wearables in Digital Medicine)
Show Figures

Figure 1

19 pages, 2146 KB  
Communication
Effect of Morning vs. Evening Turmeric Consumption on Urine Oxidative Stress Biomarkers in Obese, Middle-Aged Adults: A Feasibility Study
by Cynthia Blanton and Barbara Gordon
Int. J. Environ. Res. Public Health 2020, 17(11), 4088; https://doi.org/10.3390/ijerph17114088 - 8 Jun 2020
Cited by 12 | Viewed by 5605
Abstract
The circadian rhythm of biological systems is an important consideration in developing health interventions. The immune and oxidative defense systems exhibit circadian periodicity, with an anticipatory increase in activity coincident with the onset of the active period. Spice consumption is associated with enhanced [...] Read more.
The circadian rhythm of biological systems is an important consideration in developing health interventions. The immune and oxidative defense systems exhibit circadian periodicity, with an anticipatory increase in activity coincident with the onset of the active period. Spice consumption is associated with enhanced oxidative defense. The objective of this study was to test the feasibility of a protocol comparing the effects of morning vs. evening consumption of turmeric on urine markers of oxidative stress in obese, middle-aged adults. Using a within-sample design, participants received each of four clock time x treatment administrations, each separated by one week: morning turmeric; evening turmeric; morning control; evening control. Participants prepared for each lab visit by consuming a low-antioxidant diet for two days and fasting for 12 h. Urine was collected in the lab at baseline and one-hour post-meal and at home for the following five hours. The results showed that the processes were successful in executing the protocol and collecting the measurements and that participants understood and adhered to the instructions. The findings also revealed that the spice treatment did not elicit the expected antioxidant effect and that the six-hour post-treatment urine collection period did not detect differences in urine endpoints across treatments. This feasibility study revealed that modifications to the spice treatment and urine sampling timeline are needed before implementing a larger study. Full article
(This article belongs to the Special Issue Dietary Polyphenols and Health)
Show Figures

Figure 1

Back to TopTop